Other General Analysis Instruments
Filter
Showing 91–120 of 279 results
| Brand | CNI (Zhongjiao Jinyuan) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | FB-25 / FB-50 (Customizable) |
| Price | USD 285 (approx. ¥2016) |
| Compatibility | Standardized optical filter mounts for UV-Vis-NIR spectroscopy and photochemical applications |
| Brand | AWT |
|---|---|
| Origin | United Kingdom |
| Model | 1000 Series Fire Detector Test Chamber |
| Compliance | EN 54-7, EN 54-5, EN 14604, BS 5446-2, GB 4715-2024, GB 4716-2024 |
| Configuration Options | 1100 (smoke-only), 1300 (heat-only), 1400 (combined smoke/heat), 1700 (heat-only with active cooling), 1800 (combined smoke/heat with active cooling) |
| Form Factor | Benchtop |
| Application Domain | Factory QC, R&D Lab, Certification Testing |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AccuSeries |
| Price | Upon Request |
| Measurement Principle | Redox Colorimetric Titration |
| Wavelengths | 650 nm (test), 810 nm (reference) |
| Range | 0–1,000 ppm (customizable) |
| Accuracy | ±1% of full scale |
| Linearity | ±1% FS |
| Repeatability | ±1% FS |
| Analysis Cycle Time | 10 min |
| Sensitivity | 1% FS |
| Ambient Temperature | 20–60 °C (−4–140 °F) |
| Dimensions | 1016 mm H × 406 mm W × 241 mm D |
| Weight | 45.3 kg |
| Sample Interface | 1/4″ compression fitting |
| Sample Flow Rate | 200 mL/min |
| Max Sample Pressure | <5 psi |
| Max Suspended Solids | <1,000 µm |
| Power Supply | 24 VDC or 90–240 VAC |
| Analog Outputs | up to eight isolated 4–20 mA (self-powered) |
| Digital Inputs | 8 dry/wet contacts (24 VDC) |
| Ethernet | Embedded GUI via Modbus TCP/IP |
| Serial Protocols | Modbus RTU over RS-232/RS-485 |
| Alarm Outputs | User-configurable relay outputs |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted with included hardware |
| Corrosion Resistance | H₂S- and Cl₂-resistant housing |
| Flow Path Architecture | Modular, scalable to 6 independent sample streams |
| Control Architecture | Physically segregated electronics and wet chemistry modules |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GASERA-F10 |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GF-1800 |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Model | ZF-1800A |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Application Domain | Food Contact Material (FCM) Compliance Testing |
| Standards Compliance | GB 31604.8–2016, GB 31604.1–2015, GB/T 5009.156–2016, GB/T 9740–2008, GB/T 23949–2009, YBB00342002–2015, YBB00102005–2015, YBB00082002–2015 |
| Measurement Range | 0.167–167,000 mg/dm² |
| Resolution | 0.0001 mg/dm² |
| Balance Capacity | 0–200 g |
| Balance Readability | 0.1 mg |
| Water Bath Temp Control | 68.3–100 °C |
| Heating Chamber Temp Control | 68.3–117.9 °C |
| Cooling Chamber Temp Control | <27.5 °C |
| Temperature Accuracy | ±3 °C |
| Sample Throughput | 1–18 independent test positions |
| Gravimetric恒重 Cycle Time | 2.5 h (typical) |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (L×W×H) | 180 × 90 × 120 cm |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 1500 W |
| Brand | GBPI |
|---|---|
| Model | ZF1800-2A |
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Category | Other General Analytical Instruments |
| Measuring Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | RT–100 °C |
| Heating Chamber Temp Control | RT–117.9 °C |
| Cooling Chamber Temp Control | 10–35 °C |
| Temperature Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent stations |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Main Unit) | 178 × 93 × 145 cm (L×W×H) |
| Solvent Recovery System Dimensions | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Model | ZF1800-A1 |
| Measuring Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | RT–100 °C |
| Heating Chamber Temp Control | RT–117.9 °C |
| Cooling Chamber Temp Control | 10–35 °C |
| Temperature Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent stations |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Main Unit) | 178 × 93 × 145 cm (L×W×H) |
| Dimensions (Solvent Recovery Unit) | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | ZF1800-D |
| Price | Upon Request |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp. Control | RT–100 °C |
| Heating Chamber Temp. Control | RT–117.9 °C |
| Cooling Chamber Temp. Control | 10–35 °C |
| Temperature Accuracy | ±5 °C |
| Sample Capacity | 1–18 independent test positions |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Main Unit) | 178 × 93 × 145 cm (L×W×H) |
| Solvent Recovery System Dimensions | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Model | ZF1800-F |
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Category | Other General Analytical Instruments |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | RT–100 °C |
| Heating Chamber Temp Control | RT–117.9 °C |
| Cooling Chamber Temp Control | 10–35 °C |
| Temperature Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent test positions |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Tester) | 178 × 93 × 145 cm (L×W×H) |
| Dimensions (Solvent Recovery Unit) | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Model | ZF1800-S |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Other General Analytical Instruments |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | RT–100 °C |
| Heating Chamber Temp Control | RT–117.9 °C |
| Cooling Chamber Temp Control | 10–35 °C |
| Temperature Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent test positions |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Main Unit) | 178 × 93 × 145 cm (L×W×H) |
| Solvent Recovery System Dimensions | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | ZF1800-T |
| Quotation | Upon Request |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | Ambient to 100 °C |
| Heating Chamber Temp Control | Ambient to 117.9 °C |
| Cooling Chamber Temp Control | 10–35 °C |
| Temperature Accuracy | ±5 °C |
| Sample Positions | 1–18 (independent) |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Main Unit) | 178 × 93 × 145 cm (L×W×H) |
| Solvent Recovery System Dimensions | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Model | ZF1800A |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Category | General Analytical Instrument for Food Contact Materials Testing |
| Measurement Range | 0.167–167,000 mg/dm² |
| Resolution | 0.0001 mg/dm² |
| Balance Capacity | 0–200 g / Readability: 0.1 mg |
| Water Bath Temp Control | 68.3–100 °C |
| Heating Chamber Temp Control | 68.3–117.9 °C |
| Cooling Chamber Temp Control | <27.5 °C |
| Temp Accuracy | ±3 °C |
| Sample Capacity | 1–18 independent test positions |
| Evaporation Dish Volume | 0–200 mL |
| Dimensions (L×W×H) | 180 × 90 × 120 cm |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 1500 W |
| Brand | GBPI |
|---|---|
| Model | ZF1800B |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Domestic Instrument |
| Price | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZF1800B1 |
| Price | Upon Request |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | RT–100 °C |
| Heating Chamber Temp Control | RT–117.9 °C |
| Cooling Chamber Temp Control | 10–35 °C |
| Temperature Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent stations |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (Main Unit) | 178 × 93 × 145 cm (L×W×H) |
| Solvent Recovery System Dimensions | 120 × 88 × 170 cm (L×W×H) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Model | ZF1800C |
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Category | Other General Analytical Instruments |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | Ambient to 100 °C |
| Heating Chamber Temp Control | Ambient to 120 °C |
| Cooling Chamber Temp Control | Ambient |
| Temp Accuracy | ±0.5 °C |
| Chamber Temp Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent test positions |
| Gravimetric Constant-Weight Duration | 2.5 h (standard) |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (L×W×H) | 180 cm × 90 cm × 120 cm |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | ZF1800D |
| Pricing | Upon Request |
| Measurement Range | 0.2–167,000 mg/dm² |
| Resolution | 0.0001 g/dm² |
| Balance Capacity | 0–200 g |
| Balance Resolution | 0.1 mg |
| Water Bath Temp Control | Ambient to 100 °C |
| Heating Chamber Temp Control | Ambient to 120 °C |
| Cooling Chamber Temp Control | Ambient |
| Temp Accuracy | ±0.5 °C |
| Chamber Temp Uniformity | ±5 °C |
| Sample Capacity | 1–18 independent test positions |
| Gravimetric Stabilization Time | 2.5 h (standard) |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (L×W×H) | 180 × 90 × 120 cm |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 5000 W |
| Brand | GBPI |
|---|---|
| Model | ZF3800A |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Measuring Range | 0.167–167,000 mg/dm² |
| Resolution | 0.0001 mg/dm² |
| Balance Capacity | 0–200 g |
| Balance Readability | 0.1 mg |
| Water Bath Temp. Control | 68.3–100 °C |
| Heating Chamber Temp. Control | 68.3–117.9 °C |
| Cooling Chamber Temp. Control | <27.5 °C |
| Temperature Accuracy | ±3 °C |
| Sample Capacity | 1–18 independent test positions |
| Gravimetric Constant-Weight Duration | 2.5 h (standard) |
| Evaporating Dish Volume | 0–200 mL |
| Dimensions (L×W×H) | 180 × 90 × 120 cm |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 1500 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Model | ZF800A |
| Testing Capacity | 8 independent stations (expandable to 36) |
| Residue Mass Range | 0–80 g |
| Weighing Accuracy | 0.2 mg |
| System Resolution | 0.1 mg |
| Temperature Control Range | 80–130 °C |
| Temperature Stability | ±0.2 °C |
| Hot Air Circulation Velocity | 0.2 m/s |
| Sample Volume per Vessel | 0–200 mL |
| Evaporation Vessel Capacity | 230 mL (included ×8) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 4000 W |
| Dimensions (W×D×H) | 937 × 660 × 830 mm |
| Interface Fittings | 1/8″ stainless steel tubing & Φ6 mm polyurethane tubing |
| Standard Accessories | Dedicated software, communication cable, 200 g calibration weight, Φ8 mm PU air tube |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Model | ZF800A |
| Measurement Range | 0–80 g (residue mass) |
| Accuracy | 0.1 mg |
| Resolution | 0.01 mg |
| Temperature Control Range | 80–150 °C (typical operating range: 100–130 °C) |
| Temperature Stability | ±0.1 °C (typical: ±0.2 °C) |
| Hot Air Circulation Velocity | 0.2 m/s |
| Sample Volume Capacity | 0–500 mL |
| Chamber Volume | 86 L |
| Independent Test Stations | 1–8 (expandable to 36) |
| Gas Supply | Compressed air |
| Pressure Requirement | 0.6 MPa |
| Tubing Interface | Φ6 mm polyurethane |
| Power Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Model | ZF900B |
| Origin | Guangdong, China |
| Manufacturer | GBPI Packaging Instruments Co., Ltd. |
| Measurement Range | 0–80 g (residue mass) |
| Weighing Accuracy | ±0.2 mg |
| System Resolution | 0.1 mg |
| Temperature Control Range | Ambient to 130 °C |
| Temperature Stability | ±0.2 °C |
| Air Circulation Velocity | 0.2 m/s |
| Sample Volume Capacity | 0–200 mL per vessel |
| Independent Test Positions | 8 |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 1000 W |
| Dimensions (W×D×H) | 937 × 660 × 830 mm |
| Brand | GBPI |
|---|---|
| Model | ZF900C |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance Standards | GB/T 5009.60–2003, GB/T 5009.64–2003, GB/T 5009.68–2003, GB/T 5009.69–2008, GB/T 5009.203–2003, GB/T 9740–2008 |
| Residue Mass Range | 0–80 g |
| Weighing Accuracy | ±0.2 mg |
| Resolution | 0.1 mg |
| Temperature Control Range | Ambient to 130 °C |
| Temperature Stability | ±0.2 °C |
| Air Circulation Velocity | 0.2 m/s |
| Sample Volume Capacity | 0–200 mL per vessel |
| Independent Test Stations | 8 |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 1000 W |
| Dimensions (W×D×H) | 937 × 660 × 830 mm |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | SoluStar 7640 |
| Standard Compliance | IDF 129, ISO 8156 |
| Rotational Speed Range | 1,000–4,000 rpm (adjustable in 10 rpm increments) |
| Fixed setting | 3,600 rpm |
| Stirring Duration | 1–599 s (adjustable) |
| Default setting | 90 s |
| Safety Interlock | Magnetic door switch with transparent safety cover |
| Vessel Handling | Motorized vertical lift and height adjustment for 500 mL borosilicate glass stirring cup |
| Impeller | 16-blade stainless steel, clockwise rotation, blades oriented with flat side downward and upward tilt from right to left |
| Dimensions (W × D × H) | 16.5 × 20.5 × 44.5 cm |
| Weight | 5 kg |
| Power Supply | 220 V, 50 Hz |
| Max. Power Consumption | 43 W |
| Brand | GUOCHUANG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BR-3000A |
| Measurement Principle | Microcoulometric Titration (Electrogenerated Bromine) |
| Standards Compliance | GB/T 1815–1997, SH/T 1551–2018, ASTM D1492, SH/T 0630–1996 |
| Bromine Number Range | 0–300 g Br/100 g sample |
| Bromine Index Range | 0–1000 mg Br/100 g sample |
| Resolution | 0.001 mg Br |
| Accuracy | ±3% ±0.2 g Br (bromine number) |
| Detection Limit | 0.01 mg Br |
| Cell Volume | 150 mL |
| Power Consumption | 30 W |
| Weight | 4 kg |
| Dimensions (L×W×H) | 350 × 280 × 160 mm |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | H-7B |
| Pricing | Available Upon Request |
| Brand | JHX |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HandSPEC |
| Pricing | Available Upon Request |
| Brand | HARKE |
|---|---|
| Model | HK-Q3 |
| Measurement Principle | Vacuum Method (ASTM D1434, ISO 2556, ISO 15105-1) |
| Test Gases | O₂, N₂, CO₂, Air, He, H₂, CH₄, C₃H₈, C₄H₁₀, NH₃ |
| Permeation Range | 0.05–160,000 cm³/(m²·24h·0.1 MPa) |
| Resolution | 0.001 cm³/(m²·24h·0.1 MPa) |
| Vacuum Resolution | 0.1 Pa |
| Temperature Control Range | 5–95 °C (external chiller/heater required) |
| Temp. Stability | ±0.1 °C |
| Sample Thickness | ≤5 mm (customizable) |
| Sample Area | 48 cm² |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Supply Gas Pressure | 0.3–1.0 MPa |
| Gas Inlet Port | Ø8 mm |
| Dimensions (L×D×H) | 330 × 600 × 330 mm |
| Weight | 28 kg |
| Power | AC 220 V, 50 Hz |
| Compliance | ASTM D1434, ISO 2556, ISO 15105-1, GB/T 1038, YY/T 0698.5 |
| Brand | Harrick |
|---|---|
| Origin | USA |
| Model | HPL-C-13 |
| Construction Material | 316 Stainless Steel |
| Maximum Operating Pressure | 34.5 MPa (5000 psi) |
| Temperature Range | Up to 240 °C (with Kalrez O-rings) or 200 °C (with Viton O-rings) |
| Optical Path Length Range | 6 µm – 5 mm (via interchangeable PTFE spacers) |
| Window Aperture | 8 mm clear diameter |
| Port Configuration | Two 1/16″ Swagelok™ fittings |
| Thermal Management | Integrated cartridge heater, K-type thermocouple, and coolant channels |
| Mounting | FTIR-compatible slide-in sample stage |
| Compliance | Designed for ASTM E1421-compliant IR transmission measurements under process-relevant conditions |