Other General Analysis Instruments
Filter
Showing 151–180 of 279 results
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | 3Flex |
| Gas Adsorption Capability | Physisorption & Chemisorption (optional) |
| Tri-Station Operation | Independent simultaneous analysis |
| Pressure Range | Down to 1×10⁻⁹ P/P₀ |
| Detection Limit | Ultra-micropore resolution (≤ 0.7 nm) |
| Vapor Compatibility | Integrated thermostatted manifold (45 °C ±0.05 °C), optional heated vapor dosing |
| Software | MicroActive™ with customizable reporting, ASTM/ISO-compliant data processing |
| Sample Preparation | In-situ tube heater for degassing under vacuum or inert gas |
| Sealing System | Metal-sealed, hard-stop valves with corrosion-resistant manifold |
| P₀ Measurement | Dedicated P₀ sensor with continuous saturation pressure monitoring |
| Fluid Library | >80 pre-loaded adsorbates (N₂, Ar, CO₂, H₂, Kr, H₂O, alcohols, hydrocarbons, etc.) |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | AutoChem II 2920 |
| Temperature Range | –110 °C to 1100 °C |
| Detection Method | High-Stability TCD (Thermal Conductivity Detector) |
| Gas Inlets | 12 |
| Automated Valves | 4 × 6-port valves |
| Mass Flow Controllers | 4 (sample prep, dual carrier/reference, analysis) |
| Sample Tube | FlowThru™ quartz, rated to 1100 °C |
| TCD Zone Temperature | 150–250 °C |
| Optional Accessories | Online MS/FTIR/GC interface, vapor generator, cryogenic bath (–110 °C) |
| Software | Windows-based AutoChem software with GRAMS/32 peak processing module |
| Analytical Modes | TPD, TPR, TPO, TPRx, pulse chemisorption, isothermal reaction, BET surface area |
| Brand | Microphotons |
|---|---|
| Origin | Imported |
| Manufacturer Type | OEM Manufacturer |
| Model | C3A-2700LAE |
| Pricing | Upon Request |
| Model | 318C+ |
|---|---|
| Price | Upon Request) |
| [Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | 318C+ |
| Wavelength Range | 350–800 nm |
| Filter Positions | 10 (standard: 405, 450, 492, 630 nm |
| Absorbance Range | 0.000–4.000 A |
| Optical Channels | 8-sample + 1 optional reference channel |
| Absorbance Stability | ≤ ±0.002 A or ≤ 0.5% T / 10 min |
| Accuracy | ≤ ±0.005 A or ±0.2% T |
| CV (Repeatability) | ≤ 0.2% |
| Sensitivity | ≥ 0.01 L/mg |
| Channel Uniformity | ≤ 0.01 A |
| Wavelength Accuracy | ±1 nm |
| Bandwidth (FWHM) | ≤ 8 nm |
| Display Resolution | 0.001 A (display), 0.0001 A (internal calculation) |
| Read Time | ≤3 sec/96-well (single wavelength), ≤6 sec/96-well (dual wavelength) |
| Plate Types | Standard 96-well microplates, strips, flat/U/V-bottom wells |
| Display | 7-inch color TFT-LCD touchscreen |
| Input | Touchscreen + optional USB mouse/keyboard |
| Built-in Thermal Printer | Yes |
| Data Storage | ≥200,000 assay results, ≥500 test protocols (expandable) |
| Interfaces | USB-A, USB-B, RS-232, parallel port |
| Operating Environment | 5–40 °C, 15–80% RH |
| Power Supply | 220 V ±10%, 50/60 Hz |
| Dimensions (L×W×H) | 475 × 350 × 210 mm |
| Weight | 11.5 kg] |
| Brand | Chengmeng Technology |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Millicell® ERS 3.0 |
| Price | Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ORION CH4 |
| Pricing | Available Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ORION NH3 |
| Pricing | Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ORION CO₂ CH₄ |
| Pricing | Available Upon Request |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MS200S-II |
| Dimensions | 460 × 270 × 300 mm |
| Operating Liquid Inlet Pressure | 100–400 psi |
| Maximum Flash & Jacket Temperature | 230 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Brand | NC Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EA-IRMS-iRIS |
| Pricing | Upon Request |
| Brand | NCS (China Iron and Steel Research Institute Group) |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | Pure Iron Flux |
| Pricing | Available Upon Request |
| Brand | NewOpto |
|---|---|
| Origin | Zhejiang, China |
| Model | NR-Series Reflectance Probe |
| Wavelength Ranges | 190–2200 nm (model-dependent) |
| Core Diameters | 200 µm, 400 µm, or 600 µm |
| Fiber Configuration | 6 illumination fibers + 1 collection fiber |
| Connector Types | SMA 905 (standard), customizable |
| Housing Material | Stainless steel or anodized aluminum |
| Operating Temperature | −10 °C to +60 °C |
| IP Rating | IP54 (standard), optional IP67 |
| Brand | NewOpto |
|---|---|
| Model | NY-Series Y-Branch Fiber |
| Core Diameter | 200/400/600 µm |
| Wavelength Range | 190–2200 nm (UV-VIS-NIR-BW variants) |
| Length | 2 m (standard), customizable (0.5/1/2 m) |
| Jacket Material | Plastic or Metal |
| Connector | SMA905 (standard), optional FC/ST |
| Spectral Transmission | Optimized per grade (UV, VIS, NIR, Broadband) |
| Numerical Aperture | 0.22 (typical, silica-based step-index) |
| Operating Temperature | −40 °C to +85 °C |
| Compliance | RoHS-compliant construction, ISO 9001-manufactured components |
| Brand | North Guang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | BQS-19 |
| Price | USD 495 (approx. based on ¥3500) |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Dimensions (W×D×H) | 240 × 320 × 260 mm |
| Test Pressure Range | 500–6900 mbar (customizable sensor available) |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Ambient Temperature | 0–50 °C |
| Relative Humidity | 10–80% RH |
| Bubble Point Test Time | 2 ± 2 min |
| Diffusion Flow Test Time | 7 ± 2 min |
| Water Intrusion Flow Test Time | 7 ± 2 min |
| System Leak Check Time | 3 ± 1 min |
| Display | 5.7–7-inch color TFT touchscreen (256-color), Chinese/English UI |
| Data Storage | 32 GB internal flash memory (≥1 million test records) |
| Print Output | Thermal printer supporting bilingual (CN/EN) reports including test parameters, results, and real-time pressure/flow curves |
| OS | Windows CE 6.0 |
| Controller | ARM9-based embedded system |
| Brand | North Guangjingyi / All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | EST-121 |
| Resistance Measurement Range | 1×10⁴ Ω to 1×10¹⁸ Ω (10 decades) |
| Current Measurement Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Test Voltages | DC 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V (±10%) |
| Accuracy | ±1% to ±15% depending on range (see full spec table per decade) |
| Display | Full-digit LCD |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | <90% RH |
| Power Supply | AC 220 V, 50 Hz, ~10 W |
| Dimensions | 300 mm × 280 mm × 150 mm |
| Weight | ~3.0 kg |
| Compliance | Designed for ASTM D257, IEC 60093, GB/T 1410, ISO 3915 |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | AC1384 |
| Temperature Range | 10–100°C (4°C hold) |
| Max Ramp Rate | 3.4°C/s |
| Temperature Uniformity at 55°C | ±0.3°C |
| Temperature Accuracy at 55°C | ±0.25°C |
| Gradient Range | 1–29°C |
| Block Configuration | Single 384-well module |
| Display | 7-inch 1080p HD touchscreen |
| Operating System | Android |
| Max Program Storage | 1,000 protocols |
| Heat Lid Temp Range | 35–115°C (adjustable pressure) |
| Dimensions (W×D×H) | 430 × 260 × 200 mm |
| Weight | 11.8 kg |
| Power Input | 100–230 V, 50–60 Hz |
| Max Power Consumption | 450 W |
| Noise Level | ≤50 dB(A) |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PQZF-1000 |
| Pricing | Available Upon Request |
| Extraction Principle | Soxhlet Extraction (Gravimetric) |
| Compliance | GB 5009.6–2016, GB/T 6433–2006, SN/T 0800.2–1999 |
| Display | 4.7-inch Full-Color TFT Touchscreen |
| Extraction Modes | Soxhlet, Hot Extraction, Soxhlet-Hot Hybrid, Continuous Flow, Spot Flow, Standard Hot Extraction |
| Sample Capacity | 6 samples per run |
| Sample Mass Range | 0.5–15 g |
| Solvent Cup Volume | 150 mL |
| Temperature Control Range | RT+5 °C to 300 °C |
| Temperature Accuracy | ±1 °C |
| Solvent Recovery Rate | ≥85% |
| Heating Power | 2000 W |
| Power Supply | 220 V ±10%, 50 Hz |
| Safety Features | Petroleum Ether Leak Detection & Auto-Shutdown |
| Cooling System | Smart Temperature-Controlled Inlet/Outlet Water Flow |
| Heating Method | Integrated Metal Bath with Programmable Ramp Heating |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SDC-1000 |
| Sample Capacity | 1–12 positions |
| Concentration Vessels | 50 mL, 150 mL, and 200 mL |
| Endpoint Detection | Optical dryness sensor per channel |
| Endpoint Volume Options | 1.0 mL, 0.5 mL, or near-dry (~0.1 mL) |
| Water Bath Temperature Range | Room temperature +5 °C to 100 °C (±0.3 °C) |
| Nitrogen Blow Time | 0–9999 min |
| Nitrogen Pressure Control | 0–0.10 MPa (10-step adjustable, 0.01 MPa increments) with auto-regulation |
| Inlet Nitrogen Supply Pressure | 0.20–0.80 MPa |
| Max Allowable Inlet Pressure | 1.00 MPa |
| Gas Consumption | ~500 mL/min per channel at 0.10 MPa |
| Sensitivity Adjustment | Continuously variable optical endpoint detection |
| Control Interface | Color LCD touchscreen |
| Operating Modes | Manual / Timed / Volume-based endpoint |
| Safety Features | Lid-open detection, low-water alarm & auto-refill, low-pressure alarm, 60-sec pause/resume memory |
| Materials | Plasticizer-free silicone seals, food-grade PTFE gas tubing |
| Exhaust System | Integrated high-efficiency fume extraction |
| Drain Valve | Integrated for bath water replacement |
| Heating Power | 2000 W |
| Power Supply | 220 V / 60 Hz |
| Dimensions (W×D×H) | 600 × 540 × 400 mm |
| Weight | 28 kg |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | PerkinElmer DSC 8500 coupled with EXFO® UV Curing System |
| Pricing | Available upon request |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Producer |
| Model | Acid-Base 50 mL |
| Graduation Interval | 0.1 mL |
| Material | Perfluoroalkoxy (PFA) |
| Capacity | 50 mL |
| Configuration | Dual-Function (Acid & Base) |
| Compliance | Suitable for ISO/IEC 17025-compliant laboratories requiring inert fluid handling |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | NJ-HF HF Separation Apparatus |
| Price Range | USD 140–2,800 |
| Brand | Binzhenghong |
|---|---|
| Model | GL32 Series |
| Material | Perfluoroalkoxy (PFA) |
| Transparency | Semi-Transparent |
| Operating Temperature Range | −200 °C to +260 °C |
| Electrical Insulation | Frequency- and Temperature-Independent Dielectric Properties |
| Metallic Impurity Levels | Sub-ppt (parts-per-trillion) |
| Extractables/Leachables | Ultra-Low |
| Compliance | Suitable for ISO/IEC 17025-accredited laboratories, compatible with ICP-MS, ICP-OES, and GF-AAS workflows |
| Regulatory Alignment | Meets requirements for trace-metal-free storage per ASTM D5127 and USP <661.2> for fluoropolymer containers |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | NJ-PFA-SG-015 |
| Price | USD 37 (FOB Jiangsu) |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Producer |
| Country of Origin | China |
| Model | NJ-PFA-LD |
| Diameter Options | φ40 mm (top inlet), 160 mm (overall height) |
| Material | Perfluoroalkoxy alkane (PFA), ASTM D3295-compliant |
| Construction | Seamless, one-piece molded |
| Surface Finish | <0.4 µm Ra, electropolished equivalent |
| Temperature Range | –200 °C to +260 °C |
| Chemical Resistance | Resistant to HF, aqua regia, fuming HNO₃, molten alkali, and all organic solvents per ASTM D543 |
| Brand | Binzhenghong |
|---|---|
| Capacity | 50 mL (also available in 10–1000 mL range) |
| Material | Perfluoroalkoxy alkane (PFA) |
| Temperature Range | −200 °C to +260 °C |
| Calibration Type | Class A, TC (To Contain) |
| Seal Design | Threaded cap with PFA-faced septum |
| Surface Finish | Optically clear, ultra-smooth interior |
| Chemical Resistance | Resistant to HF, aqua regia, concentrated acids/bases, and organic solvents |
| Extractables/Leachables | Ultra-low leachable profile per USP <661.1> and ASTM D4975 |
| Cleaning Recommendation | ≤60 °C aqueous or mild solvent rinse |
| Traceability | Optional NIST-traceable calibration certificate (customer-specified, fee borne by buyer) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | A0214 |
| Pricing | Available Upon Request |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PLD-GRS6 |
| Price | USD 680 (FOB) |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Detection Electrode | Dual Platinum Electrodes |
| Control System | PULL T 8.0 Embedded Microcontroller Platform |
| Measurement Range | 1 µg – 30 mg H₂O (standard mode) |
| Sensitivity | 0.1 µg H₂O |
| Accuracy | ±5% relative or ±1 µg absolute, whichever is greater |
| Sample Types | Liquids, Gases, Solids (with optional oven adapter) |
| Titration Cell Volume | 150 mL |
| Stirring Mechanism | Integrated Magnetic Stirrer |
| Display | 20×2 Character LCD with real-time clock, electrolysis rate (µg/s), and endpoint status |
| Endpoint Detection | Dual-platinum amperometric detection |
| Output | Built-in thermal printer (16-character line, auto-print of parameters and results) |
| Power Supply | 220 V ±10%, 50 Hz ±0.5 Hz |
| Power Consumption | 40 W |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤70% RH |
| Compliance Standards | GB/T 7600, GB/T 11133, GB/T 6283, SH/T 0207, SH/T 0246, SH/T 0255 |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | IVA Versa |
| Compliance | ASTM D5225, ISO 1628-1 |
| Operating Temperature Range | 20–45 °C |
| Solvent Compatibility | Decalin, Chloroform, THF, Trichlorobenzene, and other common organic solvents |
| Sample Preparation Options | Single-sample dissolution station, High-throughput autosampler (42 vials), High-speed autosampler (15 vials) |
| Automation Level | Fully automated dissolution, filtration, dilution, and viscometric measurement |
| Cleaning | Self-cleaning dual-capillary relative viscometer design |
| Safety | Solvent-handling automation eliminates manual solvent exposure |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Pri-eco |
| Country of Origin | Domestic (China) |
| Model | PRI-8400 |
| Price | Upon Request |