Other General Analysis Instruments
Filter
Showing 1–30 of 279 results
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Heating Methods | Infrared & High-Frequency Induction |
| Temperature Range | −150 °C to 1350 °C |
| Sample Geometry | Ø3 mm × 10 mm (cylindrical) |
| Max. Heating Rate | 100 °C/s (RT → 1350 °C) |
| Max. Cooling Rate | −80 °C/s (1350 °C → 400 °C, He gas quench) |
| Sub-ambient Capability | Liquid nitrogen cooling to −150 °C |
| System Footprint | ~1300 mm W × 1000 mm D × 1700 mm H |
| Compliance | Designed for ASTM E831, ISO 11357-6, and JIS Z 2247 thermal expansion–based phase transition analysis |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AG1000-F |
| Pricing | Upon Request |
| Brand | Aikonchem |
|---|---|
| Model | CentriVet |
| Type | Handheld Electrochemical Blood β-Hydroxybutyrate (BHB) Analyzer |
| Sample | Fresh Whole Bovine Blood |
| Sample Volume | 1.2 µL |
| Assay Time | 9 s |
| Measurement Range | 0.0–8.0 mmol/L |
| Unit | mmol/L |
| Auto Power-Off | Activated after 2 min of inactivity |
| Operating Temperature | 5–45 °C |
| Operating Relative Humidity | 10–90% RH (non-condensing) |
| Data Storage Capacity | 450 test records with timestamp |
| Power Supply | Two CR2032 3.0 V lithium coin cells |
| Battery Life | ≥3,000 tests (excluding data transmission) |
| Brand | KANTO Chemical |
|---|---|
| Origin | Japan |
| Model | 01118-31 |
| CAS No. | 30586-13-1 |
| pH Transition Range | 9.4 (blue) to 14.0 (red) |
| Purity Grade | Class I (Deer Grade) |
| Loss on Drying (105 °C) | ≤10.0 % |
| Residue on Ignition (as sulfate, after drying) | ≤45.0 % |
| Packaging | 25 g per amber glass bottle |
| Storage | Store sealed in a cool, dry place |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EA-I3211 |
| Pricing | Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | i3121 |
| Pricing | Available Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | i3131 |
| Pricing | Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | I3211E |
| Pricing | Available Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | I3211W |
| Pricing | Upon Request |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Futura |
| Pricing | Upon Request |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Smartchem |
| Pricing | Upon Request |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SUPR-CM |
| Price Range | USD 135,000 – 270,000 |
| Brand | Atik |
|---|---|
| Sensor Resolution | 1620 × 1220 pixels |
| Sensor Type | Monochrome back-illuminated CCD |
| Pixel Size | 9.0 µm × 9.0 µm |
| Full Well Capacity | ~100,000 e⁻ |
| Read Noise | <10 e⁻ (at 0.1 MHz) |
| Dark Current | <0.001 e⁻/pixel/sec @ −20 °C |
| Cooling | Thermoelectric (TE) to −20 °C below ambient |
| Interface | USB 2.0 |
| Shutter | Electronic rolling shutter |
| Compliance | CE, RoHS, FCC Class B |
| Software Support | ASCOM, DirectShow, LabVIEW, MATLAB, Python (via SDK) |
| Brand | Atik Instruments |
|---|---|
| Sensor Resolution | 1460 × 1932 pixels |
| Sensor Type | Monochrome Back-Illuminated CCD |
| Pixel Size | 6.45 µm × 6.45 µm |
| Full Well Capacity | ~100,000 e⁻ |
| Read Noise | < 10 e⁻ (at slow readout) |
| Dark Current | < 0.001 e⁻/pixel/sec @ −20 °C |
| Cooling | Thermoelectric (TEC), regulated to ΔT ≤ −45 °C below ambient |
| Interface | USB 2.0 with proprietary low-noise controller |
| Shutter | Electronic Rolling Shutter (global reset capable) |
| Compliance | CE, RoHS, FCC Class B |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AUT-CI-FCM2 Series |
| Pricing | Available Upon Request |
| Wavelength Range | 200–1700 nm |
| Fiber Interface | FC/APC (interchangeable connector options) |
| Core Function | Automated M², beam waist, divergence angle, Rayleigh length, BPP, and 2D/3D intensity distribution measurement |
| Software Platform | RayCi-Pro v5.x (Cinogy INSIDE certified) |
| Compliance | ISO 11146-1:2021, ISO 11146-2:2021, ANSI Z136.1-2022 |
| Brand | Auniontech |
|---|---|
| Model | AUT-EF Series |
| Origin | Shanghai, China |
| Type | Encircled Flux (EF) Measurement Instrument for Multimode Optical Fibers |
| Compliance | IEC 61280-4-1, TIA-526-14-B, ISO/IEC 11801 |
| Interface | Gigabit Ethernet, USB 3.0 |
| Camera Compatibility | Cinogy-compatible scientific CMOS sensors (e.g., IDS UI-3370CP, Basler acA2000-50gm) |
| Software Platform | Windows 10/11 (64-bit), .NET Framework 4.8, OpenGL 4.3+ |
| Data Export | CSV, XML, HDF5 |
| Audit Trail | GLP-compliant operation logging with timestamped user actions |
| Calibration Support | NIST-traceable EF reference fibers (optional) |
| Brand | Auniontech |
|---|---|
| Model | ISX-3 |
| Manufacturer Type | Authorized Distributor |
| Origin | Imported (Germany-engineered, assembled in EU) |
| Measurement Range | DC to 10 MHz |
| Dynamic Range | 180 dB (0.001 Ω to 1 GΩ) |
| Electrode Configurations | 2-, 3-, and 4-terminal |
| Frequency Resolution | Up to 2048 points per sweep |
| Accuracy | <0.1% ± 8 V DC bias |
| Safety Compliance | DIN EN 60601-1:2013-12 (Medical Electrical Equipment — Part 1: General Requirements for Basic Safety and Essential Performance) |
| Interface Options | High-speed USB 2.0, 10/100 Mbps Ethernet (RJ45), optional WLAN |
| Synchronization | Isolated digital Sync-In/Sync-Out port |
| IO Expansion | IsoIO module with programmable digital I/O (8 channels), UART/SPI/I²C support, dual temperature sensor inputs |
| Front-End Architecture | AC-coupled, galvanically isolated IF frontend (Sciospec IF-4BNC) |
| Software Support | Sciospec PC Suite (GUI), COM API for Java/C/LabVIEW/MATLAB integration |
| Origin | Norway |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | APPS |
| Pricing | Available Upon Request |
| Brand | SUSS |
|---|---|
| Origin | Germany |
| Model | BAM-E001 |
| Dimensions | 8 mm × 181 mm × 181 mm |
| Density | 1.35 ± 0.02 g/cm³ (ISO 1183-1) |
| Hardness | 60 ± 3 Shore A (ISO 7619) |
| Mass Loss | 210 ± 10 mg per test piece (DIN ISO 4649, median of 3 runs × 15 specimens) |
| Compliance | DIN 53516, ISO 4649, GB/T 9867, SATRA TM174, BS 903 |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | A1TDS-20A |
| Price | USD 21,800 (approx. based on ¥156,000 at 7.15 exchange rate) |
| Sample Capacity | 20 positions |
| Cold Trap Range | −35 °C to ambient |
| Primary Desorption Temp | up to 450 °C |
| Secondary Desorption Temp | up to 450 °C |
| Valve & Transfer Line Temp | up to 300 °C |
| Temperature Resolution | 1 °C |
| Temp Stability | ±0.5 °C |
| Recovery Rate | >99% (compound-dependent) |
| RSD | ≤2.5% (benzene at 0.05 μg) |
| Enrichment Time | 0–60 min |
| Injection Time | 0–60 min |
| Carrier Gas Flow Control | 0–100 mL/min (purge/flush), 0–160 mL/min (simulated sampling) |
| Sample Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| Interface | Motorized 6-port valve |
| Power Supply | 24 V DC for transfer line |
| Dimensions | 350 × 450 × 510 mm (W × D × H) |
| Weight | ~40 kg |
| Brand | Beifen Sanpu |
|---|---|
| Model | AAHS-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Sample Positions | 20 |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (optional to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Quantitative Loop Volume | 1 mL (customizable: 0.5 / 2 / 5 mL) |
| Vial Capacity | 10 mL or 20 mL (customizable: 50 / 100 mL) |
| Simultaneous Heating | 1 or 2 vials |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (continuously adjustable) |
| Communication Interface | USB |
| Compliance | ASTM D6866, ISO 17025-compatible operation, GLP/GMP-ready audit trail via software logging |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | AeTDS-20A |
| Price | USD 21,800 (FOB Beijing) |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | BFAHS-20A Plus |
| Sample Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL (customizable up to 100 mL) |
| Quantitation Loop Volume | 1 mL (optional: 0.5 / 2 / 5 mL) |
| Sample Heating Range | 40–220 °C (up to 300 °C optional), ±0.5 °C stability |
| Valve & Transfer Line Heating Range | 40–220 °C (up to 300 °C optional) |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Time Resolution | 1 ms |
| Carrier Gas Flow Control | EPC-compatible (optional) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Inert Flow Path | Deactivated fused-silica and stainless-steel tubing |
| Interface | USB |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AHS-20A Plus |
| Sample Capacity | 20-position |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (configurable up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | <±0.5 °C |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Loop Volume | 1 mL (customizable: 0.5 / 2 / 5 mL) |
| Vial Size Compatibility | 10 mL or 20 mL (customizable: 50 / 100 mL) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Clean Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| RSD | <1.0% (100 ppm ethanol in water) |
| Interface | USB |
| Valve Type | High-inertness 6-port valve with heated connection point |
| Transport Lines | Deactivated fused-silica capillary tubing |
| Drive Mechanism | Motor-driven (no external gas required) |
| Compliance | ASTM D3792, ISO 11843-2, USP <467>, EPA Method 502.2, 524.2, 8240, 8260] |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Model | AHS-20A Plus |
| Sample Capacity | 20 positions |
| Vial Size Compatibility | 10 mL and 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Oven Temperature Range | 40–220 °C (extendable to 300 °C on request), ±0.5 °C stability, 0.5% accuracy |
| Valve & Transfer Line Temperature Range | 40–220 °C (extendable to 300 °C), ±0.5 °C stability |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Clean Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Carrier Gas Flow Control | EPC-compatible (optional) |
| Rinse Flow Rate | 0–100 mL/min (adjustable) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB communication, GC trigger synchronization, external event input/output |
| Sample Handling | Motor-driven, gas-free operation |
| System Compliance | Designed for GLP/GMP environments |
| Brand | Beifen Sanpu |
|---|---|
| Model | AHSA-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Sample Positions | 20 |
| Sample Vial Capacity | 10 mL or 20 mL (customizable up to 100 mL) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 / 2 / 5 mL) |
| Sample Heating Range | 40–220 °C (extendable to 300 °C) |
| Valve & Transfer Line Heating Range | 40–220 °C (extendable to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Carrier Gas Flow Control | EPC optional |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Backflush Flow Rate | 0–100 mL/min (adjustable) |
| Interface | USB |
| Sample Handling | Liquid and solid matrices |
| Inert Flow Path | Deactivated fused-silica tubing and high-inertness valve components |
| Drive Mechanism | Motor-driven (no external gas required) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Beifen Sanpu |
|---|---|
| Model | AHSC-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Sample Positions | 20 |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (optional up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Quantitative Loop Volume | 1 mL (customizable: 0.5 / 2 / 5 mL) |
| Vial Capacity | 10 mL or 20 mL (customizable: 50 / 100 mL) |
| Simultaneous Heating | 1 or 2 vials |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Communication Interface | USB |
| Compliance | ASTM D6866, ISO 17025-compatible operation |
| Brand | Beifen Sanpu |
|---|---|
| Model | AHSD-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (configurable up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | <±0.5 °C |
| Pressure Range | 0–0.25 MPa (continuously adjustable) |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Quantitative Loop Volume | 1 mL (customizable: 0.5 / 2 / 5 mL) |
| Vial Capacity | 10 mL or 20 mL (customizable: 50 / 100 mL) |
| Sample Positions | 20 |
| Simultaneous Heating Zones | 1 or 2 |
| RSD (Ethanol in Water, 100 ppm) | <1.0% |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Communication Interface | USB |
| Compliance | ASTM D6866, ISO 17025-compatible operation |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region Category | Domestic (China) |
| Model | AHSE-20A Plus |
| Price | Upon Request |
| Sample Capacity | 20 positions |
| Vial Sizes | 10 mL or 20 mL (customizable up to 100 mL) |
| Quantitation Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 5 mL) |
| Oven Temperature Range | 40–220 °C (optional up to 300 °C), accuracy ±1 °C, stability <±0.5 °C |
| Valve & Transfer Line Temp Range | 40–220 °C (optional up to 300 °C), same accuracy/stability |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Interface | USB, GC-trigger synchronization, external event input/output |
| Compliance | Compatible with ASTM D6866, ISO 11843, USP <467>, and GLP/GMP workflows requiring audit-trail-capable instrument control |
| Brand | Beifen Sanpu |
|---|---|
| Model | AHSF-20A Plus |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Heating Range (Sample/Valve/Transfer Line) | 40–220 °C (configurable up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | <±0.5 °C |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Pressurization Time | 0–999 s |
| Purge/Clean Time | 0–30 min |
| Time Resolution | 1 ms |
| Quantitative Loop Volume | 1 mL (customizable: 0.5/2/5 mL) |
| Vial Capacity | 10 mL or 20 mL (customizable: 50/100 mL) |
| Sample Positions | 20 |
| Simultaneous Heating | 1 or 2 vials |
| RSD | <1.0% (100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Communication Interface | USB |
| Compliance | ASTM D6866, ISO 11843-2, USP <467>, FDA 21 CFR Part 11 (software-controlled audit trail optional) |