Other General Analysis Instruments
Filter
Showing 211–240 of 279 results
| Brand | PULUODY |
|---|---|
| Model | PMT-2DR |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Detection Range | 0.5–20.0 µm (standard) |
| Sensor Generation | 8th-Generation Dual-Laser Obscuration Sensor |
| Sampling Method | Precision Metering Piston Pump + Electromagnetic Flow Control |
| Accuracy | ±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Data Output | 4–20 mA analog interface with configurable particle concentration alarm |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Software (PC & tablet-compatible) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP-aligned environments |
| Brand | PULUODY |
|---|---|
| Model | PMT-2G |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Measurement Range | 0.1–0.5 µm (standard) |
| Resolution | 0.1 µm(c) minimum detectable size |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Output | 4–20 mA analog signal with configurable particle concentration alarm |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen UI) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Supports GLP/GMP audit trails, ASTM F3290 (for semiconductor process liquids), USP <788> & <789> (for insoluble particle assessment in polymer solutions) |
| Brand | PULUODY |
|---|---|
| Model | PMT-2GK |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.1–0.5 µm (standard), customizable to 1–100 µm or 4–70 µm (c) |
| Calibration Standards | JJG 1061, ISO 21501-4, Polystyrene Latex (PSL) Spheres |
| Sampling Method | Precision Metering Piston Pump |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output Interface | 4–20 mA analog output with configurable alarm relay |
| Data Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Analysis & Calibration Suite (PC + integrated touchscreen UI) |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2L |
| Price | USD 31,800 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Calibration Standards | JJG 1061, ISO 21501-4, Polystyrene Latex (PSL) Reference Spheres |
| Measuring Range | 1–450 µm |
| Customizable Sub-Ranges | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) resolution |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output | 4–20 mA analog signal with configurable alarm threshold |
| Data Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination codes |
| Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Software | V8.3 Integrated Analysis & Calibration Suite (PC & iPad-compatible) |
| Power Supply | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP-aligned environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PSD-PF100-1A-0.5 |
| Cleanroom Class | ISO Class 4 (10-grade) & ISO Class 5 (100-grade) |
| Airflow Configuration | Horizontal or Vertical Laminar Flow |
| Filtration | Dual-stage — Pre-filter + HEPA (H14, ≥99.995% @ 0.3 µm) |
| Operating Air Velocity | 0.25 m/s ±10% |
| Vibration Amplitude | ≤3 µm |
| Sound Pressure Level | ≤67 dB(A) |
| UV Germicidal Lamp | 254 nm, 15 W |
| Illumination | Fluorescent, ≥300 lx |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Ambient Temp. | 10–30 °C |
| Relative Humidity | ≤75% RH |
| Dimensions (W×D×H) | 360 × 450 × 580 mm |
| Construction | Powder-coated steel frame, 304 stainless steel work surface |
| Optional Accessories | High-purity nitrogen inlet with inline filter, articulated nitrogen purge nozzle, programmable bidirectional sample rotator |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PSD-PF10A-0.5 |
| Cleanliness Class | ISO Class 4 (10 particles ≥0.1 µm per cubic foot) |
| Airflow Velocity | 0.25–0.6 m/s (adjustable) |
| Vibration Amplitude | ≤3 µm |
| Noise Level | ≤67 dB(A) |
| UV Sterilization Time | 15 min for microbial reduction |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤75% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Brand | PULUODY |
|---|---|
| Model | PST-890 |
| Sensor Technology | 8th-Generation Dual-Laser Narrow-Beam Detection |
| Detection Range | 1–450 µm (optional 0.03–3000 µm) |
| Resolution | >95% (ChP 2015/2020 calibration), <10% (USP/ISO 21501 calibration) |
| Channel Count | 1000 adjustable channels (customizable from 4 to 128 size bins) |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Accuracy | ±3% typical |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Temperature Range (Fluid) | 0–80 °C |
| Software | V8.9 Integrated Analysis Suite with FDA 21 CFR Part 11 Compliance |
| Standards Compliance | ChP 0903, USP <788>/<789>/<797>, EP 10.0, ISO 21501, ISO 11171, GB/T 11446.9, GB 8368, NAS 1638, ISO 4406, ASTM D6786, and 510+ international pharmacopoeial & industrial standards |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PLD-GRS6 |
| Price | USD 6,700 (FOB) |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Detection Electrodes | Dual Platinum Electrodes |
| Control System | Embedded MCU with Purifier T8.0 Firmware |
| Measurement Range | 1 µg – 500 mg H₂O |
| Sensitivity | 0.1 µg |
| Accuracy | ±5% or ±1 µg (whichever is greater) |
| Sample Types | Liquids, Gases, and Solids (with optional oven adapter) |
| Analysis Time | 2–4 min per test |
| Endpoint Detection | Real-time dual-electrode current monitoring with auto-termination logic |
| Display | 20×2 LCD with date/time, electrolysis rate (µg/s), and cumulative water mass |
| Output | Integrated thermal printer (16-character line, auto-print of parameters & results) |
| Titration Cell Volume | 150 mL |
| Stirring | Built-in magnetic stirrer |
| Power Supply | 220 V ±10%, 50 Hz ±0.5 Hz |
| Power Consumption | 40 W |
| Operating Environment | 10–40 °C, ≤70% RH |
| Compliance Standards | GB/T 7600, GB/T 11133, GB/T 6283, SH/T 0207, SH/T 0246, SH/T 0255 |
| Origin | Europe |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | FireSting GO2 |
| Pricing | Available Upon Request |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | BAM |
| Stroke | 10 mm |
| Speed | 141 rpm |
| Load Range | 0.5 kg to 36 kg (9 calibrated weights) |
| Ceramic Pin | Ø10 × 15 mm |
| Ceramic Plate | 25 × 25 × 5 mm |
| Surface Roughness (Ceramic Plate) | 9–32 µm |
| Net Weight | 62 kg |
| Electrical Supply Options | 380 V / 3 Ph / 50 Hz |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | HPV |
| Pressure Vessel Material | AISI 316 Stainless Steel |
| Internal Diameter | 50 mm |
| Internal Height | 94.5 mm |
| Burst Disc Rating | 6.2 bar ±10% at 22 °C |
| Nozzle Orifice Diameters | 1.0, 2.0, 3.5, 6.0, 9.0, 12.0, 16.0, 24.0 mm |
| Compliance | UN Manual of Tests and Criteria, Part I, Section 12 (Test Series 1) |
| Accessories | Tripod Stand, Base Plate, Protective Sleeve, 8 Nozzle Plates, 20 Burst Discs |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model Designation | MV-TS 24-135 |
| Temperature Range | 60–140 °C |
| Control Accuracy | ±0.1 °C |
| Heating Block | 24-position anodized aluminum, 20.5 mm bore (19 mm per MIL-STD-286C), 280 mm depth |
| Sample Tubes | 24 × stainless steel cylindrical tubes, OD 20 mm (18 mm per MIL-STD-286C), ID 17 mm (15 mm per MIL-STD-286C), L 290 mm, with vented retaining clamps and stainless steel suspension hooks |
| Detection Medium | 200 pcs methyl violet impregnated indicator papers (N₂O-sensitive) |
| Temperature Sensor | PT100 Class A |
| Safety | Independent overtemperature cut-off device |
| Controller | Dedicated PID-based programmable temperature controller with isolated ISO-compliant housing |
| Display | Dual digital LED (setpoint & real-time temperature) |
| Power Supply | 230 V AC, 50–60 Hz |
| Power Consumption | 1500 VA |
| Cable Length | ~2 m |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | OXISTAR |
| Chamber Configuration | Single (310-0003) or Dual (310-0001) |
| Max Operating Pressure | 21 bar |
| Oxygen Pre-Pressure | 25 ± 1 bar |
| Compressed Air Pre-Pressure | 7 ± 0.5 bar |
| Burst Disc Rating | 32 ± 7.5% bar |
| Max Temperature | 150 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Temp Uniformity | ±0.1 °C at 70 °C, ±0.2 °C at 150 °C |
| Pressure Sensor Range | 0–25 bar, ±0.5% FS |
| Chamber Volume | 4 L per cavity |
| Heating Power (Single) | 330 VA |
| Total Power Consumption | 720 VA (Dual), 360 VA (Single) |
| Dimensions (W×D×H) | 87 × 66 (45) × 42 cm |
| Weight | 58 kg (Dual), 42 kg (Single) |
| Electrical Supply | 230 V ±10% |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | PVC |
| Heating Range | RT–210 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Block | 40-position, Ø5.2 × 65 mm wells |
| Temperature Sensor | PT100 |
| Controller | Digital PID |
| Sample Tubes | 100 pcs, Ø5 × 110 mm |
| Power Consumption | 500 W |
| Electrical Supply | 230 V / 50 Hz |
| Weight | 8.5 kg |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | Thermogravimetric Stability Tester |
| Max Operating Temperature | 110 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Block | Aluminum, 21-hole, Ø31 mm × 170 mm depth |
| Temperature Sensor | PT100 |
| Overtemperature Cut-off | 120 °C |
| Sample Tubes | 21 × cylindrical borosilicate glass tubes, Ø30 ± 0.3 mm × 230 ± 2 mm, ground neck with stopper |
| Optical Detection System | UV-A fluorescent lamp (365 nm), non-glaring, rigidly mounted on solid support |
| Electrical Supply | 230 V, 50–60 Hz |
| Power Consumption | 1200 VA |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | VP250 Lubricating Oil Evaporation Loss Tester |
| Temperature Range | 150–300 °C |
| Temperature Accuracy | ±0.2 °C (at 250 °C: ±0.1 °C) |
| Pressure Range | up to 21 mmWS |
| Pressure Accuracy | ±0.02 mmWS |
| Power Supply | 230 V/110 V ±10%, 50/60 Hz, 1300 VA |
| Max. Power Consumption | 950 VA at 250 °C |
| Dimensions | 278 × 316 × 300 mm |
| Net Weight | 18 kg |
| Display | LCD with 0.1 °C resolution for temperature, pressure, and elapsed time |
| Control System | Digital PID microprocessor with auto-tuning |
| Safety Features | Independent overtemperature cut-off circuit, dual-sensor redundancy, audible/visual fault alerts |
| Calibration | PT100 sensor calibrated against certified mercury thermometer (traceable to national standards), deviation <0.5 °C |
| Brand | Restek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Models | Over 1,000 Standard and Specialty Columns |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VM-82 |
| Pricing | Available Upon Request |
| Brand | Rocktek |
|---|---|
| Model | RTK-SGMC |
| Origin | Hubei, China |
| Measurement Principle | Infrared Bubble Volume Detection |
| Flow Range | 30 µL/h – 2 L/h |
| Minimum Detectable Volume | 30 µL |
| Accuracy | <1% FS |
| Sampling Frequency | Up to 1 Hz (1 sample/sec) |
| Operating Pressure Threshold | <300 Pa |
| Temperature & Pressure Compensation | Yes (converted to STP: 0 °C, 101.325 kPa) |
| Multi-Channel Capability | Up to 9 channels via single software instance |
| Gas Compatibility | All gases including corrosive species (e.g., H₂S, NH₃, Cl₂, HCl) and mixed gas streams |
| Output Interfaces | Digital (RS485/USB) and Analog (4–20 mA or 0–5 V) |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LR |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RQflex 20 |
| Price | Upon Request |
| Brand | Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | CA-S2000 |
| Price | Upon Request |
| Sample Capacity | 6 positions |
| Heating Method | PID-controlled constant-temperature water bath, acid/alkali-resistant one-piece bath tank |
| Heating Power | 1500 W |
| Nitrogen Flow Range | 10–800 mL/min per channel |
| Temperature Range | Ambient to 99.9 °C |
| Temperature Control Accuracy | ±1 °C |
| Reaction Vessel Volume | 500 mL |
| Inlet Nitrogen Pressure | 0.1 MPa |
| Independent Flow Control | Yes (6 channels) |
| Safety Features | Dual pressure relief valves |
| Timing Function | Programmable nitrogen purge duration with auto-shutoff |
| User Interface | Color TFT touchscreen, ergonomic sloped front panel |
| Auto-refill Function | Yes |
| Rack Material | High-temp, acid/alkali-resistant polymer |
| [Brand | Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | CA-T |
| Temperature Range | Up to 1700 °C |
| Chamber Volume | 4–20 L |
| Heating Element | Kanthal A1 resistance wire (≤1400 °C) / Silicon molybdenum (MoSi₂) rods (1700 °C) |
| Control System | Programmable PID controller, up to 60 segments |
| Temperature Uniformity | ±5 °C (at setpoint) |
| Sensor | K-type (≤1200 °C), S-type (≤1400 °C), B-type (≤1700 °C) |
| Power Supply | AC 220 V / 50 Hz (≤9 L) |
| Weight | 55–120 kg (model-dependent) |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CA-Z200 |
| Pricing | Upon Request |
| Heating Method | Far-infrared ceramic heating elements (domestic) |
| Endpoint Control | Time-based auto-stop, ±2 mL accuracy |
| Cooling System | Built-in compressor-based recirculating chiller, condenser temperature <30 °C |
| Display | 7-inch resistive color touchscreen |
| Heating Units | 6 independent channels, 1–800 W per unit (adjustable) |
| Ramp-up Time | 5–8 min |
| Sample Capacity | 1–6 samples, individually controllable |
| Total Rated Power | 4800 W (adjustable) |
| Distillation Rate | 8–12 mL/min |
| Anti-suckback Protection | Solenoid vacuum valve integrated |
| Timer Range | 0–999 min |
| Receiving Vessel Compatibility | Universal (volumetric flasks, Erlenmeyer flasks, graduated cylinders, beakers) |
| Power Input | Dual-input AC |
| Voltage/Frequency | 220 V / 50 Hz |
| Dimensions (L×W×H) | 1000 × 520 × 800 mm |
| Origin | Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SBA-40C |
| Pricing | Upon Request |
| Origin | Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SBA-40E |
| Pricing | Available Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SKP50200 |
| Pricing | Available Upon Request |
| Brand | Scientech |
|---|---|
| Origin | USA |
| Model | newopto |
| Readability | 0.01 mg to 0.1 g (model-dependent) |
| Warranty | 2 years |
| Compliance | NTEP-certified variants available (e.g., ZSP-NJ, ZSP-NP), ISO/IEC 17025-compatible operation |
| Regulatory Support | FDA 21 CFR Part 11–ready software options (via optional DataMaster Suite), GLP/GMP audit trail capable |
| Brand | SEAL |
|---|---|
| Origin | USA |
| Model | AQ300 |
| Instrument Type | Discrete Analytical System |
| Sample Throughput | Up to 97 positions |
| Cuvette Pathlength | 10 mm |
| Optical Cell | Fixed-position fused quartz cuvette |
| Detection Principle | Photometric absorbance measurement |
| Reaction Control | Programmable incubation (seconds to minutes) |
| Compliance | EPA-approved methods, UK Blue Book validated, GLP/GMP-ready architecture |
| Automation Level | Fully unattended overnight operation |
| Reagent Consumption | Optimized for low-volume reagent use |
| Cross-contamination Mitigation | Post-measurement deep-cuvette wash cycle |
| Method Flexibility | Up to 7 analytes per sample, auto-standard curve generation, on-the-fly dilution and method switching |
| Brand | SEAL |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Minilab 1200 BOD |
| Pricing | Available Upon Request |