Other General Analysis Instruments
Filter
Showing 121–150 of 279 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HD Rocksand |
| Pricing | Available Upon Request |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HSZ-1A |
| Temperature Range (Steam Generator Furnace & Constant-Temperature Connection Band) | Ambient to 200 °C |
| Temperature Measurement Accuracy | ±0.1 °C |
| Liquid Water Feed Rate | 0.011–10 mL/min |
| Generated Steam Flow Rate | 50–200 mL/min |
| Carrier Gas Flow Control | 10–200 mL/min (via Mass Flow Controller) |
| Steam Delivery Method | Inert Gas-Carried |
| Construction Materials | 304 Stainless Steel Vaporization Chamber |
| Heating Method | Sheathed Heating Element with K-Type Thermocouple Feedback |
| Insulation & Heating Integration | High-Temp Fiber-Wrapped Composite Band with Embedded Heating Elements and Corrosion-Resistant Metal Inner Tube |
| Gas Conduit Material | High-Temperature PTFE Tubing |
| Connection Fitting | Precision-Machined All-Metal Sealed Interface |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | ICP-AES |
| Pricing | Upon Request |
| Detection Limit | as low as 0.7 ppb (e.g., Ba, Cu) |
| Linear Dynamic Range | 6 orders of magnitude |
| Wavelength Range | 180–800 nm |
| Resolution | up to 0.002 nm |
| RF Output Stability | ≤0.2% |
| Short-term Precision (RSD) | ≤1.5% |
| Long-term Stability (RSD) | ≤2% |
| Nebulization Efficiency | 65% |
| Torch Design | Miniature concentric quartz torch (15 mm ID, 3-turn coil) |
| Nebulizer Chamber | Cyclonic or double-pass spray chamber |
| Optical System | Czerny-Turner mounting with large-area ion-etched plane holographic grating |
| Focal Length | 1000 mm |
| Temperature Control | Programmed thermostatic stabilization ±0.1°C |
| Brand | SGM |
|---|---|
| Origin | Beijing, China |
| Model | HG-C, HG-B |
| Pump Type | Single-channel peristaltic pump |
| Sample Introduction Mode | Continuous-flow hydride generation (flame-compatible) |
| Compatible Instruments | Universal interface for domestic and international atomic absorption spectrometers (AAS) |
| Memory Function | Onboard parameter retention across power cycles |
| Startup | One-button automated initialization |
| Detection Sensitivity (Hg) | ≥0.055 A at 5 ng/mL standard |
| Detection Sensitivity (As) | ≥0.055 A at 2 ng/mL standard |
| Precision (RSD) | ≤2% at 6 ng/mL As standard |
| Linearity (r²) | >0.998 for As calibration curve |
| Compliance | Designed to meet ASTM D3559, ISO 11929 (uncertainty evaluation), and USP <233> hydride-generation method requirements |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | ABR |
| Operating Pressure Range | 0.1–50 bar (configurable) |
| Temperature Control Range | 0–300 °C |
| Temperature Stability | ±0.025 °C |
| Flow Rate Range | 3–1000 mL/min |
| Sample Bed Volume | 2 cm³ (interchangeable) |
| Mass Spectrometer | Hiden DSMS, m/z 1–200 amu, response time ≤200 ms |
| Vacuum Option | UHV pump station (1×10⁻⁸ mbar) |
| Compliance | Fully compatible with GLP/GMP data integrity requirements |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | Proteus |
| Port Configurations | 20 / 40 / 80 (customizable) |
| Operating Pressure Range | 10 mbar to 2 bar |
| Flow Rate Range | 0.01–10 L/min |
| Actuation | Direct-drive high-torque micro-stepping motor with incremental rotary encoder |
| Positioning Feedback | Closed-loop Z-axis localization |
| Motion Profile | Bidirectional travel with intelligent acceleration/deceleration and endpoint holding |
| Sealing Endurance | >6 × 10⁶ cycles |
| Temperature Control | Integrated heater and sensor, up to 120 °C |
| Dead Volume | Minimized for rapid response |
| Memory Effect | Negligible |
| Compatibility | Designed for seamless integration with HPR20 QMS and other analytical gas systems |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XBS |
| Pricing | Upon Request |
| Ion Source | Crossed-beam, ±35° acceptance angle, 2 mm aperture |
| Detection Limit | 30 ions/s (for molecular beam studies) |
| Mass Range | 0–510 amu |
| Sensitivity | 100% down to 5 ppb |
| Long-term Stability | < ±0.5% peak height drift over 24 h |
| Cooling | Integrated UHV-compatible water-cooled shield |
| Ionization | Tunable electron energy for soft ionization and appearance potential mass spectrometry |
| Signal Enhancement | RF-assisted primary filtering for improved high-mass transmission |
| Interface | RS232, RS485, Ethernet |
| Software | MASsoft™ for Windows® with automated mass list generation and real-time process control |
| Brand | Binzhenghong |
|---|---|
| Model | DBF-II |
| Heating Surface | 600 × 400 mm |
| Construction Material | High-Grade Cast Aluminum |
| Operating Temperature Range | Ambient to 350 °C |
| Temperature Control Method | Digital PID with LED Display |
| Temperature Accuracy | ±1 °C |
| Surface Uniformity | ≤ ±2 °C across active area |
| Continuous Operation Duration | ≥ 48 h |
| Compliance | Designed for laboratory-grade chemical processing under GLP-aligned workflows |
| Customization Options | Modular split-body configuration, multi-stage timed ramp/soak profiles, custom surface dimensions |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | LSA-245 |
| Price | Upon Request |
| Wavelength Range | 350–1100 nm (standard), 200–1100 nm (UV option) |
| Measurement Accuracy | ±5 pm @ 633 nm |
| Sensitivity | 5 nJ @ 633 nm |
| Maximum Spectral Span (High-Resolution Mode) | λ/30 |
| Spectral Finesse | 30,000 (single-mode fiber), 15,000 (50 µm multimode fiber) |
| First-Order Resolution | 1 nm |
| Relative Linewidth Measurement Accuracy | ±5 × 10⁻⁶ (single-mode fiber) |
| Repetition Rate Capability | Up to 100 Hz |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-268 |
| Pricing | Available Upon Request |
| Measurement Range | NaOH: (0–5.00) wt% |
| H₂SO₄ | (0–5.00) wt% |
| HCl | (0–10.00) wt% |
| NaCl | (0–5.00) wt% or (0–10.00) wt% (custom ranges available upon request) |
| Accuracy | ±1.5% of Full Scale (F.S.) |
| Measured Media | Aqueous solutions of HCl, NaOH, H₂SO₄, NaCl (specified at order) |
| Temperature Compensation Range | 0–55 °C |
| Display | 4-digit, 0.8-inch LED |
| Power Supply | 220 V AC via external power adapter (~5 W) |
| Dimensions (L×W×H) | 350×230×120 mm |
| Weight | 1.5 kg |
| Sensor Probe | Ø39×100 mm |
| cable length | 1 m |
| Brand | SGM |
|---|---|
| Origin | Beijing, China |
| Model | KY-PE |
| Designed Compatibility | PerkinElmer Atomic Absorption Spectrometers |
| Rated Lifetime | ≥5000 mAh (most elements), ≥3000 mAh (low-melting-point elements) |
| Intensity Noise | <0.1% RMS |
| Drift Stability | ≤1% over 30 min after 30-min warm-up |
| Spectral Background at Analytical Line | ≤1% |
| Brand | SGM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | HG-B |
| Price | USD 2,350 (approx.) |
| Brand | SGM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ICP Nebulizer |
| Price | USD 140 (approx.) |
| Nebulization Uptake Rate | 0.1 mL/min |
| Capillary Cross-Sectional Area | 0.03 mm² |
| Torch Compatibility | Standard ICP-OES/ICP-MS Quartz Torches |
| Material | High-Purity Quartz or Corrosion-Resistant Alloy (configurable) |
| Operating Pressure Range | 0.1–0.3 MPa (gauge) |
| Recommended Carrier Gas | Argon (≥99.998% purity) |
| Brand | SGM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Price Range | USD 140 – 425 (FOB) |
| Brand | SGM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ICP |
| Price | USD 195 (FOB Beijing) |
| Operating Temperature | Up to 10,000 K |
| Material | High-Purity Quartz (≥99.99% SiO₂) |
| Inner Diameter | 2.0 mm |
| Middle Tube ID | 12.0 mm |
| Outer Tube ID | 22.0 mm |
| Wall Thickness | 1.0–1.2 mm |
| Thermal Shock Resistance | ≥5 thermal cycles from 25 °C to 800 °C without cracking |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | Multi-Port Sampling Device |
| Valve Configurations | 2-way and 3-way |
| Port Options | 12-, 16-, 18-, or custom-configurable inlet ports |
| Material Options | PTFE- or PEEK-coated valve bodies |
| Application | Automated, sequential vapor/sampling stream selection for real-time analytical systems |
| Compliance | Designed for integration with PTR-MS, SIFT-MS, and other trace gas analyzers |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Model | Nasal Sampling Probe |
| Compatibility | PTR-MS systems |
| Heated | Yes |
| Response Time | < 100 ms |
| Application | Real-time human nasal inhalation monitoring for VOC and odorant analysis |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AMI 400TPx |
| Pricing | Upon Request |
| Core Functionality | Fully Automated TPD, TPR, TPO, TPSR, Pulse Chemisorption, Single-Point BET, Optional MS/GC/FID/FTIR Coupling |
| Gas Compatibility | Inert, Reducing (H₂), Oxidizing (O₂, NO, CO₂), Corrosive (SO₂, H₂S) |
| Control Architecture | Integrated Pneumatic Valve Manifold with Real-Time Flow Path Visualization |
| Software | Proprietary ChemiSoft™ with Live System Status Dashboard, Parameter Logging, and Audit-Trail-Ready Data Export |
| Brand | Karrie |
|---|---|
| Model | CX-A |
| Measurement Principle | Dielectric Constant Method |
| Standards Compliance | GB/T 18339–2001 |
| RON Range | 84.5–99.9 |
| MON Range | 63.0–80.0 |
| Repeatability (RON) | ±0.3 |
| Reproducibility (RON) | ±0.6 |
| Resolution | 0.1 RON |
| Response Time | 1 s |
| Display | LCD with thermal printer interface |
| Power Supply | AC 220 V, 50 Hz / DC 4.8 V (rechargeable Ni-MH battery) |
| Dimensions | 275 × 200 × 85 mm |
| Weight | 1.6 kg |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 2DMax1100A1 / 2DMax1100P1 |
| Flow Rate Range | 0–200 mL/min (customizable higher flow available) |
| Maximum Pressure | 0–4000 psi with overpressure protection |
| UV-Vis Detection Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection), wavelength accuracy: ±0.2 nm |
| Light Source | Deuterium lamp + Tungsten lamp |
| Autosampler Capacity | 144 vials (sealed vial design with needle wash function) |
| Fraction Collector (2DMax1100P1 only) | 160 positions, 15 mm tube diameter |
| Software Platform | Windows 7/10 (64-bit) |
| Communication Interface | Ethernet |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 2DMax1100A2 / 2DMax1100P2 |
| Flow Range | 0–200 mL/min (customizable up to higher rates) |
| Maximum Pressure | 4000 psi with overpressure protection |
| UV-VIS Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection), wavelength accuracy: ±0.2 nm |
| Light Source | Deuterium lamp + Tungsten lamp |
| Autosampler Capacity | 144 vials (sealed vial design with needle wash function) |
| Fraction Collector (2DMax1100P2 only) | 160 positions, 15 mm tube diameter |
| Software Platform | Windows 7/10 (64-bit) |
| Communication Interface | Ethernet |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 2DMax1100A3 / 2DMax1100P3 |
| Price | Upon Request |
| Pump Flow Range | 0–200 mL/min (customizable higher flow available) |
| Maximum Pressure | 4000 psi with overpressure protection |
| UV-Vis Detector Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection), wavelength accuracy: ±0.2 nm |
| Light Source | Deuterium lamp + Tungsten lamp |
| Autosampler Capacity | 144 vials (sealed vial design with needle wash function) |
| Fraction Collector (2DMax1100P3 only) | 160-tube rack, 15 mm tube diameter |
| Software Platform | Windows 7/10 (64-bit) |
| Communication Interface | Ethernet |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | 2DMax1500A1 / 2DMax1500P1 |
| TLC Plate Max Size | 200 × 200 mm |
| Laser Power | 5 mW |
| Sealing Force | Up to 500 N |
| Solvent Flow Rate (Extraction) | 0.05–0.3 mL/min |
| Extraction Probe Options | Ø4 mm, Ø5 mm circular |
| HPLC Flow Range | 0–100 mL/min (customizable) |
| Pressure Range | 0–10,000 psi (A1) / 0–4,000 psi (P1) |
| UV-VIS Detection | Four simultaneous wavelengths, 190–900 nm |
| Wavelength Accuracy | ±0.2 nm |
| Monochromator | 1200-line grating |
| Light Source | Deuterium–Tungsten dual lamp |
| Quantitation Loop | 20 µL (A1) / 2 mL (P1) |
| Autosampler | Integrated |
| Fraction Collector Capacity | 160 positions |
| Gradient Composition | 0–100% linear A:B |
| Software Platform | Windows 7/8/10 |
| Communication Interface | Ethernet |
| Power Supply | 110–220 V AC, 500 W |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | 2DMax1500A2 / 2DMax1500P2 |
| TLC Plate Max Size | 200 × 200 mm |
| Laser Power | 5 mW |
| Seal Force | up to 500 N |
| Solvent Flow Rate (Extraction) | 0.05–0.5 mL/min |
| Extraction Probe Options | Ø4 mm, Ø5 mm circular |
| HPLC Flow Range | 0–100 mL/min (customizable) |
| Pressure Range | 0–10,000 psi |
| UV-VIS Detection Wavelength Range | 190–900 nm (quad-wavelength simultaneous detection) |
| Wavelength Accuracy | ±0.2 nm |
| Monochromator | 1200 lines/mm grating |
| Light Source | Deuterium–Tungsten dual lamp |
| Quantitative Loop | 20 µL (customizable) |
| Autosampler | Integrated |
| Fraction Collector Capacity | 160 positions |
| Gradient Composition Range | 0–100% linear A:B |
| Software Platform | Windows 7/8/10 |
| Communication Interface | Ethernet |
| Power Supply | 110–220 V AC, 500 W |
| Gas Supply | Nitrogen or compressed air |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RHC020 |
| Pricing | Upon Request |
| Probe Options | 2 mm & 50 µm |
| Work Function Resolution | 1–3 meV (2 mm probe), 5–10 meV (50 µm probe, on optical vibration isolation table) |
| Max Scan Area | 50 mm × 50 mm |
| Positioning Resolution | 318 nm |
| Z-Axis Tracking | Auto-gap control with manual coarse adjustment (25.4 mm KP translation stage) |
| Zero-Crossing Signal Detection | Integrated parasitic capacitance suppression |
| Sample Heater | 50 mm × 50 mm, up to 100 °C |
| RH Control Range | 10–100 % RH, ±1 % accuracy (optional) |
| Temperature Control | Closed-loop PID |
| Probe Mount | Direct-insert holder compatible with 2 mm to 50 µm probes |
| Optional Modules | SPV020 Surface Photovoltage, SPS030 Spectral Photovoltage |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | UHV-KP020 |
| Price | Upon Request |
| Work Function Resolution | 1–3 meV (with 2–10 mm probe) |
| Probe Diameter Customizable | 2–10 mm |
| Probe Length Customizable | Flange-to-sample distance |
| Vacuum Port | DN40 (2.75″ CF), other sizes optional |
| Manual Translation Stage | 50 mm (100 mm optional) |
| Base Pressure | ≤2×10⁻¹¹ mbar |
| Distance Control | Active electro-mechanical tracking system |
| Capacitance Nulling | Zero-crossing signal detection circuitry |
| Optional Accessories | Motorized translation stage, UHVSKP upgrade kit, Surface Photovoltage modules SPV020 & SPS030 |
| Brand | LABTECH (Distributed by Jinhengxiang/JHX) |
|---|---|
| Origin | Czech Republic |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | LTX Unique |
| Pricing | Available Upon Request |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ERT-01 |
| Pricing | Available Upon Request |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | YH-1 |
| Measurement Range | ±6 mm |
| Resolution | 0.01 mm |
| Accuracy | ±0.015 mm |
| Contact Probe Diameter | Φ10 mm |
| Display Type | Analog Pointer Dial |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Model | 916 Ti-Touch |
| Electrode Interfaces | 2 working electrode ports |
| Dosing Channels | 2 independent dosing units |
| Connectivity | Built-in Ethernet & LIMS interface (no PC required) |
| Report Output | Auto-generated PDF reports saved to USB drive |
| Sample Handling | Optional automated sample processor with interchangeable rotor trays (e.g., 12-, 24-, or 48-position) |
| Stirring Control | Adaptive speed adjustment based on sample viscosity |
| Dosing Technology | Dosino TMDosino™ multi-dose module — reagent cartridge replacement without disassembly or operator contact |
| Regulatory Compliance | Full GLP/GMP traceability |