| Brand | Distek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LabEye |
| Pricing | Upon Request |
| Brand | DITECT |
|---|---|
| Origin | Japan |
| Model | PIV 2D2C, PTV 2D2C (2D/3D), PIV 2D3C (3D) |
| Measurement Capability | 3D3C volumetric velocity field reconstruction |
| Frame Rate Support | ≥100 Hz |
| Supported Image Formats | AVI, WMV, JPG, BMP, TIFF, PNG |
| Data Export Formats | Project (.flw), CSV |
| Correlation Method | Direct Cross-Correlation (PIV), Binary Correlation (PTV) |
| Physical Quantities Computed | Vorticity, Turbulent Kinetic Energy, Reynolds Stresses, Velocity Gradient Tensor, RMS Velocity Fluctuations |
| Operating System | 64-bit Windows with SSE2/SSE3 instruction set support |
| CPU Architecture | Multi-core parallel processing optimized |
| Brand | DJB |
|---|---|
| Origin | Germany |
| Model | DJB A-Series Single-Axis Industrial Accelerometer |
| Sensitivity Range | 1.7–250 pC/g (IEPE/charge-output variants) |
| Mass | 20–150 g |
| Maximum Shock Resistance | 1000 g (peak) |
| Resonant Frequency | 8–18 kHz |
| Operating Temperature Range | −50 °C to +400 °C (HT variants) |
| Connector Options | Integrated hardwired cable, 2-pin 7/16 UNF, MIL-C-5015, or %-28 UNF |
| Mounting | Through-hole |
| Compliance | Designed for industrial vibration monitoring per ISO 5347, IEEE 1451.4 (TEDS-ready variants), and compatible with standard IEPE signal conditioners |
| Brand | DJB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A/131/V |
| Price | Upon Request |
| Sensitivity | 10 mV/g or 100 mV/g |
| Weight | 19 g |
| Maximum Shock Range | ±1000 g |
| Resonant Frequency | ≥25 kHz (X/Y), ≥28 kHz (Z) |
| Operating Temperature | −50 °C to +125 °C (High-Temp Version: ±10% sensitivity shift at +185 °C) |
| Connector | Microdot (M) |
| Mounting | Through-hole or adhesive (isolated base) |
| Electrical Output | IEPE (Integrated Electronics Piezoelectric), Constant Current Powered (2–20 mA) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | FM-120 |
| Measurement Range | 2–50 µm |
| Sampling Area | 0.24 mm² |
| Volumetric Flow Rate | 1 m³/min |
| Sampling Frequency | Adjustable from 0.04 s to 20 s |
| Refractive Index Assumption | 1.33 (non-absorbing, water standard) |
| Scattering Collection Angle | 3.5°–12° (annular forward cone) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | 0–100 % RH (non-condensing) |
| Altitude Limit | ≤ 4,000 m |
| Instrument Weight | 10.0 kg |
| External Pump Weight | 9.5 kg |
| Dimensions (Detector Unit) | 23 cm (W) × 37 cm (L) × 28 cm (H) |
| Power Supply | FM-120 unit: 85–264 VAC, 50–60 Hz |
| External pump | 220 VAC |
| Data Interface | RS-422 or RS-232 |
| Brand | AccuStar® II |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DAS30 |
| Price | Upon Request |
| Measurement Principle | Capacitive Transduction |
| Output Type | Linear Variable Capacitance |
| Mounting | PCB-mountable |
| Housing Structure | Patented Arch Design |
| Operating Temperature Range | −40 °C to +85 °C |
| Storage Temperature Range | −55 °C to +85 °C |
| Full Scale Range | ±30° |
| Linearity Error | ±20 arc-min (±0.33°) over full scale |
| Sensitivity (Gain) | 0.27% per degree ±0.007% |
| Zero Offset Drift | ±0.025°/°C |
| Zero Offset at 25 °C | ±18 arc-seconds |
| Temperature Coefficient of Sensitivity | −0.10%/°C ±0.15% |
| Bandwidth | <3 kHz |
| Nominal Capacitance | Cs ≈ 50 pF |
| Output Monotonicity | Strictly monotonic |
| Environmental Robustness | IP67-rated enclosure (per IEC 60529), shock resistance up to 500 g (half-sine, 1 ms), vibration tolerance 20 g RMS (10–2000 Hz) |
| Detector Type | Ventilated parallel-plate ionization chamber |
|---|---|
| Environmental Rating | Waterproof, ventilated, fully guarded, non-perturbing |
| Applicable Radiation Quality | 70–250 MeV protons |
| Field Size Range | 3–10 mm diameter |
| Polarity Effect | <1% |
| Nominal Response | 325 nC/Gy (in air, under ⁶⁰Co beam) |
| Outer Dimensions | 120–150 mm diameter × 10–15 mm height |
| Sensitive Volume Dimensions | 58.0 mm diameter × 2 mm depth |
| Entrance Window Thickness | 0.1 mm insulating paint + 0.5 mm PMMA + 0.02 mm graphite electrode |
| Exit Window Thickness | 1.16 mm |
| Collecting Electrode Position | distal to entrance window |
| Collecting Electrode Diameter | 57.6 mm |
| Sensitive Volume | 5.2 cm³ |
| Sensitive Area | 25.1 cm² |
| Guard Ring Width | 4 mm |
| Nominal Operating Voltage | 400 V (max ±500 V) |
| Leakage Current | ≤ ±100 fA |
| Ion Collection Efficiency at Nominal Voltage | ion collection time = 67 µs |
| Maximum Dose Rate | 21 Gy/s (99.5% saturation), 42 Gy/s (99.0% saturation) |
| Maximum Dose per Pulse | 0.9 mGy (99.5% saturation), 1.8 mGy (99.0% saturation) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ABS Series for Aeration Monitoring |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Dynaflow ABS |
| Price Range | USD 14,000 – 70,000 |
| Brand | Edmund Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 114 |
| Price | Upon Request |
| Wavelength Range | 300–1100 nm (400–1100 nm with LDFP) |
| Sensor Format | 2/3″ CMOS, 1280 × 1024 pixels, 6.7 µm pixel pitch |
| Active Area | 8.5 × 6.8 mm |
| Minimum / Maximum Beam Diameter (1/e²) | 0.20 mm / 6.0 mm |
| Beam Position Accuracy | ±1% typical, ±5% max |
| Trigger Input | TTL, rising or falling edge |
| Frame Rate | 27 Hz (Live Mode), 10 Hz (with real-time calculations) |
| Peak Noise Floor | 24 nW/cm² at 632.8 nm |
| CW Saturation Power Density | 40 mW/cm² at 632.8 nm (with LDFP) |
| Pulsed Saturation Energy Density | 8 mJ/cm² at 1.06 µm (without LDFP) |
| Damage Threshold | 32 mJ/cm² at 1.06 µm (without LDFP) |
| Shutter | Fixed 10 ms |
| Lens Mount | C-Mount |
| SNR | >60 dB |
| Gamma | 1.0 |
| Gain | Optimized linear dynamic range (non-adjustable) |
| OS Compatibility | Windows 98, NT 4.0, 2000, XP |
| Dimensions (with LDFP) | 68.1 × 79.3 × 40.9 mm |
| Weight | 110 g |
| Operating Temperature | −20 to +60 °C |
| Brand | Edwards Vacuum |
|---|---|
| Origin | United Kingdom |
| Model | APG 200 |
| Measurement Principle | Pirani Thermal Conductivity |
| Pressure Range | 1 × 10⁻⁴ to 1 × 10⁴ mbar |
| Vacuum Interface | KF 16 (ISO-KF) |
| Compliance | CE, RoHS, UKCA |
| Brand | Eijkelkamp |
|---|---|
| Model | DIVER (DI601/DI602/DI605/DI610, CTD-Diver, Micro-Diver) |
| Type | Submersible Pressure-Based Water Level Sensor |
| Measurement Parameters | Water Level (Depth), Temperature (±0.1 °C), Optional Conductivity (CTD-Diver: 0–80 mS/cm, ±1% FS) |
| Depth Ranges | 10 m / 20 m / 30 m / 50 m / 100 m (model-dependent) |
| Resolution | 0.2–2 cm (level), 0.01 °C (temperature), 0.1% FS (conductivity) |
| Accuracy | ±0.05–0.1% FS (level), ±0.1 °C (temperature), ±1% FS (conductivity) |
| Operating Temperature | −20 to +80 °C |
| Housing Material | RVS 316L stainless steel (Micro-/DIVER) or Zirconia ceramic (CTD-Diver) |
| Pressure Sensor Element | Alumina ceramic |
| Dimensions | Ø18 mm × 90 mm (Micro-/DIVER) |
| Weight | 60 g (Micro-/DIVER) |
| Memory Capacity | 2 × 48,000 readings (Micro-/DIVER) |
| Sampling Interval | 0.5 s to 99 h (adjustable) |
| Battery Life | 8–10 years (typical, at 15-min interval) |
| Temperature Compensation Range | −10 to +40 °C (for pressure sensor) |
| Atmospheric Compensation | Compatible with Baro-Diver for barometric correction |
| Compliance | Designed for long-term unattended deployment in compliance with ISO 14688-1 (soil description), ASTM D4043 (groundwater monitoring), and GLP-aligned data integrity practices |
| Origin | Japan |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | EJ Series |
| Pricing | Upon Request |
| Brand | Electrophysics |
|---|---|
| Origin | Belarus |
| Model | Abris-M Version 2 |
| Spectral Range | 350–2000 nm (UV/IR) |
| Resolution (center wavelength) | 60 lp/mm |
| Field of View | 18° |
| Magnification | 2× |
| Objective Lens | F2/50 mm with adjustable iris |
| Focus Range | 0.25 m to ∞ |
| Working Distance | 12.5 ± 0.2 mm |
| Battery | 1.5 V AAA (3 V internal HV conversion) |
| HV Output | 16–18 kV |
| Phosphor Emission | ~550 nm (green) |
| Screen Non-Uniformity | <20% |
| Response Non-Uniformity | <15% |
| Image Distortion | <18% |
| Battery Life | ~35 h |
| Weight | 0.55 kg |
| Dimensions | 205 × 78 × 52 mm |
| Operating Temperature | −10 °C to +40 °C |
| Mounting Thread | 1/4″-20 UNC |
| Compliance | CE, RoHS, IEC 61010-1 (safety), ISO 9001-manufactured supply chain |
| Brand | Axetris |
|---|---|
| Origin | Switzerland |
| Model | EMIRS50 |
| Housing | TO-46 metal can |
| Emissivity | >0.95 (2–14 µm) |
| Spectral Range | 2–14 µm |
| Modulation Speed | DC to >100 Hz |
| Power Consumption | <120 mW (typ.) |
| Window Options | Sapphire or Barium Fluoride (BaF₂) |
| Operating Temperature | -40 °C to +85 °C |
| Lifetime | >50,000 hours (at rated power) |
| Brand | ESSA |
|---|---|
| Origin | Imported (Non-China) |
| Manufacturer Type | Authorized Distributor |
| Model | ESSAY-3 |
| Price | Upon Request |
| SAR Probe Frequency Range | 10 MHz – 10 GHz |
| Probe Spatial Resolution | ≤ 25 mm³ |
| Probe Dynamic Range | 2 mW/kg – 100 W/kg |
| Robot Position Repeatability | < 0.01 mm |
| SAM Phantom Compliance | IEEE Std 1528-2003 / IEC 62209-1 |
| Angular Isotropy | ±0.2 dB |
| Probe Impedance | ≈2 MΩ |
| Dipole Length | 2.0 mm |
| Tip O.D. | 4.0 mm |
| Offset | 2.0 mm |
| Robot Payload Capacity | 6 kgf |
| Robot DOF | 6-axis vertically articulated |
| Motor Type | DC servo |
| Robot Weight | 58 kg |
| Flat Phantom Dimensions | 42 cm × 36 cm × 19 cm |
| Phantom Shell Thickness | 2.0 mm ± 0.2 mm |
| Phone Fixture Angular Tolerance | ±1° |
| Fixture Material | εᵣ < 5, tanδ ≤ 0.05 |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Distributor Type | General Distributor |
| Import Status | Imported |
| Model | Not Specified |
| Price Range | USD 420 – 690 |
| Brand | EverACQ Technologies |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | μXI-X3658 |
| Pricing | Upon Request |
| Brand | Exail |
|---|---|
| Origin | France |
| Model | PSW-LN-0.1 |
| Operating Wavelength | 1550 nm (standard), optional 1300 nm |
| Switching Frequency | up to 200 MHz |
| Substrate | Z-cut LiNbO₃ waveguide |
| Input/Output Polarization Alignment | Matched to PM fiber slow/fast axes |
| Insertion Loss | < 2.5 dB |
| Half-wave Voltage (Vπ) | < 4 V RF (typ. at 1550 nm) |
| Differential Group Delay (DGD) | < 0.5 ps |
| RF Input Impedance | 50 Ω |
| Operating Temperature | −5 °C to +70 °C |
| Storage Temperature | −40 °C to +85 °C |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FD-M Series |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IRV84499C |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IRV84499C2X |
| Pricing | Upon Request |
| Brand | N/A |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Finger-Type Ionization Chamber |
| Pricing | Upon Request |
| Energy Range (Photons) | 7.5 keV – 420 keV |
| Maximum Measurement Volume | 17.6 cm³ |
| Nominal Operating Voltage | 400 V |
| Leakage Current | ≤1 pA |
| Chamber Wall Material | Triple-layer polyimide (0.5 mm per layer, density 1.42 g/cm³ |
| Electrode Material | Polyimide |
| Maximum Continuous Dose Rate (99% saturation) | 17 Gy/s |
| Maximum Continuous Dose Rate (99.5% saturation) | 8.5 Gy/s |
| Maximum Pulsed Dose Rate (99% saturation) | 1.18 mGy/pulse |
| Maximum Pulsed Dose Rate (99.5% saturation) | 0.59 mGy/pulse |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | General Distributor |
| Product Origin | Domestic |
| Model | Flat Panel Ionization Chamber |
| Quotation | Upon Request |
| Detector Type | Ventilated Parallel-Plate Ionization Chamber |
| Sensitive Volume | 10 cm³ ±10% or 2.5 cm³ ±10% |
| Sensitive Volume Dimensions | 10 cm³: radius 40 mm, depth 2 mm |
| 2.5 cm³ | radius 20 mm, depth 2 mm |
| Design | Waterproof, ventilated, fully guarded ionization chamber |
| Nominal Operating Voltage | ±400 V (max ±500 V) |
| Leakage Current | ≤ ±10 fA |
| Entrance Window (10 cm³) | 3.35 mm PMMA + 0.02 mm graphite |
| Entrance Window (2.5 cm³) | 1 mm PMMA + 0.02 mm graphite |
| Areal Density of Total Window | 10 cm³: 420 mg/cm² |
| 2.5 cm³ | 140 mg/cm² |
| Long-Term Stability | ≤1% per year |
| Electrical Interface | TNC connector |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster®-Mitas |
| Measurement Domain | Planar (2D/3D) |
| Measurement Frequency | Low-Frequency |
| Velocity Range | 0–20 m/s |
| Accuracy | ±1% |
| Measurement Field Size | 0–1 mm |
| Microscope Objective Magnification | 5×–40× |
| CCD Resolution | 1376 × 1040 pixels |
| Quantum Efficiency | 65% @ 500 nm |
| Interframe Time (min) | 500 ns |
| Spatial Resolution (XYZ Stage) | 0.05 µm |
| Positioning Accuracy (XYZ Stage) | ±3 µm |
| Travel Range (X/Y) | 120 mm |
| Travel Range (Z) | 20 mm |
| Sample Opening | 84 × 70 mm |
| Brand | A2 Photonic Sensors |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | B/S POP |
| Pricing | Available Upon Request |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Model | Flow Unit |
| Flow Range Options | 7 nL/min to 5 mL/min |
| Accuracy | 5–20% MV (varies by range and flow rate) |
| Detection Limit | 3.7 nL/min (XS) to 3 µL/min (XL) |
| Max Pressure | 200 bar (XS/S), 100 bar (M), 12 bar (L), 5 bar (XL) |
| Channel ID | 25 µm to 1.8 mm |
| Construction | PEEK & Fused Silica |
| Compatible Media | Water, Isopropanol |
| Interface | Analog (0–5 V / 4–20 mA) & Digital (I²C, SPI) |
| Supported Platforms | FLOWBOARD (up to 8 units), Flow-EZ, AIO Software |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | DaqPRO 5300 |
| Pricing | Available Upon Request |
| Brand | Geonica |
|---|---|
| Origin | Spain |
| Model | DataRain-4000 |
| Measurement Principle | Electronic weighing (load cell-based) |
| Rainfall Rate Range | 0.01–500 mm/h |
| Accuracy | ±1% of full scale across entire range |
| Resolution | 0.01 mm/h |
| Sampling Interval | 1 s to 60 min (user-configurable) |
| Operating Temperature | −40 °C to +85 °C |
| Storage Temperature | −40 °C to +85 °C |
| Relative Humidity | 0–100% RH |
| Ingress Protection | IP66 / NEMA 4X |
| Power Supply (sensor) | 10.5–15 VDC, <5 mW |
| Heater Option | 24 VDC, 1.05 A, 25 W |
| Timekeeping Accuracy | ±4 min/year (±7.6 ppm) |
| Output Interfaces | SDI-12 v1.3, RS-232/RS-422/RS-485 (half-duplex), mechanical pulse (reed switch) |
| Collection Area | Standard 200 cm² (optional 400 cm²) |
| Housing Material | Anodized aluminum / stainless steel |
| Funnel Material | Polypropylene |
| Internal Components | Aluminum / ABS |
| Dimensions | 300 mm H × 185 mm Ø |
| Weight | 1.5 kg |
| Compliance | CE, EMC, ESD, Safety, WMO Guide to Instruments and Methods of Observation (CIMO Guide) |
| Brand | Geonica |
|---|---|
| Origin | Spain |
| Model | 6115 |
| Type | Pulsed Radar Water Level Sensor |
| Frequency | 26 GHz |
| Measurement Range | 0–15 m (programmable) |
| Resolution | 1 mm |
| Accuracy | ±2 mm (full scale), ±1 mm (averaged with METEODATA/HYDRODATA-2000C/3000C loggers) |
| Output | 4–20 mA, SDI-12 |
| IP Rating | IP68 |
| Supply Voltage | 9.6–36 VDC |
| Current Consumption | <15 mA |
| Operating Temperature | −40 to +80 °C |
| Storage Temperature | −40 to +80 °C |
| Humidity | 0–100 % RH |
| EMC Compliance | EN 61326-1:2013 (Class B emission, Industrial immunity) |
| LVD Compliance | EN 61010-1:2010 |
| R&TTE Compliance | EN 302 729-1/2 V1.1.2 (2011-05) |