Packaging Industry Specialized Instruments
Filter
Showing 1081–1110 of 1185 results
| Brand | SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | STCB015 |
| Pressure Range | 1.0 / 1.5 / 2.0 / 3.0 MPa |
| Timing Range | 0–999.9 s (user-configurable) |
| Supply Air Pressure | 0.4–0.8 MPa (clean, dry air) |
| Pressure Resolution | 0.1 kPa / 1 kPa / 0.0001 MPa |
| Accuracy | ±0.2 % FS |
| Units | kPa, bar, psi, MPa |
| Pressure Regulation | Mechanical or Electromechanical (optional) |
| Data Export | USB |
| Communication Interfaces | RS232 / RS485 (selectable), RJ45 Ethernet |
| I/O Ports | 6 inputs, 6 outputs |
| Touchscreen | 7-inch LCD |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Operating Environment | 5–45 °C, ≤80 % RH (non-condensing) |
| Weight | 9.8–11 kg |
| Dimensions | 450 × 270 × 190 mm |
| IoT Capability | Yes |
| Barcode Scanning & MES Integration | Yes |
| Multi-channel Configuration | Optional |
| Brand | SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Auto Dental Irrigator Tester |
| Pressure Range | 0–500 g (0.1 g resolution) |
| Sound Pressure Level Range | 30–120 dB(A) (0.1 dB resolution) |
| Pressure Units | kPa, bar, psi |
| Air Supply Requirement | 0.4–0.8 MPa (clean, dry compressed air) |
| Power Input | AC 110–240 V, 50/60 Hz |
| Operating Environment | 5–45 °C, ≤80% RH (non-condensing) |
| Dimensions | 900 × 600 × 1230 mm |
| Weight | 200 kg |
| Display | 7-inch LCD touchscreen |
| Data Storage | Internal test result logging |
| Communication Interfaces | RS-232 / RS-485 (optional), RJ45 Ethernet |
| Data Export | USB flash drive |
| Test Channel | 1 channel (multi-channel expansion supported) |
| Pass/Fail Logic | Configurable pass/fail criteria with audible and visual alerts |
| Brand | SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Negative-Pressure Air-Tightness Tester |
| Quotation | Available Upon Request |
| Test Pressure Range | –70 kPa |
| Key | Brand: SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Floor-Standing Integrated Fixture System |
| Price Range | USD 4,200 – 7,000 |
| Application | IP68 Waterproof Integrity Testing for Smartphone Frames |
| Test Method | Dual-Station Direct-Pressure Air-Tightness Measurement |
| Test Pressure | 22 kPa |
| Custom Integration | Host PC Interface, Barcode Scanner Support, MES Connectivity |
| Key | Origin: Liaoning, China |
|---|---|
| Manufacturer Type | Distributor |
| Country of Origin | China |
| Model | SYJ-80QY |
| Price | Upon Request |
| Motor Power | 1600 W |
| Voltage/Frequency | AC 220 V / 50 Hz |
| Spindle Speed Range | 0–650 rpm |
| Standard Core Diameters | Ø32 mm, Ø45 mm |
| Max. Sampling Depth | 50 mm |
| Max. Sample Stage Size | 300 × 300 mm |
| Dimensions (L×W×H) | 500 × 512 × 750 mm |
| Cooling System | Integrated water-cooled feed |
| Operating Environment | ≤1000 m altitude, 10–40 °C ambient, 45–65 %RH |
| Water Supply | Required (inlet & drain) |
| Electrical Supply | AC 220 V / 50 Hz |
| Ventilation | Required |
| Footprint Requirement | 700 × 700 × 700 mm |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7101 |
| Pricing | Available Upon Request |
| Measurement Range | 0.002–70 g/(m²·d) (unmasked) |
| Temperature Control Range | 10–40 °C (50–104 °F) |
| Relative Humidity Control Range | 20–90 % RH |
| Sample Area | 50 cm² (adapters available for smaller specimens) |
| Sensor Technology | High-sensitivity Coulometric P₂O₅ sensor |
| Compliance | ASTM F3299–18 |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Model | 8101e |
| Test Gas | O₂ |
| RH Control Range | 0–90% ±2% |
| Temperature Control Range | 10–40°C ±0.1°C |
| Sensor Type | eMetric™ Coulometric Sensor |
| Sample Types | Flexible Films & Rigid Packaging |
| Maximum Configurable Stations | 32 |
| Operating System | Windows®-based Platform |
| Sealing Method | Q-Seal™ Chamberless Seal |
| Compliance | ASTM F2622, ASTM D3985, ISO 15105-2, ISO 1186 |
| Brand | Systech |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AquaSense Model 7100 |
| Pricing | Upon Request |
| Measurement Range (unmasked) | 0.002–70 g/m²/day |
| Measurement Range (masked) | 0.02–1000 g/m²/day |
| Temperature Range | 10–40 °C |
| Relative Humidity Range | 20–90 %RH |
| Sample Area | 50 cm² |
| Compliance | ASTM F3299-18, ISO 15105-2, ISO 15106-3, DIN 53122-2, GB/T 21529, YBB 00092003-2015 |
| Key Feature | Coulometric Sensor, TCM™ Test Condition Matrix, Q-Seal™ Sample Loading, Expandable to 32 Test Stations |
| Brand | Systech Illinois |
|---|---|
| Origin | United Kingdom |
| Model | Lyssy L80-6000 |
| WVTR Range | 0.03 – 10,000 g/m²/day (standard) |
| Test Temperature Range | 5 – 50°C |
| Relative Humidity Control Range | 5 – 60% RH |
| Ambient Humidity Tolerance | 10 – 90% RH (non-condensing) |
| Dimensions | 400 × 400 × 350 mm |
| Weight | 24 kg |
| Software | Permetrace™ |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | DIT-ASTM D1709 |
| Test Methods | ASTM D1709 (Method A & B), GB/T 9639, JIS K7124 |
| Mass Range | Method A: 50–2000 g |
| Method B | 300–2000 g |
| Resolution | 0.1 g (0.1 J) |
| Sample Clamping | Pneumatic, ≤1.1 MPa air supply required |
| Sample Size | >150 mm × 150 mm |
| Dimensions (A/B) | 450×450×1365 mm / 450×450×2160 mm |
| Power | AC 220 V, 50 Hz |
| Weight | 70 kg |
| Interface | Standard RS232/USB |
| Data Analysis | Built-in min/max/mean/SD calculation |
| Optional | Ball Impact Module, DSM Lab Data Management System, Safety Guard Kit |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | GB 8809-1988 Pendulum Impact Tester |
| Impact Energy Options | 1 J, 2 J, 3 J, 5 J (selectable) |
| Resolution | 0.001 J |
| Impact Head Diameter | Ø25.4 mm, Ø19 mm, Ø12.7 mm |
| Clamp Aperture | Ø89 mm, Ø60 mm |
| Specimen Size | 100 mm × 100 mm or Ø100 mm |
| Pneumatic Pressure Range | 0.3–1.5 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 492 × 383 × 752 mm |
| Net Weight | 44 kg |
| Compliance | GB/T 8809–1988, ASTM D3420, NF T54-116 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GTR-7004 |
| Price Range | USD 14,000–21,500 |
| Test Range | 15–15,000 s/100 mL (standard) |
| Resolution | 0.1 s/100 mL |
| Sample Count | 1 |
| Pressure Range | 20 kPa |
| Pressure Accuracy | ±0.01 kPa |
| Test Area | 1.0 in² (0.25 in² / 0.1 in² optional) |
| Max Sample Thickness | ≤5 mm |
| Test Gas | Clean compressed air (user-supplied) |
| Air Supply Pressure | 0.3–1.0 MPa |
| Interface | Ø6 mm pneumatic fitting |
| Dimensions | 320 × 380 × 410 mm (L×D×H) |
| Power | AC 220 V, 50 Hz |
| Net Weight | 25 kg |
| Compliance | ISO 5636-5, ASTM D726, TAPPI T460, GB/T 36363–2018 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYSTESTER GTR-1 |
| Price Range | USD 14,000 – 28,000 |
| Test Principle | Vacuum Pressure-Difference Method |
| Test Chamber | Single-cell |
| Temperature Control | Circulating medium thermostatic control (5 °C to 95 °C, optional) |
| Temperature Accuracy | ±0.1 °C |
| Vacuum Resolution | 0.1 Pa |
| Permeation Range | 0.01–170,000 cm³/m²·24h·0.1MPa |
| Resolution | 0.001 cm³/m²·24h·0.1MPa |
| Sample Thickness Limit | ≤3 mm |
| Effective Test Area | 48 cm² |
| Sample Dimensions | ≥150 mm × 94 mm or circular |
| Test Gases | O₂, N₂, CO₂, air, He (user-supplied gas source, 0.3–1.0 MPa) |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 28 kg |
| Dimensions (L×D×H) | 330 × 600 × 330 mm |
| Compliance Standards | GB/T 1038–2000, ISO 15105-1, ISO 2556, ASTM D1434, JIS K 7126-1, YBB 00082003 |
| Software Features | Audit trail, system logging, 5-level user permission management, DSM LIMS integration (optional) |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Jinan SYSTESTER Heat Sealing Tester |
| Price Range | USD 4,200 – 7,000 |
| Touchscreen Interface | Industrial TFT LCD |
| UI Design | Zero-navigation-depth flat interface |
| Temperature Control | Dual independent sealing bars |
| Max Operating Temperature | 300 °C |
| Temp Range | RT + 6 °C to 300 °C |
| Temp Accuracy | ±0.2 °C |
| Sealing Time | 0.1–999.9 s |
| Sealing Pressure | 0.05–1.1 MPa |
| Sealing Area | 265 mm × 12 mm (customizable) |
| Sealing Mode | Dual-bar independent control |
| Pneumatic Interface | Ø6 mm |
| Air Supply Requirement | 0.05–1.1 MPa (user-supplied) |
| Dimensions (L×W×H) | 410 × 396 × 416 mm |
| Weight | 33 kg |
| Power | AC 220 V, 50 Hz |
| Safety Features | Emergency stop button, anti-scald housing, fanless design |
| Noise Level | <35 dB(A) |
| Standard Compliance | QB/T 2358 (equivalent to ZBY 28004), ASTM F2029, YBB00212005-2015 |
| Data Output | Integrated thermal printer |
| Communication Interface | Standard RS232/USB |
| Optional Integration | DSM Laboratory Data Management System (sold separately) |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | Membrane Separation Performance Evaluation System |
| Test Range | 0.01–2×10⁴ Barrer |
| Gas Flow Rate | 0–100 mL/min (200/300 mL/min optional) |
| Measurement Accuracy | ±0.01 Barrer |
| Vacuum Accuracy | ±0.1 Pa |
| Test Pressure Differential | 0–10 bar (system rated to 16 bar) |
| Temperature Control Range | 5–95 °C (±0.1 °C with optional chiller/heater) |
| Effective Test Area | Φ20 mm (3.14 cm²) |
| Sample Thickness Limit | ≤2 mm |
| Sample Capacity | 1 specimen per run |
| Detector Sensitivity | ≥5000 or 10000 mV·mL/mg (configurable) |
| Baseline Drift | ≤0.10 mV |
| Noise | ≤0.015 mV |
| Carrier Gas Pressure | 2 bar |
| Compatible Carrier Gases | N₂, H₂, He, Ar |
| Dimensions (Host) | 320 × 625 × 335 mm (W×D×H) |
| (GC Unit) | 590 × 480 × 500 mm (L×W×H) |
| Power Supply | AC 220 V, 50 Hz |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | OX2/231 |
| Price Range | USD 28,000 – 42,500 |
| Measurement Principle | Coulometric Sensor (ISO 15105-2 Compliant) |
| Test Method | Isobaric Equal-Pressure Mode |
| Chambers | 3 Independent Testing Cells |
| Temperature Control Range | 5–95 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control | 0%RH, 35–90%RH (±1%RH accuracy) |
| Film OTR Range | 0.01–6500 cm³/m²·d (standard), up to 63,000 cm³/m²·d (optional) |
| Container OTR Range | 0.0001–62 cm³/pkg·d |
| Film Resolution | 0.001 cm³/m²·d |
| Container Resolution | 0.00001 cm³/pkg·d |
| Test Area | 48 cm² |
| Sample Size (Film) | ≥150 mm × 94 mm or circular |
| Sample Size (Container) | ≤Φ120 mm × 400 mm (H) |
| Max. Thickness | 3 mm |
| Carrier Gas | 99.999% High-Purity N₂ |
| Flow Rate | 0–200 mL/min |
| Interface | 1/8″ Stainless Steel Tubing |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 730 × 590 × 350 mm |
| Net Weight | 56 kg |
| Standards Compliance | GB/T 19789, ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, ISO 15105-2, JIS K7126-B, YBB 00082003 |
| Software | Embedded Win-based Control & Analysis Suite with Audit Trail, Multi-level User Access (5 tiers), Real-time Curve Logging (T, RH, Flow, OTR), Optional DSM Laboratory Data Management System Integration |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QBT 2411 |
| Price Range | USD 18,000 – 24,500 |
| Test Principle | Gravimetric Cup Method |
| Test Range | 0.001–220 µg/(m²·s) |
| Permeability Range | 1×10⁻³–40,000 ng/(m²·s·Pa) |
| Sample Capacity | 6 independent stations |
| Weight Resolution | 0.0001 g |
| WVTR Resolution | 0.00001 µg/(m²·s) |
| Temperature Range | 15–55 °C (±0.1 °C control accuracy) |
| Humidity Range | 10–95 %RH (±1 %RH control accuracy |
| Air Sweep Velocity | 0.5–2.5 m/s |
| Specimen Thickness Limit | ≤25 mm |
| Test Area | 33.17 cm² |
| Specimen Diameter | Φ81 mm |
| Chamber Volume | 36 L |
| Air Supply | Compressed air, 0.2–1.0 MPa, Φ8 quick-connect fitting |
| Power | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 650 × 550 × 475 mm |
| Net Weight | 67 kg |
| Compliance | GB/T 1037, QB/T 2411–1998 |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | TSL-1002 |
| Load Capacity Options | 50 N, 100 N, 250 N, 500 N, 1000 N, 2000 N |
| Test Speed Range | 0.1–1000 mm/min (software-controlled, infinitely variable) |
| Stroke | 1000 mm |
| Displacement Resolution | 0.01 mm |
| Clamp Width (standard) | 30 mm |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 300 W |
| Dimensions (L×W×H) | 380 × 450 × 1309 mm |
| Net Weight | 92 kg |
| Accuracy Class | Better than Grade 0.5 |
| Compliance Standards | GB/T 3923.1–2013, GB/T 17200, ISO 37, ASTM D882, ASTM D1938, ASTM F88, EN ISO 11600, JIS P8113 |
| Brand | T/A |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FP-2260 |
| Price Range | USD 14,000 – 70,000 |
| Standards Compliance | ASTM D1894, D4521, D3330, F88 |
| Load Cell Options | 0.5 kg, 1 kg, 2 kg, 10 kg |
| Resolution | 0.1 g |
| Accuracy | ±0.25% of full scale |
| Force Units | g, kg, oz, lb, N |
| Test Speed | Standard: 1–20 in/min |
| High-Speed | 10–110 in/min |
| Standard Sled Masses | 200 g, 500 g, 1000 g, 3 lb |
| Test Duration | 0.1–99 s |
| Travel Distance | 0.1–14.0 in |
| Display | 240 × 64 pixel LCD |
| Data Storage | 127 test records |
| Test Area | 225 mm × 350 mm |
| Power Supply | 220 V, 50 Hz |
| Dimensions (L×W×H) | 27 in × 12 in × 7 in |
| Weight | 20 kg |
| Brand | Taber |
|---|---|
| Origin | USA |
| Model | 150-E |
| Measurement Range | 0–10,000 Taber Stiffness Units (g·cm) |
| Compliance | CE Marked |
| Power Supply | 115/230 VAC, 50/60 Hz |
| Display | 4×20 Vacuum Fluorescent Display |
| Data Storage | 1,000 readings with timestamp & user-defined labels |
| Interface | RS-232 serial port, parallel printer port |
| Test parameters programmable | deflection angle, direction, cycle count |
| Accuracy | ±1% full scale (factory calibrated) |
| Sample thickness range | 0.1–5.5 mm |
| Brand | Taber |
|---|---|
| Origin | USA |
| Model | 150-E |
| Sample Thickness Range | 0.1–5.5 mm |
| Applicable Materials | Paper, Foil, Thin Metal Sheets, Plastic Films, Cardboard, Rubber, Melamine Board, Vinyl, Wires, Tubing, Textiles, Felt, Leather |
| Drive Mechanism | Constant-Speed Motor with Gear-Driven Rotating Disc |
| Measurement Principle | Pendulum Deflection Under Controlled Torsional Load |
| Output | Analog Dial or Digital Display (Configurable) |
| Brand | Taber |
|---|---|
| Origin | USA |
| Model | Taber 1750 |
| Compliance | ASTM D3884, ASTM D4060, ISO 9352, ISO 5470-1, JIS K7204, TAPPI T476, DIN 52347, EN 13329 |
| Operating Environment | 21–24°C (70–75°F), 50% RH |
| Sample Mounting | Flat, rigid specimens secured on rotating turntable |
| Abrasion Mechanism | Dual counter-rotating abrasive wheels applying controlled load in crossed-arc motion |
| Vacuum-Assisted Debris Removal | Adjustable suction for real-time particulate extraction |
| Control Interface | Digital display with programmable cycle count, vacuum activation, and power-on resume memory |
| Brand | Taber |
|---|---|
| Origin | USA |
| Model | 5135 |
| Power Supply | 115 V, 50/60 Hz AC |
| Compliance | ASTM D3884, ASTM D4060, ISO 9352, ISO 5470-1, JIS K7204, TAPPI T476 |
| Sample Area | 30 cm² |
| Load Range | Adjustable in grams (g) |
| Rotation Count | Electronically measured |
| Vacuum Dust Extraction | Integrated |
| Brand | Taber |
|---|---|
| Origin | USA |
| Model | Taber 551 |
| Sample Thickness Capacity | 0.5" to 4" (12.7 mm to 101.6 mm) |
| Adjustable Normal Load Range | 0–1000 g |
| Standard Compliant | ASTM D7027, ISO 4586-2, EN 438-2, JIS K6902, DIN 53799, AS/NZS 2924.2, CEN/TS 14688, UNI 9428, Federal Specifications L-F-00450A, L-T-00345, L-T-751, SS-T-307, SS-T-312 |
| Brand | Taber |
|---|---|
| Origin | USA |
| Model | CS-8 |
| Type | Elastic Bond Calibrase™ Abrasive Wheel |
| Diameter | 6.35 mm (1/4″) |
| Thickness | Standard |
| Bond Matrix | Elastomeric |
| Abrasive Material | Silicon Carbide |
| Design Purpose | Controlled wear surface regeneration via binder decomposition during testing |
| Recommended Load Range | Light-duty (≤500 g) |
| Pre-test Conditioning | Surface renewal with S-14 abrasive paper |
| Shelf Life | Printed on packaging |
| Compliance | Designed for ASTM D4060, ISO 5470-1, TAPPI T476, and GB/T 23988 |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | FC501 Series |
| Pricing | Upon Request |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HTY-BWS02 |
| Power | 30 W |
| Dimensions (L×W×H) | 22.0 × 20.0 × 14.0 cm |
| Weight | 3.0 kg |
| Battery Capacity | 5600 mAh |
| Sampling Method | Negative-Pressure Vacuum Filtration with Air-Equalization Venting |
| Sample Pathway | Fully Enclosed Tubing |
| Packaging Interface | Patented Sterile Piercing Port |
| Operation Mode | Programmable Timer-Based Volume Control |
| IP Rating | IPX4 (Splash-Resistant) |
| Power Source | Rechargeable Lithium-Ion Battery (Internal) |
| Brand | PW (Yuelian) |
|---|---|
| Origin | Guangdong, China |
| Model | YLCK-25 |
| Sample Width | 25 mm (customizable) |
| Sample Length | 210 mm |
| Sample Thickness Capacity | ≤300 µm |
| Cutting Capacity | 10 specimens per stroke (single-layer) |
| Dimensions | 420 × 310 × 250 mm |
| Weight | 14.8 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thwing-Albert |
| Price Range | USD $13,500 – $67,500 (FOB) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FP-260 |
| Price Range | USD 13,500 – 68,000 |