Petroleum Specialized Analytical Instruments
Filter
Showing 661–690 of 1348 results
| Brand | OFITE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 810-00-1 |
| Pricing | Upon Request |
| Pressure Source | CO₂ |
| Sample Chamber Dimensions | 7.8 cm ID × 27.6 cm L |
| Sample Volume Capacity | 1000 mL |
| Screen Diameter | 50 mm |
| Overall Dimensions | 29 × 20 × 69 cm |
| Weight | 10.9 kg |
| Brand | OFITE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 175-60 / 175-60-6 |
| Price | Upon Request |
| Brand | atten2 |
|---|---|
| Origin | Spain |
| Model | OilCMS |
| Instrument Type | Online Lubricant Condition Monitor |
| Detection Parameters | Particle Contamination, Water Content (RH%), Oil Degradation State, Viscosity Estimation (up to 3000 cSt) |
| Compliance Standards | ISO 4406, SAE AS4059, NAS 1638 |
| Display | 10-inch capacitive touchscreen |
| Power | Integrated rechargeable lithium battery |
| Data Storage | Local database for up to 500 oil samples with trend aggregation |
| Flow Control | Built-in motorized pump with optional high-pressure adapter (compatible with real-time recirculation systems up to 350 bar) |
| Particle Analysis Method | Digital imaging with bubble suppression and morphological classification |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 500 |
| Price | Upon Request |
| Standards Compliance | ASTM D36, ASTM E28, EN 1427, IP 58, ISO 4625, DIN 52011, NF T 66-008, AASHTO T53, JIS K2207 |
| Temperature Range | 0–250 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | OilMoisture |
| Product Type | Online Instrument |
| Detection Parameter | Water Content |
| Compliance Standard | ASTM D6304 |
| Sensitivity | ppm-level |
| Power Supply | 24 V DC, <100 mA |
| Output Interface | Modbus RTU (RS-485) |
| Max Operating Pressure | 12 bar |
| Operating Temperature Range | 0–80 °C |
| Viscosity Compatibility | up to 680 cSt |
| Housing Material | Aluminum (stainless steel optional) |
| Optical Window | BK7 glass |
| Sealing Material | Fluoroelastomer (FKM) |
| Ingress Protection | IP65 |
| Certification | CE |
| Brand | Optimol |
|---|---|
| Origin | Germany |
| Model | 2Disk |
| Drive Speed Range | 1–3000 rpm |
| Applied Load Range | 10–5000 N |
| Maximum Test Duration | 999 h |
| Cooling | Optional Water-Cooled Drive Spindle |
| Temperature Monitoring | Integrated Spindle & Lubricant Temperature Sensors |
| Optional Measurements | Lubricant Film Thickness (Oil Gap), Electrical Resistance, Acoustic Emission (Noise), Wear Volume Quantification |
| Environmental Control Options | Heated Oil Bath, External Oil Circulation Pump |
| Software | Customizable LabVIEW- or Python-Based Control & Data Acquisition Suite |
| Brand | Optimol |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ETS |
| Price | Upon Request |
| Brand | ORBIS BV |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CFPP |
| Price Range | USD 13,500 – 67,500 (FOB Rotterdam) |
| Test Range | −105 °C to +65 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Sensor | PT100 Class A |
| Temperature Resolution | 0.1 °C |
| Vacuum Control | Microprocessor-controlled, programmable fixed/dynamic vacuum (2.0 ± 0.1 kPa) |
| Cooling System | Integrated solid-state thermoelectric bath (no external chiller required), min. temp. −105 °C |
| Cooling Profile | Programmable linear and stepwise ramping |
| Sample Detection | Triple-point laser level sensor |
| Filtration Mesh | 45 µm stainless steel |
| Pipette Volume | 20 mL |
| Timing Resolution | >0.1 s (digital display) |
| Data Storage Capacity | 200 test records |
| Cleaning Protocol | Fully automated dual-solvent wash cycle |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Power Consumption | 150 W |
| Dimensions (W×D×H) | 16 cm × 59 cm × 35 cm |
| Weight | 25 kg |
| Brand | ORBIS BV |
|---|---|
| Origin | Netherlands |
| Model | CPPP |
| Temperature Bath Range | +65 °C to −105 °C |
| Cooling Rate | 1–60 °C/h (linear or stepwise) |
| Detection Method | High-resolution digital imaging with real-time video analysis |
| Temperature Sensor | Removable Pt100 probe with embedded calibration data and ID |
| Power Supply to Test Head | Wireless Powercast® technology |
| Motion Control | Microprocessor-driven stepper motor for precise tube lifting and tilting |
| Compliance | ASTM D97, D2500, D5853, D5771, D6892 |
| Brand | ORBIS BV |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | STARDist |
| Operating Pressure | Atmospheric |
| Temperature Range | Ambient to 450 °C |
| Temperature Accuracy | ±0.1 °C |
| Condenser Temperature Range | 0–65 °C |
| Recovery Chamber Temperature Range | 0–45 °C |
| Distillation Rate | 2–11 mL/min |
| Volume Detection Range | 0–105% (v/v) |
| Volume Resolution | 0.01 mL |
| Volume Accuracy | ±0.01 mL |
| Residue Measurement | Automatic or Manual |
| Barometric Range | 70–110 kPa (0.1 kPa resolution) |
| Safety System | Integrated Flame Detection with Nitrogen-Actuated Extinguishing |
| Data Interface | Ethernet (LIMS-compatible) |
| Dimensions | 40 × 40 × 63 cm |
| Weight | 40 kg |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Power Consumption | 1.2 kW |
| Brand | Orienda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | SARAlyzer Elite |
| Pricing | Available Upon Request |
| Brand | FORZA |
|---|---|
| Origin | USA |
| Model | Oxi Plus |
| Temperature Range | 40–150 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Capacity | 4–30 test tubes (method-dependent) |
| Safety Features | Over-temperature cutoff switch, low-level liquid protection switch |
| Flow Monitoring | Glass rotameter included |
| Import Status | Imported |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Model | ABS |
| Power Supply | 100–230 V AC, 750 VA |
| Operating Temperature | 15–35 °C |
| Operating Humidity | 20–80 % RH (non-condensing) |
| Weight | 34 kg |
| Dimensions | Not specified |
| Compressed Air Requirement | ASTM D5001-compliant (≤0.1 ppm hydrocarbons), dry and oil-free |
| Deionized Water Reservoir Capacity | ~1000 tests per fill |
| Control | Microprocessor-based, fully automated |
| Environmental Compliance | Designed for ISO/IEC 17025-aligned laboratories |
| Software Interface | PC-based control and data logging with audit-trail capability |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | EHD2 |
| Pricing | Upon Request |
| Product Type | Laboratory Instrument |
| Test Parameters | Oil Film Thickness (1–1000 nm), Traction Coefficient (Friction Coefficient) |
| Load Range | 0–50 N |
| Contact Pressure Range | 0–0.7 GPa (Steel Ball–Glass Disk) / 0–3 GPa (WC Ball–Sapphire Disk) |
| Sliding/Rolling Ratio | 0–100% |
| Linear Speed | 0–4 m/s |
| Temperature Range | Ambient to 150 °C |
| Sample Volume | 120 mL |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Model | HFRR |
| Frequency Range | 10–200 Hz |
| Stroke Range | 20 µm–2.0 mm |
| Load Capacity | 0–1.0 kg (via calibrated weights) |
| Maximum Friction Force | up to 10.0 N (amplitude-dependent) |
| Operating Temperature | ambient to 150 °C (up to 400 °C with optional high-power heating module) |
| Standard Counterface | 10.0 mm diameter × 3.0 mm thick steel disc |
| Standard Indenter | 6.0 mm diameter hardened steel ball |
| Compliance | ASTM D6079, ASTM D7688, ISO 12156-1, SH/T 0765–2021 |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ETM |
| Product Type | Laboratory Instrument |
| Test Parameter | Friction and Wear |
| Load Range | 100–1650 N |
| Maximum Contact Pressure | 3.5 GPa (standard steel test specimens) |
| Sliding Velocity | up to 3.5 m/s |
| Temperature Range | 10–150 °C |
| Sample Volume | 30 mL (10 mL with optional filler insert) |
| Operating System | Windows 10 |
| Safety Features | Dual PT100 RTD temperature monitoring, emergency stop button, interlocked lubricant reservoir lid |
| Power Supply | 100–240 V, 50/60 Hz, 1600 VA |
| Weight (main unit) | 52 kg |
| Dimensions (H × W × D) | 425 mm × 400 mm × 605 mm |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MPR |
| Product Type | Laboratory Instrument |
| Test Parameter | Friction and Wear |
| Load Range | 0–2000 N |
| Contact Pressure | 0–3.2 GPa |
| Sliding/Rolling Ratio | 0–200% |
| Temperature Range | Ambient to 150 °C |
| Specimen Volume | 150 mL |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Import Status | Imported |
| Model | MTM2 |
| Product Type | Laboratory Instrument |
| Test Parameter | Friction and Wear |
| Sample Volume | 10–35 mL |
| Load Range | 0–75 N |
| Contact Pressure Range | 0–1.25 GPa (standard test geometry) |
| Sliding/Rolling Velocity | −4 to +4 m·s⁻¹ |
| Temperature Range | Ambient to 150 °C (sub-ambient operation supported via external refrigerated oil bath) |
| Power Supply | 100–240 V AC, 50/60 Hz, 750 VA |
| Host Weight | 30 kg |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 600-SA |
| Pricing | Available Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP651 |
| Price | Upon Request |
| Temperature Range | Ambient to 100 °C |
| Temperature Accuracy | ±2 °C |
| Temperature Repeatability | ≤4 °C |
| Temperature Resolution | 0.1 °C |
| Stirring Duration | 5 min (fixed) |
| Stirring Depth | 6 mm above cylinder bottom |
| Cylinder Capacity | 100 mL |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤1600 W |
| Dimensions (W×D×H) | 510 mm × 360 mm × 580 mm |
| Net Weight | 23.5 kg |
| Operating Environment | 5–40 °C, RH ≤85% |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PGC5007B |
| Pricing | Available Upon Request |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | BOCLE D5001 |
| Standard Compliance | ASTM D5001 |
| Test Duration | 30 min |
| Load | Fixed Ball Load (Standardized per ASTM D5001) |
| Sample Volume | 50 mL |
| Temperature Control | Precision Thermostatic Bath |
| Humidity & Airflow Control | Integrated Environmental Regulation System |
| Measurement Method | Optical Microscopy of Wear Scar Dimensions (Major & Minor Axes) |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | PD 100CC |
| Compliance | ASTM D2892, ASTM D5236 |
| Control System | Windows-based PC software with real-time process visualization |
| Vacuum Control | Auto-adjusted residual pressure (100, 50, 10, 2 Torr) with manual override |
| Safety Features | Overtemperature shutdown, nitrogen purge activation, audible/visual alarms |
| Fraction Collection | 20-position airtight fraction collector with automated cooling, weighing, logging, and cleaning |
| Interface | Ground-glass joints with elastomeric seals — grease-free vacuum integrity |
| Distillation Modes | Integrated atmospheric-to-vacuum transition with automatic gap cooling |
| Data Output | Excel-native reporting, TBP curve generation, AET temperature conversion |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | PD 104 / PD 107 |
| Construction | Full Borosilicate Glass (Duran®-grade) |
| Distillation Mode | Batch, Vacuum-to-Atmospheric |
| Theoretical Plates | Up to 90 |
| Minimum Sample Volume | 1 mL |
| Column Type | Concentric-Tube Precision Fractionating Column |
| Vessel Options | 0.05–20 L (Glass or SS) |
| Heating Options | Oil Bath or Electric Heating Mantle |
| Compliance | ASTM D2892, D5236, ISO 9198, IP 123 |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | PD 105 |
| Application Domain | Petroleum & Petrochemical R&D, Fine Chemical Synthesis, High-Purity Separation |
| Operating Pressure Range | Atmospheric to Vacuum (≤ 0.1 mbar) |
| Temperature Control Method | Programmable Oil Bath with PID Regulation |
| Reflux Ratio Control | Adjustable via Motorized Reflux Divider |
| Fraction Collection Modes | Temperature-Triggered, Volume-Triggered, or Time-Triggered |
| Receiver Options | 6-, 9-, or 18-position Automated Fraction Collector with Overflow Protection |
| Software Platform | Windows-Based Control Suite with Real-Time Parameter Logging and Curve Visualization |
| Compliance Framework | Designed to Support ASTM D2892 (True Boiling Point Distillation), ASTM D5236 (Extended True Boiling Point), and ISO 3405 |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | PD 200CC |
| Standard Compliance | ASTM D5236 |
| Control System | Windows-based PC-controlled automation |
| Collection Capacity | 12 fraction receivers with IR heating and level tracking |
| Safety Features | Overtemperature shutdown, nitrogen purge activation, user-definable alarm thresholds |
| Distillation Mode | Vacuum batch distillation with automatic AET conversion and cut-point assignment |
| Material Construction | High-purity borosilicate glass (DIN/ISO 3585), ground-glass joints with elastomeric seals (no vacuum grease required) |
| Thermal Management | Adaptive heating power modulation and dynamic coolant temperature control |
| Data Output | Native Excel export (.xlsx), real-time curve visualization (volume % vs. AET °C), GLP-compliant audit trail |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | PD 400CC |
| Standards Compliance | ASTM D2892 & ASTM D5236 |
| Distillation Capacity | 6 L (standard), optional 2–20 L |
| Max Operating Temperature | 420 °C (AET) |
| Pressure Range | 1–760 mmHg |
| Control System | Windows-based PC automation with real-time monitoring and safety interlocks |
| Safety Features | Overtemperature shutdown, vacuum overpressure protection, power-fail emergency cooling, level/leak detection, automatic condenser and pot cooldown |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | PD1120CC |
| Standard Compliance | ASTM D1120, SAE J1704 |
| Automation Level | Fully Automated |
| Test Duration | 8–15 min per sample |
| Output | Permanent thermal print + network-enabled PDF export |
| Regulatory Context | Designed for GLP-compliant laboratories |
| Application Scope | Engine coolant and brake fluid equilibrium boiling point (EBP) determination |
| Brand | PILODIST |
|---|---|
| Origin | Germany |
| Model | PD300CC |
| Max. Distillation Temperature | 400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | 0–25 °C |
| Distillation Rate | 180–360 mL/h |
| Volume Detection Range | 1–200 mL |
| Volume Resolution | 0.1 mL |
| Compliance | ASTM D1160 |
| Control Interface | 15.6″ IP65-rated touchscreen with integrated thermal printer |
| Data Export Formats | PDF, XLS, CSV, TXT |
| Safety | Dual independent heating safety circuits, auto-termination on AET limit, bath temperature limit, flask temperature limit, distillate volume limit, pressure drop, or flask fracture detection |
| Optional Accessory | 4-position automated fraction collector |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | QUICKDIST 500 CC, QUICKDIST 500M |
| Operating Temperature (Flask) | Up to 350°C |
| Final Boiling Point (AET) | Up to 420°C |
| Operating Pressure | Atmospheric to <1 mbar (vacuum) |
| Theoretical Plates | Up to 60 |
| Flask Volumes | 100 mL, 500 mL, 1 L, 2 L |
| Feed Capacity | Up to 60% of flask volume |