| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | 225 / D2068 |
| Compliance | ASTM D2068, IP 387 |
| Operating Temperature Range (Bath) | −10 °C to +40 °C |
| Sample Temperature Range | −50 °C to +80 °C |
| Flow Rate | 20 mL/min |
| Pressure Measurement Range | 0–210 kPa |
| Max. Pressure Threshold | 105 kPa |
| Filtration Capacity Resolution | 0.1 mL |
| Temperature Sensor | PT100 Class A |
| Bath Material | Anodized Aluminum |
| Cooling System | Single-phase air-cooled compressor, CFC-free refrigerant |
| Data Storage Capacity | 60,000 test records |
| Display | 6.4″ TFT/LCD touchscreen (640 × 480 pixels) |
| Processor | AMD Geode 800 |
| Interface | 1 × USB, 1 × 10/100 Mbps LAN |
| Safety Certification | CE |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | 300/410/2 |
| Standards Compliance | ASTM D1177, D97, D2386, D5901, D5972, D5853, D5950, IP16, IP441, IP528, IP529, ISO 3013, ISO 3016, GB/T 6537, SH/T 0770, GB/T 510 |
| Temperature Range | +80 °C to –80 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Cooling System | Dual-stage fluorine-free compressor, min. –85 °C |
| Temperature Sensor | Pt100 Class A |
| Optical Detection | Pulsed IR fiber-optic probe (freeze point) |
| Mechanical Detection | Dual PT100 surface probes + programmable tilt actuator (pour/pour point) |
| Power Supply | 220 V ±15%, 50/60 Hz |
| Dimensions (W×D×H) | 66 × 60 × 80 cm (1-head) |
| Weight | 70 kg (1-head, single-stage), 80 kg (1-head, dual-stage), 90 kg (2-head, single-stage), 100 kg (2-head, dual-stage) |
| Software | LabLink v5.x (Windows 2000/XP/Vista), supports up to 10 analysis heads, LIMS-compatible, 21 CFR Part 11-ready audit trail, Excel-exportable data format (.csv/.xls), >60,000 result storage capacity |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | 410 |
| Freeze Point Range | +80 °C to –100 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Compliance | ASTM D1177, D2386, D5901, D5972, D1655 |
| Measurement Principle | Coaxial pulsed IR spectroscopy with fiber-optic probe and reflective optical path |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | 560 |
| Power Consumption | 2300 W |
| Compliance | ASTM D381, IP 131, DIN 51784 |
| Heating Block | 8-position aluminum block with steam outlet |
| Temperature Range | Ambient to 300 °C (adjustable in 1 °C increments, stability ±0.5 °C) |
| Air Flow Control | 0–12 m³/h (high-precision mass flow meter) |
| Steam Pressure Control | 0–6 psi (stainless steel pressure gauge) |
| Heating System | Four 575 W heaters (total 2300 W) |
| Safety | Overheat protection, CE-certified, automatic standby mode |
| Interface | Touchscreen LCD with embedded control software |
| Construction | Ceramic-coated stainless steel housing with integrated steam generator and removable stainless steel steam tubing |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | 570SA |
| Standards Compliance | ASTM D2112, ASTM D2272, ASTM D4742, SH/T 0193 |
| Temperature Range | Ambient to 199 °C |
| Temperature Control Accuracy | ±0.1 °C (Pt100 sensor) |
| Bath Capacity | 30 L stainless steel oil bath |
| Configuration | Benchtop dual-bomb system with ceramic-coated stainless steel housing |
| Rotation Angle | 30° from horizontal |
| Oxygen Pressure | 620 kPa (90 psi) |
| Test Modes | RBOT and TFOUT |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | 580 |
| Standards Compliance | ASTM D5800, DIN 51581, CEC L-40-A-93 |
| Temperature Range | 0–320 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Air Flow Control | Adjustable differential pressure (20 mm H₂O / 1.96 mbar), valve- and flowmeter-regulated |
| Evaporation Duration | 60 min at set temperature |
| Safety Features | Overtemperature protection, integrated oil-filtered vacuum pump |
| Interface | RS-232 serial port for real-time temperature and pressure data logging |
| Display | LCD showing actual temperature, differential pressure, elapsed time |
| Automation | Auto-start test sequence, acoustic timer alert, fault indication via audible tone and visual LED status |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | 700 |
| Standard Compliance | ASTM D5191, ASTM D323, IP 394 |
| Measurement Principle | Vapor Pressure via Air-Saturation Method at 37.8 °C |
| Sample Volume | 3 mL |
| Test Chamber Volume | 15 mL |
| Chamber Temperature Control | 37.8 °C ± 0.1 °C (PT100, 1/10 DIN accuracy) |
| Sample Temperature Control | 0 °C (external chiller required) |
| Pressure Range | 0–10 bar absolute (0–145 psi) |
| Vacuum System | Integrated vacuum pump interface |
| Dimensions (W×D×H) | 30 × 70 × 60 cm |
| Weight | 27 kg |
| Power Supply | 230 V / 50 Hz |
| Ambient Operating Conditions | ≤35 °C, ≤80% RH |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | 226 (ASTM D4539 Compliant) |
| Cooling Range | +80 °C to −45 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.06 °C |
| Vacuum Control | Precisely regulated at 20 kPa |
| Sample Capacity | 6 × 300 mL positions |
| Cooling Rate | 1 °C/h |
| Pass Criterion | ≥180 mL filtrate collected within 60 s under vacuum |
| Temperature Sensor | PT100 Class A |
| Built-in Control System | AMD Geode800 CPU, 12″ TFT touchscreen (1024 × 768), 60,000-test storage capacity |
| Refrigerant | CFC-free compressor system |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | NewLab 100 / D2500 |
| Temperature Range | +80 °C to –80 °C |
| Cooling System | Single-stage or dual-stage compressor |
| Temperature Sensor | Pt100 Class A |
| Optical Detection | Pulsed IR fiber-optic probe with silver-coated sample tube bottom |
| Temp. Resolution | 0.06 °C |
| Temp. Accuracy | ±0.1 °C |
| Compliance | ASTM D2500, D5771, D5772, D5773 |
| Software | LabLink (Windows-compatible, multi-head control up to 10 units) |
| Data Storage | >60,000 assays, Excel-exportable, LIMS-integrated |
| Dimensions (1-head) | 66 × 60 × 80 cm |
| Weight (1-head, single-stage) | 70 kg |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | 1300 |
| Temperature Range | +80 °C to –80 °C |
| Cooling System | Single-stage or dual-stage compressor (–40 °C or –85 °C min) |
| Temperature Sensor | PT100 Class A |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Compliance | ASTM D2500, D5771–D5773, D97, D5950, D5853 |
| Optical Detection | Pulsed IR fiber-optic probe for cloud point |
| Mechanical Detection | Dual PT100 surface probes + motorized tilt arm for pour point |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | NewLab 300 |
| Temperature Range | +80 °C to –80 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Compliance | ASTM D97, D5950, D5853 |
| Detection Method | Dual PT100 surface probes with motorized sample tube tilting |
| Cooling System | Single-stage or dual-stage compressor options |
| Test Heads | 1 or 2 independent stations |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | NewLab 300/2 |
| Temperature Range | +80 °C to –80 °C |
| Cooling System | Dual-stage compressor |
| Temperature Sensor | PT100 Class A |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Standards Compliance | ASTM D97, D5950, D5853 |
| Sample Capacity | Dual PT100 surface probes, standardized test tube per ASTM/IP/ISO |
| Software | LabLink (Windows-compatible), supports up to 10 analysis heads, LIMS- and Excel-compatible data export, audit-trail-capable calibration logging |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | NewLab 410/2 |
| Cooling Capacity | −85 °C (dual-stage compressor) |
| Temperature Range | +80 °C to −100 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Compliance | ASTM D1177, D2386, D5901, D5972, D1655 |
| Detection Principle | Optical crystallization detection via coaxial IR fiber-optic probe and polished mirror surface |
| Temperature Sensor | PT100 Class A |
| Stirring System | Miniature motor-driven mechanical stirrer |
| Cooling System | Hermetic dual-stage refrigeration (R513A/R1234ze, fluorine-free) |
| Power Supply | 220 V ±15 %, 50/60 Hz |
| Safety Certifications | CE, integrated pressure controllers, thermal cut-offs, compressor overload protection |
| Software | LabLink v5.x (Windows 10/11 compatible), supports up to 10 analysis heads, 21 CFR Part 11–ready audit trail, LIMS integration, Excel-exportable data format (.csv, .xlsx) |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | TAG 690 |
| Compliance | ASTM D56, D3278, D3934, D3941 |
| Temperature Range | –50 °C to +100 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Probe | PT100 Class A |
| Sample Cup | Copper, with level mark and heat-resistant handle |
| Heating System | Electronic heater with overtemperature protection |
| Cooling System | Liquid refrigerant controlled by internal solenoid valve |
| Ignition Mechanism | Automatic mechanical ignition switch per standard protocol |
| Dimensions (W×D×H) | 48 cm × 37 cm × 61 cm |
| Weight | 32 kg |
| Power Supply | 220 V ±15%, 50/60 Hz |
| Operating Environment | ≤35 °C, ≤80% RH |
| Safety Certification | CE |
| Brand | Linetrionic |
|---|---|
| Origin | Switzerland |
| Model | OILLAB 611 |
| Measurement Range | –15 °C to +160 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Sensor | PT100 Class A |
| Detection Principle | Dual-channel photometric phase transition detection |
| Sample Compatibility | Transparent, turbid, and opaque (including black) hydrocarbon samples |
| Cooling System | Hybrid air-cooling (fan) + Peltier-based liquid cooling |
| Heating System | Immersion-type electronic heater with PID control |
| Stirring | Motor-driven magnetic stirrer with programmable speed profile |
| Display | 8-inch TFT/LCD touchscreen (1024 × 768, 16M color) |
| Onboard Storage | 49 GB SSD |
| Interfaces | 2 × USB 2.0 |
| Compliance | ASTM D611 (Methods A, B, E), IP 2 (Methods A, B, E), ISO 2977, GB/T 262–2010 |
| Brand | Linetroic |
|---|---|
| Origin | Switzerland |
| Model | 200 CFPP |
| Compliance | ASTM D97, D5950, D5853 |
| Temperature Range | +80 °C to –90 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Cooling System | Single-stage or dual-stage compressor (–40 °C or –85 °C base cooling) |
| Sensor Type | PT100 Class A platinum resistance thermometers |
| Sample Capacity | Standardized test jar per ASTM/IP/ISO specifications |
| Brand | Linetronic |
|---|---|
| Origin | Switzerland |
| Model | 615 |
| Temperature Control Range | 5–35 °C |
| Temperature Stability | ±0.1 °C |
| Penetration Resolution | 0.1 mm |
| Maximum Penetration Depth | 75 mm |
| Standard Compliance | ASTM D5, D217, D937, D1321, D1403, D1831, D2884 |
| Brand | FuLand / csfriend |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | FDS-0401 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Input Power | 800 W |
| Refrigeration Output | 2 × 400 W = 800 W |
| Ambient Temperature Range | Room Temperature to +30 °C |
| Operating Temperature Range | 20 °C to –70 °C |
| Refrigerants | R13 & R502 |
| Cooling Method | Air-Cooled |
| Temperature Control System | PID-Based Digital Thermostat |
| Sample Interface | Quick-Connect Fittings for LPG Cylinders and N₂ Purge Lines |
| Compressor Type | Imported High-Stability Unit |
| Brand | PULL |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PULL-1000mL |
| Rated Working Pressure | 4 MPa |
| Capacity | 1000 mL |
| Material | Stainless Steel (316 SS typical for anhydrous ammonia service) |
| Compliance | GB 8570–2008 “Sampling of Laboratory Samples of Anhydrous Liquid Ammonia” |
| Brand | FORZA |
|---|---|
| Origin | USA |
| Model | RU-D665-L-4/6 |
| Test Positions | 4 or 6 independent stations |
| Stirrer Speed | 1000 rpm |
| Temperature Range | +40 °C to +80 °C |
| Temperature Stability | ±0.5 °C |
| Bath Material | Stainless Steel with Drain Port |
| Compliance | ASTM D665, NACE TM01-72, GB/T 11143 |
| Brand | LISICO |
|---|---|
| Origin | Shanghai, China |
| Model | LS-O (Rotating Bomb Oxidation Method) |
| Detection Parameter | Oxidation Stability |
| Temperature Control Points | 140.0 ± 0.1 °C and 150.0 ± 0.1 °C |
| Rotation Speed | 100 ± 5 rpm |
| Pressure Range | 0–1.6 MPa (Pressure Sensor Accuracy: ±0.1% FS |
| Precision Gauge | 0.25 Class) |
| Power Consumption | ≤1400 W |
| Dimensions | 300 × 500 × 500 mm (W × D × H) |
| Weight | 40 kg |
| Compliance Standards | SH/T 0193, ASTM D2272 |
| Interface | Ethernet for LIMS integration |
| Data Storage | Local HDD with persistent multi-test archive |
| Max Concurrent Units per PC | 4 |
| Brand | LISICO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | LS-U |
| Detection Principle | Ultraviolet Fluorescence (UVF) |
| Portability | Benchtop (Non-portable) |
| Analyte | Total Sulfur |
| Measurement Range | 0.1 mg/L to >10,000 mg/L (0.2 ppm to >1% w/w) |
| Accuracy | ±0.1 mg/L (for 0.1 ≤ X < 1.0 mg/L) |
| Sample Volume | 5–50 µL (liquid) |
| Carrier Gas | Ultra-high-purity Argon (99.999%) and Oxygen (99.999%) |
| Furnace Temperature Range | Ambient to 1150 °C ±2 °C |
| Operating Environment | 5–30 °C, stable ambient conditions |
| Power Supply | 220 V ±10%, 50 Hz, 3 kW (15 A) |
| Software Interface | Switchable Chinese/English GUI |
| Compliance Standards | SH/T 0689, ASTM D5453, ASTM D4629, ASTM D5762 |
| Data Management | LIMS-ready architecture with audit trail capability |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi880 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0002 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Optical Path Length | 0.1–153 mm |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Data Storage Capacity | 100,000 measurements |
| Interfaces | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Power Supply | 90–240 V AC (external adapter) |
| Housing | Steel with textured epoxy coating |
| Dimensions & Weight | 515 × 195 × 170 mm / 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| Optional Heater | Up to 95 °C |
| Language Support | English, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Japanese |
| Software Features | GLP-compliant reporting, operator ID, sample ID, timestamp, RCMSi remote calibration and maintenance system |
| Built-in Color Scales | Lovibond RYBN, ASTM D1500, IP 17, ICUMSA, AOCS, Saybolt, CIE XYZ/xyY, spectral reflectance data |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Instrument |
| Model | LPC500 + Avio500 |
| Application | Elemental Analysis & Particle Counting in Lubricants |
| Sample Volume | <1 mL per dual analysis |
| Cycle Time | ≤45 seconds per sample |
| Brand | FORZA |
|---|---|
| Origin | USA |
| Model | LTRV-D2983-L-10 |
| Standards Compliance | ASTM D2983, ISO 9262, IP 267, GB/T 11145 |
| Temperature Range | +20 °C to –55 °C |
| Bath Type | Liquid-immersion thermal bath with nitrogen purge |
| Sample Capacity | 10 samples per bath |
| Control Interface | Integrated touchscreen controller with real-time bath temperature display |
| Cooling Profile | Programmable air-bath emulation mode |
| Viewing | Full panoramic optical access to samples in bath |
| Mounting | Direct floor-standing installation—no wooden pallet or external support required |
| Brand | FORZA |
|---|---|
| Origin | USA |
| Model | HFLT-AFNOR-M-2 |
| Standards Compliance | IP 448, ISO 13357, AFNOR NF E 48-690 & NF E 48-69, SH/T 0805-2008 |
| Test Vessel Material | Stainless Steel |
| Vessel Volume | 350 mL |
| Pressure Control Accuracy | ±5 kPa |
| Independent Test Stations | 1, 2 or 4 (user-configurable) |
| Integrated Air Supply | Equipped with coalescing and desiccant filtration |
| Data Processing | Includes dedicated Windows-based calculation utility for automatic filtration performance reporting |
| Brand | TTZH |
|---|---|
| Origin | Germany |
| Model | RST-T200-P4 |
| Temperature Range | Ambient to 200 °C (±0.5 °C) |
| Rotational Speed | 165 rpm (adjustable 100–200 rpm) |
| Roller Mass | 5 kg ± 50 g |
| Dimensions | 700 × 730 × 690 mm |
| Weight | 70 kg |
| Compliance | ASTM D1831, SH/T 0122 |
| Interface Option | RS485 |
| Brand | TTZH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Available Upon Inquiry |
| Price | Request Quote |
| Max Pressure | 150 bar |
| Piston Test Load | 60–70 kN |
| Sample Capacity | Up to 0.5 kg |
| Power Supply | 3-Phase, 380 V, 50 Hz |
| Brand | csfriend (Fulande) |
|---|---|
| Origin | Hunan, China |
| Model | FDH-1702 |
| Standard Compliance | SH/T 0059 |
| Sample Mass | 65 g |
| Heating Method | Metal Bath |
| Temperature Control | 250 ± 0.5 °C |
| Timer Accuracy | 3600 s ± 0.1 s |
| Pressure Measurement | 20 mm H₂O ± 0.2 mm H₂O |
| Power Supply | AC 220 V ± 10 %, 50 Hz |
| Input Power | 1.4 kVA |
| Operating Ambient | 15–35 °C |
| Temperature Controller | Intelligent Programmable PID Controller |
| Heating Time to Setpoint | ~60 min |
| Sensor Type | Pt100 Resistance Thermometer |
| Vacuum System | Integrated Low-Noise Self-Developed Vacuum Module |
| Brand | FuLand / csfriend |
|---|---|
| Origin | Hunan, China |
| Model | FDT-1102 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Bath Temperatures | 24 °C and 93.5 °C |
| Heater Power | 2500 W (93.5 °C bath), 800 W (24 °C bath) |
| Temperature Sensor | PT100 platinum resistance thermometer |
| Air Diffuser Disc Diameter | 25.4 mm ±0.02 mm |
| Air Permeability of Diffuser | 3000–6000 mL/min at 2.4 kPa (250 mm H₂O) |
| Test Cylinder | 1000 mL calibrated glass cylinder |
| Integrated Air Supply System | Built-in eco-friendly diaphragm air pump |
| Cooling System | Integrated refrigeration unit for low-temperature testing |
| Timing Control | Digital electronic timer with auto-start/stop logic |