Petroleum Specialized Analytical Instruments
Filter
Showing 781–810 of 1345 results
| Brand | VINCI (France) |
|---|---|
| Origin | France |
| Model | RFP 1000 |
| Type | Reservoir Fluid Particle Precipitation Analyzer |
| Detection Principle | Near-Infrared Laser Scattering + Real-Time Visual Monitoring |
| Application Focus | Asphaltene and Wax Precipitation Onset Determination under Controlled Temperature & Pressure |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | RPV-1 |
| Compliance | ASTM D789, ISO 307, ASTM D4603, ASTM D2857, ASTM D1795, SCAN CM15:99, TAPPI T230-om94, ASTM D1243, USP <911>, ISO 1628 |
| Timing resolution | 0.001 s |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Micro-Z ULS |
| Detection Principle | Wavelength Dispersive X-ray Fluorescence (WDXRF) |
| Detection Limit | 0.2 ppm |
| Measurement Range | 0–5 wt% |
| Analysis Time | < 300 s |
| Excitation Source Power | 80 W |
| Vacuum Requirement | Yes (gas-free operation) |
| Power Supply | AC 200–240 V, 200 W |
| Operating Environment | 10–40 °C, RH < 80 % |
| Dimensions (W×D×H) | 45 × 41 × 43 cm |
| Weight | 40 kg |
| Compliance Standards | ASTM D2622, GB/T 11140, SH/T 0842 |
| Key | Brand: Rigaku |
|---|---|
| Origin | USA |
| Model | NEX QC |
| Detection Principle | Energy-Dispersive X-Ray Fluorescence (EDXRF) |
| Analyte | Total Sulfur |
| Detection Limit | 5 ppm |
| Measurement Range | 0–10 wt% |
| Sample Volume | 5 mL |
| Analysis Time | 1–999 s (default 300 s) |
| Calibration Method | Compton Scattering C/H Ratio Correction |
| Data Output | USB + Ethernet |
| Environmental Requirements | RH < 85% (no condensation), vibration-free, non-corrosive atmosphere |
| Compliance Standards | ASTM D4294, GB/T 17040 |
| Brand | Rigaku |
|---|---|
| Origin | USA |
| Model | NEX QC+ |
| Detection Principle | Energy-Dispersive X-ray Fluorescence (EDXRF) |
| Detection Limit | 2.3 ppm for S |
| Measurement Range | 0–10 wt% S |
| Accuracy (Relative Error) | ±0.0001 |
| Analysis Time | < 3 min (configurable from 1–999 s) |
| Sample Volume | < 5 mL |
| Elemental Range | Na (11) to U (92) |
| Compliance | ASTM D4294, GB/T 17040 |
| Portability | Handheld / Field-Deployable |
| Environmental Operating Range | 15–35 °C, RH < 85% (non-condensing) |
| Data Interface | USB + Ethernet |
| Matrix Correction | Compton Scattering C/H Ratio Normalization |
| Filtration | Multi-layer Composite Primary Beam Filters |
| Safety | Zero hazardous waste generation (no gas, liquid or solid effluent) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Supermini200+ |
| X-ray Tube | Pd anode, 50 kV / 4 mA, 200 W |
| Detection Limits | S: 0.1 ppm, Cl: 0.1 ppm, Si: 0.5 ppm, As: 0.2 ppm |
| Detection Range | 0–99.99% |
| Standard Compliance | SH/T 0842 (S), SH/T 0977 (Cl), SH/T 0993 (Si) |
| Optical System | Automated multi-crystal spectrometer with high-resolution crystal selection |
| Sample Handling | 12-position automatic sampler |
| Sample Types | Liquids (gasoline, diesel, naphtha, jet fuel, crude oil, residuum, water, wastewater), solids (catalysts, polypropylene, powders) |
| Brand | PSL-Rheotek |
|---|---|
| Origin | United Kingdom |
| Model | RPV-3 |
| Temperature Range | 10 °C to 135 °C (±0.01 °C) |
| Measurement Precision | ±0.1 s for efflux time |
| Capillary Type | Ubbelohde (UKAS-certified, PTFE- and borosilicate glass-wetted materials) |
| Cleaning System | Automated Safe-Vac rinse cycle |
| Detection Method | Near-infrared (NIR) optical timing |
| Sample Handling | Robotic autosampler integration |
| Compliance | ASTM D2857, ISO 1628-1/2/3/4/5, ASTM D4603, ISO 307, ISO 5351, ASTM D4243, IEC 60450, ASTM D789, ASTM D1243, ASTM D1795, ASTM D871 |
| Data Interface | LIMS-compatible, GLP/GMP-compliant audit trail support |
| Brand | Rtec |
|---|---|
| Origin | USA |
| Model | BOR-3000 |
| Load Capacity | Up to 3000 N |
| Rotational Speed Range | 0.1–5000 rpm (0.1 rpm resolution) |
| Temperature Range | Ambient to +200 °C |
| Optional Low-Temp Control | −40 °C to +200 °C |
| Optional High-Temp Control | Ambient to +500 °C |
| Test Standards Compliance | ASTM G77, ASTM D2509, ASTM D2714, ASTM D2782, ASTM D2981, ASTM D3704, SH/T 0203, GB/T 11144 |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | BOR-3000 |
| Application | Friction and Wear Testing |
| Compliance | ASTM D3704, D2509, D2782, D2981, G77, G176 |
| Max Load | 10,000 N |
| Max Speed | 5000 rpm |
| Temp Range | Up to 500 °C |
| Torque Measurement | In-line high-resolution |
| Test Modes | Continuous, Reciprocating, Stepped Load, Oscillatory |
| Sample Mounting | Modular block holder for shafts, bearings, seals, rings, thrust/conical rollers |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | FBT-1000 |
| Test Types | EP (Extreme Pressure) and Wear Testing |
| Temperature Range | –40 °C to 200 °C (optional up to 400 °C) |
| Maximum Load | 12,000 N |
| Rotational Speed | Up to 1800 rpm |
| Real-time Monitoring | Torque, Load, Temperature, Acoustic Emission, Friction Coefficient |
| Compliance | ISO 12583, ASTM D2266, D2596, D2783, D4172, DIN 51350, BS EN ISO 20623, CEC L-45-A-99 |
| Sample Compatibility | Lubricating oils, greases, additives, solid lubricants |
| Data Resolution | Sub-micron wear scar measurement via integrated 3D profilometry |
| Brand | Rtec |
|---|---|
| Origin | USA |
| Model | FBT-12000 |
| Load Capacity | Up to 12,000 N (closed-loop servo-controlled) |
| Torque Measurement Range | 0–20 N·m |
| Rotational Speed | 0–3000 rpm (0.1 rpm resolution) |
| Temperature Range | Ambient to +150 °C |
| Optional Low-Temperature Control | Ambient to –40 °C |
| Compliance | ASTM D2596, D2783, D2266, D4172, D5183 |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | FFT-M |
| Application | Lubricity & Wear Evaluation of Diesel/Gasoline Fuels |
| Standards Compliance | ASTM D6079, ISO 12156-1, SH/T 0765-2005 |
| Frequency Range | 0.1–300 Hz |
| Stroke | 10 µm–4.0 mm |
| Load Capacity | Up to 10 N or 300 N (configurable) |
| Temperature Range | −40 °C to +500 °C |
| Humidity Control | 5–95% RH (closed-loop) |
| Ball Diameter | Standard 6 mm (1.6–12.7 mm optional) |
| Disk Dimensions | 10 mm diameter × 3 mm thickness (custom sizes available) |
| Real-time Force Feedback | Piezoelectric load sensor |
| Friction & Wear Output | Dynamic coefficient of friction, total wear scar depth, acoustic emission, in-situ film formation monitoring |
| Environmental Control | Inert gas purge capability (N₂, Ar), programmable atmosphere management |
| Brand | Rtec |
|---|---|
| Origin | USA |
| Model | FFT-M1 |
| Application | Tribological Evaluation of Fuels and Lubricants |
| Compliance | ASTM D6079, ISO 12156-1, SH/T 0765, EN 590, JPI-5S-50-9, IP 450 |
| Load Range | 0–1.0 kg |
| Frequency Range | 1–300 Hz |
| Stroke Amplitude | 0.005–2 mm |
| Operating Temperature | Ambient to +200 °C |
| Test Mode | Boundary Lubrication Assessment under Oscillatory Sliding Conditions |
| Brand | Rtec |
|---|---|
| Origin | USA |
| Model | MFT-3000 |
| Load Range | 0–3000 N |
| Reciprocating Stroke | 0–30 mm |
| Frequency Range | 0–80 Hz |
| Temperature Control | Ambient to +500 °C (up to +1000 °C optional) |
| Low-Temperature Option | Ambient to –60 °C |
| Thermal Cycling Option | –40 °C to +180 °C |
| Rotational Mode (optional) | 0.1–5000 rpm, 0.1 rpm resolution |
| Compliance | ASTM G133, G181, G119, G174, D5706, D5707, SH/T 0784, SH/T 0721, DIN 51834 |
| Brand | Rtec |
|---|---|
| Origin | USA |
| Type | Electromagnetic Oscillating Tribometer |
| Load Range | 1–3000 N |
| Frequency Range | 1–500 Hz |
| Oscillation Amplitude | 0.005–4 mm |
| Temperature Range | Ambient to +400 °C (optional up to +1000 °C) |
| Force Sensing | High-accuracy piezoelectric tribosensors |
| Displacement Monitoring | LVDT-based real-time closed-loop control |
| Compliance Standards | ASTM D5706, D5707, D6425, D7421, D7594, E2789 |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | TTQ-1000 |
| Application | Tribological Evaluation of Cutting, Threading & Drilling Lubricants |
| Measurement Principle | In-situ Rotational Torque + Acoustic Emission + Electrical Contact Resistance + Environmental Temperature Monitoring |
| Sample Types | Aluminum, Steel, and Other Machinable Metals |
| Test Modes | Automated Multi-position Tapping, Drilling, and Milling Simulation |
| Compliance Context | Supports ASTM D3702, ISO 20623, and GLP-aligned data integrity requirements |
| Brand | Rubolab |
|---|---|
| Model | Smart Filtration Kit |
| Origin | Spain |
| Instrument Type | Online Monitoring System |
| Measured Parameters | Foam Characteristics, Particle Count (ISO/NAS Code), Demulsibility Indicator (via OilWear Sensor Platform), Optional Water Content (ppm) |
| Flow Control | Integrated Flow Meter & Regulator |
| Compliance | ISO 4406, ISO 11171, ASTM D892, ASTM D2711, ISO 6247 |
| Software | Rubolab OilWear™ Cloud Platform with Audit Trail & Exportable CSV/Excel Reports |
| Certifications | CE, RoHS, Designed for GLP/GMP Environments |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | SA9000-0 |
| Compliance | ASTM D1655, ASTM D8073, IP 624 |
| Automation Level | Fully Automated Sample Handling |
| Mixing Technology | Patented 40 kHz Ultrasonic Homogenizer with Resonant Ceramic Transducer |
| Water Detection Limit | <1 ppm (by mass) |
| Emulsification Method | Acoustic Cavitation in Fuel-Water Mixtures |
| Filter Test Medium | Fifth-Generation Hydrophobic Coalescer Media |
| Sample Preparation | Precision Volumetric Dispensing System |
| Brand | Santiyiqi |
|---|---|
| Model | ST-DT01 |
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Price | USD 17,200 (FOB) |
| Sample Volume | 1 mL |
| Analysis Time | < 10 min |
| Display | 7-inch capacitive touchscreen |
| Microprocessor | Embedded self-diagnostic ARM-based controller |
| Connectivity | 4× USB 2.0 ports, 1× RJ45 Ethernet port |
| Operating System | Windows 7 Embedded |
| Power Input | 220 VAC ±10%, 50 Hz (converted to 12 VDC/5 A internally) |
| Magnetic Field Gradient | >5.0 T/cm |
| Maximum Magnetic Flux Density | >1.5 T |
| Measurement Resolution | 0.1 (unitless index scale) |
| Solvent Compatibility | Perchloroethylene (C₂Cl₄) |
| Sampling Method | Automated syringe-driven aspiration |
| Electromagnetic Immunity | Enhanced EMI shielding per IEC 61326-1 Class B |
| Portability | Benchtop with integrated carry handle and shock-absorbing chassis |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CV-100 |
| Pricing | Upon Request |
| Measurement Principle | Falling Needle (Capillary-Free Gravitational Sedimentation) |
| Viscosity Range | Up to 1 × 10⁹ cP |
| Time Resolution | 0.001 s |
| Temperature Control | Optional Water Jacket (–40 to 150 °C) |
| Interface | RS-232 |
| Sample Tube | Disposable Polypropylene Caulking Tube (reusable up to 30× with proper cleaning) |
| Compliance | ASTM D1084, ISO 2555, USP <911>, GLP-compatible data logging |
| Brand | SBS |
|---|---|
| Origin | USA |
| Model | DV-100 |
| Viscosity Range | 0.7–10⁶ cP (mPa·s) |
| Temperature Range | 0–100°C |
| Accuracy & Repeatability | <1% |
| Sample Volume | 4.5 cm³ |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density Range | 6–130 g/cm³ |
| Falling-Time Resolution | 0.001 s |
| Instrument Weight | 7.3 kg |
| Interface | RS-232 |
| Sample Tube | Disposable (reusable up to 30×) |
| Brand | SBS |
|---|---|
| Origin | USA |
| Model | FNV-200 / CNV-100 |
| Viscosity Range (FNV) | 0.5–2.4×10⁶ cP |
| Viscosity Range (CNV) | 0.1–30 cP |
| Shear Rate Range (FNV) | ~10⁻⁴–10⁴ s⁻¹ |
| Temperature Range | −40 to 150 °C |
| Accuracy & Repeatability | <1% |
| Sample Volume (FNV) | ~110 cm³ |
| Sample Volume (CNV) | ~85 cm³ |
| Needle Material | Aluminum, Titanium, Stainless Steel, or Borosilicate Glass |
| Needle Density Range | 1.01–8.0 g/cm³ |
| Instrument Weight | 18.2 kg |
| Dimensions (H×W) | 55 × 36 cm |
| Falling Time Resolution | 0.001 s |
| Interface | RS-232 |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HPHTV-100 |
| Viscosity Range | 0.7–10⁶ cP (mPa·s) |
| Temperature Range | 0–100°C (operational), up to 150°C (chamber capability) |
| Pressure Rating | Up to 2000 psi |
| Accuracy & Repeatability | <1% |
| Sample Volume | 4.5 cm³ |
| Needle Materials | Aluminum, Titanium, Stainless Steel |
| Needle Density Range | 6–130 g/cm³ |
| Falling-Time Resolution | 0.001 s |
| Console | Microprocessor-based with RS-232 interface |
| Automatic Needle Handling | Yes |
| Instrument Weight | 7.3 kg (16 lbs) |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HTV-100 |
| Pricing | Available Upon Request |
| Viscosity Range | 1–10⁸ cP (mPa·s) |
| Temperature Range | −40 to 200°C (standard) |
| Accuracy & Repeatability | < ±2% |
| Sample Volume | ~1.5 cm³ |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density Range | 6–1000 g/cm³ |
| Instrument Weight | 5.4 kg (12 lbs) |
| Measurement Resolution | 0.001 s |
| Interface | RS-232 |
| Sample Tube | Disposable, No Cleaning Required |
| Brand | SBS |
|---|---|
| Origin | USA |
| Model | PDVa-100 |
| Viscosity Range | 0.7–10⁷ cP (mPa·s) |
| Temperature Range | Ambient |
| Accuracy & Repeatability | <1% |
| Sample Volume | ~4.5 cm³ |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density Range | 6–130 g/cm³ |
| Instrument Weight | 2 kg (4.4 lbs) |
| Measurement Principle | Capillary-based falling-needle viscometry with automated timing |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PDVdi-120 |
| Price | Upon Request |
| Viscosity Range | 2–10⁶ cP (mPa·s) |
| Temperature Range | Ambient (15–30 °C typical field use) |
| Accuracy & Repeatability | ±2% of reading |
| Sample Volume | ~25 mL |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density | 2.916 g/cm³ |
| Total Weight | 0.38 kg (0.83 lbs) |
| Compliance | ASTM D5478, SAE AIR5704 |
| Brand | SBS |
|---|---|
| Origin | USA |
| Model | SV-100 |
| Viscosity Range | 0.5–10,000 mPa·s |
| Temperature Range | −40 to +150 °C |
| Accuracy & Repeatability | < ±2% |
| Sample Volume | ≥1.5 cm³ |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density | ~7.0 g/cm³ |
| Operating Pressure | Up to 2,000 psi |
| Compliance | ASTM D5478 |
| Instrument Weight | 7.3 kg |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UHPV-100 |
| Price | Upon Request |
| Viscosity Range | 0.7–20,000 cP (mPa·s) |
| Pressure Range | Up to 60,000 psi |
| Temperature Range | −40 to +150 °C |
| Accuracy & Repeatability | < ±2% |
| Sample Volume | ~10 cm³ |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density | 7 g/cm³ |
| Instrument Weight | 68.0 kg (150 lbs) |
| Dimensions (H×W×D) | 61 × 107 × 61 cm |
| Brand | SCAVINI |
|---|---|
| Origin | Germany |
| Model | AD113 |
| Temperature Range | −10 °C to 40 °C |
| Ductility Extension Lengths | 50 cm, 100 cm, 150 cm |
| Load Measurement Range | 0–200 N |
| Load Resolution | 0.5 N |
| Temperature Control Accuracy | ±0.1 °C |
| Bath Material | Stainless Steel with PTFE-coated base |
| Cooling System | Integrated hermetic refrigeration compressor |
| Drive Mechanism | Variable-speed electric motor |
| Sample Capacity | 2 specimens simultaneously |
| Data Interface | RS-232 |
| Compliance | ASTM D113, ASTM D5976, IP 32, ISO 1208, GB/T 4508 |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Model | SD-1 |
| Standards Compliance | ASTM D6450, SH/T 0768, DL/T 1354 |
| Measurement Method | Closed-Cup Pensky-Martens Equivalent (Automated Peltier-Cooled Ignition Detection) |
| Sample Volume | ≤ 2 mL |
| Test Time | Typically < 10 min per sample |
| Display | 7-inch Capacitive LCD Touchscreen (Android OS 8.1) |
| Data Output | Thermal Printer (Built-in), USB Export, Optional Ethernet/Wi-Fi Module |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions | 320 × 280 × 220 mm |
| Weight | 8.5 kg |