Petroleum Specialized Analytical Instruments
Filter
Showing 841–870 of 1348 results
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 15550-2 |
| Temperature Range | Ambient to 150 °C |
| Temperature Stability | ±0.1 °C |
| Bath Medium | Water or Oil |
| Bath Volume | 35 L |
| Power Rating | 1500 W |
| Voltage Options | 110/120 V or 220/240 V, 50/60 Hz |
| Dimensions (W×D×H) | 41 × 45 × 33 cm |
| Weight | 10 kg |
| Test Positions | 4 |
| Construction Material | Stainless Steel |
| Controller Type | Digital with Over-Temperature and Low-Level Safety Interlocks |
| Optional Accessory | Automated Pressure Monitoring Module |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 15840-0 |
| Standards Compliance | ASTM D3427, IP 313, BS 2000-313, ISO 9120, DIN 51381, NFT 60-149, SH/T 0308 |
| Temperature Range | Ambient to 75 °C |
| Temperature Stability | ±0.2 °C |
| Touchscreen Interface | 7-inch LCD with Embedded Control Software |
| LIMS Connectivity | Yes |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 16120-2 |
| Standard Compliance | ASTM D4870, IP 375 (Procedure A), IP 390 (Procedure A), ISO 10307-1 & ISO 10307-2, BS 2000-375, NF M07-063, SH/T 0701, SH/T 0702 |
| Sample Mass | 10 g |
| Flask Capacity | 500 mL |
| Filter Paper Requirement | 2 sheets per test |
| Operating Temperature | 80 °C (sample heating), 100 °C (steam jacket) |
| Vacuum Pressure | 40 kPa |
| Cooling Water | Ambient temperature |
| Dimensions | 40 × 47 × 18 cm |
| Weight | 8 kg |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 16670-0 |
| Heating Method | Solid (metal block) |
| Temperature Range | Ambient to 100 °C |
| Test Positions | 4 |
| Voltage | 200–240 V, 50/60 Hz |
| Power Consumption | 3 kW |
| Dimensions (W×D×H) | 30 × 60 × 28 cm |
| Weight | 65 kg |
| Compliance | ASTM D525, D873, D2274, D4310, D7462 |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 22100-0 |
| Maximum Operating Pressure | 1400 kPa (200 psi) |
| Temperature Range | −20 °C to +60 °C |
| Test Chamber Burst Pressure | 2800 kPa |
| Compliance | ASTM D1657, BS EN ISO 3993, IP 235, SH/T 0221 |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 22210-3 |
| Temperature Range | 5°C to 90°C (ambient referenced) |
| Temperature Uniformity | ±0.1°C at 37.8°C |
| Bath Volume | 80 L |
| Capacity | Up to six RVP test bombs |
| Power Supply | 220/240 V, 50/60 Hz |
| Power Consumption | 2.2 kW |
| Dimensions (W × D × H) | 77 × 55 × 51 cm |
| Weight | 70 kg |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 22220-4 |
| Temperature Range | Ambient to 100 °C |
| Temperature Stability | ±0.2 °C |
| Bath Volume | 38 L |
| Voltage | 110–120 V / 220–240 V, 50/60 Hz |
| Power Rating | 1.4 kW |
| Dimensions (W×D×H) | 60 × 35 × 33 cm |
| Weight | 9 kg |
| Test Positions | 3 |
| Control System | Digital PID temperature controller with LED display |
| Internal Agitation | Integrated mechanical stirrer |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 35000-0 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Temperature Range | +5 °C to 400 °C |
| Temperature Resolution | ±0.1 °C |
| Heating Rates | 1.0, 1.3, 3.0, 5.5 °C/min (standard) |
| Stirring Speed | 105 or 250 rpm |
| Ignition Options | Electric spark or gas flame (user-selectable in menu) |
| Atmospheric Pressure Correction | Integrated digital barometer with automatic flash point compensation |
| Display | 8.4-inch color touchscreen (Chinese UI) |
| Data Storage | ≥2000 test records, 30 programmable methods |
| Connectivity | Ethernet and RS-232 |
| Dimensions | 38.5 × 24 × 50 cm |
| Weight | 25 kg |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 99700-4 |
| Conductivity Range | 0.0 to 430.0 g/m³ (as NaCl) |
| Temperature Range | −20 °C to +150 °C |
| Power Supply | 9 V alkaline battery or universal AC adapter (110–240 V, 50/60 Hz) |
| Dimensions | 200 × 70 × 35 mm |
| Weight | 1.6 kg |
| Compliance | ASTM D3230, IP 265 |
| Interface | RS232 serial output |
| Brand | SetaAnalytics |
|---|---|
| Origin | United Kingdom |
| Model | SA4000-4 |
| Compliance | ASTM D7621, IP 570 |
| Measurement Range | 0–250 mg/kg H₂S (ppm) |
| Analysis Time | 15 min |
| Operating Temperature | 5–40 °C |
| Sample Volume | 1 mL / 2 mL / 5 mL |
| Viscosity Limit | ≤3000 mm²/s at 40 °C |
| Interface | RS232 |
| Power | 60 W |
| Dimensions | 21 × 30 × 41 cm |
| Weight | 8 kg |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | SA5000-2 |
| Measurement Range | 10–400 mg/kg FAME in Aviation Turbine Fuels |
| Analysis Time | ≤20 min per sample |
| Sample Volume | ≤50 mL |
| Operating Temperature | 5–40 °C (max. 80% RH) |
| Dimensions | 36 × 37 × 45 cm |
| Weight | 16 kg |
| Interface | USB |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 81000-2 |
| Analysis Method | Reid Vapor Pressure (RVP) |
| Pressure Range | 0–200 kPa |
| Temperature | 37.8 °C ± 0.1 °C |
| Sample Volume | 3 mL |
| Vapor-to-Liquid Ratio | 4:1 |
| Pressure Resolution | 0.1 kPa |
| Accuracy | ±0.5 kPa |
| Vacuum Requirement | < 0.01 kPa |
| Interface | RS232C |
| Power | 110/120 V or 220/240 V, 50/60 Hz, 70 W |
| Dimensions | 37 × 13 × 20 cm |
| Weight | 3.5 kg |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 82000-2 |
| Test Method | Closed-Cup (Rapid Equilibrium / Constant Rate of Rise) |
| Automation Level | Fully Automatic |
| Temperature Range | −20 °C to 130 °C or Ambient +5 °C to 300 °C |
| Sample Volume | 2–4 mL |
| Ignition Source | Selectable Electric Spark or Gas Flame |
| Compliance | ASTM D3278, D3828, D7236 |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | SETAFLASH Series 3 |
| Detection Method | Closed-Cup |
| Temperature Range | 0 °C to 300 °C |
| Ignition Mode | Electric or Gas Ignition |
| Compliance Standards | ISO 3679 |
| Sample Volume | 2 mL (for samples with expected flash point ≤100 °C), 4 mL (for >100 °C) |
| Cooling Time | ≤4 min (from 80 °C to 20 °C, optional) |
| Test Duration | 1–99 min |
| Interface Options | RS232, USB, LAN |
| Power | 200 W / 300 W |
| Voltage | 100–250 V AC, 50/60 Hz |
| Cup Materials | Anodized Aluminum, Corrosion-Resistant Stainless Steel |
| [Brand | Shanghai Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | AP-L1S |
| Temperature Range | Ambient to 170 °C |
| Repeatability | ±0.2 °C (light-colored oils), ±0.4 °C (dark-colored oils, ASTM Color > 8) |
| Temperature Sensor | Pt100 platinum resistance thermometer |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Power | 30 W |
| Stirring Motor Power | 6 W |
| Display | Touch-enabled LCD panel |
| Data Storage | 99 test records |
| Interface | RS232 serial port |
| Printer | Integrated thermal dot-matrix printer |
| Dimensions | 400 × 430 × 450 mm (W×D×H) |
| Weight | ~24 kg] |
| Brand | Shanghai Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | KV-L12 |
| Temperature Range (w/ 40RC) | −40 °C to 100 °C |
| Temperature Range (w/ 60RC) | −60 °C to 100 °C |
| Bath Dimensions | Ø190 × 270 mm |
| Number of Test Ports | 2 |
| Temperature Display Resolution | 0.01 °C |
| Temperature Uniformity | ±0.02 °C |
| Temperature Stability | ±0.02 °C |
| Circulation Pump Flow Rate | 1.9 L/min |
| Circulation Pump Head | 3 m |
| Heating Power | 1.5 kW |
| Refrigeration Power (w/ external chiller) | 1.2 kW |
| Power Supply | AC 220 V, 50/60 Hz |
| Net Weight | 27 kg |
| External Dimensions | 380 × 400 × 620 mm (L × W × H) |
| Compliance | GB/T 265, ASTM D445, ISO 3104, IP 71 |
| Brand | Shanghai Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | RLP-6 |
| Temperature Control Range | 10°C to 80°C (standard test at 60 ± 1°C) |
| Temperature Accuracy | ±0.5°C |
| Sample Capacity | 6 positions |
| Bath Dimensions | 816 × 180 × 200 mm (W×D×H) |
| Overall Dimensions | 1000 × 260/340 × 720 mm (W×D×H) |
| Heating Power | 2000 W |
| Bath Stirring Motor | AC 220 V, 25 W |
| Sample Stirring Motor | DC 24 V, 50 W, 1500 ± 25 rpm |
| Beaker Volume | 400 mL |
| Pt100 Sensors | 6-channel independent temperature monitoring |
| Timer Function | 6 independent digital timers |
| Compliance | GB/T 11143–2008, ASTM D665 |
| Brand | Shanghai Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | XF-323 |
| Standards Compliance | GB/T 8017, ASTM D323, ISO 3007, IP 69 |
| Instrument Type | Benchtop, 2- or 4-position miniature bomb configuration |
| Measurement Range | 0–196 kPa (0–2 kgf/cm²) |
| Test Bomb | Full stainless-steel Reid vapor pressure bomb |
| Data Output | Integrated thermal dot-matrix printer |
| Dimensions (W×D×H) | 400 × 600 × 740 mm |
| Weight | 45 kg |
| Power Consumption | 2.0 kW |
| Optional Accessory | Certified mercury manometer (Japan-manufactured, for calibration verification) |
| Origin | Russia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Shatox Portable |
| Pricing | Available Upon Request |
| Origin | Russia |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | SHATOX SX-100K |
| Price | Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SHATOX SX-100M |
| Pricing | Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SHATOX SX-200 |
| Price | Upon Request |
| Origin | Russia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SHATOX SX-300 |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | SHATOX-2212 |
| Measurement Range (Octane) | 40–120 (±0.5) |
| Measurement Range (Cetane) | 20–100 (±1) |
| Sample Measurement Time | <10 s |
| Display | LCD digital readout |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | 30–80% RH |
| Atmospheric Pressure | 64–106 kPa |
| Power Supply | 6 V DC adapter or AA batteries |
| Current Consumption | 30 mA |
| Battery Life | Up to 100 h |
| Dimensions (Sensor) | 60 × 100 mm |
| Dimensions (Main Unit) | 80 × 150 × 30 mm |
| Weight | 0.7 kg |
| Data Export Format | .txt and .xls |
| Interface | RS-232 |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Model | SD 5096 |
| Power Supply | 220 V ±10%, 50 Hz |
| Temperature Control Range | Ambient to 200 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Sensor | Industrial Pt100 Platinum Resistance Thermometer |
| Heating Power | 2100 W |
| Timing Range | 0.01 s to 99 h 99 min |
| Display | LED digital for both temperature and time |
| Sample Capacity | 4 test positions |
| Compliance | GB/T 5096, ASTM D130, ASTM D3241, SH/T 0023 |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SD-2801A |
| Temperature Control Range | Constant 25 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Penetration Measurement Accuracy | ±1 penetration unit |
| Maximum Penetration Depth | 700 penetration units |
| Penetration Time Control Accuracy | ±0.1 s |
| Resolution | 0.01 mm |
| Standard Cone Mass | 102.5 ± 0.05 g |
| Standard Needle Mass | 2.5 ± 0.05 g |
| Sample Cup Dimensions | Ø100 mm × ≥65 mm |
| Power Consumption | 80 W |
| Dimensions (L×W×H) | 340 × 282 × 515 mm |
| Net Weight | 11 kg |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SH0536 |
| Measurement Principle | Microcoulometric Titration (Ag⁺/Cl⁻ Reaction) |
| Compliance | SY/T 0536, ZBE 21001–1987 |
| Sample Types | Crude oil, residual fuel oil, heavy oil, refinery wastewater, industrial process water |
| Salt Range | 0.2 ppm – 10,000 mg NaCl/L |
| Chloride Range | 0.1 ppm – 10,000 mg Cl⁻/L |
| Accuracy | ≤20% (NaCl <3 mg/L), ≤10% (3–10 mg/L), ≤8% (≥10 mg/L) |
| Repeatability | ≤0.3 mg/L (NaCl <3 mg/L), ≤1.2 mg/L (3–10 mg/L), ≤8% RSD (≥10 mg/L) |
| Electrolytic Cell Design | Fritted Glass Disc (Replaces Ion-Exchange Membrane) |
| Control System | Embedded Microprocessor + PC-Based Data Acquisition & Visualization |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | SH0702 |
| Price Range | USD 1,400 – 7,000 |
| Sample Mass | 25 g |
| Waste Flask Capacity | 500 mL |
| Measured Sediment Range | 0.5 % (m/m) |
| Test Stations | 2 |
| Filter Paper | Glass Fiber, Pore Size 1.6 µm, Diameter 47 mm |
| Vacuum Pressure | 40 kPa |
| Applicable Standards | SH/T 0701, SH/T 0702 |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 1000 W |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SH109 |
| Price Range | USD 7,000 – 14,000 |
| Standard Compliance | GB/T 17144-2021, ASTM D4530, ISO 10370:1993 |
| Measurement Range | 0.10–30.0 % (m/m) |
| Temperature Range | Ambient to 500 °C |
| Isothermal Accuracy | 500 °C ±2.0 °C (15 min hold) |
| Nitrogen Supply Pressure | 0–392 kPa (adjustable) |
| Gas Flow Control | 100–1000 mL/min, with auto-switching between 150 mL/min and 600 mL/min |
| Furnace Chamber Dimensions | Φ85 mm × 105 mm |
| Waste Collection Bottle Capacity | 200 mL |
| Heating Power | 1000 W |
| Power Supply | AC 220 V ±10%, 50 Hz |
| External Dimensions | 230 × 320 × 425 mm |
| Time Setting Resolution | <0.1 s |
| Display & Control | Color LCD touchscreen interface with real-time status indicators (Purge / Ramp / Soak) |
| Data Output | Optional thermal printer support |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | SH113C |
| Temperature Range | +30 °C to –70 °C |
| Compliant Standards | GB/T 3535 |
| Detection Method | Imported photoelectric switch detection |
| Human-Machine Interface | 7-inch color LCD touch screen |
| Refrigeration System | Dual-stage hermetic compressor refrigeration |
| Bath Type | Dry well-shaped metal bath |
| Temperature Control Accuracy | < ±0.1 °C |
| Sample Capacity | Single test tube (marked fill line) |
| Data Storage | Up to 199 test records internally |
| Output Options | Built-in thermal printer |
| Power Management | Programmable auto-shutdown for compressor (0–50 min post-test) |
| Connectivity | TCP/IP network interface (optional remote firmware update) |
| Dimensions (W×D×H) | 650 × 480 × 620 mm |
| Net Weight | 75 kg |
