| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | PTB 311E |
| Hardness Range | 2–330 ±1 N |
| Thickness Range | 2–15 mm |
| Diameter/Length Range | 2–40 mm |
| Measurement Modes | Constant-Force & Constant-Speed |
| Force Units | N, kp, Sc |
| Dimension Units | mm, inch |
| Compliance | FDA 21 CFR Part 11 (via PTB32 software), GMP/GLP-ready |
| Interface | RS-232, Printer Port |
| Construction | Full Stainless Steel Housing |
| Brand | Pharma-Test |
|---|---|
| Origin | Germany |
| Model | PTB 330 |
| Compliance | USP <1217>, Ph. Eur. 2.9.8 |
| Test Modes | Linear Force Ramp & Linear Speed Ramp |
| Output Parameters | Hardness (N), Thickness (mm), Width (mm), Diameter/Length (mm), Mass (g, via external analytical balance) |
| User Authentication | Integrated Fingerprint Sensor |
| Data Management | Onboard Statistics (Mean, SD, RSD, Min/Max), Force-Profile Printing, Multi-Point Validation Protocol |
| Interface | Graphical Touchscreen GUI with Contextual Guidance |
| Connectivity | Optional Ethernet/Wi-Fi Network Integration |
| Mechanical Design | Dual-axis motorized actuator with calibrated load cell and precision linear encoder |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | PTB 500 |
| Compliance | USP <1217>, EP <2.9.8> |
| Test Modes | Dual-force (linear speed increase & linear force increase) |
| Measured Parameters | Hardness, Thickness, Width, Diameter/Length, Weight (via external analytical balance) |
| Integrated Components | Sample carousel, GUI-controlled actuation, statistical engine, network interface |
| Validation | Built-in multi-point validation protocol |
| Output | Force–displacement curve, full statistical summary (mean, SD, RSD, min/max), configurable print/export |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | PTF 10E / PTF 20E |
| Drum Configuration | Single-drum (PTF 10E) or Dual-drum (PTF 20E) |
| Rotation Speed | Fixed at 25 rpm (standard), adjustable 1–9999 rpm (ER variants) |
| Test Duration Range | 1–9999 seconds |
| Rotation Count Range | 1–9999 revolutions |
| Drum Material | Acrylic glass (PMMA), optional anti-static coating |
| Drum Angle | Standard 0° |
| Compliance | USP <1216>, Ph. Eur. <2.9.7>, JP <6.07> |
| Construction | Full stainless-steel housing (AISI 304) |
| Documentation | Factory-supplied IQ/OQ protocols included |
| Interfaces | RS232 serial port, parallel printer interface |
| GMP/GLP Conformance | Designed and validated for regulated pharmaceutical QC environments |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | PTF 200 |
| Drum Configuration | Dual-drum |
| Speed Range | 15–100 rpm |
| Operating Modes | Fixed revolutions or fixed time |
| Calibration Reminder | Programmable interval timer |
| Data Export | USB flash drive support |
| Sample Discharge | Automatic |
| Balance Interface | RS-232/USB for analytical balance integration |
| Compliance | USP <1216>, Ph. Eur. <2.9.7>, JP <14> |
| Optional | Built-in thermal printer |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | PTF 110 / PTF 210 / PTF 310 / PTF 610 |
| Drum Configuration | 1 / 2 / 3 / 6 drums |
| Construction | Brushed stainless steel housing |
| Drum interchangeability | Fully compatible across PTF 100–600 and PTF 110–610 generations |
| Compliance | Designed to meet USP <1216>, EP 2.9.7, and JP 6.05 requirements |
| Connectivity | PT-Node network adapter optional |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | PTS 3E |
| Sample Capacity | 3 units simultaneously |
| Temperature Range | 30–40 °C |
| Temperature Accuracy | ±0.5 °C (typical for pharmacopeial disintegration systems) |
| Water Bath Volume per Station | 1.2 L |
| Test Duration Range | 1 min – 10 h |
| Flip Cycle Interval | 1–10 min (programmable 180° rotation) |
| Acoustic Emission | <35 dB(A) (fully silent operation) |
| Heating System | PTC ceramic with overheat protection |
| Grease-Resistant Sealing | Integrated hydrophobic barrier at sample holder interface |
| Compliance | Designed to meet USP <701>, Ph. Eur. 2.9.1, and JP 6.05 disintegration requirements |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | PTWS 1420 |
| Instrument Type | Offline Dissolution Tester |
| Number of Vessels | 14 |
| Temperature Range | 25–45 °C |
| Temperature Accuracy | ±0.2 °C |
| Rotational Speed Range | 25–250 rpm |
| Paddle Wobble | ≤0.2 mm |
| Basket Wobble | ≤0.2 mm |
| Water Bath Temperature Resolution | ±0.2 °C |
| Water Bath Volume | 0.5 m³ |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | PTWS 820D |
| Instrument Type | Online Dissolution Tester |
| Compliance | USP <711>, USP <724>, EP 2.9.3/2.9.4, ChP (Chinese Pharmacopoeia), JP |
| Vessel Options | 250 mL, 1 L, 2 L, 4 L |
| Construction | Stainless Steel (GLP-compliant) |
| Automation Level | Fully Automated Online System with Integrated Sampling |
| Sampling Mechanism | EPE Robotic Arm with Precise Z-axis Positioning |
| Stirring Stations | 8 Independent Vessels |
| Method Storage | Unlimited Methods via USB |
| Validation Support | IQ/OQ/PQ Documentation & Services Available |
| Temperature Uniformity | Optimized Water Bath with Diffuser & Low-Noise Circulation Pump |
| Connectivity | USB (Remote Control & Data Export), RS232 (Printer Interface) |
| User Management | Password-Protected Role-Based Access |
| System Diagnostics | Pre-run Self-Check Routine |
| Alert System | Visual (LED) and Audible Status Indication |
| Cleaning | Removable Bath Assembly & Dedicated System Rinse Kit |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | PTWS 820D |
| Instrument Type | Offline Dissolution Tester |
| Compliance | USP <711>, USP <724>, Ph. Eur. 2.9.3 & 2.9.4, DAB, JP <15>, ChP |
| Sample Positions | 8 (4+4 arrangement) |
| Drive Mechanism | Single motor-driven vertical lift |
| Temperature Monitoring | Real-time auto-check at each sampling point |
| Data Storage | SD card (method storage capacity: >10,000 protocols) |
| User Access Control | Role-based authentication (admin/operator) |
| Status Indication | Tri-color LED traffic-light display (green = ready, yellow = warming/stabilizing, red = error/failure) |
| Calibration Support | Built-in OQ/PQ reminder prompts |
| Cup Sealing | Low-volatility precision-fit lid |
| Bath Accessibility | Tool-free water bath removal for cleaning |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | PTZ AUTO EZ |
| Basket Positions | 1–4 |
| Stroke Distance | 55 ± 1 mm |
| Disintegration Time Range | 1 s – 59 h 59 min 59 s |
| Temperature Control Range | 25–45 °C |
| Frequency | 30 ± 1 cycles/min |
| Compliance | USP <701>, EP 2.9.1, JP 17 |
| Software Interface | RS-232, USB (optional), Printer Port |
| Safety Features | Dual overtemperature protection |
| Construction | Full stainless steel (AISI 316L contact surfaces) |
| Regulatory Support | 21 CFR Part 11-compliant PTZ32 software with audit trail, electronic signatures, and user access control |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | PTZ AUTO |
| Basket Stations | 1–4 |
| Stroke Distance | 55 mm |
| Cycle Frequency | 30 cycles/min |
| Temperature Range | 30–45 °C |
| Disintegration Time Range | 1 s – 59 h 59 min 59 s |
| Method Storage Capacity | 16 methods |
| Construction | Full stainless steel |
| Compliance | USP <701>, USP <2040>, Ph. Eur. 2.9.1, Ph. Eur. 2.9.1.2 |
| Safety Features | Dual overtemperature protection, mobile external temperature probe, OQ/PQ status monitoring |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | WHT 4ME |
| Compliance | EP <2.9.8>, USP <1217> |
| Testing Parameters | Hardness (constant-speed or constant-force mode), Weight, Thickness/Height, Diameter/Length |
| Sample Capacity | 20-position auto-feeder, up to 250 tablets per run |
| Throughput Modes | Single-batch or multi-batch (up to 10 distinct tablet types/batches) |
| Software | WHT 32 compliant with FDA 21 CFR Part 11 (audit trail, electronic signatures, configurable data storage paths) |
| User Interface | Integrated high-resolution touchscreen PC |
| Sample Handling | Tool-free adaptation for round, oblong, rectangular, and irregularly shaped tablets |
| Mechanical Design | Patented tapping mechanism ensures precise tablet centering prior to hardness and diameter measurement |
| Regulatory Alignment | Designed for GLP/GMP environments |
| Brand | Pharmag |
|---|---|
| Origin | Germany |
| Model | Pharmag AC-3000 |
| Throughput | 3000 capsules/hour |
| Capsule Sizes | #00, #0, #1, #2, #3, #4 |
| Power Supply | 230 V AC, 50/60 Hz, Single-phase |
| Motor | 90 W, 1400 rpm, 230 V AC, Three-phase (Gearbox Reduction Ratio: 30:1) |
| Rated Power | 0.75 kW (including vacuum pump) |
| Vacuum Pump Capacity | 6 m³/h |
| Vacuum Suction Pump Capacity | 9 m³/h |
| Air Compressor | 50 L/min at 1.5 bar |
| Contact Materials | AISI 316 stainless steel |
| Control System | PLC-based automation |
| Compliance | GMP-compliant design, CE-certified |
| Brand | Pharmag |
|---|---|
| Origin | Germany |
| Model | Minipress 2 |
| Type | Benchtop GMP-Compliant Rotary Tablet Press |
| Max. Stations | 12 (configurable as 4×D, 4×B, 4×BB) |
| Max. Compression Force | 60 kN (6 ton) |
| Pre-compression Force | 20 kN (2 ton) |
| Max. Tablet Diameter | 23 mm |
| Max. Fill Depth | 20 mm |
| Max. Output | 27,600 tablets/hr |
| Drive System | AC Variable Frequency Motor |
| Feeding Options | Gravity or Forced Feeders |
| Tooling Compatibility | B, D, BB standard |
| Contact Materials | AISI 316 stainless steel |
| Safety | Interlocked guarding, emergency stop, mechanical overload protection |
| Regulatory Compliance | Designed per EU GMP Annex 1 & ISO 9001 |
| Optional Upgrades | Real-time compression force monitoring, vibration-damping feet, 316L turntable, automated tablet weight control integration |
| Brand | Pharmag |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Imported |
| Model | UGD |
| Pricing | Upon Request |
| Brand | Hanson |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PHOENIX RDS m2 |
| Pricing | Upon Request |
| Brand | Pilotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | YC-910 |
| Pricing | Upon Request |
| Throughput | 1–3 kg/hr |
| Extrusion Speed | 50 rpm |
| Spheronization Speed | 1400 rpm |
| Pellet Diameter Range | 0.3–3 mm |
| Disc Diameter | 250 mm |
| Power Rating | 3 kW |
| Compressed Air Requirement | 0.3 m³/h |
| Integrated Cooling System | Built-in Chilled Water Circulation Unit |
| Brand | PROCEPT |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 4M8-TriX Coater |
| Price Range | USD 55,000 – 68,000 |
| Brand | ProCepT (Belgium) |
|---|---|
| Origin | Belgium |
| Model | 4M8-TriX |
| Batch Capacity | 50 g – 1 kg |
| Fluidized Bed Volume | 1 L (for 50–200 g) or 4 L (for 200–1000 g) |
| 雾化 Nozzle Options | Dual-stream high-efficiency atomizer with interchangeable nozzle caps (orifice diameters: 0.15–1.2 mm) |
| System Design | Negative-pressure operation |
| Optional Accessories | Nitrogen recirculation loop, glovebox integration kit, in-process sampling port, removable spray head assembly |
| Brand | ProCepT (Belgium) |
|---|---|
| Origin | Belgium |
| Model | LFD |
| Vessel Capacity | 1 / 2 / 5 L (30–2,500 g API) |
| Operating Pressure Range | Up to 2 bar (standard glass vessel) |
| Temperature Range | −10 °C to +95 °C |
| Agitator | Variable-speed, vertically adjustable, bidirectional (clockwise/counter-clockwise) |
| Filter Plate Diameter | Standard 13 cm (for 2 L), optional 20 cm (1 L) or 50 cm (5 L) |
| Cake Height Range | 2–10 cm |
| Inert Gas Handling | Controlled N₂ purging and inert atmosphere maintenance |
| Vacuum System | Integrated with particulate filter, glass condenser, bypass valve, vacuum pump, and dynamic pressure control |
| Process Monitoring Parameters | Agitator torque, cake compression force, product temperature, agitator speed, filter pressure differential, system pressure, filtrate mass, jacket temperatures (vessel / condenser / filter) |
| Compliance | Designed for GMP/GAMP-compliant environments |
| Brand | PROCEPT |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Mi-Pro |
| Price Range | USD 55,000 – 68,000 |
| Batch Capacity | 100–700 g |
| Vessel Volume | 1 L (for 100–200 g) or 4 L (for 400–700 g) |
| Impeller Speed & Torque | 50–1350 rpm, up to 6000 mN·m |
| Chopper Speed | 500–5000 rpm |
| Brand | ProteinSimple |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MFI |
| Pricing | Available Upon Request |
| Brand | PSS (Particle Sizing Systems) |
|---|---|
| Origin | USA |
| Model | AccuSizer 780 A7000 AD |
| Detection Principle | Single Particle Optical Sensing (SPOS) |
| Measurement Range | 0.5 µm – 400 µm |
| Sensor Type | LE Series (Light Obscuration + Light Scattering) |
| Channel Resolution | 512 channels |
| Maximum Sample Concentration | 1 × 10⁹ particles/mL |
| Particle Sensitivity | ≤10 ppt (parts per trillion, by volume) |
| Automation Features | Auto-dilution, auto-sampling, auto-cleaning, auto-calibration |
| Compliance Context | Designed for USP <788>, USP <789>, ISO 21501-4, ISO 13322-2, and FDA 21 CFR Part 11–ready data integrity workflows |
| Brand | Particle Sizing Systems (PSS) |
|---|---|
| Origin | USA |
| Model | AccuSizer 780 A7000 APS |
| Detection Principle | Single Particle Optical Sensing (SPOS) |
| Size Range | 0.5 µm – 400 µm |
| Resolution | 512-channel |
| Max Sample Concentration | 10¹¹ particles/mL |
| Compliance | USP <729>, ChP 2015, 21 CFR Part 11, cGMP |
| Automation | Integrated auto-sampling, two-step auto-dilution, auto-detection, data processing, and auto-cleaning |
| Brand | PULUODY |
|---|---|
| Model | PLD-6001 |
| Origin | Shaanxi, China |
| Sensor Technology | 8th-Generation Dual-Laser Narrow-Beam Light Obscuration |
| Detection Range | 1–500 µm (optional 0.03–3000 µm) |
| Resolution | >95% (ChP 2015/2020 calibrated) |
| Channel Count | 1000 adjustable channels (user-definable from 4 to 128 size bins) |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow regulation |
| Sampling Accuracy | <±1% |
| Measurement Accuracy | <±3% (typical) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Sample Temperature Range | 0–80 °C |
| Environmental Operating Range | −15–50 °C |
| Compliance | ChP 2020 Appendix 0903, USP <788>, <789>, <797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 21510, GB/T 11446.9–2013, GB 8368, YBB 00272004–2015 |
| Software | V8.9 Particle Analysis Suite (PC & embedded touchscreen), 21 CFR Part 11 compliant with audit trail, electronic signature, role-based 5-level access control, data backup/recovery, and power-fail protection |
| Calibration Standards | JJG 1061, NIST-traceable latex spheres, ISO 21501-4 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601 |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Laser Source | Dual-narrow-beam laser diode array (8th-generation) |
| Sensor Resolution | 1000 channels, down to 0.01 µm |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow regulation |
| Sample Volume Accuracy | < ±1% |
| Counting Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Channel Flexibility | User-definable size bins (e.g., 4–70 µm(c), 1–100 µm, or 0.1 µm(c)) |
| Flow Rate Range | Sample: 5–150 mL/min |
| Rinse | 5–500 mL/min |
| Fluid Temperature Range | 0–80 °C |
| Ambient Operating Range | −15–50 °C |
| Compliance | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 11171, GB/T 11446.9–2013, YBB00272004–2015, GB 8368 |
| Software | V8.9 Analytical Suite (PC & embedded touchscreen), FDA 21 CFR Part 11 compliant (audit trail, electronic signature, role-based 5-level access, data backup/restore, power-fail recovery) |
| Calibration Standards | NIST-traceable polystyrene latex (PSL) spheres, JJG 1061–2019, ISO 21501-4 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLD-601 |
| Price | USD 26,500 (FOB) |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Particle Size Range | 1–500 µm (optional 0.03–3000 µm) |
| Channel Count | 1000 customizable channels (down to 0.01 µm resolution) |
| Flow Accuracy | < ±1% |
| Volumetric Precision | < ±3% (typical) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (CP 2015/2020 calibration), <10% (USP/ISO 21501 calibration) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Fluid Temperature Range | 0–80 °C |
| Ambient Operating Temperature | −15–50 °C |
| Compliance | CP 2020 Method 0903, GB 8368, USP <788>, <789>, <797>, EP 10.0, BP 2019, JP 17, ISO 21501-2, ISO 11171, ASTM D6786, FDA 21 CFR Part 11 (audit trail, e-signature, role-based 5-level access) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PLD-601 |
| Price | USD 29,500 (approx.) |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Particle Sensing |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Control System |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-Traceable Latex Spheres |
| Regulatory Compliance | ChP 2020 <0903>, USP <788>/<789>, EP 10.0, BP 2019, JP 17, WHO IntPh IV, YBB00272004-2015, GB/T 11446.9-2013, ISO 21510, ISO 11171 |
| Software | V8.9 Regulatory-Grade Analysis Suite (FDA 21 CFR Part 11 Compliant) |
| Particle Size Range | 1–500 µm (optional extended range: 0.03–3000 µm) |
| Channel Resolution | 1000-user-definable channels (min. bin width: 0.01 µm) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Temperature Range (Fluid) | 0–80 °C |
| Accuracy | ±3% typical (per ChP 2020) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), >90% (ISO 21501-4 calibrated) |
| Data Integrity | Audit Trail, Electronic Signature, Role-Based 5-Tier User Permissions, Auto-Backup/Restore, Power-Fail Recovery |
| Interface | Color LCD Touchscreen + Optional Wireless Keyboard/Mouse |
| Sample Compatibility | Aqueous & non-aqueous sterile injectables, lyophilized powders, ophthalmic solutions, vaccines, WFI, pharmaceutical packaging materials, infusion devices, terminal filters, CMP slurries, ultrapure water, electronic-grade chemicals |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLD-601 |
| Price | USD 32,500 (FOB) |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Particle Sensing |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Regulation |
| Software | V8.9 Regulatory-Compliant Analysis Suite (PC & Touchscreen) |
| Calibration Standards | JJG1061, ISO 21501-4, NIST-Traceable Latex Spheres |
| Regulatory Alignment | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21510, GB/T 11446.9-2013, GB 8368 |
| Particle Size Range | 1–500 µm (optional extension: 0.03–3000 µm) |
| Channel Count | 1000 adjustable channels (user-definable from 4 to 128 size bins) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Temperature Range (Fluid) | 0–80 °C |
| Accuracy | ±3% typical (per ChP 2020) |
| Resolution | >95% (ChP-calibrated), >90% (ISO 21501-4 calibrated) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Sampling Precision | <±1% volumetric repeatability |
| Data Integrity | 5-Tier User Permission Architecture, Audit Trail, Electronic Signature, Full 21 CFR Part 11 Compliance, Auto-Backup/Restore, Power-Fail Recovery |