Pharmaceutical Testing Specialized Instruments
Filter
Showing 511–540 of 791 results
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601* |
| Sensor | 8th-generation dual-laser narrow-beam particle sensor |
| Detection Principle | Light Blockage (Optical Obstruction) |
| Measurement Range | 1–500 µm (optional 0.03–3000 µm) |
| Channel Count | 1000 adjustable channels (down to 0.01 µm resolution) |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Sample Temperature Range | 0–80 °C |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), <10% (USP/ISO 21501-calibrated) |
| Compliance | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 11171, GB/T 11446.9-2013, GB 8368, YBB 00272004-2015 |
| Software | V8.9 Regulatory Edition with 5-level user permissions, audit trail, electronic signature, 21 CFR Part 11 compliance, data backup/recovery, and power-fail protection |
| Interface | Touchscreen + optional wireless keyboard/mouse |
| Calibration Standards | JJG 1061, NIST-traceable latex spheres, or ISO 21501-4 reference materials |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601 |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Measurement Range | 1–500 µm (optional 0.03–3000 µm) |
| Channel Resolution | 1000 customizable channels (down to 0.01 µm bin width) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Temperature Range (Fluid) | 0–80 °C |
| Compliance | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-2, ISO 11171, GB/T 11446.9–2013, GB 8368, FDA 21 CFR Part 11 (audit trail, e-signature, role-based 5-level access), GLP/GMP-ready software architecture |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PLD-601 |
| Price | USD 34,500 (FOB Shanghai, ex-factory) |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Particle Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Control System |
| Software Compliance | FDA 21 CFR Part 11, ALCOA+ Data Integrity, Audit Trail, Electronic Signature, 5-Level User Permission Management |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-Traceable Latex Standards |
| Detection Range | 1–500 µm (optional 0.03–3000 µm) |
| Channel Count | 1000 High-Resolution Channels (0.01 µm resolution increment) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Temperature Range | Fluid 0–80 °C |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Repeatability | ≤2.5% coincidence error at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated) |
| Regulatory Alignment | ChP 2020 <0903>, USP <788>, <789>, <797>, EP 10.0, BP 2019, JP 17, WHO IntPh IV, YBB00272004-2015, GB/T 11446.9-2013, ISO 21510, ISO 4406, NAS 1638, ASTM D6786 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601 |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Particle Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Control System |
| Measurement Range | 1–500 µm (optional 0.03–3000 µm) |
| Resolution | >95% (ChP 2015/2020 calibrated) |
| Channel Count | 1000 user-definable channels (down to 0.01 µm bin resolution) |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Sample Temperature Range | 0–80 °C |
| Accuracy | ±3% typical (particle count), ±1% volumetric delivery |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Compliance | ChP 2020 <0903>, USP <788>, <789>, <797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, GB/T 11446.9–2013, GB 8368, YBB 00272004–2015, FDA 21 CFR Part 11 (audit trail, e-signature, role-based 5-level access, data backup/recovery, power-fail protection) |
| Software | PULUODY V8.9 PC & Integrated Touchscreen Edition |
| Interface | Bilingual (English/Chinese) GUI |
| Calibration Standards | NIST-traceable latex spheres, ISO 21501-4, JJG 1061 |
| Metrology Support | Accredited by NWMS (China National Institute of Metrology Northwest Center) & DFKW Level-1 Particle Metrology Station No. 116 |
| Key | Brand: PULUODY |
|---|---|
| Model | PLD-601 |
| Origin | Shaanxi, China |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Measurement Range | 1–450 µm (optional extension to 0.03–3000 µm) |
| Channel Count | 1000 adjustable size channels |
| Flow Rate (Sampling) | 5–150 mL/min |
| Flow Rate (Cleaning) | 5–500 mL/min |
| Accuracy | ±5% typical (per ChP 2020 & USP <788>) |
| Resolution | >95% (ChP-calibrated), <10% RSD (USP/ISO 21501-calibrated) |
| Sample Temperature Range | 0–80 °C |
| Environmental Operating Range | 0–50 °C |
| Compliance | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 11171, GB/T 11446.9-2013, YBB00272004-2015, GB 8368 |
| Software | V8.9 PC & Embedded Analysis Suite with 21 CFR Part 11 Compliance (Audit Trail, Electronic Signature, Role-Based 5-Tier Access, Data Backup/Restore, Power-Fail Recovery) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PLD-601 |
| Pricing | Upon Request |
| Sensor Technology | 8th-Generation Dual-Laser Narrow-Beam Particle Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Control System |
| Software | V8.9 Integrated Analysis Software (PC & Touchscreen) |
| Compliance | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10/9.0/8.0, BP 2019, JP 17, ISO 21501, ISO 11171, GB/T 11446.9–2013, YBB 00272004–2015, GB 8368 |
| Detection Range | 1–500 µm (optional 0.03–3000 µm) |
| Channel Count | 1000 user-definable channels (min. 4, max. 1000) |
| Resolution | >95% (ChP-calibrated), <10% (USP/ISO-calibrated) |
| Sampling Accuracy | <±1% |
| Measurement Accuracy | ±3% typical |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Fluid Temp. Range | 0–80 °C |
| Ambient Temp. Range | −15–50 °C |
| Calibration Standards | JJG 1061, ISO 21501, NIST-traceable latex spheres |
| Data Integrity | FDA 21 CFR Part 11 compliant (audit trail, electronic signature, role-based 5-level access, backup/restore, power-fail recovery) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLD-601 |
| Price | USD 23,500 (approx.) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China (Manufactured in China) |
| Manufacturer Type | Direct Manufacturer |
| Model | PLD-601-B |
| Price | USD 29,500 (approx.) |
| Detection Principle | Light Obscuration (LO) |
| Calibration Standards | USP <788>, USP <789>, EP 2.9.19, JP 6.04, ChP 2015 Vol I Appendix IX R |
| Measurement Range | 0.03 µm – 3000 µm (configurable sub-ranges) |
| Channel Count | 1000 adjustable size channels |
| Sample Volume | 1 mL to unlimited (programmable) |
| Flow Accuracy | ±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤3% at 40,000 particles/mL |
| Resolution | ≥95% (ChP 2015), <10% (USP <788>, ISO 21501-4, JJG 1061) |
| Viscosity Range | 0–99 mm²/s (pressurized up to 500 mm²/s) |
| Flow Rate | 5–150 mL/min (sampling), 5–500 mL/min (flushing) |
| Temperature Range | Fluid 0–80 °C |
| Data Storage | ≥20,000 test records (expandable via USB) |
| Compliance | FDA 21 CFR Part 11 ready (audit trail & electronic signature optional), GLP/GMP traceable operation |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PLD-MPCS2.0 |
| Price | USD 51,200 (FOB China) |
| Compliance | ChP 2020 Appendix 0903 Method 2 (Microscopic Particle Counting), USP <788>, USP <789>, EP 8.0, ISO 21501-4, ISO 21510, GB/T 11446.9-2013 |
| Measurement Principle | Bright-field Microscopy + Digital Image Analysis |
| Particle Detection Range | 1–500 µm |
| Magnification | 40×–1000× |
| Resolution | 0.1 µm |
| Repeatability Error | <5% (excluding sample preparation variability) |
| CCD Sensor | 3 MP monochrome digital camera |
| Calibration Traceability | Northwest Metrology & Testing Center (Civil Products) |
| Software Platform | Windows XP/7/10 (32/64-bit), RS232/USB interface |
| Image Processing Speed | <1 sec per frame segmentation |
| Segmentation Success Rate | >93% |
| Accuracy | ±3% typical (ChP 2020 reference), >95% resolution (ChP 2020), <10% misclassification rate (USP/ISO 21501-4) |
| Reporting | ASTM E2457-compliant output, GLP audit trail enabled, FDA 21 CFR Part 11 optional module available |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-MPCS2.0 |
| Magnification Range | 40×–1000× |
| Resolution | 0.1 µm |
| Measurement Range | 1–500 µm |
| Repeatability Error | <5% |
| Accuracy | ±3% (typical) |
| Particle Segmentation Speed | <1 s |
| Segmentation Success Rate | >93% |
| Brand | PULUODY |
|---|---|
| Model | PLD-MPCS2.0 |
| Origin | Shaanxi, China |
| Microscope Magnification | 40×–1000× |
| Measurement Range | 1–500 µm |
| Resolution | 0.1 µm |
| Repeatability Error | <5% |
| CCD Camera | 3 MP |
| Particle Segmentation Speed | <1 s |
| Segmentation Success Rate | >93% |
| Accuracy | ±3% (typical) |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Resolution Compliance | >95% (ChP 2020), <10% (USP <788>, ISO 21501) |
| Interface | RS232 or USB |
| Software Platform | Windows 2000/XP |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | PLD-MPCS2.0A |
| Price | USD 42,000 (approx.) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSD-351B |
| Gas Source | Nitrogen (optional) |
| Filtration Membrane Diameter | φ43 mm |
| Sample Volume Capacity | 3500 mL |
| Dimensions (W×D×H) | ≤500×500×800 mm |
| Compliance Standards | SY/T 5329–2012, GB 11901–1989, GB/T 606, GB/T 11133, GB 7600 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PSD-PF100-1A-0.5 |
| Dimensions | 360 × 450 × 580 mm |
| Cleanroom Class | ISO Class 4 (10-class) & ISO Class 5 (100-class) |
| Air Velocity | 0.25 m/s |
| Vibration Amplitude | ≤3 µm |
| Noise Level | ≤67 dB(A) |
| Lighting | Fluorescent Lamp |
| Sterilization | UV-C Lamp (254 nm) |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤75% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Construction | Powder-coated steel frame with 304 stainless steel work surface |
| Optional Accessories | High-purity nitrogen inlet with inline filter, articulated nitrogen delivery hose, motorized bidirectional sample rotation stage |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PSD-PF10A-0.5 |
| Cleanliness Class | ISO Class 4 (10 particles ≥0.1 µm per cubic foot) |
| Airflow Velocity | 0.25–0.6 m/s (adjustable) |
| Vibration Amplitude | ≤3 µm |
| Operating Noise | ≤67 dB(A) |
| UV Sterilization Time | 15 min for microbiological decontamination |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Ambient Temp. | 10–30 °C, RH ≤75%, low-vibration, low-dust environment |
| Construction | Fully welded steel frame with epoxy powder coating, 304 stainless steel work surface |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PST-890 |
| Price | USD 53,200 (approx. ¥380,000) |
| Sensor Generation | 8th-Gen Dual-Laser Narrow-Beam Detector |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-Traceable Latex Spheres |
| Software | V8.9 Integrated Particle Analysis Suite (PC & Embedded Touch UI) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Temperature Range (Fluid) | 0–80 °C |
| Environmental Operating Range | −15–50 °C |
| Counting Channels | 1000 configurable channels (user-definable from 4 to 128 size bins) |
| Detection Range | 1–450 µm (extended range 0.03–3000 µm optional) |
| Custom Ranges | 1–100 µm, 4–70 µm(c), 0.1 µm(c) |
| Sampling Accuracy | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Resolution | >95% (per ChP 2015/2020), <10% (per USP <788>, ISO 21501-4) |
| Compliance | GB/T 11446.9–2013, ChP 0903, USP <788>/<789>/<797>, EP 10.0/9.0/8.0, BP 2019/2018, JP 17/16/15, IP 2015, WHO IntPh IV, YBB 00272004–2015, GB 8368, ISO 21510, ISO 11171, NAS 1638, ISO 4406, SAE AS4059, MIL-STD-1246C, JIS B 9933, IP 564/565, ROC T 17216, GB/T 14039, DL/T 432, DL/T 1096, JB/T 9737, GJB/T 420A/B, GB/T 18854 |
| Brand | PULUODY |
|---|---|
| Model | PST-890 |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Particle Size Range | 1–450 µm (optional extended to 0.03–3000 µm) |
| Resolution | >95% (ChP 2015/2020 calibrated), <10% (USP/ISO 21501 calibrated) |
| Channel Count | 1000 adjustable channels (customizable from 4 to 128 size bins) |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow regulation |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Operating Temperature | Fluid 0–80 °C, Ambient –15–50 °C |
| Compliance | USP <788>, <789>, <797> |
| Brand | PULUODY |
|---|---|
| Model | PST-890 |
| Sensor Technology | 8th-Generation Dual-Laser Narrow-Beam Light Obscuration |
| Detection Range | 1–450 µm (optional 0.03–3000 µm) |
| Channel Count | 1000 adjustable channels (down to 4-channel user-defined bins) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), <10% (ISO 21501-calibrated) |
| Temperature Range (fluid) | 0–80 °C |
| Compliance | FDA 21 CFR Part 11, ASTM D6786, ISO 21501-4, ISO 11171, USP <788>/<789>, EP 10.0, ChP 0903, GB/T 11446.9-2013, YBB00272004-2015, GB 8368 |
| Software | V8.9 Regulatory-Compliant Particle Analysis Suite with Audit Trail, e-Signature, and 5-Tier User Permissions |
| Calibration Standards | NIST-traceable latex spheres, JJG 1061, or ISO 21501-4 reference materials |
| Sample Compatibility | Aqueous & non-aqueous parenterals, lipid emulsions, lyophilized powders (reconstituted), ophthalmic solutions, vaccines, WFI, medical packaging extracts, infusion sets, filter challenge fluids |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PST-890SIS |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Particle Size Range | 1–450 µm (optional extension to 0.03–3000 µm) |
| Channel Resolution | 1000 adjustable channels (down to 0.01 µm bin width) |
| Sampling Accuracy | < ±1% |
| Measurement Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Resolution Compliance | >95% per ChP 2015/2020 |
| Flow Rate (Sampling) | 5–150 mL/min |
| Flow Rate (Rinse) | 5–500 mL/min |
| Fluid Temperature Range | 0–80 °C |
| Ambient Operating Temperature | −15–50 °C |
| Software | V8.9 Integrated Analysis Suite with 21 CFR Part 11 Compliance |
| Regulatory Alignment | ChP 0903, USP <788>/<789>/<797>, EP 10.0/9.0, BP 2019, JP 17, ISO 21510, ISO 11171, NAS 1638, ASTM D6786, GB/T 11446.9–2013, YBB00272004–2015, GB 8368 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PST-890SIS |
| Sensor | 8th-Generation Dual-Laser Narrow-Beam Particle Sensor |
| Detection Range | 1–450 µm (optional 0.03–3000 µm) |
| Resolution | >95% (per ChP 2015/2020), <10% (per USP/ISO 21501) |
| Channel Count | 1000 adjustable channels (configurable from 4 to 128 size bins) |
| Sampling Flow Rate | 5–150 mL/min |
| Cleaning Flow Rate | 5–500 mL/min |
| Temperature Range (Fluid) | 0–80 °C |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Compliance | USP <788>, <789>, <797> |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PST-890SIS |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Particle Size Range | 1–450 µm (optional 0.03–3000 µm) |
| Channel Count | 1000 adjustable channels (down to 4-channel custom binning) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), <10% (USP/ISO 21501-calibrated) |
| Temperature Range (Fluid) | 0–80 °C |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready, Audit Trail, Electronic Signature, 5-Tier User Permission Architecture |
| Software | V8.9 Particle Analysis Suite (PC + embedded touchscreen) |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-traceable latex spheres |
| Regulatory Alignment | ChP 0903 (2015/2020), USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21510, ISO 11171, NAS 1638, ISO 4406 |
| Brand | PULUODY |
|---|---|
| Model | TQ-01A |
| Application | Pharmaceutical Dissolution Media Deaeration |
| Display | High-Resolution Touchscreen LCD |
| Heating Range | 35–42 °C (adjustable to non-heating mode) |
| Volume Accuracy | ±1% (for set volumes ≥2 L) |
| Dispensing Resolution | 0.1 L |
| Flow Rate | 1.6 L/min |
| Dimensions (L×H×W) | 500 mm × 340 mm × 295 mm |
| Rated Power | 1700 W |
| Temperature Control Accuracy | ±2 °C |
| Residual Dissolved Oxygen | 3.0–5.0 mg/L (upgradable to <2.8 mg/L) |
| Minimum Inlet Medium Temperature | ≥18 °C |
| Pre-Filter Options | 40 µm / 25 µm / 20 µm Stainless Steel Mesh |
| Compatible Media | Purified water, distilled water (pH 1–14, surfactant-free) |
| Brand | Qigao Instruments / SHqigao |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | SYD-2801 |
| Price | Upon Request |
| Penetration Range | 0–700 dmm |
| Minimum Readout | 0.1 dmm |
| Resolution | 0.01 mm |
| Penetration Accuracy | ±1 dmm |
| Temperature Range | 5.0–100.0 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Bath Volume | 5.5 L |
| Circulation Flow Rate | 5 L/min |
| Pump Head | 1 m |
| Power Supply | AC (220 ± 10%) V, 50 Hz |
| Power Consumption | ≤1800 W |
| Dimensions (L×W×H) | 520 × 330 × 600 mm |
| Brand | Quadro |
|---|---|
| Origin | Canada |
| Model | U5 Comil |
| Motor | 0.55 kW (3/4 HP) |
| Max Speed | 6500 rpm |
| Throughput | 50 g/hr – 150+ kg/hr |
| PSD (D50) | 150–300 µm |
| PSD (D90) | 300–2000+ µm |
| Design | Gapless conical mill architecture |
| Operation Modes | Dry and wet milling, granulation sizing, deagglomeration |
| Compliance | Designed for GMP-compliant pharmaceutical manufacturing environments |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Radioisotope Source Capsule Automatic Inspection System |
| Pricing | Available Upon Request |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | RB-I |
| Pricing | Available Upon Request |
| Tube Height | 60 mm |
| Tube Inner Diameter | 52 mm |
| Timer Range | 10–120 min |
| Temperature Control Accuracy | 37.0 ± 0.5 °C |
| Mesh Disk Dimensions | 50 mm diameter, 39 apertures of 4 mm each |
| Flip Frequency | 1 cycle per 10 min |
| Test Stations | 3 independent tube–mesh assemblies |
| Beaker Capacity | 4 L |
| Power Rating | 1000 W |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | RC-6 |
| Price | USD 2,400 (FOB Tianjin) |
| Speed Range | 20–200 rpm |
| Speed Accuracy | ±2 rpm |
| Temperature Control Range | Ambient to 39.9°C |
| Temperature Accuracy | ±0.3°C |
| Timer Range | 0–999 minutes per station (6 stations) |
| Basket Wobble | ≤1 mm |
| Paddle Shaft Wobble | ≤0.05 mm |
| Power Supply | 220 V AC, 50 Hz, 1000 W |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | RC-8D |
| Pricing | Available Upon Request |
| Speed Range | 20–200 rpm |
| Speed Accuracy | ±2 rpm |
| Temperature Control Range | Ambient to 39.9 °C |
| Temperature Accuracy | ±0.3 °C |
| Timing Range | 0–999 min (6 programmable time points) |
| Basket Wobble Tolerance | ±1 mm |
| Paddle Shaft Runout | ±0.5 mm |
| Power Supply | 220 V / 50 Hz / 1000 W |
| Dimensions (W×D×H) | 960 × 520 × 480 mm |
| Construction Materials | SUS316L stainless steel (baskets, paddles, shafts), magnetically driven recirculating water bath system |
| Automation Features | Motorized head lift, dual-zone cup configuration (6 test cups + 2 auxiliary reservoir cups), real-time parameter display, stored USP/ChP dissolution methods, auto-diagnostic alerts, programmable multi-stage timing with audible notification |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | RC-8DS |
| Pricing | Available Upon Request |
| Stirring Speed Range | 20–200 rpm |
| Speed Accuracy | ±2 rpm |
| Temperature Control Range | Ambient to 39.9 °C |
| Temperature Accuracy | ±0.3 °C |
| Timer Range | 0–999 min (6 programmable time points) |
| Basket Wobble Tolerance | ±1 mm |
| Paddle Wobble Tolerance | ±0.5 mm |
| Power Supply | 220 V / 50 Hz / 1000 W |
| Dimensions (W×D×H) | 680 × 540 × 480 mm |
| Construction Material | Imported SUS316L stainless steel for baskets, paddles, and shafts |
| Fluid Circulation System | Magnetic-drive water pump with uniform thermal distribution |
| Control Mode | Intelligent microprocessor-based PID control for temperature, rotation speed, and timing |
| Automation Features | Motorized head lift/lower mechanism, auto-diagnostic self-check, real-time parameter display (set vs. actual), programmable multi-point timed sampling alerts, USP-compliant dissolution method storage |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | RCZ-1A |
| Price | USD 600 (FOB Shanghai) |
| Temperature Control Accuracy | ±0.5 °C at 37 °C |
| Rotational Speed Options | 50, 100, 150, 200 rpm |
| Shaft Coaxiality Tolerance | <1 mm |