Physical Property Testing Instruments
Filter
Showing 2491–2520 of 12279 results
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | PTC-TPV |
| Sampling Rate | 60 MS/s |
| Time Resolution | 18 ns |
| Frequency Range | 10 mHz – 10 MHz |
| Current Resolution | < 100 pA |
| LED Rise Time | 100 ns |
| Current Range | ±100 mA |
| Voltage Range | ±12 V |
| Optional Modules | Solar Cell & OLED Dual Configuration, Multi-Wavelength LED Source (360–1100 nm), Cryogenic/Heated Stage (−120 °C to +150 °C), Integrated Spectrometer, SMU Extension (±60 V, 1 pA current resolution) |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | TEL |
| Key Features | DC/AC/Transient operation modes |
| Measurement Capabilities | TEL, TPC, TPV, Photo-CELIV, Dark-CELIV, IMPS, IMVS, IS, CV, C-f, DLTS, SCLC, Pulse Voltage, MIS-CELIV, Delaytime-CELIV, Injection-CELIV |
| Sampling Rate | 60 MS/s |
| Time Resolution | 18 ns |
| Frequency Range | 10 mHz – 10 MHz |
| Current Resolution | <100 pA |
| LED Rise Time | 100 ns |
| Current Range | ±100 mA |
| Voltage Range | ±12 V (extendable to ±60 V with SMU module) |
| Spectral Coverage (Multi-LED) | 360–1100 nm |
| Temperature Range (optional cryo/heating stage) | −120 °C to +150 °C |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | TPC/TPV |
| Sampling Rate | 60 MS/s |
| Time Resolution | 18 ns |
| Frequency Range | 10 mHz – 10 MHz |
| Current Resolution | <100 pA |
| LED Rise Time | 100 ns |
| Current Range | ±100 mA |
| Voltage Range | ±12 V (optional ±60 V with SMU module) |
| Spectral Coverage (Multi-LED) | 360–1100 nm |
| Temperature Range (optional cryo/heating stage) | −120 °C to +150 °C |
| Brand | Changchun Intelligent |
|---|---|
| Origin | Jilin, China |
| Model | PZY-200 |
| Cutting Display Resolution | 0.01 mm |
| Dimensional Accuracy | ±1 mm |
| Worktable Dimensions | 1000 × 700 mm |
| Effective Travel of Movable Worktable | 500 mm |
| Power Supply | 380 V AC |
| Rated Power | 2.2 kW |
| Specimen Size | 25 × 25 × 10 mm |
| Brand | Force |
|---|---|
| Origin | Denmark |
| Model | ERE 20 |
| Type | Embedded Half-Cell Reference Electrode |
| Electrode Material | Manganese Dioxide (MnO₂) |
| Electrolyte pH | ~13.5 |
| Housing | Stainless Steel (AISI 316) |
| Ionic Membrane | Cementitious Mortar |
| Input Impedance Requirement | >100 MΩ |
| Compliance | EN 12696:2016, ASTM C876, ISO 15663-2 |
| Installation | Embeddable in Fresh or Existing Concrete |
| Output Interface | Standard BNC or Screw-Terminal Voltage Output |
| Operating Temperature Range | −10 °C to +60 °C |
| Long-Term Drift | < ±2 mV/year (typical, under stable alkaline conditions) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Models | Ford Cup No. 2, No. 3, No. 4 |
| Orifice Diameter | 2.54 mm (No. 2), 3.30 mm (No. 3), 3.81 mm (No. 4) |
| Cup Volume | 100 ± 1 mL |
| Kinematic Viscosity Range | 25–120 cSt (No. 2), 40–220 cSt (No. 3), 70–370 cSt (No. 4) |
| Temperature Control Requirement | 23 ± 0.5 °C (or agreed-upon test temperature) |
| Compliance | ASTM D1200, D333, D365, D4212 |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Formastor-F |
| Price | USD 280,000 (FOB Japan) |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | FLUIDICAM |
| Viscosity Range | 0.1–200,000 cP |
| Shear Rate Range | 100–1.8×10⁵ s⁻¹ |
| Temperature Control Range | 4–80 °C |
| Compliance | Designed for GLP/GMP-relevant workflows with audit-trail-capable software logging |
| Brand | Formulaction (Microtrac Group) |
|---|---|
| Origin | France |
| Model | RHEOLASER MASTER |
| Light Source | 650 nm laser |
| Detection Principle | Multi-Speckle Diffusing Wave Spectroscopy (MS-DWS) |
| Detection Mode | Backscattered light |
| Detector | Dedicated CCD camera |
| Sample Cell | 20 mL standard glass vial (optional 4 mL) |
| Sample Capacity | 6-position automated sample tray |
| Temperature Control Range | +5 °C to 90 °C above ambient (optional up to 150 °C) |
| Temperature Stability | ±0.1 °C |
| Frequency Range (Viscoelastic Spectrum) | 10⁻⁴ Hz to 50 Hz (sample-dependent) |
| Measured Particle RMS Displacement Range | 0.1 nm – 100 nm |
| Compliance | Designed for GLP/GMP environments |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | Rheolaser Master |
| Instrument Type | Optical Microrheometer |
| Sample State | Liquid |
| Measurement Principle | Multi-Speckle Diffusing Wave Spectroscopy (MS-DWS) |
| Temperature Range | +5°C above ambient to 90°C (optional up to 150°C) |
| Frequency Range | 10⁻⁴ Hz to 10² Hz |
| RMS Particle Displacement Range | 0.1 nm – 100 nm |
| Minimum Detectable Particle Size | 50 nm |
| Maximum Solid Volume Concentration | 90% v/v |
| Torque Specifications | Not applicable (non-mechanical, optical measurement) |
| Data Acquisition | High-resolution CMOS camera-based speckle image analysis |
| Sample Holder | 20 mL borosilicate glass cuvette with 6-position sample carousel |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | Turbiscan AGS |
| Particle Size Range | 0.05–1000 µm |
| Concentration Range | up to 95% v/v |
| Temperature Control | 25–60 °C (±0.5 °C) |
| Sample Capacity | 54 positions (3 × 18-well thermostated modules) |
| Scan Resolution | 40 µm along 55 mm height |
| Scan Interval | as low as 20 s per scan |
| Light Source | Pulsed NIR LED (880 nm) |
| Detectors | Synchronized transmission and backscattering photodiodes |
| Compliance | ASTM D7809, ISO 13321, USP <729>, GLP-ready data audit trail |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | TURBISCAN LAB |
| Measurement Principle | Static Multiple Light Scattering (MLS) |
| Wavelength | 880 nm (pulsed NIR source) |
| Scan Height | 55 mm |
| Spatial Resolution | 20 µm |
| Temp. Range | +5 °C above ambient to 60 °C |
| Temp. Control Accuracy | ±0.5 °C |
| Particle Size Range | 0.01–1000 µm |
| Max. Concentration | 95% v/v |
| Detectors | Dual photodiode (transmission + backscattering) |
| Sample Cell | Cylindrical glass cell (Ø 27.5 mm × H 55 mm), threaded black cap with butyl/PTFE seal |
| Data Acquisition Modes | Full-height scanning (1 scan/20 s) or fixed-position kinetics (1 measurement/s) |
| Max. Scan Programs | 250 |
| Software Output | BS/T vs. time, layer thickness vs. time, particle migration velocity, hydrodynamic diameter (d), volume fraction (φ), mean free path, TSI Stability Index, dispersion index |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | TMIX |
| Light Source | 880 nm NIR LED |
| Measurement Principle | Multiple Light Scattering (MLS) |
| Particle Size Range | 0.05–1000 µm |
| Max. Volume Concentration | 95% v/v |
| Temperature Control Range | RT + 5 °C to 60 °C |
| Scan Height | 55 mm |
| Spatial Resolution | 40 µm |
| Dimensions (W × D × H) | 38 × 42 × 32 cm |
| Sample Capacity | 1 tube per run |
| Data Acquisition Interval | 20 s |
| Compliance | Designed for GLP-compliant stability assessment |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | TURBISCAN TOWER |
| Detection Principle | Multiple Light Scattering (MLS) |
| Wavelength | 880 nm (pulsed NIR source) |
| Sample Capacity | 6 positions |
| Temperature Range | 4–80 °C |
| Temp. Control Accuracy | ±0.1 °C |
| Scan Height | 55 mm |
| Spatial Resolution | 20 µm per data point |
| Scan Interval | ≥20 s (user-configurable) |
| Particle Size Range | 0.01–1000 µm |
| Max. Concentration | 95% v/v |
| Measurement Modes | Transmission (T) and Backscattering (BS) |
| Software Compliance | FDA 21 CFR Part 11 ready, audit trail enabled, GLP/GMP-supportive workflows |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | TURBISCAN TRI-LAB |
| Light Source | 880 nm NIR LED |
| Sample Volume | 1.5–30 mL |
| Temperature Range | 20–60 °C |
| Sample Capacity | 1–3 positions |
| Concentration Range | 0.0001–95% v/v |
| Measurement Principle | Static Multiple Light Scattering (SMLS) |
| Detection Modes | Simultaneous Transmitted (T) and Backscattered (BS) Light |
| Output Metrics | Turbiscan Stability Index (TSI), Migration Rate, Phase Thickness, Kinetic Index, Mean Hydrodynamic Diameter, Dispersion Ratio, Redispersion Efficiency |
| Brand | FoShan TST |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ARC Series |
| Pricing | Available Upon Request |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (approx.) |
| Temperature Range | RT+100°C to 125°C |
| Humidity Range | 75–100% RH (saturated steam) |
| Temperature Uniformity | ±0.5°C |
| Temperature Stability | ±0.5°C |
| Humidity Stability | ±1% RH |
| Temperature Resolution | 0.1°C |
| Pressure Range | 0–2.5 kg/cm² (design burst pressure: 3.5 kg/cm²) |
| Pressure Fluctuation | ±0.02 kg/cm² |
| Pressurization Time | ≤45 min (to 1.04 kg/cm²) |
| Test Condition Reference | 121°C / 100% RH / 1.04 kg/cm² |
| Internal Chamber Dimensions | Φ240 mm × 440 mm (D) |
| Timer Range | 000–999 hours |
| Control System | Microprocessor-based controller with LED display |
| Heating/Cooling Medium | R404A refrigerant |
| Compressor | Tecumseh/Taikang hermetic scroll compressor |
| Noise Level | <60 dB(A) |
| Water Supply | Automatic tap-water filtration and replenishment system |
| Steam Generation | Distilled water recovery and reuse |
| Compliance | GB/T 2423.1–1989, GB/T 2423.2–1989, GB/T 2423.3–1993 |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YL-1209 |
| Price Range | USD 1,400–7,200 (based on configuration) |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity Options | 10 N, 20 N, 50 N, 100 N, 200 N, 500 N, 1 kN, 2 kN, 5 kN (dual-range configuration available) |
| Force Resolution | 1/500,000 full scale |
| Force Accuracy | ±0.3% of reading |
| Travel Resolution | 0.005 mm |
| Crosshead Speed Range | 0.5–500 mm/min (software-controlled) |
| Maximum Travel | 350 mm |
| Test Width | 420 mm |
| Control Interface | PC-based with USB connectivity |
| Data Acquisition | Real-time force/displacement sampling with curve plotting |
| Compliance Standards | ISO 7500-1, ASTM E4, DIN 51221, JIS B7721/B7733, EN 10002-1, GB/T 228.1, JJG 475 |
| Brand | YUELIAN / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PW-6603 |
| Pricing | Available Upon Request |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | AVI800Z |
| Quotation | Upon Request |
| Laser Wavelength | 355 nm |
| Max. Average Laser Power | 15 W |
| Laser Repetition Rate | 40–120 kHz |
| Max. Processing Area | 200 mm × 270 mm |
| Overall Processing Accuracy (Zhengye Standard Conditions) | ±50 µm |
| Motor Speed | 500 mm/s |
| Motor Positioning Accuracy | ±4 µm |
| Motor Repeatability | ±2 µm |
| Laser Scanning Range | 40 mm × 40 mm |
| Host Power Supply | AC 220 V, 50 Hz / 1.5 kW |
| Dust Collector Power Supply | AC 380 V, 50 Hz / 1.5 kW |
| Weight | 1500 kg |
| Operating Temperature | 20 °C ± 2 °C |
| Relative Humidity | ≤60 % RH |
| Supported File Formats | .Gbr, .dxf |
| Dimensions (L×W×H) | 1100 mm × 1570 mm × 1700 mm |
| Cleanroom Classification | ISO Class 8 (100,000) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FPT-30A |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FQY010 / FQY030 |
| Quotation | Available Upon Request |
| Temperature Range | Ambient to 55 °C |
| Temperature Fluctuation | ≤ ±0.5 °C |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Deviation | ≤ ±2 °C |
| Salt Solution Deposition Rate | 1–2 mL per 80 cm²·h |
| Internal Chamber Volume | 0.1 m³ (FQY010) / 0.3 m³ (FQY030) |
| Internal Dimensions (D×W×H) | 460×590×400 mm (FQY010) / 640×1000×500 mm (FQY030) |
| Heating Power (Excl. Compressor) | 1.2 kW / ≤3 kW |
| Gross Weight | ~175 kg / ~300 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FQY010A |
| Quotation | Available upon Request |
| Temperature Range | Ambient to 50 °C |
| Temperature Fluctuation | ≤ ±0.5 °C |
| Temperature Uniformity | ≤ 2 °C |
| Temperature Deviation | ≤ ±2 °C |
| Salt Spray Deposition Rate | 1–2 mL per 80 cm² per hour |
| Internal Chamber Volume | 0.1 m³ |
| Internal Dimensions (D×W×H) | 500 × 500 × 400 mm |
| External Dimensions (D×W×H) | 720 × 1010 × 1080 mm |
| Total Power Consumption (excl. compressor) | 1.2 kW |
| Net Weight | Approx. 175 kg |
| Compliance | GB/T 2423.17, ISO 9227 |
| Origin | Greece |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FR-pOrtable |
| Pricing | Upon Request |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Polynorme 506 |
| Price | Upon Request |
| Standard Compliance | NFP 92-506 |
| Radiation Panel Dimensions | 305 mm × 305 mm × 70 mm porous ceramic |
| Metal Frame Dimensions | 320 mm × 320 mm |
| Ignition Flame Height | ~40 mm |
| Ignition Burner | 3 mm diameter copper tube |
| Preheat Time to 850 °C | 5–10 min |
| Thermometric Monitoring | High-temperature radiometer + 25 mm Ø × 0.2 mm thick copper disc sensor |
| Brand | FRITSCH |
|---|---|
| Origin | Germany |
| Model | ANALYSETTE 18 |
| Voltage | 230 V, 1~ |
| Frequency | 50–60 Hz |
| Input Power | 480 W |
| Sieving Method | Dry Sieving |
| Sample Condition | Dry |
| Sieving Range (Dry) | 20 µm – 125 mm |
| Max. Sample Load | 6 kg |
| Sieving Time | 5–60 min |
| Dimensions (W×L×H) | 58 × 58 × 39 cm |
| Net Weight | 92 kg |
| Gross Weight | 129 kg |
| Motor Type | Two maintenance-free asymmetric motors |
| Motion Type | Simultaneous horizontal and vertical oscillation |
| Compliance | ISO 3310-1, ASTM E11-95, ISO 9000 traceable calibration |
| Brand | FRITSCH |
|---|---|
| Origin | Germany |
| Model | Analysette 18 |
| Measurement Principle | Dry Mechanical Vibratory Sieving |
| Max. Sample Capacity | 15 kg (standard), up to 25 kg with optional large-diameter sieve stack |
| Sieve Aperture Range | 20 µm – 125 mm |
| Max. Sieve Diameter | 450 mm (18") |
| Sieving Time | 5–60 min |
| Drive System | Dual Asymmetric Counter-Rotating Motors |
| Compliance | ISO 2591-1, ISO 9276-1, ASTM E11, USP <786> |
| Software | AUTOSIEVE v5.x (FDA 21 CFR Part 11 compliant audit trail & user access control) |
| Brand | Fritsch |
|---|---|
| Origin | Germany |
| Model | ANALYSETTE 22 Micro Tec Plus |
| Measurement Range | 0.08–2000 µm |
| Laser Sources | Dual-laser system (green: λ = 532 nm, 7 mW |
| IR | λ = 940 nm, 9 mW), Class 1 safety certified per EN 60825-1 |
| Optical Design | Inverse Fourier configuration with motorized sample cell positioning |
| Detector Array | 57-channel dual-axis (vertical & horizontal polarization) sensor |
| Dispersion Options | Modular dry and wet dispersion units (optional) |
| Compliance | ISO 13320 compliant |
| SOP Architecture | Modular, parameter-independent workflow design |
| Cleaning | Automated rinse cycle |
| Environmental Rating | Dry dispersion compatible with ISO Class 5 (Grade A) cleanroom environments |
| Software | Fully configurable reporting, background subtraction algorithm, tap-water-compatible measurement protocol |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Micro Tec² |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Micro Tec² |
| Pricing | Upon Request |