Physical Property Testing Instruments
Filter
Showing 2461–2490 of 12279 results
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | MMS PC2 |
| Operating System | Windows CE |
| Connectivity | LAN, USB |
| Measurement Principles | Eddy Current (amplitude & phase-sensitive), Magnetic Induction, Beta Backscatter, X-ray Fluorescence (via optional modules) |
| Supported Properties | Coating thickness (non-conductive on non-ferrous, non-conductive on ferrous, conductive on non-ferrous), Ferrite content in austenitic steels, Electrical conductivity of non-ferrous metals |
| Compliance | ISO 2178, ISO 2360, ASTM B244, ASTM B536, DIN 50981, DIN 50982, EN ISO 2178, EN ISO 2360 |
| Data Management | Onboard storage, CSV export, GLP-compliant audit trail (via software), FDA 21 CFR Part 11 ready (with validated software package) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FISCHERSCOPE PMP10 |
| Pricing | Available Upon Request |
| Measurement Principle | Micro-Resistance (4-Point Probe) |
| Thickness Range | 0–120 µm |
| Accuracy | ±0.5 µm (5–50 µm), ≤1% of reading (50–80 µm), ≤2% of reading (>80 µm) |
| Test Area | 10 × 15 mm |
| Compliance | ISO 2178, ASTM B499, IPC-4552A, RoHS-compliant design |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ADLM-PCB |
| Pricing | Available Upon Request |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XDL |
| Measurement Principle | Energy-Dispersive X-ray Fluorescence (ED-XRF) |
| Elemental Range | Cl (Z=17) to U (Z=92) |
| Sample Positioning Options | Fixed or Motorized X/Y/Z Stages (XDL 210–240 variants) |
| Collimator Options | Circular or Rectangular |
| Detector Type | Proportional Counter |
| Measurement Distance | 0–80 mm |
| DCM Technology | Patented Distance Compensation Method |
| Camera System | High-Resolution CCD Color Imaging |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Weight | 100–120 kg |
| Compliance | Designed for ISO 3497, ASTM B568, DIN 50987, and EN ISO 3497-compliant measurement workflows |
| Software | FISCHER WinFTM® v8+ with GLP/GMP audit trail, 21 CFR Part 11 optional modules |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XDLM |
| Measurement Principle | Energy-Dispersive X-ray Fluorescence (EDXRF) |
| Sample Positioning | Motorized Z-axis (standard) |
| Collimators | 4 interchangeable (diameters: 0.1, 0.2, 0.3, 0.5 mm) |
| Primary Filters | 3 interchangeable Al, Cu, Ti |
| Detector | Proportional counter with high-count-rate capability |
| Measurement Distance | 0–80 mm (adjustable via motorized Z-axis) |
| Optical Alignment | Integrated high-resolution color CCD camera with 10× digital zoom |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Instrument Weight | 100–120 kg |
| PC Interface | PCI/PCIe expansion slot required for spectrometer control and data acquisition |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XDLM-PCB 220 |
| X-ray Tube | Tungsten anode microfocus tube with beryllium window |
| Tube Voltage | 3 adjustable high-voltage settings (up to 50 kV) |
| Detector | Proportional counter detector |
| Collimators | Motorized, multiple interchangeable apertures |
| Primary Filters | 3 motorized basic filters |
| Sample Stage | Motorized XYZ stage with programmable XY positioning and pop-up function |
| Optical Alignment | High-resolution color camera + laser pointer for precise targeting |
| Measurement Geometry | Horizontal sample chamber with bottom-access gap for large PCBs |
| Analysis Method | Fundamental Parameters (FP) quantification without calibration standards |
| Compliance | Designed for ISO 3497, ASTM B568, IPC-4552A, and RoHS/WEEE screening workflows |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X-RAY |
| Pricing | Available Upon Request |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XUL220 |
| Measurement Principle | Energy-Dispersive X-Ray Fluorescence (ED-XRF) |
| Detector Type | Proportional Counter |
| Count Rate Capability | High |
| Imaging System | High-Resolution Color CCD Camera with Manual Focus and Adjustable LED Illumination |
| Sample Chamber Dimensions | Extra-Large (Enabling Large-Part Measurement) |
| Stage | Manual XY Translation Stage |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤95% RH (Non-Condensing) |
| Compliance | Designed for ISO 3497, ASTM B568, DIN 50982, and RoHS/WEEE Screening Applications |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XULM |
| Detector Type | Proportional Counter |
| Optical System | High-Resolution CCD Color Camera with Manual Focus |
| Collimators | 4 Switchable (e.g., 0.1 mm, 0.2 mm, 0.3 mm, 0.5 mm) |
| Primary Filters | 3 Switchable |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Form Factor | Benchtop with Manual XY Stage |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XDVM-W |
| Measurement Principle | X-ray fluorescence (XRF) |
| Standards Compliance | DIN 50987, ISO 3497, ASTM B568 |
| Cabinet Dimensions (H×W×D) | 720 × 660 × 950 mm |
| Weight | ~135 kg |
| Internal Chamber (H×W×D) | 160 × 560 × 530 mm |
| X-ray Tube | Adjustable high voltage (30/40/50 kV), current up to 0.8 mA |
| Detector | Xenon-filled proportional counter with 4096-channel ADC (displayed as 256-channel spectrum) |
| Collimator Options | Standard Set I (0.1 mm, 0.2 mm, 0.05×0.05 mm², 0.03×0.2 mm² slot), optional Sets II & III |
| XY Stage Travel | 250 × 250 mm (XDVM-W standard configuration) |
| Z-axis Travel | 145 mm |
| Camera | High-resolution color CCD with dual magnification (×40 / ×80), crosshair + metric grid + spot size indicator |
| Software Platform | Native Win32 application for Windows 2000 and later |
| Language Support | English, German, French, Italian, Spanish, Chinese, Japanese |
| Data Interface | RS-232 serial port, remote command control via script files or network environment |
| Calibration | Automated beam centering, “Application Toolbox” with calibration standards and parameter disk |
| Reporting | User-defined report editor with embedded images (BMP), company logos, charts, font selection |
| Statistical Tools | SPC charts, probability plots, histogram analysis |
| Security | Customizable “short menu” lockout for critical system functions |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | HM2000_S |
| Compliance | DIN EN ISO 14577 |
| Measurement Principle | Instrumented Indentation Testing (IIT) |
| Output Parameters | Martens Hardness (HM), Indentation Hardness (HIT), Indentation Modulus (EIT), Indentation Creep (CIT), Elastic Work Ratio (ηIT = Welast/Wtotal) |
| Enhanced Stiffness Procedure (ESP) | Yes |
| Load Range | Sub-mN to 1 N (typical for micro/nano-scale IIT systems) |
| Depth Resolution | < 0.1 nm |
| Load Resolution | < 1 µN |
| Sample Height Max | ~100 mm |
| XY Stage Travel | 100 × 100 mm (motorized, optional) |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XDV-SDD |
| Detector Type | Silicon Drift Detector (SDD) |
| Excitation Source | Micro-focus Tungsten X-ray Tube with Beryllium Window |
| Adjustable Tube Voltage | 3 kV / 15 kV / 50 kV |
| Filter Options | 6 interchangeable primary filters |
| Collimators | Motorized, switchable |
| Elemental Range | Al (13) to U (92), up to 24 elements simultaneously quantifiable |
| Sample Stage | Motorized, programmable X/Y translation stage + motorized Z-axis lift |
| Safety | Interlocked top-hinged measurement door with automatic sample-stage egress |
| Imaging System | Integrated high-resolution video camera with 10× digital zoom, crosshair overlay, and real-time positioning feedback |
| Software Platform | WinFTM® v8.x (compliant with ISO 3497, ASTM B568, DIN 50981, and EN ISO 3497 for coating thickness measurement) |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XDV-μ |
| Excitation Optics | Polycapillary X-ray Lens System |
| Detector | Silicon Drift Detector (SDD) |
| Elemental Range | Al (13) to U (92) |
| Max. Simultaneous Elements | 24 |
| Sample Stage | Motorized X/Y Table + Motorized Z-axis Lift |
| Filtration | 4 Switchable Primary Filters |
| High Voltage | 3 Adjustable kV Settings |
| Software | WinFTM® |
| Compliance | ISO 3497, ASTM B568, DIN EN ISO 3497, RoHS/WEEE Directive Support |
| Optional Accessories | Large-area PCB Stage, Custom Collimators |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XDVM-u |
| Measurement Principle | X-ray Fluorescence (XRF) |
| Compliance | DIN 50987, ISO 3497, ASTM B568 |
| Max. Measurable Layers | 23 |
| Elements Analyzed | Cl (Z=17) to U (Z=92) |
| Element Quantification Range | x ppm to 100% |
| Spectral Channels | 1024 (raw: 4096) |
| Minimum Spot Size | 50 × 100 µm |
| Focal Depth Range | 2.5 mm |
| X-ray Tube | Adjustable HV (30/40/50 kV), Current up to 0.8 mA |
| Detector | Peltier-cooled semiconductor with high energy resolution |
| XY Stage Travel | X=250 mm, Y=220 mm, Positioning Accuracy: ±0.005 mm |
| Z-Axis Travel | 95 mm |
| Camera Magnification | 30×–1108× with crosshair & scale grid |
| Software | WinFTM® V6 with PDM (Product Data Management) |
| Interface | RS232, Ethernet, removable storage |
| Languages | English, German, French, Italian, Spanish, Chinese |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | Aode305-11231 |
| Product Type | Intelligent |
| Display Interface | PC-based Software |
| Measurement Range | 0.20–50 µm |
| Repeatability | ±3% |
| Porosity Range | 0.25–0.95 |
| Inlet Gas Pressure | 3 kPa |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | Polynorme 503 |
| Applicable Standard | NF P 92-504 |
| Test Principle | Vertical flame impingement using calibrated gas burner |
| Sample Holder | Dual U-shaped fixtures for rigid and flexible materials |
| Compliance | French building material fire reaction classification (M0–M4), rail industry non-metallic component qualification |
| Brand | FlowCam |
|---|---|
| Origin | Japan |
| Model | FlowCam 5000 |
| Particle Size Range | 3–300 µm |
| Camera Resolution | 1920 × 1200 pixels (color CMOS) |
| Frame Rate | up to 100 fps |
| Optical Configurations | 4X (300 µm depth), 10X (100 µm depth), 20X (50 µm depth) |
| Sample Flow Rate | 0.05–2 mL/min |
| Max Particle Concentration | 4 × 10⁶ particles/mL (at 3 µm) |
| Dimensions | 44 × 25 × 27 cm |
| Weight | 10 kg (operational), 24 kg (shipping) |
| Power Consumption | ≤92 W |
| Brand | FLOXLAB |
|---|---|
| Origin | France |
| Model | AUTOMATED SPECIMEN CORING MACHINE |
| Core Diameter Range | 21.5–150 mm (0.845–6.0 in) |
| Max Core Depth | 300 mm (12 in) |
| Fluid Tray Dimensions | 1340 × 380 × 340 mm |
| Core Orientation Range | −45° to +45° |
| Fluid Tray Travel | X: ±1000 mm, Y: ±125 mm |
| Cooling Options | Water, Oil, Liquid Nitrogen |
| Spindle Speeds | 550 / 1120 / 1680 rpm |
| Overall Dimensions (L×W×H) | 1700 × 680 × 2140 mm |
| Weight | 300 kg |
| Operating Water Pressure | 100 psi |
| Power Supply | 220 V, 50–60 Hz |
| Brand | FLOXLAB |
|---|---|
| Origin | France |
| Model | ITB 100 |
| Test Principle | Indirect Tensile (Brazilian) Method via Radial Compression |
| Compliance | ASTM D3967, ISRM Suggested Method |
| Max Sample Diameter | 54.7 mm (NX core), 42.0 mm (BX), 38.1 mm (1.5″) |
| Sample Thickness Range | 0.2–0.75 × Diameter |
| Load Capacity | 100 kN |
| Construction Material | High-Grade Stainless Steel |
| Brand | FLOXLAB |
|---|---|
| Origin | France |
| Model | RSS 400 |
| Saw Blade Diameter | 400 mm (16 in) or 500 mm (20 in) |
| Max Cutting Depth | 125 mm (5 in) or 150 mm (6 in) |
| Max Sample Length | 300 mm |
| Cooling Medium | Water (standard), Optional Oil |
| Weight | 100 kg |
| Dimensions | 50 × 30 × 25 cm |
| Power Supply | 220 V, 50–60 Hz |
| Brand | FLOXLAB |
|---|---|
| Origin | France |
| Model | SPECIMEN CORING MACHINE |
| Drill Bit Internal Diameter | 21.5–63.5 mm (0.845–2.5 in) |
| Maximum Core Depth | 125 mm (5.0 in) |
| Cooling Medium | Water or Oil |
| Motor Power | 1,500 W |
| Dimensions (W×D×H) | 500 × 500 × 1800 mm |
| Weight | 150 kg |
| Power Supply | 220 V, 50–60 Hz |
| Brand | FLOXLAB |
|---|---|
| Origin | France |
| Model | SPECIMEN FLATNESS GAGE |
| Granite Base Dimensions | 200 mm × 300 mm × 50 mm |
| Max Sample Height | 300 mm (12 in) |
| Accuracy | ±0.0001 in |
| Resolution | 0.01 mm (0.0005 in) |
| Weight | 20 kg |
| Compliance | ASTM D4543 |
| Brand | FLOXLAB |
|---|---|
| Origin | France |
| Model | SPECIMEN GRINDER |
| Max Sample Diameter | 100 mm (4 in) |
| Max Sample Length | 200 mm (8 in) |
| Grinding Accuracy | ±0.001 in (±0.025 mm) |
| Grinding Wheel Diameter | 150 mm |
| Motor Power | 550 W |
| Speed | 3,000 rpm |
| Dimensions | 600 × 500 × 500 mm |
| Weight | 40 kg |
| Power Supply | 220 V, 50–60 Hz |
| Compliance | ASTM D4543 |
| Brand | FloXLab |
|---|---|
| Origin | France |
| Model | WCM |
| Sample Chamber Options | EX, AX, BX, NX, 1" Ø, 1.5" Ø |
| Drying Temperature | 150 °C |
| Drying Duration | 24 h |
| Vacuum Level | 10⁻³ mbar |
| Max Sample Weight | 2,500 g |
| Mass Resolution | 0.01 g |
| Sample Capacity | Variable (dependent on diameter) |
| Wetted Materials | ASTM A276 Type 316L Stainless Steel |
| Power Supply | 220 V/50 Hz or 110 VAC/60 Hz (configurable at order) |
| Brand | Floxlabs |
|---|---|
| Origin | France |
| Model | CAI 70 |
| Standard Compliance | ASTM D7625-10 |
| Load | 70 N |
| Max Sample Length | 150 mm |
| Max Sample Diameter | 76 mm |
| Scratch Resolution | 0.01 mm |
| Indenter Material | Steel, Rockwell Hardness HRC 54–56 |
| Weight | 25 kg |
| Dimensions (W × L × H) | 330 × 500 × 500 mm |
| Brand | FLOXLAB |
|---|---|
| Origin | France |
| Model | SPECIMEN TRIM SAW |
| Blade Diameter | 200 mm (8 in) |
| Blade Thickness | 2 mm |
| Max. Specimen Diameter | 54.7 mm (2.125 in) |
| Max. Specimen Length | 109.4 mm (4.3 in) |
| Positioning Accuracy (Dual-End Flatness) | ≤ 0.05 mm (0.002 in) |
| Motor Power | 550 W |
| Speed | 3,000 rpm |
| Coolant | Water (standard), Optional Oil-Based Coolant |
| Dimensions (W×D×H) | 700 × 800 × 600 mm |
| Weight | 60 kg |
| Power Supply | 220 V, 50–60 Hz |
| Brand | Flucon / flucon fluid control GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LAMBDA |
| Instrument Type | Hot Wire Method |
| Continuous Sample Capacity | Multiple samples |
| Test Environment | High-Temperature Operation |
| Thermal Conductivity Range | 10–2000 W/(m·K) |
| Accuracy | ±0.1% of reading |
| Dimensions (L×W×H) | 370 × 235 × 150 mm |
| Repeatability | 98–99% |
| Operating Temperature Range | −50 to +300 °C |
| Sample Forms | Liquids, colloids, powders |
| Compliance | ASTM D7896-19 |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fluigent-EISP |
| Pricing | Contact for Quotation |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | IMVS/IMPS |
| Sampling Rate | 60 MS/s |
| Time Resolution | 16 ns |
| Frequency Range | 10 mHz – 10 MHz |
| Current Resolution | <100 pA |
| LED Rise Time | 100 ns |
| Current Range | ±100 mA |
| Voltage Range | ±12 V (optional ±60 V with SMU module) |
| Spectral Coverage (Multi-LED) | 360–1100 nm |
| Temperature Range (optional cryo-thermo stage) | −120 °C to +150 °C |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | OPV/PSC |
| Sampling Rate | 60 MS/s |
| Time Resolution | 16 ns |
| Frequency Range | 10 mHz – 10 MHz |
| Current Resolution | < 100 pA |
| LED Rise Time | 100 ns |
| Current Range | ±100 mA |
| Voltage Range | ±12 V |
| Optional Modules | Multi-LED Source (360–1100 nm), Cryogenic Stage (−120 °C to +150 °C), Spectrometer Integration, SMU Extension (±60 V, 1 pA resolution) |