Protein Analysis
Filter
Showing 91–120 of 148 results
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | MCC-Q100 |
| Purification Principle | Gravity- or Pressure-Driven Manual Chromatography |
| Column Tube Material | Schott D263 Borosilicate Glass |
| Sealing Mechanism | Pneumatically Assisted Automatic Sealing (Q-Series) |
| Flow Path Design | Dead-Volume-Free |
| Wetted Materials Compliance | ASME BPE-2023 Compliant |
| Validation Support | Full GMP Documentation Package Available |
| Column Diameter Range | 100 mm (Standard) |
| Max Operating Pressure | ≤ 3 bar (Manual Compression System) |
| Cleaning & Sterilization | CIP/SIP Compatible |
| Column Head Design | Laterally Sliding, Tool-Free Adjustment |
| Bottom Screen Replacement | Hot-Swap Capable Without Column Disassembly |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | SPRi-EzPlex |
| Sample Volume | 200 µL (standard), optional 100/250/500 µL |
| Temperature Control Range | 15–40 °C, Accuracy: ±0.1 °C, Stability: ±0.01 °C |
| Detection Limit | 5 pg/mm² |
| Minimum Analyte MW | >240 Da |
| Sample Concentration Range | 150 ng/mL (for 100–1000 kDa) to 5 µg/mL (for 4–20 kDa) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | SPRi-OpenPlex |
| Sample Volume | 200 µL (standard), optional 100/250/500 µL |
| Detection Limit | 10 pg/mm² |
| Minimum Analyte MW | >240 Da |
| Sample Concentration Range | 300 ng/mL (for 100–1000 kDa) to 10 µg/mL (for 4–20 kDa) |
| Temperature Control | Not specified in input |
| Compliance | CE-marked, compatible with GLP/GMP workflows requiring audit trails and instrument qualification |
| Brand | Insplorion AB |
|---|---|
| Origin | Sweden |
| Model | Acoulyte |
| Sensor Diameter | 14 mm |
| Substrate | SiO₂-coated QCM-D crystal |
| Sensing Surface | Nanostructured gold |
| Standard Coatings | Si₃N₄, SiO₂, Al₂O₃, TiO₂ |
| Light Source | Tungsten-halogen lamp |
| Wavelength Range | 450–1000 nm |
| LSPR Sensitivity | ≤0.03 monolayer |
| Measurement Spot Diameter | 3 mm |
| Temporal Resolution | 10 Hz (10 samples/s) |
| Typical Noise Level | <0.01 nm |
| Optical Unit Dimensions (W×D×H) | 25×27×9 cm |
| Acoulyte Module Dimensions (W×D×H) | 8×5×3 cm |
| Software | Insplorer (Windows-compatible) |
| Data Export Format | ASCII text |
| Compatible Platforms | Q-Sense Explorer E1 & Analyzer E4 (with Q-Sense Window Module) |
| NPS Sensing Depth | <30 nm |
| QCM-D Hydrodynamic Penetration Depth | >300 nm |
| Simultaneous Output Parameters | LSPR resonance wavelength shift (Δλ), extinction intensity change, frequency shift (Δf), dissipation change (ΔD) |
| Brand | Insplorion AB |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NPS Sensor Chip |
| Pricing | Upon Request |
| Brand | Insplorion AB |
|---|---|
| Origin | Sweden |
| Model | S2 |
| Analysis Time | 2 s |
| Temperature Control Range | 15 °C–45 °C (±0.1 °C stability) |
| Flow Cell | Dual-channel |
| Sample Dead Volume | 20 µL |
| Standard Syringe Volume | 250 µL |
| Typical Flow Rate | 12.5–250 µL/min |
| Standard Loop Volume | 200 µL |
| Sensor Substrate | Fused Silica |
| Sensing Layer | Nanostructured Gold |
| Detection Depth | Up to 30 nm |
| Light Source | Tungsten-Halogen Lamp (≥2000 h lifetime) |
| Measurement Spot Diameter | 1.5 mm |
| Temporal Resolution | Up to 10 Hz |
| Optical Noise | <0.1 nm (at 1 Hz sampling) |
| Sensor Dimensions | 9.5 × 9.5 × 1 mm |
| System Dimensions | 65 × 42 × 36 cm |
| Weight | 30 kg |
| Software | InControl 1.0 (Windows-compatible) |
| Data Output | Proprietary CSV/TSV format |
| Brand | Insplorion AB |
|---|---|
| Origin | Sweden |
| Model | XNano |
| Measurement Principle | Nanoplasmonic Resonance Spectroscopy (NPS) |
| Sample Environment | Liquid or Gas Flow |
| Temperature Range | 25–80 °C (optional up to 250 °C) |
| Chip Substrate | Fused Silica (9.5 × 9.5 × 1 mm) |
| Sensing Surface | Nanostructured Gold |
| Coating Options | Au, SiO₂, Si₃N₄, TiO₂, Al₂O₃ |
| Optical Source | Tungsten-Halogen Lamp (≥2000 h lifetime) |
| Wavelength Range | 450–1000 nm |
| Spot Size | ~2 mm diameter |
| Time Resolution | 10 Hz (10 samples/sec) |
| Noise Level | < 0.01 nm (in liquid, 1 Hz sampling) |
| Flow Cell Volume | ~4 μL |
| Minimum Sample Volume | ~100 μL |
| Typical Flow Rate | 20–100 μL/min |
| Materials | Titanium & Perfluoroelastomer® |
| Dimensions (Measurement Unit) | 31 × 25 × 25 cm |
| Software | Windows-compatible, ASCII output, multi-parameter real-time export (resonance wavelength, linewidth, extinction) |
| Brand | Intavis |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | INTAVIS DigestPro MSi |
| Pricing | Available Upon Request |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HD-3000 |
| Detection Principle | UV Absorbance (214 nm, 254 nm, 280 nm, 340 nm) |
| Optical Path Length | 4 mm |
| Flow Cell Volume | 80 µL |
| Minimum Detectable Concentration | 48 µg/mL (at 280 nm, for BSA) |
| Absorbance Range | 0.05 A to 2 A (6 selectable ranges) |
| Wavelength Accuracy | ±1 nm |
| Data Interface | USB + RS-232 (COM) |
| Software | Proprietary chromatographic data acquisition & analysis suite (Windows XP/7/10 compatible) |
| Column Compatibility | Standard GE Healthcare/AKTA-compatible fittings (1/16" OD tubing, female Luer lock inlet/outlet) |
| Compliance | Designed per ISO/IEC 17025-relevant instrumentation requirements for analytical lab use |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HD-2000 |
| Detection Wavelengths | 220 nm, 254 nm, 280 nm, 340 nm |
| Wavelength Accuracy | ±1 nm |
| Flow Cell Path Length | 3 mm |
| Flow Cell Volume | 100 µL |
| Minimum Detectable Concentration | 48 µg/mL |
| Absorbance Range | 0.05 A – 2 A |
| Transmittance Range | 0–100 %T |
| Display | Triple-channel LED readout of OD values (A254, A280, A340 or user-selectable) |
| Microprocessor Control | Embedded MCU with real-time analog signal processing |
| Compatibility | Standard Luer-lock and GE/AKTA-compatible column interfaces |
| Gradient Type | Linear gradient support |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Power Supply | AC 220 V ±10 %, 50 Hz |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HD-2000 |
| Detection Wavelengths | 220 nm, 254 nm, 280 nm, 340 nm |
| Flow Cell | 100 µL volume, 3 mm path length |
| Absorbance Range | 0.05 A to 2 A (7 ranges) |
| Wavelength Accuracy | ±1 nm |
| Detector Type | Fixed-wavelength UV photometer |
| Gradient Capability | Linear gradient support |
| Interface | GE/AKTA-compatible column fittings |
| Display | LED-based, triple-channel OD readout (simultaneous display of three absorbance values) |
| Control | Embedded microcontroller architecture |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HD-3000 |
| Detection Wavelengths | 214 nm, 220 nm, 254 nm, 280 nm, 340 nm |
| Wavelength Accuracy | ±1 nm |
| Flow Cell | 80 µL volume, 4 mm path length |
| Absorbance Range | 0.05 A to 2 A (7 gain ranges) |
| Transmittance Range | 0–100 %T |
| Minimum Detectable Concentration | 48 µg/mL (for BSA at 280 nm) |
| Display | Triple-channel LED display of real-time OD values |
| Data Interface | USB and RS-232 (COM) |
| Software | Dedicated chromatography analysis software for Windows XP/7/10 (PC not included) |
| Compatibility | GE Healthcare AKTA system interface-ready |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear gradient support |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HD-97-1 |
| Detection Wavelengths | 220 nm, 254 nm, 280 nm, 340 nm |
| Wavelength Accuracy | ±1 nm |
| Flow Cell Path Length | 3 mm |
| Flow Cell Volume | 100 µL |
| Minimum Detectable Concentration | 48 µg/mL |
| Absorbance Range | 0.05 A – 2 A (7 ranges) |
| Transmittance Range | 0–100% T |
| Display | High-clarity LED, triple-channel OD readout |
| Control System | Embedded microcomputer chip |
| Compatibility | GE/AKTA-compatible column fittings |
| Gradient Type | Linear |
| Max. System Pressure | 3 MPa |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HD-97-1 |
| Detection Wavelengths | 220 nm, 254 nm, 280 nm, 340 nm |
| Flow Cell | 100 µL volume, 3 mm path length |
| Absorbance Range | 0.05 A to 2 A (7 ranges) |
| Wavelength Accuracy | ±1 nm |
| Compatibility | GE/AKTA-compatible column interfaces |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear |
| Display | LED, triple-channel OD readout (A₂₂₀, A₂₅₄, A₂₈₀) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-2000 |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear Gradient |
| Detection Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| Maximum System Pressure | 3 MPa |
| Light Source | LED (Lifespan > 50,000 h) |
| Optical Path Length | 2 mm |
| Sample Cell Volume | 10–120 µL |
| Baseline Noise | < 0.0001 A |
| Drift | ≤ 0.002 A/s |
| Sensitivity Range | 0.05–4 A (adjustable in 7 steps) |
| Zeroing | Dual-beam one-touch auto-zero |
| Display | High-definition blue-membrane LCD |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 205 × 300 × 180 mm |
| Weight | 2.6 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-3000 |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear Gradient |
| Detector Type | UV-Vis Absorbance Detector |
| Detection Range | –6 AU to +6 AU |
| Pressure Rating | 3 MPa |
| Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| Minimum Detectable Concentration | 20 µg/mL |
| Light Source | LED (Lifespan > 50,000 h) |
| Optical Path Length | 2 mm |
| Flow Cell Volume | 10–120 µL |
| Baseline Stability | Drift ≤ 0.002 A/h |
| Noise | < 0.0001 A (RMS) |
| Sensitivity Settings | 0.05–4 A full scale |
| Zero Adjustment | Dual-beam real-time auto-zero |
| Display | High-contrast blue-membrane LCD |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 205 × 300 × 180 mm |
| Weight | 2.6 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-3001 |
| Purification Principle | Gel Filtration Chromatography (GFC) |
| Gradient Type | Linear Gradient |
| Detector Type | Dual-Beam UV Absorbance Detector |
| Detection Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| Minimum Detectable Concentration | 20 µg/mL |
| Light Source | High-Stability LED (Lifespan > 50,000 h) |
| Optical Path Length | 2 mm |
| Flow Cell Volume | 10–120 µL |
| Baseline Noise | < 0.0001 AU |
| Drift | ≤ 0.002 AU/s |
| Absorbance Sensitivity Range | 0.05–2.0 AU (adjustable in 6 steps) |
| Zero Calibration | Real-time dual-beam auto-zero |
| Display | 10.1-inch capacitive touchscreen LCD |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 290 × 330 × 470 mm |
| Weight | 9 kg |
| Max Operating Pressure | 3 MPa |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-3006 |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear |
| Flow Rate Range | 0.1–10 mL/min |
| Flow Rate Accuracy | ±1.2% |
| Detection Range | −6 AU to +6 AU |
| Maximum Pressure | 3 MPa |
| UV Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| Wavelength Accuracy | ±1 nm |
| Linearity | ±1.5% (0–2 AU) |
| Sample Cell Volume | 10 µL |
| Operating Temperature | 4–40 °C |
| Dimensions (W×D×H) | 345 × 380 × 255 mm |
| Weight | 6.6 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-3007 |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear Gradient |
| Detector Type | UV Absorbance Detector |
| Flow Rate Range | 0.1–10 mL/min |
| Flow Rate Accuracy | ±1.2% |
| Detection Range | –6 AU to +6 AU |
| Maximum Pressure | 3 MPa |
| Wavelength Options | 260 nm, 280 nm, 295 nm, 310 nm |
| Wavelength Accuracy | ±1 nm |
| Linearity | ±1.5% (0–2 AU) |
| Sample Cell Volume | 10 µL |
| Operating Temperature | 4–40 °C |
| Dimensions (W×D×H) | 360 × 360 × 470 mm |
| Weight | 10.6 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-3008 |
| Detection Range | 190–400 nm |
| Light Source | Deuterium Lamp (≥1000 h warranty) |
| Optical Path Length | 1 mm |
| Flow Cell Volume | 10–120 µL |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ≤ ±1 nm |
| Wavelength Repeatability | ≤ ±0.1 nm |
| Baseline Noise | < 0.0001 AU |
| Baseline Drift | ≤ 0.002 AU/s |
| Wavelength Control | Stepper Motor–Driven Monochromator |
| Data Acquisition Rate | Dual-Channel High-Speed Sampling |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 340 × 330 × 175 mm |
| Weight | 6 kg |
| Integrated Touchscreen Display | 12-inch Industrial LCD |
| Brand | JIZHOU |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MCH |
| Pricing | Upon Request |
| Column Tube ID | 70–450 mm |
| Column Tube Height | 500–1000 mm |
| Packing Height Range | 0–82 cm |
| Max Operating Pressure | ≤8 bar |
| Weight | 15–230 kg |
| Material Compliance | USP Class VI (USP <88> In Vivo Biological Reactivity Testing) |
| Sealing | O-ring interface between platen and column tube |
| Screen Retention | Snap-fit design |
| Construction | Precision borosilicate glass tube (bubble-free, scratch-free surface) |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-Keebio3009 |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Isocratic & Step Gradient |
| UV Detector Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| Flow Rate Range | 0.1–10 mL/min |
| Flow Accuracy | ±1.2% |
| UV Detection Range | –6 to +6 AU |
| Linearity | ±1.5% (0–2 AU) |
| Maximum System Pressure | 3 bar |
| Conductivity Range | 0.001–400.00 mS/cm |
| Accuracy | ±2% (with temperature compensation) |
| Solvent Compatibility | Aqueous buffers, common chromatographic mobile phases, and biocompatible solutions used in protein purification |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JP-KeebioGO |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Types | Isocratic, Linear, and Step Gradients |
| Flow Rate Range | 0.001–25 mL/min |
| Flow Rate Accuracy | ±1.2% |
| UV Detection Range | –6 to +6 AU |
| Linearity | ±1.5% (0–2 AU) |
| Maximum System Pressure | 0–10 MPa (1500 psi) |
| Conductivity Range | 0.001–400.00 mS/cm |
| Accuracy | ±2% with temperature compensation |
| pH Range | 0–14 (measurable range 2–12) |
| Accuracy | ±0.1 with temperature compensation |
| Temperature Sensor Range | 0–100 °C |
| Accuracy | ±1 °C |
| Detector Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| Wavelength Accuracy | ±1 nm |
| Repeatability | ±0.1 nm |
| Sample Cell Volume | 10 µL |
| Bubble Sensors | Installed at A/B inlets and sample inlet |
| Injection Valve | 3-position, 7-port, software-controllable, supporting Load/Inject/Waste modes |
| Fraction Collection Compatibility | JP-KeebioFC with configurable rack support |
| Data Export Format | Native Excel (.xlsx) |
| Operating Temperature | 4–40 °C |
| Dimensions (W×D×H) | 360 × 380 × 470 mm |
| Weight | 20 kg |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JP-KeebioStart |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear Gradient |
| Flow Rate Range | 0.1–10 mL/min |
| Flow Accuracy | ±1.2% |
| UV Detection Range | −6 to +6 AU (Linearity: ±1.5% within 0–2 AU) |
| Maximum Pressure | 3 MPa (30 bar) |
| Conductivity Range | 0.001–400.00 mS/cm |
| Conductivity Accuracy | ±2% |
| Temperature Detection Range | 0–100 °C (Accuracy: ±1 °C) |
| UV Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| UV Light Source | LED (Cold Light) |
| Wavelength Accuracy | ±1 nm |
| Sample Cell Volume | 10 µL |
| Mixer Volume | 200 µL (Static) |
| Fraction Collection | Optional JP-blupadFC collector with XY-axis positioning, peak-triggered collection (AU threshold, slope, conductivity), full-collection, and manual modes |
| Software | JP-blupad Chromatography Workstation (Registered Copyright No. 2019SR0680657) |
| Certifications | CN Utility Model Patent ZL201920802201.1, CN Design Patent ZL202130391697.0, CN Invention Patent ZL202110687106.3 |
| Operating Temperature | 4–40 °C |
| Dimensions (W×D×H) | 360 × 380 × 470 mm |
| Weight | 11 kg |
| Power Supply | 220 VAC |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JP-Keebio |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Profile | Linear Gradient |
| UV Detection Range | –6 AU to +6 AU |
| Linearity | ±1.5% (0–2 AU) |
| Output Voltage Range | –500 mV to +1500 mV |
| Integration Sensitivity | 1 µV/s |
| Minimum Resolution | 0.1 µV |
| Minimum Peak Width | 0.1 s |
| Input Impedance | >10 MΩ |
| Repeatability | ±0.01% |
| Maximum Sampling Rate | 100 Hz |
| Interface | USB 2.0 |
| Operating Temperature | 4–40 °C |
| OS Compatibility | Windows 10 & 11 |
| Power Supply | 220 VAC |
| Dimensions (L×W×H) | 180 × 140 × 20 mm |
| Weight | 0.7 kg |
| Brand | KNAUER |
|---|---|
| Origin | Germany |
| Model | Bio FPLC |
| Pump Flow Ranges | 0.001–10 mL/min (10 mL module), 0.001–50 mL/min (50 mL module), 0.001–1000 mL/min (100–1000 mL modular pump head upgrade) |
| Detector | External flow cell UV-Vis detector with user-removable flow cell |
| Valve Configurations | Buffer selection, column switching, fraction collection |
| System Series | Compact (R&D scale), Pilot (process-scale) |
| Supported Chromatography Modes | Size-exclusion (SEC), Ion-exchange (IEX), Affinity, Hydrophobic Interaction (HIC) |
| Advanced Configuration Option | Simulated Moving Bed (SMB) for continuous purification |
| Brand | KSV |
|---|---|
| Origin | Finland |
| Model | SPR-NAVI |
| Measurement Principle | Angular-interrogation SPR with rotating laser |
| Wavelength | 670 nm (optional alternate wavelengths available) |
| Angular Resolution | 0.005° |
| Refractive Index (RI) Range | 1.00–1.45 |
| SPR Angle Range | 40–80° |
| Detection Limit | ΔRI = 3 × 10⁻⁶ (equivalent to ~3 pg/mm² for protein adsorption) |
| Flow Cell Volume | 1 µL |
| Sample Volume per Injection | ≥20 µL |
| Temperature Control Range | 8–40 °C (0.5 °C increments) |
| Fluid Handling | Dual-channel, manual 12-port syringe injector |
| Pump | Dual-channel conductive, software-controlled |
| Dimensions (H×W×D) | 38 × 32 × 31 cm |
| Weight | 10 kg |
| Power Supply | 150 W, 100/240 V AC, 50/60 Hz |
| Interface | USB 2.0, Windows OS compatible |
| Brand | Malvern PANalytical |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | WAVEdelta |
| Instrument Principle | Grating-Coupled Interferometry (GCI) |
| Channel Configuration | Multi-channel |
| Detection Range | pM to mM |
| Sample Format Support | Dual microplate carriers (96-well or 384-well, standard or deep-well) or 48-position 1.5 mL vial rack |
| Injection Volume | < 450 µL (typical: 100 µL) |
| Assay Duration | 0–120 h |
| Temperature Control Range | 4 °C – 45 °C |
| Brand | Mecwins |
|---|---|
| Origin | Spain |
| Model | AVAC |
| Detection Principle | Plasmonic Nanoparticle Scattering Spectroscopy |
| Sensitivity | 3 fM LoD (miRNA-122) |
| Throughput | 96-well plate in 5 min |
| Max Image Acquisition Rate | 20,000 images/hour |
| Multiplex Capacity | Up to 5 analytes per sample |
| Counting Range | 10²–10⁶ molecules/field |
| Spatial Resolution | 0.7 µm (diffraction-limited) |
| Substrate | Functionalized polymer matrix (silicon-free) |
| Automation Level | Fully automated loading, imaging, and ejection |
| Sample Types | Serum, plasma, CSF, urine, and other biological fluids |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MidiLab9000-Marker |
| Pricing | Available upon Request |