| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | RX-7000α |
| Measurement Range | Brix 0.00–100.00%, nD 1.29980–1.71500 |
| Accuracy | ±0.1% Brix, ±0.0001 nD, ±0.05°C Temperature |
| Temperature Control Range | 5.00–70.00°C (Peltier-based, no external chiller required) |
| Resolution | 0.01% Brix, 0.00001 nD, 0.01°C |
| Sample Cell Material | SUS316 stainless steel |
| Prism Material | Synthetic sapphire |
| Interface | RS-232C for printer & PC connectivity |
| Power | AC 100–240 V, 50/60 Hz, 65 VA |
| Dimensions & Weight | 37 × 26 × 14 cm, 6.8 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | RX-7000α |
| Type | Benchtop Refractometer |
| Temperature Control | Peltier-based |
| Display | Digital LCD |
| Refractive Index Range | 1.29980–1.71500 |
| Brix Range | 0.00–100.00% |
| RI Accuracy | ±0.0001 |
| Brix Accuracy | ±0.1% |
| Temperature Accuracy | ±0.05°C |
| Temp. Control Range | 5.00–70.00°C (ambient lower limit: –10°C) |
| RI Resolution | 0.00001 |
| Brix Resolution | 0.01% (default) |
| Temp. Resolution | 0.01°C |
| Custom Scales | Up to 30 user-defined units |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | RX-7000α |
| Measurement Range | Brix 0.00–100.0% |
| Accuracy | ±0.1% Brix |
| Display | Digital LCD |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | None |
| Compliance | ISO 21542, ASTM D1218, JIS K 0061 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | RX-7000α |
| Type | Benchtop Refractometer |
| Temperature Control | Peltier-based, 5.00–70.00 °C (±0.05 °C) |
| Digital Display | Yes |
| Refractive Index Range | 1.29980–1.71500 nD |
| Refractive Index Accuracy | ±0.0001 nD (repeatability ±0.00005 nD) |
| Resolution | 0.00001 nD |
| Brix Range | 0.00–100.00% |
| Brix Accuracy | ±0.1% (repeatability ±0.02%) |
| Brix Resolution | 0.01% |
| Prism Material | Synthetic Sapphire |
| Sample Stage Material | SUS316 Stainless Steel |
| Interface | RS-232C |
| Data Output | Optional thermal printer & PC connectivity |
| Custom Scales | Up to 30 user-defined scales |
| Power | AC 100–240 V, 50–60 Hz, 65 VA |
| Dimensions | 37 × 26 × 14 cm |
| Weight | 6.8 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | RX-9000i |
| Product Type | Benchtop Refractometer |
| Temperature Control | Peltier-based integrated thermostatic system |
| Digital Display | Yes |
| Measurement Range | Refractive Index (nD): 1.299800–1.715000 |
| Brix | 0.00–100.00% |
| Accuracy | Refractive Index: ±0.000040 |
| Brix | ±0.03% |
| Temperature Accuracy | ±0.05°C |
| Temperature Range | 5.00–75.00°C |
| Resolution | nD: 0.000001 |
| Brix | 0.01% |
| Temp | 0.01°C |
| Sample Cell Material | SUS316 stainless steel |
| Prism Material | Synthetic sapphire |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | 90 VA |
| Dimensions & Weight | 37 × 26 × 14 cm, 7.0 kg (main unit only) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | RX-9000i |
| Measurement Range | 0.00–100.00% (Brix or custom concentration units) |
| Accuracy | ±0.000040 refractive index units (nD) |
| Display | Digital LCD |
| Temperature Control | None |
| Instrument Type | Benchtop Refractometer |
| Compliance | ISO 21745, ASTM D1218, USP <781>, JIS K 0061 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | RX-9000α |
| Product Type | Benchtop Refractometer |
| Display | Digital LCD |
| Measurement Range | 0.00–100.00% (Brix or concentration units) |
| Accuracy | ±0.03% |
| Temperature Control | Not equipped |
| Compliance | CE-marked, conforms to JIS K 0061 and ISO 21748 for refractometric measurement principles |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | RX-9000α |
| Product Type | Benchtop Refractometer |
| Temperature Control | Peltier-based thermostatic control (5–70 °C) |
| Digital Display | Yes |
| Refractive Index Range | 1.29980–1.71500 nD |
| Brix Range | 0.00–100.00% |
| Refractive Index Accuracy | ±0.00004 (nD 1.33299–1.42009, at 10.00–30.00 °C) / ±0.00010 (nD >1.42009) |
| Brix Accuracy | ±0.03% (0.00–50.00%, 10.00–30.00 °C) / ±0.05% (50.01–95.00%, 10.00–30.00 °C) / ±0.10% (all other conditions, MODE-1 sucrose calibration) |
| Resolution | nD: 0.00001 |
| Brix | 0.01% |
| Temperature | 0.01 °C |
| Dimensions & Weight | 370 × 260 × 140 mm, 6.9 kg (main unit only) |
| Power Supply | AC 100–240 V, 50/60 Hz, 65 VA |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | RX-9000α |
| Product Type | Desktop Refractometer |
| Temperature Control | Peltier-based, 5.00–70.00 °C |
| Display | Digital LCD |
| Refractive Index Range | 1.29980–1.71500 |
| Brix Range | 0.00–100.00% |
| RI Resolution | 0.00001 |
| Brix Resolution | 0.01% |
| Temperature Resolution | 0.01 °C |
| RI Accuracy | ±0.00004 (±0.00010 for RI ≥1.42009) |
| Brix Accuracy | ±0.03% (±0.05% for 50.01–95.00%) |
| Temp Accuracy | ±0.05 °C (10.00–30.00 °C) |
| Interface | RS-232C |
| Power | AC 100–240 V, 50/60 Hz, 65 VA |
| Dimensions | 370 × 260 × 140 mm |
| Weight | 6.8 kg |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | RX-9000α |
| Pricing | Upon Request |
| Refractive Index (nD) Range | 1.32500–1.70000 |
| Brix Range | 0.00–100.00% (ATC: 5–70°C) |
| nD Resolution | 0.00001 / 0.0001 |
| Brix Resolution | 0.01% / 0.1% |
| Temperature Resolution | 0.01°C |
| nD Accuracy | ±0.00004 (1.33299–1.42009, 10.00–30.00°C) |
| Brix Accuracy | ±0.03% (0.00–50.00%, 10.00–30.00°C) |
| nD Repeatability | ±0.00002 (1.33299–1.42009, 10.00–30.00°C) |
| Brix Repeatability | ±0.01% (0.00–50.00%, 10.00–30.00°C) |
| Temperature Control Range | 5–70°C |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions & Weight | 37 × 26 × 14 cm, 6.9 kg |
| Power Consumption | 65 VA |
| Interface Options | RS-232C, optional thermal printer (DP-RX / DP-RD) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | RX-DD7α-tea |
| Product Type | Benchtop Refractometer |
| Temperature Control | Peltier-based thermostatic control |
| Display | Digital LCD |
| Measurement Range | 0.000–5.000% (w/w, sucrose-equivalent scale for tea & low-sugar beverages) |
| Accuracy | ±0.005% |
| Resolution | 0.001% |
| Connectivity | RS-232/USB interface for PC and printer |
| Compliance | FDA 21 CFR Part 11 compliant data logging software included |
| Calibration | One-touch zero calibration with distilled water |
| Housing | Rugged die-cast metal chassis |
| User Interface | Two-button operation (START / ZERO) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | SMART-1 |
| Product Type | Benchtop Refractometer |
| Display | Digital LCD |
| Measurement Range | 0.00–95.00 % Brix |
| Temperature Range for Measurement | 5.00–40.00 °C |
| Temperature Compensation | Automatic (ATC, based on built-in thermistor) |
| Compliance | ISO 2173, AOAC 932.12, ICUMSA Methods |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | T3-NE |
| Measurement Range | 1.333–1.360 RI |
| Resolution | 0.001 RI |
| Temperature Control | Yes |
| Digital Display | Yes |
| Instrument Type | Benchtop Refractometer |
| Scale Types | Urine Specific Gravity (USG), Serum Protein (g/dL), and Refractive Index (RI) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | T3-RX/RI |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Brix Range | 0.0–18.0% |
| RI Range | 1.3300–1.3605 |
| Brix Resolution | 0.2% |
| RI Resolution | 0.0005 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | UG-α |
| Type | Handheld Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 1.0000–1.0600 |
| Accuracy | ±0.001 |
| Compliance | ISO 17025 traceable calibration capability (per ATAGO factory standard) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | UG-α (Urine Specific Gravity) |
| Product Type | Handheld Refractometer |
| Temperature Control | None |
| Digital Display | Yes |
| Measurement Range | 1.0000–1.0600 |
| Accuracy | ±0.0010 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | WM-7 |
| Product Type | Handheld Refractometer |
| Brix Range | 0.0–45.0% |
| Brix Resolution | 0.1% |
| Brix Accuracy | ±0.1% |
| Temperature Compensation | Automatic (5–40°C) |
| Measurement Time | 3 seconds |
| Display Scales | 7 (Brix, TA-1990, TA-1971, °Oe GER, °Oe, °KMW, °Bé) |
| IP Rating | IP65 |
| Power | 9V alkaline battery (006P) |
| Dimensions | 17 × 9 × 4 cm |
| Weight | 270 g (instrument only) |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | RFM300-T |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Peltier-controlled prism (±0.01 °C stability) |
| Display | 7-inch capacitive touchscreen |
| Measurement Range | Refractive Index (RI): 1.32000–1.58000 |
| °Brix | 0.00–100.00 |
| Resolution | RI: 0.00001 |
| °Brix | 0.01 |
| Accuracy | ±0.00002 RI / ±0.02 °Brix (at 20 °C, sucrose standard) |
| Sample Capacity | ≥1.5 mL |
| Data Storage | >8,000 readings with timestamp, user ID, method ID, and temperature log |
| Compliance | FDA 21 CFR Part 11 (electronic signatures, audit trail, role-based access), GLP/GMP-ready |
| Connectivity | USB 2.0 (PDF export, configuration clone, firmware update), optional RS-232 |
| Language Support | English, German, French, Spanish, Italian, Chinese, Japanese, Korean |
| Custom Scale Support | Up to 100 user-defined scales (e.g., citric acid offset for orange juice, coffee solids drift compensation) |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | RFM340-T |
| Product Type | Benchtop Refractometer |
| Temperature Control | Peltier-based, programmable (5–40 °C, ±0.01 °C stability) |
| Display | 7-inch capacitive touchscreen |
| Measurement Range | Refractive Index (nD) 1.320000–1.580000 |
| Resolution | 0.000001 RI / 0.001 °Brix |
| Accuracy | ±0.00002 RI / ±0.01 °Brix (at 20 °C, sucrose standard) |
| Sample Volume | 0.5–2.0 mL |
| Prism Material | Sapphire-coated optical glass |
| Data Storage | >8,000 measurements with timestamp, user ID, method ID, and temperature log |
| Compliance | FDA 21 CFR Part 11 (electronic signatures, audit trail), GLP/GMP-ready |
| Connectivity | USB 2.0 host/device, optional Ethernet |
| Language Support | 12 UI languages (English, German, French, Spanish, Italian, Portuguese, Dutch, Polish, Czech, Turkish, Chinese, Japanese) |
| Brand | B+S / Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | RFM742-M(74F) |
| Product Type | Benchtop Refractometer |
| Display | 4-inch high-resolution color LCD |
| Measurement Range | °Brix 0–100 |
| Resolution | 0.01 °Brix / 0.00001 RI |
| Temperature Compensation | ICUMSA-compliant to 20 °C (AG algorithm) |
| Data Output | USB interface |
| export formats | CSV, PDF (password-protected), standard printer protocol |
| Compliance Features | Audit trail (date, time, batch ID, operator ID), alphanumeric keypad, multi-scale user-defined calibration |
| Prism Material | Sapphire |
| Housing | Stainless steel sample stage with splash guard barrier |
| Power | External AC adapter |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | RFM960-T |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Peltier-based, active stabilization |
| Display | Touchscreen LCD |
| Measurement Range | Refractive Index (RI) 1.300000–1.700000 |
| °Brix | 0.00–100.00 |
| Resolution | RI 0.000001 (1 ppm), °Brix 0.01 |
| Accuracy | ±0.0001 RI / ±0.1 °Brix |
| Sample Interface | Low-profile sample stage with non-contact pneumatic cover |
| Data Storage | 8,000+ measurements with timestamp, user ID, and temperature metadata |
| User Authentication | RFID card reader integrated into top panel |
| Compliance | Designed for GLP/GMP environments |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | RFM970-T |
| Type | Benchtop Refractometer |
| Temperature Control | Peltier-based, integrated |
| Display | High-resolution capacitive touchscreen |
| Measurement Range | Refractive Index (RI) 1.300000–1.700000 |
| °Brix | 0.000–100.000 |
| Resolution | RI ±0.000001 |
| Accuracy | ±0.000002 RI / ±0.002 °Brix (at 20 °C, traceable to NIST-certified standards) |
| Sample Chamber | Low-profile stainless-steel prism with non-contact pneumatic cover |
| Data Storage | 8,192 measurement records with timestamp, user ID, temperature, and method metadata |
| RFID Authentication | Integrated ISO 14443-A compliant reader for operator identification and access-controlled configuration |
| Compliance | Designed to support GLP/GMP workflows with audit trail-ready data export (CSV/Excel), 21 CFR Part 11–compatible optional software module |
| Brand | Bellingham + Stanley (B+S) |
|---|---|
| Origin | United Kingdom |
| Model | Abbe 60/LR & Abbe 60/ED |
| Refractive Index Range | 1.20–1.70 RI (Abbe 60/LR), 1.30–1.74 RI (Abbe 60/ED) |
| Accuracy | ±0.00004 RI |
| Operating Temperature | 5–75 °C (digital display, 0.1 °C resolution) |
| Light Sources | Sodium D-line (589.3 nm), optional spectral lamps for multi-wavelength measurement |
| Compliance | ASTM D1218, BS EN ISO 9001:2000, UKAS-accredited manufacturing, CE marked |
| Enclosure | Chemically resistant, IP-rated housing |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | Abbe5 |
| Measurement Range | 1.30–1.70 RI, 0–95 % °Brix |
| Resolution | 0.0005 RI, 0.25 % °Brix |
| Operating Temperature | 5–70 °C |
| Temperature Display | Built-in digital sensor, 0.1 °C resolution |
| Light Source | Sodium D-line (589.3 nm) |
| Housing | Chemical-resistant, IP-rated enclosure |
| Compliance | BS EN ISO 9001:2000, UKAS-accredited manufacturing, CE marked |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | ADP600 |
| Type | Benchtop Polarimeter |
| Temperature Control | Peltier-based |
| Display | High-resolution 7.4" color touchscreen |
| Wavelength Options | Single, dual, or up to six discrete wavelengths (325 nm, 365 nm, 405 nm, 436 nm, 546 nm, 589 nm) |
| Measurement Range | ±89°A (extendable to –355°A to +355°A via method selection) |
| Resolution | 0.0001°A |
| Accuracy | ±0.003°A (@546 nm and 589 nm) |
| Temperature Range | 15–35 °C |
| Temp. Control Precision | ±0.2 °C |
| Temperature Setpoints | 20 °C and 25 °C (user-adjustable within 20–30 °C range per method) |
| Sample Cell Length | 5–200 mm |
| Cell Diameter | 3–8 mm |
| Optical Density Range | 0.0–3.0 OD |
| Calibration Modes | Sucrose, quartz, user-defined, or no compensation |
| Measurement Modes | Specific rotation, concentration (% w/w), invert sugar %, differential (A–B) % |
| Readout Time | 15–60 s (@546/589 nm, 20/20 °C instrument/sample) |
| Light Source | UV–Vis lamp (6 V, 2 A) with narrow-band interference filters |
| Interfaces | 4 × USB, 1 × Ethernet, 1 × RS232 |
| Power Supply | 100–250 V~, 50–60 Hz, <6 A |
| Regulatory Compliance | FDA 21 CFR Part 11, USP <781>, EP 2.2.7, JP XVI |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | DR |
| Measurement Scales | °Brix (0–92), RI (1.3330–1.5230), Alcohol (% v/v), Oechsle, KMW, Baumé |
| Resolution | 0.1 °Brix / 0.0001 RI / 0.1° Alcohol / 1° Oechsle |
| Accuracy | ±0.2 °Brix / ±0.0003 RI / ±0.2° Alcohol / ±1° Oechsle |
| ATC (Automatic Temperature Compensation) | Yes |
| Construction | Full-metal body with thermal-insulating rubber grip |
| Compliance | BS EN ISO 9001:2000, UKAS-accredited manufacturing, CE-marked |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | DR Series Digital Handheld |
| Temperature Control | Yes (ATC) |
| Digital Display | Yes |
| Product Type | Handheld Refractometer |
| Construction | Full-metal body with thermal-insulating rubber grip |
| Prism cover | Slide-action flip cover |
| Sample application | Drop-on method |
| Sample temperature range | Compatible with both chilled and heated samples |
| Key Specifications (DR103L) | Brix 0–45%, resolution 0.1%, accuracy ±0.2% |
| Key Specifications (DR112) | Brix 28–65%, resolution 0.1%, accuracy ±0.2% |
| Key Specifications (DR122) | Brix 60–92%, resolution 0.1%, accuracy ±0.2% |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Type | Benchtop Refractometer |
| Model | E-Line |
| Temperature Control | Yes (Automatic Temperature Compensation) |
| Digital Display | Yes |
| Construction | All-metal body with heat-insulating rubber grip |
| Compliance | Designed to meet ISO 21748 and ASTM D1218 standards for refractive index measurement |
| Brand | Bellingham + Stanley |
|---|---|
| Country of Origin | United Kingdom |
| Model | E-Line |
| Compliance | BS EN ISO 9001, UKAS Accredited, CE Marked |
| Optical Principle | Critical Angle Refraction (Abbe-type) |
| Temperature Compensation | Automatic Temperature Compensation (ATC) |
| Construction | All-metal body with thermal-insulating rubber grip |
| Ergonomics | Optimized hand-held geometry for single-handed operation |
| Scale Resolution | 0.1–0.5 °Brix depending on model |
| Measurement Range | 0–90 °Brix (multi-range variants available) |
| Prism Type | High-grade optical glass with spring-loaded flip cover |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | Eclipse |
| Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| IP Rating | IP66 |
| Construction | All-metal body with insulated rubber ergonomic grip |
| Prism Cover | Spring-loaded push-to-close mechanism |
| Zero Adjustment | Lockable fine-tuning screw |
| Sample Volume | < 1 mL |
| Compliance | Fully traceable serial-numbered units with calibration certificate supplied |