- All
- Favorite
- Popular
- Most rated
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | KANOMAX 3443 |
| Measurement Principle | Optical Light Scattering |
| Particle Size Range | 0.1–10 µm |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Data Storage Capacity | 500 records |
| Sampling Interval | Configurable from 10 to 3600 seconds (default options: 24 s, 120 s) |
| Communication Interface | RS-232C |
| Safety Classification | Non-explosion-proof |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | SDM-II+ |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | PM2.5, PM10, TSP |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Sampling Flow Rate | 1.7 L/min |
| Zero & Span Auto-Calibration | Yes |
| Humidity Compensation | Integrated Automatic Dehumidification |
| Alarm Threshold Setting | Configurable Concentration Limit |
| Communication Interface | RS485 |
| Power Supply | DC 10–15 V, 2 A |
| Dimensions (W×H×D) | 250 × 350 × 170 mm (unit only) |
| Weight | ~4.5 kg (unit only) |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | KD11 |
| Measurement Principle | Piezoelectric Microbalance (QCM) |
| Particle Size Range | 0.1–10 µm (PM10), 0.1–2.5 µm (PM2.5) |
| Concentration Range | 0.01–10.00 mg/m³ |
| Flow Rate | 1.0 L/min |
| Data Storage Capacity | 500 measurement records |
| Sampling Duration | Fixed modes (24 s, 120 s) or user-defined (10–3600 s) |
| Communication Interface | RS-232C |
| Power Supply | Rechargeable Ni-MH battery / AC adapter (100–240 V AC) |
| Battery Life | ~4.5 h continuous operation |
| Charging Time | 5–8 h |
| Dimensions (W×L×H) | 65 × 182 × 150 mm |
| Weight | ~1.75 kg |
| Auto-Cleaning Alert | Yes (triggered upon crystal mass loading threshold exceedance) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3443 |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | 0.1–10 μm |
| Measurement Range | 0.001–10.000 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Data Storage Capacity | 100,000 records |
| Communication Interface | USB |
| Analog Output | 0–1000 CPM / 0–1 V |
| Dimensions | 162 mm (W) × 60 mm (D) × 109 mm (H) |
| Weight | Approx. 1.3 kg (including rechargeable battery) |
| Safety Classification | Non-explosion-proof |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KD11 |
| Operating Principle | Tapered Element Oscillating Microbalance (TEOM™-style piezoelectric resonant frequency shift) |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% of reading |
| Relative Error | ≤±2% |
| Particle Size Range | 0.1–10 µm (PM₁₀ mode) |
| Sample Flow Rate | 1.0 L/min |
| Data Storage Capacity | 500 measurement records |
| Communication Interface | RS-232C |
| Power Supply | Rechargeable Ni-MH battery or AC adapter (100–240 V AC) |
| Battery Life | ~4.5 hours continuous operation |
| Charging Time | 5–8 hours |
| Dimensions | 65 × 182 × 150 mm (W × L × H) |
| Weight | ~1.75 kg |
| Safety Classification | Non-explosion-proof |
| Compliance | Designed for occupational hygiene and environmental monitoring per ISO 7708, ISO/IEC 17025-aligned operational practices, and compatible with OSHA/NIOSH PM sampling protocols |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | SDM-II |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | PM2.5, PM10, TSP |
| Measurement Range | 0.001–30.000 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Sampling Flow Rate | 1.7 L/min |
| Zero & Span Auto-Calibration | Yes |
| Alarm Threshold Setting | Yes |
| Automatic Dehumidification | Yes |
| Communication Interface | RS485 |
| Power Supply | DC 10–15 V, 2 A |
| Dimensions (w/o case) | 250 × 350 × 170 mm |
| Weight (w/o case) | ~4.5 kg |
| Weight (with case) | ~8 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3443 |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | 0.1–10 µm |
| Concentration Range | 0.001–10.000 mg/m³ |
| Data Storage Capacity | 100,000 records |
| Communication Interface | USB |
| Analog Output | 0–1 V (corresponding to 0–1000 CPM or 0–10,000 CPM) |
| Dimensions | 162 mm (W) × 60 mm (D) × 109 mm (H) |
| Weight | Approx. 1.3 kg (including rechargeable battery) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3443 |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | 0.1–10 μm |
| Measurement Range | 0.001–10.000 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Data Storage Capacity | 100,000 records |
| Communication Interface | USB |
| Analog Output | 0–1 V corresponding to 0–1000 CPM or 0–10,000 CPM |
| Dimensions | 162 mm (W) × 60 mm (D) × 109 mm (H) |
| Weight | Approx. 1.3 kg (including rechargeable battery) |
| Safety Classification | Non-explosion-proof |
| Compliance | Meets China’s Ministry of Health PM₁₀ monitoring requirements |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | SXYC-508 |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Safety Classification | Non-explosion-proof |
| Compliance Standard | HJ/T 212–2005 |
| Detection Principle | Beta-ray attenuation (integrated gravimetric reference via filter sampling) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Kanomax SXYC-508 |
| Operating Principle | Optical Scattering (β-ray attenuation & integrated gravimetric verification) |
| Safety Rating | Non-explosion-proof |
| Dust Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Noise Range | 30–130 dB(A) |
| Noise Accuracy | ±0.5 dB |
| Atmospheric Pressure Range | 10–1100 hPa |
| Pressure Accuracy | ±0.3 hPa |
| Wind Speed Range | 0.00–70.0 m/s |
| Wind Speed Accuracy | ±0.03 m/s |
| Wind Direction Range | 0–360° |
| Direction Accuracy | ±0.5° |
| Temperature Range | −50–100°C |
| Humidity Range | 0–100% RH |
| Temp/Humidity Accuracy | ±0.5°C / ±3% RH |
| Power Consumption | 30 W |
| Power Supply | AC 220 V ±10% with backup battery (≥6 h runtime) |
| Data Protocol Compliance | HJ/T 212–2005 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3443 |
| Measurement Principle | Optical Light Scattering (90° detection geometry) |
| Particle Size Range | 0.1–10 μm |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% of reading |
| Relative Error | ≤ ±2% |
| Sampling Duration | Programmable from 10 to 3600 seconds (preset modes: 24 s and 120 s) |
| Data Storage Capacity | 500 records |
| Communication Interface | RS-232C compliant |
| Safety Classification | Non-explosion-proof |
| Compliance | Designed for indoor/outdoor ambient air quality monitoring per ISO 17025-aligned laboratory practices and compatible with GLP data integrity workflows |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KD11 |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM™-style piezoelectric resonant frequency shift) |
| Safety Rating | Non-explosion-proof |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% of reading |
| Relative Error | ≤ ±2% |
| Data Storage Capacity | 500 records |
| Communication Interface | RS-232C |
| Configurable Sampling Interval | 10–3600 seconds (preset options: 24 s, 120 s) |
| Cleaning Alert | Auto-notification upon crystal mass loading threshold exceedance |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3443+ |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | 0.1–10 µm |
| Measurement Range | 0.001–10.000 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Data Storage Capacity | 100,000 records |
| Communication Interface | USB |
| Analog Output | 0–1000 CPM / 0–1 V |
| Dimensions | 162 mm (W) × 60 mm (D) × 109 mm (H) |
| Weight | Approx. 1.3 kg (including rechargeable battery) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3443 |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | 0.1–10 µm |
| Measurement Range | 0.001–10.000 mg/m³ |
| Data Storage Capacity | 100,000 records |
| Communication Interface | USB |
| Analog Output | 0–1 V (corresponding to 0–1,000 CPM or 0–10,000 CPM) |
| Dimensions | 162 mm (W) × 60 mm (D) × 109 mm (H) |
| Weight | Approx. 1.3 kg (including rechargeable battery) |
| Safety Classification | Non-explosion-proof |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | KD11 |
| Operating Principle | Tapered Element Oscillating Microbalance (TEOM™-style microgravimetric method) |
| Safety Rating | Non-explosion-proof |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% of reading |
| Relative Error | ≤ ±2% |
| Data Storage Capacity | 500 records |
| Communication Interface | RS-232C |
| Sampling Duration Options | Fixed modes (24 s, 120 s) or user-defined (10–3600 s) |
| Maintenance Alert | Automatic crystal contamination warning |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3443 |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | 0.1–10 µm |
| Measurement Range | 0.001–10.000 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Data Storage Capacity | 100,000 records |
| Communication Interface | USB |
| Analog Output | 0–1 V (corresponding to 0–1,000 CPM or 0–10,000 CPM) |
| Dimensions | 162 mm (W) × 60 mm (D) × 109 mm (H) |
| Weight | Approx. 1.3 kg (including rechargeable battery) |
| Safety Classification | Non-explosion-proof |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | SDM-II |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Sampling Flow Rate | 1.7 L/min |
| Detection Principle | Laser Scattering (90° Forward Light Scattering) |
| Safety Rating | Non-Explosive |
| Communication Interface | RS485 |
| Zero & Span Auto-Calibration | Yes |
| Alarm Threshold Setting | Yes |
| Built-in Dehumidification | Yes |
| Filter Membrane Sampling Module | Included |
| Compliance | ISO 12103-1 A2 Fine Test Dust Compatible, Meets JIS B 7960 for Optical Dust Monitors |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KD11 |
| Measurement Principle | Piezoelectric Microbalance (PMB) |
| Particle Size Range | 0.1–10 µm (PM10), 0.1–2.5 µm (PM2.5) |
| Measurement Range | 0.01–10.00 mg/m³ |
| Sampling Flow Rate | 1.0 L/min |
| Data Storage Capacity | 500 measurement records |
| Communication Interface | RS-232C |
| Power Supply | Rechargeable Ni-MH battery / AC adapter (100–240 V AC) |
| Operating Time | ~4.5 h (fully charged) |
| Charging Time | 5–8 h |
| Dimensions | 65 × 182 × 150 mm (W × L × H) |
| Weight | ~1.75 kg |
| Safety Classification | Non-explosion-proof |
| Compliance | Designed for indoor/outdoor ambient air monitoring per ISO 7708, EN 481, and JIS Z 8901 dust classification frameworks |