Empowering Scientific Discovery

Shenyang Keye Scientific Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKANOMAX
OriginJapan
ModelKANOMAX 3443
Measurement PrincipleOptical Light Scattering
Particle Size Range0.1–10 µm
Resolution0.01 mg/m³
Accuracy±10%
Relative Error≤±2%
Data Storage Capacity500 records
Sampling IntervalConfigurable from 10 to 3600 seconds (default options: 24 s, 120 s)
Communication InterfaceRS-232C
Safety ClassificationNon-explosion-proof
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKANOMAX
OriginJapan
ModelSDM-II+
Measurement PrincipleLaser Light Scattering
Particle Size RangePM2.5, PM10, TSP
Measurement Range0.01–10.00 mg/m³
Resolution0.01 mg/m³
Accuracy±10%
Relative Error≤±2%
Sampling Flow Rate1.7 L/min
Zero & Span Auto-CalibrationYes
Humidity CompensationIntegrated Automatic Dehumidification
Alarm Threshold SettingConfigurable Concentration Limit
Communication InterfaceRS485
Power SupplyDC 10–15 V, 2 A
Dimensions (W×H×D)250 × 350 × 170 mm (unit only)
Weight~4.5 kg (unit only)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKANOMAX
OriginJapan
ModelKD11
Measurement PrinciplePiezoelectric Microbalance (QCM)
Particle Size Range0.1–10 µm (PM10), 0.1–2.5 µm (PM2.5)
Concentration Range0.01–10.00 mg/m³
Flow Rate1.0 L/min
Data Storage Capacity500 measurement records
Sampling DurationFixed modes (24 s, 120 s) or user-defined (10–3600 s)
Communication InterfaceRS-232C
Power SupplyRechargeable Ni-MH battery / AC adapter (100–240 V AC)
Battery Life~4.5 h continuous operation
Charging Time5–8 h
Dimensions (W×L×H)65 × 182 × 150 mm
Weight~1.75 kg
Auto-Cleaning AlertYes (triggered upon crystal mass loading threshold exceedance)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
Model3443
Measurement PrincipleLaser Light Scattering
Particle Size Range0.1–10 μm
Measurement Range0.001–10.000 mg/m³
Resolution0.01 mg/m³
Accuracy±10%
Relative Error≤±2%
Data Storage Capacity100,000 records
Communication InterfaceUSB
Analog Output0–1000 CPM / 0–1 V
Dimensions162 mm (W) × 60 mm (D) × 109 mm (H)
WeightApprox. 1.3 kg (including rechargeable battery)
Safety ClassificationNon-explosion-proof
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
ModelKD11
Operating PrincipleTapered Element Oscillating Microbalance (TEOM™-style piezoelectric resonant frequency shift)
Measurement Range0.01–10.00 mg/m³
Resolution0.01 mg/m³
Accuracy±10% of reading
Relative Error≤±2%
Particle Size Range0.1–10 µm (PM₁₀ mode)
Sample Flow Rate1.0 L/min
Data Storage Capacity500 measurement records
Communication InterfaceRS-232C
Power SupplyRechargeable Ni-MH battery or AC adapter (100–240 V AC)
Battery Life~4.5 hours continuous operation
Charging Time5–8 hours
Dimensions65 × 182 × 150 mm (W × L × H)
Weight~1.75 kg
Safety ClassificationNon-explosion-proof
ComplianceDesigned for occupational hygiene and environmental monitoring per ISO 7708, ISO/IEC 17025-aligned operational practices, and compatible with OSHA/NIOSH PM sampling protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
ModelSDM-II
Measurement PrincipleLaser Light Scattering
Particle Size RangePM2.5, PM10, TSP
Measurement Range0.001–30.000 mg/m³
Resolution0.01 mg/m³
Accuracy±10%
Relative Error≤±2%
Sampling Flow Rate1.7 L/min
Zero & Span Auto-CalibrationYes
Alarm Threshold SettingYes
Automatic DehumidificationYes
Communication InterfaceRS485
Power SupplyDC 10–15 V, 2 A
Dimensions (w/o case)250 × 350 × 170 mm
Weight (w/o case)~4.5 kg
Weight (with case)~8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
Model3443
Measurement PrincipleLaser Light Scattering
Particle Size Range0.1–10 µm
Concentration Range0.001–10.000 mg/m³
Data Storage Capacity100,000 records
Communication InterfaceUSB
Analog Output0–1 V (corresponding to 0–1000 CPM or 0–10,000 CPM)
Dimensions162 mm (W) × 60 mm (D) × 109 mm (H)
WeightApprox. 1.3 kg (including rechargeable battery)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
Model3443
Measurement PrincipleLaser Light Scattering
Particle Size Range0.1–10 μm
Measurement Range0.001–10.000 mg/m³
Resolution0.01 mg/m³
Accuracy±10%
Relative Error≤±2%
Data Storage Capacity100,000 records
Communication InterfaceUSB
Analog Output0–1 V corresponding to 0–1000 CPM or 0–10,000 CPM
Dimensions162 mm (W) × 60 mm (D) × 109 mm (H)
WeightApprox. 1.3 kg (including rechargeable battery)
Safety ClassificationNon-explosion-proof
ComplianceMeets China’s Ministry of Health PM₁₀ monitoring requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
ModelSXYC-508
Measurement Range0.01–10.00 mg/m³
Resolution0.01 mg/m³
Accuracy±10%
Relative Error≤±2%
Safety ClassificationNon-explosion-proof
Compliance StandardHJ/T 212–2005
Detection PrincipleBeta-ray attenuation (integrated gravimetric reference via filter sampling)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelKanomax SXYC-508
Operating PrincipleOptical Scattering (β-ray attenuation & integrated gravimetric verification)
Safety RatingNon-explosion-proof
Dust Measurement Range0.01–10.00 mg/m³
Resolution0.01 mg/m³
Accuracy±10%
Relative Error≤±2%
Noise Range30–130 dB(A)
Noise Accuracy±0.5 dB
Atmospheric Pressure Range10–1100 hPa
Pressure Accuracy±0.3 hPa
Wind Speed Range0.00–70.0 m/s
Wind Speed Accuracy±0.03 m/s
Wind Direction Range0–360°
Direction Accuracy±0.5°
Temperature Range−50–100°C
Humidity Range0–100% RH
Temp/Humidity Accuracy±0.5°C / ±3% RH
Power Consumption30 W
Power SupplyAC 220 V ±10% with backup battery (≥6 h runtime)
Data Protocol ComplianceHJ/T 212–2005
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKANOMAX
OriginJapan
Model3443
Measurement PrincipleOptical Light Scattering (90° detection geometry)
Particle Size Range0.1–10 μm
Resolution0.01 mg/m³
Accuracy±10% of reading
Relative Error≤ ±2%
Sampling DurationProgrammable from 10 to 3600 seconds (preset modes: 24 s and 120 s)
Data Storage Capacity500 records
Communication InterfaceRS-232C compliant
Safety ClassificationNon-explosion-proof
ComplianceDesigned for indoor/outdoor ambient air quality monitoring per ISO 17025-aligned laboratory practices and compatible with GLP data integrity workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
ModelKD11
Measurement PrincipleTapered Element Oscillating Microbalance (TEOM™-style piezoelectric resonant frequency shift)
Safety RatingNon-explosion-proof
Measurement Range0.01–10.00 mg/m³
Resolution0.01 mg/m³
Accuracy±10% of reading
Relative Error≤ ±2%
Data Storage Capacity500 records
Communication InterfaceRS-232C
Configurable Sampling Interval10–3600 seconds (preset options: 24 s, 120 s)
Cleaning AlertAuto-notification upon crystal mass loading threshold exceedance
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
Model3443+
Measurement PrincipleLaser Light Scattering
Particle Size Range0.1–10 µm
Measurement Range0.001–10.000 mg/m³
Resolution0.01 mg/m³
Accuracy±10%
Relative Error≤±2%
Data Storage Capacity100,000 records
Communication InterfaceUSB
Analog Output0–1000 CPM / 0–1 V
Dimensions162 mm (W) × 60 mm (D) × 109 mm (H)
WeightApprox. 1.3 kg (including rechargeable battery)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
Model3443
Measurement PrincipleLaser Light Scattering
Particle Size Range0.1–10 µm
Measurement Range0.001–10.000 mg/m³
Data Storage Capacity100,000 records
Communication InterfaceUSB
Analog Output0–1 V (corresponding to 0–1,000 CPM or 0–10,000 CPM)
Dimensions162 mm (W) × 60 mm (D) × 109 mm (H)
WeightApprox. 1.3 kg (including rechargeable battery)
Safety ClassificationNon-explosion-proof
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKANOMAX
OriginJapan
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelKD11
Operating PrincipleTapered Element Oscillating Microbalance (TEOM™-style microgravimetric method)
Safety RatingNon-explosion-proof
Measurement Range0.01–10.00 mg/m³
Resolution0.01 mg/m³
Accuracy±10% of reading
Relative Error≤ ±2%
Data Storage Capacity500 records
Communication InterfaceRS-232C
Sampling Duration OptionsFixed modes (24 s, 120 s) or user-defined (10–3600 s)
Maintenance AlertAutomatic crystal contamination warning
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKANOMAX
OriginJapan
Model3443
Measurement PrincipleLaser Light Scattering
Particle Size Range0.1–10 µm
Measurement Range0.001–10.000 mg/m³
Resolution0.01 mg/m³
Accuracy±10%
Relative Error≤±2%
Data Storage Capacity100,000 records
Communication InterfaceUSB
Analog Output0–1 V (corresponding to 0–1,000 CPM or 0–10,000 CPM)
Dimensions162 mm (W) × 60 mm (D) × 109 mm (H)
WeightApprox. 1.3 kg (including rechargeable battery)
Safety ClassificationNon-explosion-proof
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
ModelSDM-II
Measurement Range0.01–10.00 mg/m³
Resolution0.01 mg/m³
Accuracy±10%
Relative Error≤±2%
Sampling Flow Rate1.7 L/min
Detection PrincipleLaser Scattering (90° Forward Light Scattering)
Safety RatingNon-Explosive
Communication InterfaceRS485
Zero & Span Auto-CalibrationYes
Alarm Threshold SettingYes
Built-in DehumidificationYes
Filter Membrane Sampling ModuleIncluded
ComplianceISO 12103-1 A2 Fine Test Dust Compatible, Meets JIS B 7960 for Optical Dust Monitors
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKanomax
OriginJapan
ModelKD11
Measurement PrinciplePiezoelectric Microbalance (PMB)
Particle Size Range0.1–10 µm (PM10), 0.1–2.5 µm (PM2.5)
Measurement Range0.01–10.00 mg/m³
Sampling Flow Rate1.0 L/min
Data Storage Capacity500 measurement records
Communication InterfaceRS-232C
Power SupplyRechargeable Ni-MH battery / AC adapter (100–240 V AC)
Operating Time~4.5 h (fully charged)
Charging Time5–8 h
Dimensions65 × 182 × 150 mm (W × L × H)
Weight~1.75 kg
Safety ClassificationNon-explosion-proof
ComplianceDesigned for indoor/outdoor ambient air monitoring per ISO 7708, EN 481, and JIS Z 8901 dust classification frameworks
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0