- All
- Favorite
- Popular
- Most rated
| Brand | Xianxinda |
|---|---|
| Model | CIT-3000F |
| Detector Type | Gamma Spectrometer |
| Scintillator | NaI(Tl), Ø75 mm × 75 mm |
| Shielding | Lead chamber, 100 mm wall thickness, 200 mm internal diameter |
| MCA Channels | 1024 / 2048 |
| Energy Resolution | <7% at 661 keV (¹³⁷Cs) |
| Differential Nonlinearity | 0.2% |
| Integral Nonlinearity | 0.01% |
| Pulse Shaping Time | 2.0 µs |
| Background Count Rate | ≤6 cps (50–3000 keV) |
| Measurement Uncertainty | ≤10% (k=2) |
| Stability | Peak shift ≤1% over 24 h |
| Sample Mass | 500 g |
| Acquisition Time Range | 10–65,500 s |
| Operating Temperature | 0–50 °C |
| Relative Humidity | ≤95% |
| Power Consumption | <300 mA |
| Host Dimensions | 31 × 32 × 13 cm |
| Host Weight | 3 kg |
| Software | Windows-based spectral analysis suite with Chinese GUI, Excel export, calibration database, and inverse matrix quantification algorithm |
| Compliance | JJG 417–2006, GB 6566–2010, CNAS-accredited calibration certificate issued by China National Institute of Metrology (CNIM) |
| Brand | Sichuan Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | CIT-4200 |
| Pricing | Upon Request |
| Brand | Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SMQ |
| Element Range | Na (11)–U (92) |
| Concentration Range | 1 ppm – 99.99% |
| Energy Resolution | ≤125 eV (Mn Kα) |
| Repeatability | ≤0.1% RSD |
| Operating Voltage | 0–25 kV |
| Tube Current | 1–1000 µA |
| Measurement Time | 60–120 s per sample |
| Vacuum Capability | Yes |
| Detector | Peltier-cooled Si-PIN semiconductor |
| Energy Range | 1–30 keV |
| Simultaneous Elements | Up to 9 |
| Sample Mass | 10–15 g |
| Radiation Dose Rate | <25 µSv/h |
| Ambient Temp. | 10–35 °C |
| Humidity | 30–70% RH |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Brand | Xinxianda |
|---|---|
| Model | CIT-3000SYE |
| Origin | Sichuan, China |
| Detector Energy Resolution | <130 eV |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Detection Limit | 1 ppm |
| Analysis Time | 120 s (auto-optimized) |
| Operating Voltage | 0–40 kV |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions | 740 × 450 × 430 mm |
| Weight | ~55 kg |
| Sample Chamber | Ø300 × 100 mm (downward illumination) |
| Vacuum Capability | Yes |
| Software | Proprietary Windows-based EDXRF analysis suite with FP, empirical coefficient, and α-factor quantification methods |
| Compliance Support | ASTM E1621, ISO 8256, IEC 62321-5 for RoHS, GLP-ready audit trail & user access control |
| Brand | Sichuan Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SMG |
| Element Range | Na (11)–U (92) |
| Detection Limit | 0.1 ppm |
| Quantification Range | 0.1 ppm–99.99% |
| Energy Resolution | <100 eV (@5.89 keV) |
| Repeatability (RSD) | ≤0.05% |
| Detector | FAST SDD (Silicon Drift Detector) |
| Sample Chamber | Top-illumination geometry with vacuum capability (10⁻²–10⁻⁵ Pa) |
| X-ray Tube | 0–50 kV, 1–1000 µA |
| Measurement Time | 100–300 s |
| Sample Mass | 3–8 g |
| Dimensions | 750 × 670 × 1620 mm (D×W×H) |
| Weight | 135 kg |
| Compliance | GBZ 115–2002, registered with Ministry of Ecology and Environment of PRC |
| Brand | Xinxianda |
|---|---|
| Model | CIT-3000SMP |
| Detector | Si(Li) semiconductor, energy resolution ≤150 eV (at 5.9 keV, ⁵⁵Fe) |
| Excitation Source | Miniature air-cooled X-ray tube |
| Measurable Elements | S, P, Ca, Ti, V, Mn, Fe, Ni, Cu, Zn, Mo, As, Sn, W |
| Detection Range | 0.001–99.99 wt% |
| Measurement Time | <200 s |
| Operating Voltage Range | 2–30 keV |
| Power Consumption | 4 W |
| Weight | 1.75 kg |
| Battery Life | ≥8 h (full-load operation) |
| Data Interface | Bluetooth, GPS, USB |
| Safety Indicators | Dual-color LED (green = power on |
| Compliance | CE, RoHS, IEC 61010-1, IEC 62471 |
| Brand | Sichuan Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-2000SMP |
| Detector Type | Proportional Counter |
| Excitation Source | ²³⁸Pu Radioisotope |
| Energy Resolution | 15–20% (at 5.9 keV) |
| Detection Limit | 10⁻³ µg/g |
| Measurement Time | 0.5–5 min per sample |
| Operating Temperature | 0–50 °C |
| Power Consumption | ≤5 W |
| Weight | 3 kg |
| Dimensions | 30 × 20 × 13 cm |
| Elemental Range | Ca, Fe, Ti, Mn, Cu, Pb, Zn, Ni, Sn, Bi, Mo |
| Multichannel Analyzer | 512-channel |
| Sample Form | Solid (bulk or powder) |
| Compliance | CE-marked for field-deployable instrumentation |
| Software Interface | Standalone microcontroller with LCD display and onboard data storage |
| Brand | Sichuan Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SMP |
| Detector | Si(Li) semiconductor, Peltier-cooled |
| Energy Resolution | ≤150 eV (Mn Kα, 5.9 keV) |
| Analytical Range | 2–30 keV |
| Elements Analyzed | S to U (Z = 16–92) |
| Detection Limits | Cd/Cr/Hg/Br ≤ 1 ppm, Pb ≤ 2 ppm |
| Precision | RSD ≤ 0.08% (standard deviation) |
| Measurement Time | < 200 s |
| Power Consumption | 4 W |
| Weight | 1.75 kg |
| Battery Life | ≥ 8 h (full-load operation) |
| Operating System | Embedded Chinese GUI on integrated PDA |
| Connectivity | Bluetooth v4.0, GPS module |
| Safety Indicators | Dual-color LED (green = power on, red = X-ray emission) |
| Sample Forms | Solid blocks, powders, pressed pellets |
| Compliance | IEC 61010-1, IEC 62471 (LED safety), RoHS-compliant construction |
| Data Storage | Internal flash memory (≥ 16 GB) |
| Brand | Sichuan Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SYB |
| Detector | Si(PIN) Semiconductor (Cryogenically Cooled) |
| X-ray Tube | 40 kV Tungsten Target Microfocus Source |
| Energy Resolution | <150 eV @ Mn Kα |
| Analytical Range | Na (11) to U (92) |
| LOD | Cd/Cr/Hg/Br ≤1 ppm, Pb ≤2 ppm, Cl ≤20 ppm |
| Measurement Range | 1–40 keV |
| High Voltage | 0–40 kV |
| Tube Current | 0–100 µA |
| Sample Chamber | Vacuum-Compatible Circular Cavity (Ø140 mm × H50 mm) |
| Measurement Time | 120–600 s |
| Power Supply | AC 220 V ±1%, 50 Hz, 1000 VA |
| Dimensions | 500 × 500 × 450 mm |
| Weight | 25 kg |
| Operating Temp. | 0–35 °C |
| Relative Humidity | ≤99% RH (non-condensing) |
| Rated Power | 50 W |
| Calibration Standard | Certified EU RoHS Reference Materials |
| Brand | Sichuan Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | L Boundary Density Meter |
| Pricing | Upon Request |
| Brand | Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SY |
| Form Factor | Benchtop/Floor-standing |
| Application Domain | Geological & Petrological Core Logging |
| Elemental Range | Na–U |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | ≤100 eV (at Mn Kα, 5.9 keV) |
| Repeatability | RSD ≤0.05% (major elements, n=5) |
| Brand | Xinxianda |
|---|---|
| Model | CIT-2000F |
| Instrument Type | Gamma Spectrometer |
| Detector | 50 mm × 50 mm NaI(Tl) Scintillation Crystal |
| Energy Range | < 4 MeV |
| Energy Resolution | < 8% @ 662 keV (¹³⁷Cs) |
| Dose Rate Range | 0–9999 µSv/h (Environmental Monitoring) / 0–9999 γ (Uranium Exploration) |
| Sensitivity | ≥350 cps per µSv/h |
| Stability | ≤±7% over 8 h operation |
| Accuracy | Absorbed Dose Rate Deviation ≤±10% vs. Theoretical Value |
| Operating Temperature | –10°C to +50°C |
| Relative Humidity | ≤95% RH |
| Dimensions | 360 mm × 90 mm × 220 mm |
| Weight | 2.0 kg |
| Power Consumption | <160 mW |
| ADC | 16-bit, 1 MSPS |
| Data Storage | Up to 2 million spectral records |
| Measurement Modes | Timed & Manual |
| Display Units | µSv/h, γ, µSv, CPS, ppm, % |
| Housing | Anodized Aluminum Alloy |
| Battery | Rechargeable Li-ion with Low-Voltage Warning |
| Brand | Sichuan Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SM |
| Form Factor | Benchtop/Floor-Standing |
| Instrument Type | Conventional ED-XRF |
| Application Scope | Universal (Industrial & Laboratory) |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Quantification Range | 1 ppm – 99.99% (matrix-dependent) |
| Energy Resolution | < 110 eV (with SDD or FAST-SDD detector) |
| Repeatability (RSD) | < 0.1% |
| Detector | Silicon Drift Detector (SDD) or FAST-SDD |
| High Voltage Supply | 0–50 kV (adjustable), 0–1 mA (adjustable) |
| Measurement Time | 100–300 s |
| Sample Mass | 3–8 g |
| Vacuum Level | ≤ 10⁻² Pa (stable for ≥30 min) |
| Dimensions | 480 × 420 × 660 mm (D×W×H) |
| Weight | 70 kg |
| Brand | Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SME |
| Element Range | Na (11) – U (92) |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | 100 eV (at Mn Kα) |
| Repeatability | ≤0.1% RSD |
| Detector | Silicon Drift Detector (SDD), Peltier-cooled |
| Excitation Source | Ag-anode microfocus X-ray tube, Be window (50 µm), 0–50 kV / 1–1000 µA adjustable |
| Measurement Atmosphere | Air or vacuum (down to 10⁻² Pa) |
| Sample Form | Powdered solids |
| Multi-channel Analyzer | 2048-channel digital MCA |
| Simultaneous Elements | ≥30 |
| Analysis Time | 60–180 s per sample |
| Dimensions | 650 × 600 × 730 mm |
| Weight | 65 kg |
| Brand | Xinxianda |
|---|---|
| Model | CIT-3000F |
| Detector | Ø75 mm × 75 mm NaI(Tl) crystal |
| Energy Resolution | ≤8% at 662 keV (¹³⁷Cs) |
| Uranium (eU) Range | 2–1000 ppm |
| Thorium (eTh) Range | 3–1000 ppm |
| Potassium (eK) Range | 0.5–100 wt% |
| U Channel | 1.60–1.90 MeV |
| Th Channel | 2.40–3.00 MeV |
| K Channel | 1.30–1.60 MeV |
| Total Spectrum | 0.5–3.00 MeV |
| Accuracy | eU/eTh ≤ ±7%, eK ≤ ±12% |
| Pulse Shaping Time | 2 µs |
| Data Storage | 2 million spectra |
| Power | Rechargeable 2.4 Ah Li-ion battery, ≤200 mW |
| Operating Temp | 0–50 °C |
| Relative Humidity | ≤90% at 50 °C |
| Weight | Control Unit 0.6 kg, Detector 3.0 kg |
| Interface | RS-232 |
| Brand | NewSenda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3800 HPGe |
| Instrument Type | Laboratory Gamma-Ray Spectrometer |
| Detector Type | High-Purity Germanium (HPGe) |
| Measurement Range | 5 keV – 10 MeV |
| Energy Resolution | ≤1.8 keV FWHM at 1.332 MeV (⁶⁰Co) |
| Peak Area Precision | <3% RSD (0–50,000 cps) |
| Sample Form | Solid |
| Cooling Method | Liquid Nitrogen or Electromechanical Cryocooler |
| Shielding | Low-Background Lead Castle (≥10 cm Pb + Cu/Cd liners) |
| Digitization | Digital Pulse Processing (DPP) with 14-bit ADC, 100 MS/s sampling |
| Brand | Xinxianda |
|---|---|
| Model | KJD-2000R |
| Detection Principle | Electrostatic Collection + Alpha Spectrometry |
| Radionuclides | ²²²Rn and ²²⁰Rn |
| Measurement Range | 3.7–925,000 Bq/m³ (0.1–25,000 pCi/L) |
| Detection Sensitivity | 0.2 CPM/pCi/L |
| Pump Flow Rate | 1 L/min |
| Measurement Duration | 10 min (soil), 60 min (air or water) |
| Uncertainty | ≤10% (k=2) |
| Data Storage | 1,000 alpha spectra |
| Power Supply | 12 V/7 Ah rechargeable battery (≥10 h operation) or AC 220 V |
| Operating Environment | 0–50 °C, ≤95% RH |
| Dimensions | 300 × 200 × 180 mm |
| Weight | 5 kg |
| Detector Type | Passivated implanted planar silicon (PIPS) alpha spectrometer with gold-silicon surface barrier configuration |
| Calibration Sources | Certified radon chamber or liquid ²²⁶Ra standard |
| Brand | Xianxian Da |
|---|---|
| Model | CIT-3000DPP |
| Detector Type | Scintillation-based Gamma Spectrometer |
| Crystal | NaI(Tl), Φ50 mm × 50 mm (optional Φ75 mm × 75 mm) |
| Energy Resolution | ≤6.5% FWHM at 662 keV (¹³⁷Cs) |
| ADC Sampling Rate | 20–80 MS/s |
| Pulse Shaping Time | 1–5 µs |
| MCA Channels | 256–4096 |
| Differential Nonlinearity | <0.1% |
| Integral Nonlinearity | <0.01% |
| Programmable Gain | 1–4095 steps |
| Digital Pulse Processing (DPP) | Threshold-free acquisition architecture |
| Communication Interfaces | CAN, RS-232, USB 2.0, TCP/IP |
| Power Consumption | <1 W |
| Operating Temperature Range | –10 °C to +50 °C |
| Compliance | Meets IEC 61000-4 EMC standards |
| Brand | Sichuan Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SMX |
| Element Range | Na (11)–U (92) |
| Detection Range | 0.1 ppm–99.99% |
| Energy Resolution | <100 eV (@5.89 keV) |
| Repeatability (RSD) | ≤0.05% |
| Detector | FAST SDD (Silicon Drift Detector) |
| Sample Capacity | 25-position automated carousel |
| Measurement Time | 100–300 s per sample |
| Vacuum Level | 1×10⁻² Pa (stable for ≥30 min) |
| X-ray Tube | 0–50 kV, 1–1000 µA |
| Sample Mass | 3–8 g |
| Dimensions (L×W×H) | 970×750×1600 mm |
| Weight | 160 kg |
Show next