Spectrometry Instruments
Filter
Showing 91–120 of 254 results
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | MesoMR12-060H-HTHP |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Phase |
| Magnetic Field Strength | 0.3 ± 0.03 T or 0.5 ± 0.03 T |
| Sample Orientation | Transverse or Longitudinal |
| Max Sample Dimensions | Ø ≤ 25.4 mm × L ≤ 80 mm (low-temp/high-pressure mode) |
| Operating Temperature Range | Down to –20 °C |
| Pressure Capability | Compatible with high-pressure HTHP (High-Temperature High-Pressure) and LTHP (Low-Temperature High-Pressure) modules |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | MesoMR12-060H-I |
| Instrument Type | Low-Field Nuclear Magnetic Resonance (LF-NMR) Analyzer |
| Sample Compatibility | Solid-Liquid Hybrid Samples |
| Standard Temperature Range | Room Temperature to 130 °C |
| Optional Variable-Temperature Module | −100 °C to 200 °C |
| Magnet Type | Permanent Magnet |
| Nominal Field Strength | 0.5 ± 0.05 T |
| Optional Imaging Capability | Yes |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | MesoMR12-060H-I Medium-Size Pseudo-Triaxial NMR Imaging Analyzer |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Phase Samples |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.08 T (Larmor Frequency: 21.3 MHz) |
| Probe Coil Diameter | 60 mm |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | MesoMR12-60H-I |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Mode |
| Operating Frequencies | 12 MHz / 21 MHz |
| Acquisition Mode | Pulsed Fourier Transform |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.3 ± 0.03 T (12 MHz) / 0.5 ± 0.03 T (21 MHz) |
| Probe Coil Diameter | 60 mm |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | MesoMR21 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Mode |
| Operating Frequency | 21.3 MHz |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.03 T |
| Probe Coil Diameter | 60 mm |
| Optional Frequencies | 12 MHz / 21.3 MHz |
| Field Homogeneity | ≤ 10 ppm over 30 mm DSV |
| Brand | NIUMAG |
|---|---|
| Origin | Shanghai, China |
| Model | MesoMR21-040V |
| Magnet Field Strength | 0.50 ± 0.03 T |
| Operating Frequency | ~21.3 MHz (¹H) |
| Sample Orientation | Vertical (longitudinal) |
| Probe Options | 25 mm (1″), 38 mm (1.5″), and ≤10 mm diameter RF coils |
| Sample Type | Solid–liquid dual-phase (rock core, shale, porous media) |
| Instrument Class | Low-field NMR spectrometer |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MesoMR21-060H-I |
| Instrument Type | Low-Field NMR Analyzer & Imager |
| Sample Compatibility | Solid-Liquid Dual-Phase Samples |
| Operating Frequencies | 12 MHz / 23 MHz |
| Data Acquisition Mode | Pulsed Fourier Transform (PFT-NMR) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | MesoMR23-040V |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Phase Core Samples |
| Operating Frequency | 23 MHz |
| Data Acquisition Method | Pulsed Fourier Transform (PFT-NMR) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | MicroMR |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Mode |
| Operating Frequency | 20 MHz |
| Data Acquisition Mode | Pulsed Fourier Transform |
| Sample Volume | 6–10 mL |
| Oil Content Range | 0.05–100 wt% |
| Repeatability | RSD < 5% |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | MicroMR Series |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Mode |
| Operating Frequencies | 2 MHz / 12 MHz / 20 MHz |
| Acquisition Method | Pulsed Fourier Transform (PFT) |
| Standard Probe Diameter | 25.4 mm (1 inch) |
| Optional Probe | 38.1 mm (1.5 inch) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Model | MicroMR-1 |
| Sample Compatibility | Solid-Liquid Composite (Drilling Cuttings) |
| Field Strength Options | 0.3 T / 0.5 T (Configurable) |
| Probe Options | Dual Dedicated Probes (Standard & High-Sensitivity) |
| Measurement Principle | T₂ Relaxometry-Based Fluid Discrimination |
| Key Output Parameters | Oil Saturation, Water Saturation, Bound/Free Fluid Ratio, Porosity Estimate, Pore Size Distribution Index |
| Compliance Framework | Designed for GLP-aligned workflows |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MicroMR-12M |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Mode |
| Operating Frequency | 12 MHz |
| Data Acquisition Method | Pulsed Fourier Transform (PFT-NMR) |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.28 ± 0.05 T |
| Probe Coil Diameter | 25 mm |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field Nuclear Magnetic Resonance (LF-NMR) Analyzer |
| Model | MicroMR-2 |
| Sample Compatibility | Solid-Liquid Dual-Phase Samples |
| Application Domain | Petroleum Reservoir Characterization & Produced Fluid Monitoring |
| Measurement Principle | Proton (¹H) Spin Echo Relaxometry in Static Low-Field Magnetic Environment |
| Field Strength | ~0.3 T (Typical for Benchtop LF-NMR Systems) |
| RF Frequency | ~12.8 MHz (at 0.3 T) |
| T₂ Relaxation Time Range | 10 µs – 3 s |
| Data Acquisition Mode | CPMG Pulse Sequence |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MicroMR+ |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Mode |
| Operating Frequency | 12 MHz |
| Data Acquisition Method | Fourier Transform |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.28 ± 0.05 T |
| Field Homogeneity | 300 ppm (25 mm × 25 mm × 25 mm) |
| Field Stability | < 300 Hz/hour |
| RF Transmitter Power | > 300 W peak-to-peak, linearity distortion < 0.3% |
| Diffusion Gradient Strength | up to 18 G/cm (peak) |
| Standard Probe Coil Diameter | 25 mm |
| Optional Probe Coil Diameter | 10 mm |
| Effective Sample Volume | Ø25.4 mm × H25 mm |
| Power Supply | 220 V, 50 Hz |
| Operating Temperature | 22–28 °C |
| Relative Humidity | 30–70 % |
| Brand | NIUMAG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MicroMR02-025V |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase Samples |
| Magnet Type | Permanent Magnet |
| Static Field Strength | 0.05 ± 0.025 T |
| Field Homogeneity | 300 ppm over 25 mm × 25 mm × 35 mm |
| Field Stability | < 500 Hz/hour |
| Temperature Control Range | 25–35 °C (nonlinear precision thermostatic control), accuracy ±0.05 °C |
| RF Frequency Range | 2–30 MHz |
| Frequency Resolution | 0.1 Hz |
| RF Peak-to-Peak Output Power | >100 W, linearity distortion <0.3% |
| Probe Coil Diameter | 25 mm |
| Effective Sample Volume | Ø25.4 mm × H35 mm |
| Power Supply | 220 V, 50 Hz |
| Operating Ambient | 22–28 °C, 30–70% RH |
| Dimensions (L×W×H) | Magnet Cabinet: 410 × 450 × 500 mm |
| RF Cabinet | 450 × 90 × 410 mm |
| Spectrometer Unit | 425 × 177 × 480 mm |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | MicroMR06-040V-P-4 |
| Instrument Type | Low-Field Nuclear Magnetic Resonance Analyzer |
| Sample Type | Solid-Liquid Dual-Mode |
| Magnet Type | Permanent Magnet |
| Larmor Frequency | 6.17 MHz ± 0.2 MHz |
| Sample Cavity Dimensions | 550 mm (L) × 550 mm (D) × 700 mm (H) |
| Homogeneous Zone | Ø38.1 mm × H80 mm |
| Maximum Sample Length | 1.5 inches (38.1 mm) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual Mode |
| Magnet Type | Permanent Magnet |
| Operating Frequency | 6.17 MHz ± 0.2 MHz |
| Sample Cavity Dimensions | 550 mm (L) × 550 mm (D) × 700 mm (H) |
| Homogeneity Zone | Ø38.1 mm × H80 mm |
| Max Sample Size | 1.5-inch rock core |
| Key Applications | Porosity, Permeability, Fluid Saturation, Movable Fluid Saturation, Pore Size Distribution, T₁–T₂ & D–T₂ 2D NMR Spectroscopy |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | MicroMR06-040V-P-2 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Mode |
| Magnet Type | Permanent Magnet |
| Larmor Frequency | 6.17 MHz ± 0.2 MHz |
| Sample Cavity Dimensions | 550 mm (L) × 550 mm (D) × 700 mm (H) |
| Homogeneity Region | Ø38.1 mm × H80 mm |
| Max Core Diameter | 1.5 inches |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Mode |
| Magnet Type | Permanent Magnet |
| Larmor Frequency | 6.17 MHz ± 0.2 MHz |
| Effective Uniform Field Region | Ø38.1 mm × H80 mm |
| Max Sample Dimension | 550 mm (L) × 550 mm (D) × 700 mm (H) |
| Application Scope | Rock Core, Cuttings, Irregular & Standard Cylindrical Samples |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | MicroMR06-040V-P2 |
| Instrument Type | Low-Field Nuclear Magnetic Resonance Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase Samples |
| Magnet Type | Permanent Magnet |
| Operating Larmor Frequency | 6.17 MHz ± 0.2 MHz |
| Sample Cavity Dimensions | 550 mm (L) × 550 mm (D) × 700 mm (H) |
| Homogeneous Zone | Ø38.1 mm × H80 mm |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MicroMR12 |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Static Magnetic Field Strength | 0.28 ± 0.05 T |
| Larmor Frequency | 12 MHz |
| Probe Coil Diameter | 25.4 mm |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MicroMR12-025V |
| Instrument Type | Low-Field NMR Analyzer |
| Operating Frequency | 12 MHz (corresponding to ~0.28 T static magnetic field) |
| Magnet Type | Permanent Magnet |
| Probe Coil Diameter | 25 mm |
| Effective Sample Volume | Ø25.4 mm × H35 mm |
| Sample Compatibility | Solid–Liquid Dual-Mode |
| Optional Upgrade | Diffusion-Weighted NMR (D-T2, D-T1-T2) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | MRCL-110 |
| Instrument Type | Low-Field Nuclear Magnetic Resonance Analyzer |
| Sample Type | Solid–Liquid Combined (Full-Diameter Rock Cores) |
| Operating Frequency | 6.2 MHz |
| Maximum Core Length | 1 m |
| Maximum Core Diameter | 115 mm |
| Minimum Longitudinal Resolution | 1 cm |
| Primary Measurements | T₁ and T₂ Relaxation Spectra, T₁–T₂ Two-Dimensional Correlation Spectroscopy |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | NM-PQ001 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase Samples |
| Magnetic Field Strength | 0.28 T ± 0.03 T |
| Sample Cavity Dimensions | Ø40 mm × H60 mm |
| Magnet Homogeneity | ≤40 ppm |
| Repeatability (11 Replicates) | ≤0.5% RSD |
| Oil Content Range | 1–100 wt% |
| Water Content Range | 2–10 wt% |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Magnet Type | Permanent Magnet |
| Field Strength | 0.5 T ± 0.03 T |
| Max Sample Dimensions | Ø68 mm × H60 mm |
| Sample Compatibility | Solid-Liquid Dual-Mode (in vivo small animals & ex vivo tissues) |
| Imaging Modes | T1-weighted, T2-weighted, Water-Fat Separation |
| Spatial Resolution | Sub-millimeter (typical in-plane resolution ≤ 0.5 mm) |
| Scan Time | ~2 minutes per standard protocol |
| Regulatory Compliance | CE-marked for research use only (RUO), compliant with ISO/IEC 17025 calibration traceability framework for NMR signal stability |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | NM21-060H-I |
| Instrument Type | Low-Field Nuclear Magnetic Resonance Imaging Analyzer |
| Sample Type | Solid-Liquid Hybrid Samples |
| Magnet Type | Permanent Magnet |
| Field Strength | 0.6 T ± 0.03 T |
| Homogeneity | ≤30 ppm over 60 mm DSV |
| Sample Weight Range | 1–350 g (mice, rats, excised tissues, contrast agents, magnetic nanoparticles) |
| Imaging Modes | T1-weighted, T2-weighted, Proton Density-weighted, Water-Fat Suppressed Imaging |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | NM42-060H-1 |
| Instrument Type | Low-Field NMR Spectrometer |
| Sample Compatibility | Solid-Liquid Hybrid (ex vivo tissues & live rodents, 1–350 g) |
| Magnet Type | Permanent Magnet |
| Field Strength | 1 T ± 0.05 T |
| Homogeneity | ≤30 ppm over DSV |
| Imaging Modes | T1-weighted, T2-weighted, Proton Density-weighted, Water-Fat Suppressed Imaging |
| Application Domain | Preclinical Metabolic Disease Research |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-060H-2 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Mode (Ex Vivo Tissues & Live Rodents, 1–350 g) |
| Magnet Type | Permanent Magnet |
| Field Strength | 1 T ± 0.05 T |
| Magnetic Homogeneity | ≤30 ppm over 60 mm DSV |
| Spatial Resolution | <100 µm (in-plane, optimized conditions) |
| Imaging Sequences | T1-weighted, T2-weighted, Proton Density-weighted, Fat-Suppressed, Diffusion-Weighted (optional) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-060H-I-1 |
| Instrument Type | Low-Field NMR Imager |
| Sample Compatibility | Solid and Liquid Samples (in vivo rodents, ex vivo tissues, contrast agents, magnetic nanoparticles) |
| Magnet Type | Permanent Magnet |
| Static Field Strength | 1.0 T ± 0.05 T |
| Magnetic Field Homogeneity | ≤30 ppm over 60 mm DSV |
| Sample Weight Range | 1–350 g (mice, rats, excised tissues) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | NM42-060H-I-2 |
| Instrument Type | Low-Field Nuclear Magnetic Resonance Imaging System |
| Sample Type | Solid-Liquid Dual Compatibility |
| Magnet Type | Permanent Magnet |
| Field Strength | 1.0 T ± 0.05 T |
| Magnet Homogeneity | ≤30 ppm over Ø60 mm DSV |
| Supported Sample Mass Range | 1–350 g (mice, rats, excised tissues) |
| RF Coil Apertures | Ø60 / Ø45 / Ø35 / Ø30 / Ø25 mm |
| Max Reconstruction Matrix | 512 × 512 × 128 |
| Integrated Anesthesia & Respiratory Monitoring | Yes |
| Temperature-Controlled Animal Bed | Yes |
| Pulse Sequence Flexibility | Graphical GUI + Python API for custom sequence development |
| Data Throughput Architecture | Gigabit Ethernet-based real-time acquisition with <10⁻⁹ bit error rate |
