- All
- Favorite
- Popular
- Most rated
| Brand | TECAN |
|---|---|
| Origin | Austria |
| Model | T48 |
| Instrument Type | Fully Automated Western Blotting System |
| Automation Level | Fully Automated |
| Sample Capacity | Up to 48 samples per run |
| Incubation Temperature Control | Peltier-based active heating and cooling (range: 4–65 °C) |
| Wash Throughput | Simultaneous processing of up to 3 membrane strips |
| Reagent Delivery | Precision peristaltic pumps with auto-calibration |
| Waste Management | Dual-channel segregated waste collection (hazardous & biohazard) |
| Software | Blotware™ v5.x with audit trail, user access levels, and protocol scheduling |
| Compliance | Designed for GLP/GMP environments |
| Brand | Tecan Cavro |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Cavro Mini Sample Processor (MSP) |
| Quotation | Upon Request |
| Deck Configuration | User-Defined |
| Pipetting Accuracy | <1% CV |
| Pipetting Range | 1 µL – 50 mL |
| Sample Throughput | User-Defined |
| Dimensions (L×W×H) | 559 mm × 600 mm × 522 mm |
| Brand | Tecan |
|---|---|
| Origin | Switzerland |
| Model | D300e |
| Instrument Type | Digital Microfluidic Dispenser |
| Automation Level | Motorized, Software-Controlled |
| Primary Technology | Acoustic Droplet Ejection (ADE) |
| Minimum Dispense Volume | 10 pL (picoliter) |
| Dispense Precision | CV < 5% at ≥ 50 pL |
| Throughput | Up to 1,200 dispenses per second |
| Compatibility | 96-, 384-, and 1536-well plates |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | TECAN |
|---|---|
| Origin | Austria |
| Model | HYDROFLEX™ |
| Instrument Type | Multifunctional Plate Washer |
| Application Scope | ELISA, Magnetic Bead-Based Assays, Vacuum Filtration, Adherent Cell Washing, Protein Microarray Processing |
| Control Options | Integrated Keypad & PC Software (HydroFlex Control Software) |
| Design Architecture | Modular |
| Liquid Handling Principle | Multi-point Aspiration, Drop-wise Dispensing |
| Vacuum System | Integrated Pressure-Sensing Vacuum Pump |
| Compliance Context | Designed to support GLP-compliant workflows |
| Brand | TECAN |
|---|---|
| Origin | Switzerland |
| Model | Freedom EVO® & Atoll MediaScout® |
| Configuration | Integrated Liquid Handling Platform with RoboColumn™ Array for Parallel Protein Purification |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with 21 CFR Part 11–enabled software environments |
| Sample Throughput | Up to 96 parallel protein purification runs per cycle |
| Minimum Fraction Volume | 25 µL |
| Column Format | SBS-standard 96-well footprint RoboColumn™ array (MiniColumn inner diameter: 5 mm |
| resin bed heights | 2.5 / 5 / 10 / 30 mm |
| corresponding resin volumes | 50 / 100 / 200 / 600 µL) |
| Flow Control Precision | Down to 16.2 cm/h linear velocity via Dilutor pump system |
| Detection Integration | Compatible with Tecan Infinite M200 Pro and other plate readers for automated A280 quantification |
| Brand | TECAN |
|---|---|
| Origin | Austria |
| Model | HYDROSPEED™ |
| Instrument Type | Multifunctional Plate Washer |
| Regulatory Compliance | EU IVD Directive 98/79/EC, FDA 21 CFR Part 11 (via HydroControl Software) |
| Key Features | Cell Protection™ Technology, Single-Well Dual-Magnet™ Bead Recovery, Anti-Clogging™ Needle Protection System |
| Design | Onboard Touchscreen Control, Integrated Sensors for Plate Detection & Automation Readiness |
| Plate Compatibility | 96-well and 384-well microplates |
| Application Flexibility | ELISA washing, gentle cell monolayer washing, magnetic bead-based assays, vacuum filtration (optional module) |
| Brand | Tecan Cavro |
|---|---|
| Origin | Malaysia |
| Model | Cavro Smart Valve Plus |
| Valve Positions | User-Configurable (up to 20 ports) |
| Dispensing Accuracy | <1% CV |
| Dispensing Range | 1 µL – 50 mL |
| Control Interface | RS-232 / RS-485 / CAN bus |
| Power Supply | 24 VDC ±10%, 850 mA |
| Dimensions | 52.9 × 25 × 50 mm |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–95% RH (non-condensing at 40 °C) |
| Fluidic Connections | 1/4-28 UNF or M6 threaded fittings |
| Valve Head Options | 3-, 4-, 6-, 9-, and 20-port configurations |
| Compliance | Designed for integration into IVD, clinical chemistry, and GLP-compliant automated liquid handling systems |
| Brand | TECAN |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EVO75 |
| Price | Upon Request |
| Deck Positions | 12 |
| Pipetting Accuracy | Not Specified by OEM Configuration |
| Pipetting Range | 0.5–5000 µL |
| Sample Throughput | 48 samples per run |
| Dimensions (W×D×H) | 885 × 700 × 645 mm |
| Brand | Tecan Cavro |
|---|---|
| Origin | Malaysia |
| Model | SVP |
| Valve Configurations | 3-, 4-, 6-, 9-, or up to 20-port options (ceramic or polymer rotor/stator) |
| Fluidic Interface | 1/4-28 UNF or M6 threaded ports |
| Control Interface | RS-232, RS-485, CAN bus |
| Power Supply | 24 VDC ±10%, 850 mA max |
| Dimensions | 52.9 × 25 × 50 mm |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–95% RH (non-condensing at 40 °C) |
| Accuracy | <0.25% of full scale |
| Repeatability | <0.05% of full scale |
| Instrument Type | Precision Microfluidic Selector Valve for Syringe Pump Integration |
| Brand | Tecan |
|---|---|
| Origin | Austria |
| Model | Infinite F50 |
| Detection Method | Absorbance |
| Detection Technology | Photometric (LED-based) |
| Measurement Modes | Endpoint, Kinetic, Multi-Label (sequential absorbance reads) |
| Read Channels | 8-channel simultaneous detection |
| Automation Level | Semi-Automatic |
| Light Source | Long-life LED (no warm-up, no alignment required) |
| Software | Magellan v7.x with FDA 21 CFR Part 11 compliance modules |
| Regulatory Compliance | EU IVDR 2017/746 (formerly 98/79/EC IVD Directive), FDA 21 CFR Part 11 audit trail & electronic signature support |
| Vibration Control | Adjustable speed and duration |
| Optical Path Correction | Reference well normalization supported |
| Data Export | CSV, Excel, PDF, XML |
| Interface | USB 2.0, Ethernet |
| Plate Formats | 6–384-well microplates (standard footprint) |
| Brand | Tecan |
|---|---|
| Origin | Switzerland |
| Model Variants | EVOlyzer 100, EVOlyzer 150, EVOlyzer 200 |
| Deck Positions | 20 / 28 / 44 |
| Liquid Handling Range | 10–100 µL |
| Pipetting Accuracy | ±10% at 10 µL, ±2% at 100 µL, ±1.5% at 200 µL, ±1% at 1000 µL |
| Sample Throughput (per run) | 2–8 microplates |
| Dimensions (W×D×H) | 800 × 1520 × 910 mm |
| Brand | TECAN |
|---|---|
| Origin | Shanghai, China |
| Model | Freedom EVO 100 / Freedom EVO 150 |
| Deck Positions | 20 / 28 (excluding optional expansion modules) |
| Pipetting Range | 0.5–1000 µL |
| Dimensions | Model-dependent |
| Brand | TECAN |
|---|---|
| Origin | USA |
| Model | 253-1160 |
| Channel Configuration | 96-channel parallel processing |
| SPE Format | Cartridge-based (1 mL columns) and 96-well plate compatible |
| Flow Rate Control | 0.1–60 mL/min (positive-pressure driven) |
| Solvent Selection | Up to 11 independent solvent channels |
| Sample Capacity | 1–96 samples per run |
| Sample Load Volume | 0.5–100 mL per sample |
| Wetted Materials | PTFE, polypropylene (PP), stainless steel (316 SS) |
| System Footprint | Compact benchtop design |
| Brand | TECAN |
|---|---|
| Origin | Switzerland |
| Model | EVO100 + 48-Position Magnetic Bead Module |
| Deck Capacity | 20 positions |
| Liquid Handling Range | 0.5–5000 µL |
| Dimensions (W×D×H) | 1075 × 875 × 870 mm |
| Integrated Modules | Barcode Scanner, Active Reagent Cooling Module (4–12 °C), Rotating Magnetic Bead Separation Module (bidirectional vertical rotation for enhanced mixing efficiency) |
| Brand | TECAN |
|---|---|
| Origin | Switzerland |
| Model | EVO |
| Deck Positions | 20 |
| Liquid Handling Range | 0.5–5000 µL |
| Dimensions | 1075 × 875 × 870 mm |
| Application Scope | Forensic micro-volume DNA extraction and PCR setup |
| Core Technology | Magnetic bead-based nucleic acid isolation |
| Throughput | Up to 48 samples per run |
| Cycle Time | ~100 minutes |
| Integrated Modules | Te-Mags magnetic separation, incubation block, high-speed centrifuge |
| Sample Types | Whole blood, buccal swabs, saliva, semen, vaginal swabs, and other forensic biological fluids |
| Actuation | Pneumatic or liquid-driven pipetting |
| Brand | Tecan |
|---|---|
| Origin | Shanghai, China & Männedorf, Switzerland |
| Model | Fluent 480 / Fluent 780 / Fluent 1080 |
| Deck Capacity | 30 / 48 / 72 positions |
| Sample Throughput | 480 / 780 / 1080 samples per run |
| Dimensions | Not specified |
| Compliance | Designed for GLP/GMP environments |
| Brand | Tecan |
|---|---|
| Origin | Switzerland / China (Shanghai Manufacturing Site) |
| Model | Freedom EVO® |
| Pipetting Range | 0.5–5000 µL |
| Throughput Capacity | 100 / 150 / 200 samples per run |
| Dimensions (W×D×H) | 1075 mm × 780 mm × 870 mm |
| Modular Arm Options | Up to 3 robotic arms (LiHa, Air LiHa, MCA96, RoMa, Extended-Z RoMa, PnP) |
| Compliance | FDA 21 CFR Part 11 (electronic signatures), GLP/GMP-ready architecture |
| Software Platform | FluentControl™ with 3D simulation, real-time monitoring, and audit-trail-enabled workflow logging |
| Brand | TECAN |
|---|---|
| Origin | Switzerland |
| Model | Fluent NAE Workstation |
| Extraction Methods | Magnetic Bead-Based Isolation, Solid-Phase Extraction |
| Liquid Handling Technology | Air-Displacement Pipetting |
| Dynamic Range | 0.5 µL – 1,000 µL |
| Tip Type | Disposable Filter Tips |
| Throughput | Parallel Processing with Synchronized Dual-Arm Motion |
| Sample Tracking | Integrated 2D Barcode Scanner and Optional RFID Reader |
| Module Flexibility | Configurable with Shaking, Vacuum Filtration, and Magnetic Separation Modules |
| Safety Features | Real-Time Aspiration/Dispense Monitoring, Clog Detection, Tip Presence Verification |
| Brand | Tecan |
|---|---|
| Origin | Switzerland |
| Model | Fluent 780 / Fluent 1080 |
| Deck Capacity | 30 / 48 / 72 positions (excluding expandable deck modules) |
| Pipetting Range | 0.5–1000 µL |
| Dimensions | Model-specific |
| Compliance | Designed for GLP/GMP-aligned biobanking workflows, supports 21 CFR Part 11 audit trail requirements via FluentControl™ software |
| Brand | Tecan Cavro |
|---|---|
| Origin | Malaysia |
| Model | Cavro ADP 2 |
| Instrument Type | Micro-syringe Pump |
| Dispensing Range | 5–1000 µL |
| Minimum Increment | 25 nL per step (40,000 steps for 1000 µL) |
| Tip Compatibility | Tecan LiHa disposable tips (10, 50, 200, 1000 µL |
| Liquid Level Detection | Capacitive and pressure-based |
| Communication Interface | RS485 / CAN bus |
| Integrated Diagnostic Algorithms | Bubble detection, clot detection, air aspiration, insufficient liquid volume |
| Tip Handling | Automated tip pickup/ejection with real-time tip status monitoring |
| Cross-contamination | Eliminated via single-use tip architecture |
| Brand | Tecan |
|---|---|
| Origin | Austria |
| Model | Spark Cyto |
| Automation Level | Fully Automated |
| Detection Modes | Fluorescence Imaging, Brightfield, Multimode Plate Reading (Absorbance, Fluorescence Intensity, Luminescence, Time-Resolved Fluorescence, FRET) |
| Imaging Capabilities | Widefield Epifluorescence, Full-Well Capture per Field, Z-Stacking, Kinetic Time-Lapse, 2D & 3D Cell Culture Compatibility |
| Objectives | 2×, 4×, 10× (Motorized, Auto-Focus Enabled) |
| Fluorescence Channels | 4 Independent Filter Sets (Configurable) |
| Software Platform | SparkControl™ MAGNA with Real-Time Experiment Control (REC), GLP-Compliant Audit Trail, FDA 21 CFR Part 11 Ready |
| Throughput Options | Standalone or Integrated with Tecan Fluent/Genesis Liquid Handling Platforms and Incubation Modules (e.g., Gas-Controlled Multi-Plate Incubator) |
| Brand | Tecan Cavro |
|---|---|
| Origin | Malaysia |
| Model | Cavro ADP |
| Instrument Type | Micro-syringe Pump |
| Flow Rate | See Product Datasheet |
| Accuracy | <0.25% of Full Scale |
| Repeatability | <0.05% of Full Scale, <0.5% at 10% of Full Scale |
| Dispense Range | <5–1000 µL |
| Step Resolution | 25 nL/step (40,000 steps for 1000 µL) |
| Cross-Contamination | Eliminated via Disposable Tips |
| Tip Handling | Fully Automated — Tip Presence Detection, Pickup & Ejection |
| Compatible Tips | Tecan LiHa Disposable Tips (10, 50, 200, 1000 µL |
| Communication Interface | RS-485 / CAN Bus |
| Brand | Tecan |
|---|---|
| Origin | Switzerland |
| Automation Level | Fully Automated |
| Platform | Freedom EVO® |
| SPE Mode | Positive Pressure (ppSPE) |
| Cartridge Compatibility | 1 mL, 3 mL, and 6 mL SPE columns |
| Maximum Throughput | 72 samples per run |
| Channel Configuration | 8-channel liquid handling arm |
| Extraction Format | Column-based SPE |
| Regulatory Alignment | Designed for GLP/GMP-compliant laboratories |
| Software Integration | FluentControl™ with audit trail and user access control |
| Compliance | Supports 21 CFR Part 11 requirements for electronic records and signatures |
| Brand | TECAN |
|---|---|
| Origin | Austria |
| Model | Spark |
| Function Type | Multimode |
| Automation Level | Fully Automated |
| Detection Modes | Absorbance (UV-Vis spectral scanning), Fluorescence Top/Bottom Read (including 3D fluorescence spectral scanning), Time-Resolved Fluorescence (TRF), TRF Spectral Scanning, Fluorescence Resonance Energy Transfer (FRET), Time-Resolved FRET (TR-FRET), Fluorescence Polarization (FP), Luminescence (Glow, Flash, Multicolor, High-Sensitivity Luminescence Spectral Scanning), AlphaScreen®/AlphaLISA®/AlphaPlex®, Real-Time Brightfield Cell Imaging (Cell Counting & Confluence Analysis) |
| Wavelength Range | 200–1000 nm |
| Additional Modules | Cuvette Port (Absorbance), NanoQuant Plate, Temperature Control (RT +3 °C to 42 °C), Integrated Liquid Handling with Heating & Stirring, CO₂ & O₂ Gas Control Module, Humidity Chamber (Volatile Compound Protection), Te-Cool™ Active Cooling (18–42 °C), Automatic Lid Lifting, Built-in QC Tools (IQ/OQ Support), Integrated Spark-Stack™ Microplate Stacker |
Show next