Thermal Desorber
Filter
Showing 121–150 of 218 results
| Brand | ColinTech |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AutoTD A |
| Instrument Type | Dual-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temperature Range | 50–400 °C |
| Secondary Desorption Temperature Range | −40–400 °C |
| Valve Injection Zone Temperature Range | 50–300 °C |
| Transfer Line Temperature Range | 50–300 °C |
| Cryo-Trap Temperature Range | −40–400 °C |
| Temperature Control Accuracy | < ±0.1 °C |
| Desorption Recovery Rate | 99.5% |
| Sample Capacity | 50 positions |
| Method Storage | 10 user-defined methods |
| Sample Recovery Function | Yes (≥90% recovery efficiency) |
| Leak Test & Moisture Purge | Automatic |
| Cap Handling | Automated cap removal and resealing |
| Optional Accessories | Electronic Pressure Control (EPC), Electronic Flow Control (EFC) |
| Brand | ColinTech |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber |
| Automation Level | Fully Automatic |
| Primary Desorption Temperature Range | 50–400 °C |
| Secondary Desorption (Cold Trap) Temperature Range | −40–400 °C |
| Valve & Transfer Line Temperature Range | 50–300 °C |
| Cold Trap Temperature Control Accuracy | < ±0.1 °C |
| Desorption Recovery Rate | 99.5% |
| Sample Capacity | 50 positions |
| Method Storage | 10 user-defined methods |
| Brand | ColinTech (Chengdu Colin Technology Co., Ltd.) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temperature Range | 50–400 °C |
| Secondary Desorption (Cold Trap) Temperature Range | −30–400 °C |
| Valve & Transfer Line Temperature Range | 50–300 °C |
| Cold Trap Temperature Range | −30–400 °C |
| Temperature Control Accuracy | < 0.1 °C |
| Desorption Recovery Rate | 99.5% |
| Sample Position Capacity | 50 positions |
| Brand | ColinTech |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | AutoTD OLS |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | −40 °C to 425 °C |
| Cold Trap Temperature Range | −40 °C |
| Desorption Recovery Rate | 92% |
| Sample Positions | 50 |
| Flow Control Range | 1–200 mL/min |
| Compatible Analyzers | GC, GC-MS |
| Water Removal | Multi-stage, patented |
| Remote Operation | Web- and mobile-enabled (optional) |
| Application Mode | Online continuous monitoring, canister/bag analysis, tube desorption |
| Brand | Fortelab |
|---|---|
| Origin | Chongqing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CP300 |
| Price Range | USD 1,400 – 7,000 (based on current exchange rate) |
| Instrument Type | Secondary Thermal Desorber, Thermal Desorption Unit |
| Brand | Fulu |
|---|---|
| Origin | Russia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TDA |
| Instrument Type | Two-Stage Thermal Desorber / Thermal Desorption Unit |
| Sample Capacity | 50-position Auto-sampler |
| Sample Tube Format | US Standard Adsorption Tubes (89 mm × OD 6.4 mm) |
| Temperature Control Range | –20 °C to 450 °C |
| Cold Trap Heating Rate | Up to 3000 °C/min |
| Carrier Gas Control | Full Electronic Pressure Control (EPC) |
| System Liner | Fully Inert Flow Path |
| Peak Area Repeatability | RSD ≤ 2% |
| Operating Interface | Integrated Touchscreen Display |
| Functional Modes | Analysis, Tube Conditioning (Aging), Cold Trap Cleaning, Cold Trap Performance Test |
| Cooling Method | Thermoelectric (No Liquid Nitrogen Required) |
| Brand | Golden Promise |
|---|---|
| Model | OG-2000V |
| Origin | Shandong, China |
| Instrument Type | Rock Pyrolysis Analyzer for Geochemical Evaluation of Source Rocks |
| Compliance | Designed for ASTM D5307 / ISO 10374 / SY/T 5115-2014 |
| Detection Principle | Controlled-Temperature Pyrolysis coupled with Flame Ionization Detection (FID) and Thermal Conductivity Detection (TCD) |
| Sample Form | Crushed core or cuttings (dry, <1 mm particle size) |
| Temperature Range | Ambient to 650 °C (programmable ramp rates) |
| Data Interface | USB 2.0 (Windows-compatible, driver-free operation) |
| Measurement Output | S1 (free hydrocarbons), S2 (kerogen-derived hydrocarbons), S3 (CO₂ from organic carbon), Tmax (peak pyrolysis temperature), HI/OI (Hydrogen Index / Oxygen Index) |
| Accuracy | ±2% FS for S1/S2 |
| Power Supply | 220 VAC, 50 Hz, 1.5 kW |
| Brand | Golden Promise |
|---|---|
| Model | OG-2000V-A |
| Detector Type | Dual Flame Ionization Detector (FID) |
| Minimum Hydrocarbon Detection | 0.001 mg HC/g rock |
| Baseline Drift | < 0.1 mV / 30 min |
| Linear Dynamic Range | 10⁶ |
| FID Temperature Control Accuracy | 360 ± 0.5 °C |
| Pyrolysis Furnace Control Accuracy | 600 ± 0.5 °C |
| Oxidation Furnace Control Accuracy | 600 ± 0.5 °C |
| Programmable Temperature Ramp Profiles | 4 (Source Rock, Reservoir Rock, Thermal Simulation, User-Defined) |
| Ramp Linearity Deviation | < 0.5 °C/min |
| Total Analysis Time (Pyrolysis + Residual Carbon) | 14.5 min |
| Data Interface | USB 2.0 |
| Software Compatibility | Windows 98/2000/XP |
| Compliance | Designed for ASTM D7260, ISO 10303-21 (AP210) data exchange conventions, GLP-compliant audit trail support via software logging |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber / Thermal Desorption Unit |
| Automation Level | Fully Automated |
| Primary Desorption Temperature Range | 100–400 °C |
| Secondary Desorption (Focusing Trap) Temperature | Up to 460 °C |
| Valve & Transfer Line Temperature Range | 50–200 °C |
| Cold Trap Temperature | −30 °C |
| Temperature Control Accuracy | ±1 °C |
| Analyte Recovery Rate | >90% |
| Sample Capacity | 24 adsorption tubes |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | APK720R |
| Instrument Type | Automated Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Valve Inlet Temperature Control Range | 50–400 °C |
| Transfer Line Temperature Control Range | Ambient to 200 °C |
| Cold Trap Temperature | −30 °C |
| Sample Capacity | 72 adsorption tubes |
| Desorption Recovery Efficiency | High |
| Cooling Mechanism | Peltier-based cryofocusing (no liquid cryogen required) |
| Compatibility | GC systems from Agilent, Thermo Fisher, Shimadzu, PerkinElmer, and others |
| Detection Sensitivity | Capable of preconcentrating VOCs from ppb to ppt levels |
| Compliance | Designed for ASTM D6196, EPA TO-14A, TO-15, TO-17, and EU ISO 16017-1 workflows |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | APK720R |
| Instrument Type | Dual-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Valve Injection Zone Temperature Range | 50–400 °C |
| Transfer Line Temperature Range | Ambient to 200 °C |
| Cold Trap Temperature Range | −30 °C |
| Sample Capacity | 72 Adsorption Tubes |
| Desorption Recovery Efficiency | High |
| Cold Trap Technology | Peltier-Cooled Focusing Trap |
| Sample Enrichment Sensitivity | ppb–ppt Level |
| Compliance | Compatible with ASTM D6196, EPA TO-14A, TO-17, and US EPA Method 320 |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | APK720R |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Valve Injection Zone Temperature Range | 50–400 °C |
| Transfer Line Temperature Range | Ambient to 200 °C |
| Cold Trap Temperature Range | −30 °C |
| Sample Capacity | 72 adsorption tubes |
| Desorption Recovery Efficiency | High |
| Cooling Mechanism | Peltier-based cryofocusing (no liquid cryogens required) |
| Compatibility | GC systems from Agilent, Thermo Fisher, Shimadzu, PerkinElmer, and others |
| Regulatory Alignment | Designed for compliance with EPA TO-14A, TO-15, ASTM D6196, ISO 16017-1, and EU EN 13670 |
| Brand | HuaSheng PuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Single-Stage Thermal Desorber |
| Desorption Temperature Range | –30 °C to 400 °C |
| Cold Trap Temperature Range | –30 °C |
| Desorption Recovery Rate | >95% |
| Sample Positions | 20 |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 350 °C |
| Secondary Desorption Temp Range | Ambient to 350 °C |
| Valve Inlet Temp Range | Ambient to 220 °C |
| Transfer Line Temp Range | Ambient to 200 °C |
| Cryo-Focusing Trap Temp Range | −30 °C to 50 °C |
| Temperature Control Accuracy | ±1 °C |
| Temperature Resolution | 1 °C |
| Sample Capacity | 30 positions |
| Desorption Recovery Rate | >98% (compound-dependent) |
| Cold Trap Cooling Rate | ≥2500 °C/min |
| Purge Flow Rate | 0–500 mL/min (continuously adjustable) |
| Dimensions | 520 × 520 × 500 mm (W × H × D) |
| Weight | ~45 kg |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Dual-Channel Low-Temperature Cryo-Trap, 40-Position |
| Automation Level | Fully Automated |
| Desorption Temperature Range | 150–380 °C |
| Valve Injection Zone Temperature Range | Ambient to 240 °C |
| Transfer Line Temperature Range | Ambient to 240 °C |
| Cryo-Trap Temperature Range | −30 to 50 °C (1 °C increments) |
| Temperature Control Accuracy | ±1 °C |
| Analyte Recovery Rate | >95% |
| Sample Capacity | 40 adsorption tubes |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Secondary Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Zone Temperature Range | Ambient to 400 °C |
| Valve Injection Zone Temperature Range | Ambient to 240 °C |
| Transfer Line Temperature Range | Ambient to 240 °C |
| Cold Trap Temperature Range | −30 °C |
| Temperature Control Accuracy | ±1 °C |
| Analyte Recovery Rate | >95% |
| Sample Capacity | 20 adsorption tubes (dual-channel configuration) |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Temperature Range | Ambient to 400 °C |
| Valve Injection Zone Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 240 °C |
| Cold Trap Temperature Range | −35 °C to Ambient |
| Temperature Control Accuracy | ±0.1 °C |
| Analyte Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | ≥10 positions |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Primary Desorption Temp Range | Ambient to 350 °C |
| Valve Inlet Temp Range | Ambient to 220 °C |
| Transfer Line Temp Range | Ambient to 200 °C |
| Cryo-Focusing Trap Temp Range | −35 °C to 50 °C |
| Temperature Control Accuracy | ±1 °C |
| Desorption Recovery Rate | >98% |
| Sample Position Capacity | 1 |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | 50–400 °C |
| Valve Injection Zone Temp Range | Ambient to 200 °C |
| Transfer Line Temp Range | Ambient to 200 °C |
| Cryo-Focusing Trap Temp Range | −35 to 50 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Desorption Recovery Efficiency | ≥98% |
| Sample Capacity | 50 positions |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Single-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Sample Zone Temperature Range | Ambient to 400 °C |
| Valve Injection System Temperature Range | Ambient to 180 °C |
| Transfer Line Temperature Range | Ambient to 200 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Desorption Recovery Rate | ≥95% |
| Sample Position Capacity | 1 |
| Dimensions | 170 × 390 × 400 mm |
| Weight | ~10 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ATDS-3600A |
| Price Range | USD 14,000 – 42,000 |
| Instrument Type | Two-Stage Thermal Desorber / Thermal Desorption Unit |
| Desorption Temperature Range | −30 °C to 400 °C |
| Cold Trap Temperature Range | −30 °C to 50 °C |
| Desorption Recovery Rate | >95% |
| Sample Capacity | 20 positions |
| Temperature Control Accuracy | <±0.1 °C |
| Heating Ramp Rate | >2000 °C/min |
| Carrier Gas Flow | 0–400 mL/min (continuously adjustable) |
| Dimensions | 450 × 360 × 510 mm |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3430 |
| Instrument Type | Single-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Desorption Temperature Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Valve Temperature Range | Ambient to 260 °C (±1 °C) |
| Transfer Line Temperature Range | Ambient to 260 °C (±1 °C) |
| Cold Trap Temperature | Ambient |
| Temperature Stability | < ±1 °C |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split ratio) |
| Peak Width (FWHM) | <3 s |
| Sample Capacity | 1 tube per run |
| Carrier Gas Flow | 0–100 mL/min (adjustable, with flow indicator) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| Timing Resolution | 0.1–99 min (timing error <0.1%) |
| Programmable External Events | 15 |
| Power Consumption | <1000 VA |
| Dimensions (H×W×D) | 470×500×380 mm |
| Weight | ~35 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3430S |
| Automation Level | Fully Automated |
| Desorption Temperature Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Valve Temperature Range | Ambient to 260 °C (±1 °C) |
| Transfer Line Temperature Range | Ambient to 260 °C (±1 °C) |
| Cold Trap Temperature | Ambient |
| Temperature Stability | < ±1 °C |
| Desorption Recovery Rate | >98% (toluene, 0.1 µL, 10:1 split ratio) |
| Peak Width (FWHM) | <3 s |
| Sample Capacity | 30 tubes |
| Programmable Events | Up to 15 |
| Event Timing Range | 0.1–99 min (<0.1% timing error) |
| Carrier Gas Flow | 0–100 mL/min (adjustable, digital indication) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| RSD | <2.5% (GC-dependent) |
| Power Consumption | <1000 VA |
| Trigger Signal Output Delay | <2 s |
| Dimensions (H×W×D) | 470×490×450 mm |
| Weight | ~40 kg |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3440 |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Primary Desorption Temp Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Secondary Desorption Temp Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment, >3000 °C/min ramp rate) |
| Cold Trap Temp Range | Ambient to −40 °C (±1 °C accuracy, 1 °C increment) |
| Valve & Transfer Line Temp Range | Ambient to 260 °C (±1 °C accuracy, 1 °C increment) |
| Sample Capacity | 1 tube per run |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split) |
| Peak Width (FWHM) | <3 s |
| RSD | <2.5% (GC-dependent) |
| Carrier Gas Flow | 0–100 mL/min (adjustable, visual indicator) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| External Event Control | 15 programmable events |
| Event Timing Range | 0.1–99 min (<0.1% timing error) |
| Tube Materials | Stainless steel, quartz glass, fused silica capillary (optional) |
| Power Consumption | <1000 VA |
| GC Trigger Latency | <2 s |
| Dimensions (H×W×D) | 470×500×380 mm |
| Weight | ~35 kg |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3440S |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 380°C, ±0.5°C accuracy, 1°C increment |
| Secondary Desorption Temp Range | Ambient to 380°C, ±0.5°C accuracy, 1°C increment, >3000°C/min ramp rate |
| Cold Trap Temp Range | Ambient to –40°C (ambient-dependent), ±1°C accuracy, 1°C increment |
| Valve & Transfer Line Temp Range | Ambient to 260°C, ±1°C accuracy, 1°C increment |
| Sample Capacity | 30 tubes |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split) |
| Peak Width (FWHM) | <3 s |
| RSD | <2.5% (GC-dependent) |
| Power Consumption | <1000 VA |
| Dimensions (H×W×D) | 470 × 490 × 450 mm |
| Weight | ~40 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3440S-II |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment) |
| Secondary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment, >3000°C/min ramp rate) |
| Cold Trap Temp Range | Ambient to –40°C (±1°C accuracy, 1°C increment) |
| Valve & Transfer Line Temp Range | Ambient to 260°C (±1°C accuracy, 1°C increment) |
| Sample Capacity | 40 tubes |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split) |
| Peak Width (FWHM) | <3 s |
| RSD | <2.5% (system-dependent, GC and operator performance included) |
| Power Consumption | <1000 VA |
| Dimensions (H×W×D) | 470 × 490 × 450 mm |
| Weight | ~40 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-4133 |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment) |
| Secondary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment, >3000°C/min ramp rate) |
| Cold Trap Temp Range | Ambient to −40°C (±1°C accuracy, 1°C increment) |
| Valve & Transfer Line Temp Range | Ambient to 260°C (±1°C accuracy) |
| Sample Pathway Temp Range | Ambient to 200°C (±1°C accuracy) |
| Sample Capacity | 50 tubes |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split ratio) |
| Peak Width (FWHM) | <3 s |
| RSD | <2.5% |
| Tube Material | Stainless steel |
| Trap Options | Stainless steel, quartz glass, or fused silica capillary |
| Carrier Gas Flow | 0–100 mL/min (adjustable with flow indicator) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| External Event Control | 15 programmable events |
| Event Timing Range | 0.1–99 min (<0.1% timing error) |
| Power Consumption | <1000 VA |
| GC Trigger Latency | <2 s |
| Dimensions (H×W×D) | 500 × 485 × 650 mm |
| Weight | ~45 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-51 |
| Instrument Type | Dual-stage thermal desorber |
| Automation Level | Fully automated |
| Primary Desorption Temperature Range | 50–380 °C |
| Secondary Desorption Temperature Range | 150–380 °C |
| Valve & Transfer Line Temperature Range | Ambient to 260 °C |
| Cold Trap Temperature Range | Ambient to −40 °C |
| Temperature Control Accuracy | < ±0.1 °C |
| Peak Width (FWHM) | < 3 s |
| Desorption Efficiency | >98% (toluene, 0.1 µL, 10:1 split ratio) |
| Sample Capacity | 51 positions |
| Compliance | Designed for ASTM D6196, ISO 16017-1, USP <621>, and EPA TO-17 workflows |
| Brand | Huifen Instruments |
|---|---|
| Origin | Shandong, China |
| Model | TD-06 |
| Type | Single-Stage Thermal Desorber |
| Gas Path Material | Passivated 316 Stainless Steel Tubing |
| Valve System | Precision Motorized 6-Port High-Temperature Valve (Low Dead Volume) |
| Sample Tube Handling | Manual Loading with Optimized Sealing Design |
| Tube Cleaning Function | Integrated Purge Cycle for Cross-Contamination Prevention |
| Temperature Control | Rapid-Heating Sample & Transfer Zones with Minimal Thermal Gradient |
| Flow Control | High-Accuracy Pressure and Mass Flow Regulation |
| Data Synchronization | TTL/Relay Trigger Output for GC and Data System Coordination |
| Method Storage | 10 User-Defined Thermal Desorption Protocols |
| Brand | JAI |
|---|---|
| Origin | Japan |
| Instrument Type | Dual-Stage Thermal Desorber |
| Heating Method | Curie-Point (Standard 280 °C) + Resistive (–99 °C to 350 °C) |
| Cooling | Liquid Nitrogen (–99 °C) |
| Sample Capacity | Up to 48 sequential analyses (15 PAT tubes + programmable repeat/swap logic) |
| PAT Tube Dimensions | 12 mm ID × 50 mm height, 10 mL internal volume |
| Transfer Line Temp Range | Ambient +10 °C to 300 °C |
| GC Interface | Direct column connection or syringe-type injection |
| Power Supply | AC 100 V, 50/60 Hz, 15 A |
| RF Generator | 600 kHz, 48 W |
| Dimensions (Main Unit) | 355 × 210 × 130 mm, 3.1 kg |
| Liquid Nitrogen Dewar | 50 L (JTD-505III) / 20 L (JTD-505MIII), 460 mm Ø × 930 mm H, 24.8 kg |