Empowering Scientific Discovery

Thermo Fisher Scientific Environmental & Process

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported
ModelPrima BT
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPrima PRO
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeSingle Quadrupole Mass Spectrometer
GC ConfigurationConventional Gas Chromatography
Mass Range1.2–1100 amu
ResolutionUnit Mass Resolution across Full Mass Range (EI Full Scan)
Instrument Detection Limit (IDL)≤2 fg (octafluoronaphthalene, 1 pg/µL)
SensitivityUnit mass resolution maintained across entire mass range
Scan Speed20,000 u/s
Sample IntroductionOnline Cryogenic Thermal Desorption with Dual-Trap Architecture
Detection Limits≤0.02 ppb (propylene, C₂–C₅), ≤0.01 ppb (benzene, C₆–C₁₂
Analysis Cycle Time≤60 min
GC Oven Temperature Range3 °C above ambient to 450 °C (0.1 °C control precision)
Pressure ControlElectronic Pneumatic Control (EPC), 0–1000 kPa, ±0.001 psi accuracy
Carrier GasUltra-high-purity helium (99.9995%)
Data SystemEmbedded industrial PC (Intel CPU, 32 GB RAM), fully automated 7×24 operation with self-calibration, aging, and diagnostic routines
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrumentation
ModelsPrima PRO, Prima BT
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
TypeSOLA II
Measurement PrinciplePulsed Ultraviolet Fluorescence (PUVF)
Detection RangeSOLA II: 0–5 ppmS to 0–5000 ppmS
SOLA Trace0–2 ppmS to 0–5 ppmS
SOLA Flare DI10 ppmS to 95% S
Repeatability±2% FS (1 injection/min), ±1% FS (2 injections/min)
Response Time (T90)3–5 min
Communication4–20 mA, Modbus RTU/ASCII/TCP, RS-232/RS-485, Ethernet (TCP/IP)
CertificationsATEX Zone 1/2, IECEx, CSA Class I Div 1/2, NEC Class I Div 1/2, CE Mark
Environmental Operating Range12–40 °C
Power110/220 VAC, 50/60 Hz, 2000 W
Sample RequirementsLiquid or gas (ASTM D5453/D6667 compliant)
Auto-DiagnosticsValve leak detection, flow monitoring, lamp/PMT health tracking, density compensation interface