| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | 5030i |
| Measurement Principle | Beta-ray Absorption + Light Scattering (Nephelometry) |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Detection Limit | <0.5 µg/m³ (1-hr, 2σ), <0.2 µg/m³ (24-hr, 2σ) |
| Resolution | 0.1 µg/m³ |
| Accuracy | ±5% (mass-based, traceable to NIST) |
| Range | 0–10,000 µg/m³ (7 full-scale options) |
| Flow Rate | 16.67 L/min (1 m³/h), ±2% accuracy |
| Operating Temperature | Sample gas: −30 to +50 °C |
| Analyzer enclosure | +4 to +50 °C |
| Power | 100–240 VAC, 50/60 Hz, max 880 W |
| Dimensions | 425 mm (W) × 584 mm (D) × 219 mm (H) |
| Weight | 19 kg |
| Compliance | US EPA Federal Equivalent Method (FEM) for PM₂.₅ and PM₁₀, CE, UL 61010-1, CSA C22.2 No. 61010-1, FCC Class B |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 5020i |
| Measurement Principle | Pulsed Ultraviolet Fluorescence (PUVF) |
| Measured Parameter | Ambient Air Sulfate Aerosol Mass Concentration (as SO₄²⁻) |
| Range | 0–5, 10, 25, 50, or 100 μg/m³ (user-selectable) |
| Zero Noise | 0.20 μg/m³ (15-min average) |
| Limit of Detection (LOD) | 0.5 μg/m³ (15-min average) |
| Span Drift (24 h) | ±1% of full scale |
| Response Time (t₉₀) | 90 seconds |
| Sample Flow Rate | 0.4–0.5 L/min |
| Operating Temperature | 20–30 °C |
| Denuder Lifetime | 30 days (replaceable) |
| Converter Lifetime | >6 months (replaceable) |
| Dimensions (Analyzer/Converter) | 426 mm (W) × 219 mm (H) × 584 mm (D) |
| Weight (Analyzer) | ~20 kg (detector module) |
| (Converter) | ~17 kg (sample conditioning module) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TEOM 1405-DF |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM) |
| Measured Parameters | PM₁₀, PM₂.₅, and PMₜₕₒᵣₛₑ (coarse particulate matter) |
| Compliance | U.S. EPA Equivalent Method EQPM-0609-182 |
| Operating Temperature Range | −40 °C to +60 °C (sample gas) |
| Flow Rates | Fine channel: 3.0 L/min |
| Coarse channel | 1.67 L/min |
| Bypass | 12.0 L/min |
| Mass Resolution | 0.1 µg/m³ |
| Accuracy | ±2.0 µg/m³ (1-hr avg), ±1.0 µg/m³ (24-hr avg) |
| Data Output Interval | Configurable from 10 sec to 24 hr |
| Internal Memory | 500,000 records |
| Analog Outputs | 8 user-defined (0–1 V or 0–5 V DC) |
| Digital Interfaces | Ethernet, USB, RS-232, RS-485, FTP server |
| Power | Main unit: 100–240 VAC, 440 VA, 47–63 Hz |
| Vacuum pump | 120 VAC/60 Hz (4.25 A) or 240 VAC/50 Hz (2.25 A) |
| Dimensions (W×D×H) | 42.5 in × 47.5 in × 137.8 in |
| Weight | 38 kg |
| Safety Certifications | CE (EN 61326, EN 61010-1), UL 61010-1:2004, CSA C22.2 No. 61010-1:2004, FCC Part 15 Subpart B Class B |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Thermo Scientific DM5018 |
| Measurement Principle | Beta-ray Attenuation |
| Measured Parameters | TSP / PM₁₀ / PM₂.₅ |
| Measurement Range | 0–10 mg/m³ |
| Sampling Flow Rate | 16.67 L/min |
| Detection Limit | <4 µg/m³ (1-hr avg), <1 µg/m³ (24-hr avg) |
| Flow Stability | ±2% of reading |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific 5012 MAAP |
| Measurement Principle | Multi-angle integrated light absorption photometry |
| Measured Parameter | Black Carbon (BC) mass concentration and aerosol absorption coefficient (Babs) |
| Measurement Range | 0–900 ng/m³ (2-min avg), 0–180 ng/m³ (10-min avg), 0–60 ng/m³ (30-min avg) |
| Detection Limit | <100 ng/m³ BC / <0.66 Mm⁻¹ Babs (2-min), <50 ng/m³ BC / <0.33 Mm⁻¹ Babs (10-min), <20 ng/m³ BC / <0.13 Mm⁻¹ Babs (30-min) |
| Sample Flow Rate | 1 m³/h (16.7 L/min) |
| Environmental Correction | Real-time humidity and pressure compensation |
| Compliance | Designed to support EPA, EEA, and GAW reference-equivalent black carbon monitoring protocols |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Thermo Scientific 5014i |
| Measurement Principle | Beta Ray Attenuation |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Measurement Ranges | 0–100, 0–1,000, 0–2,000, 0–3,000, 0–5,000, 0–10,000 µg/m³ |
| Sampling Flow Rate | 1 m³/h (16.67 L/min) |
| Flow Stability | ±2% of setpoint |
| Minimum Detectable Concentration | 4 µg/m³ (1-hour average, 2σ), 1 µg/m³ (24-hour average, 2σ) |
| Accuracy (mass measurement) | ±5% against NIST-traceable filter standards |
| Precision | ±2 µg/m³ at concentrations <80 µg/m³ |
| Data Output Interval | 1 second |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | PM CEMS |
| Measurement Principle | Dual-Method (Beta Attenuation + Tapered Element Oscillating Microbalance, TEOM™) |
| Measured Parameter | Particulate Matter Mass Concentration (PM₁₀, PM₂.₅, or Total Suspended Particulates) |
| Range | 0–250 mg/m³ |
| Accuracy | ±20% (uncorrected), ±10% (source-corrected) |
| Detection Limit | 0.25 mg/m³ (15-min integration) |
| Response Time (T₉₀) | 15 min |
| Operating Flue Gas Temperature | ≤200 °C |
| Ambient Operating Temperature (Controller) | 4–50 °C |
| Power Supply | 200–240 VAC, 50/60 Hz, 30 A |
| Instrument Air | 80 slpm at 0.55–0.7 MPa (75–100 psi) |
| Probe Dimensions | 1117.85 mm W × 914/1524 mm L (sheath length options) × 474.73 mm H × 307.09 mm D |
| Probe Weight | 59 kg (130 lbs) |
| Controller Dimensions | 482.6 mm W × 218.95 mm H × 655.32 mm D |
| Controller Weight | 25 kg (55 lbs) |
| Analog Outputs | 6 voltage (0–100 mV, 1/5/10 V), 6 current (0–20 mA, 4–20 mA) |
| Digital/Relay Outputs | 1 power-fail alarm, 10 configurable relay outputs |
| Compliance | EPA PS-11, QA Procedure 2, Method 5/17 verified |
| Calibration Traceability | NIST-traceable mass reference |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model | 5012, MAAP |
| Measurement Principle | Multi-angle absorption photometry |
| Measured Parameters | BC (Black Carbon), PM₁₀, PM₂.₅ |
| Detection Limit (2-min avg) | <100 ng/m³ BC, <0.66 M/m Babs |
| Detection Limit (10-min avg) | <50 ng/m³ BC, <0.33 M/m Babs |
| Detection Limit (30-min avg) | <20 ng/m³ BC, <0.13 M/m Babs |
| Flow Rate | 0.5–1.4 m³/h (16.7 L/min nominal) |
| Linearity Error | <1% @ 16.7 L/min |
| Filter Medium | Glass fiber tape (~40 m length) |
| Data Storage | 18,560 concentration values |
| Operating Temperature | −20 to +50 °C |
| Power | Instrument: 100–240 V, 50/60 Hz, 30 W |
| Pump | 220–240 V, 50/60 Hz, 100 W |
| Dimensions (Instrument) | 483 × 311 × 330 mm (W×H×D) |
| Weight (Instrument) | 22.5 kg |
| Pump Dimensions | 210 × 222 × 108 mm |
| Pump Weight | 6.1 kg |
| Analog Output | 0/4–20 mA or 0–10 V |
| Digital Interface | Dual RS-232 serial ports |
| Sampling Efficiency | >98% duty cycle |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | pDR-1500 |
| Measurement Principle | Optical Light Scattering (880 nm IR) with Gravimetric Calibration Capability |
| Measured Parameters | PM₁₀, PM₂.₅ (with optional cyclone cutters) |
| Measurement Range | 0.001–400 mg/m³ (auto-ranging) |
| Sampling Flow Rate | 1.0–3.5 L/min |
| Minimum Detectable Concentration | 0.1% of reading or 0.001 mg/m³ (whichever is greater) |
| Flow Stability | ±5% of reading (traceable to SAE test protocols) |
| Resolution | 0.1% of reading or 0.001 mg/m³ (whichever is greater) |
| Accuracy | ±5% of reading (traceable to SAE standards) |
| Precision | ±2% of reading or ±0.005 mg/m³ (1-s avg) |
| Scattering Coefficient Range | ~1.5×10⁻⁶–0.6 m⁻¹ @ λ = 880 nm |
| Aerodynamic Particle Size Range | 1–10 µm |
| Optical Detection Angle | 90° |
| RH Compensation | Built-in relative humidity correction algorithm |
| Operating Temperature | –10°C to +50°C |
| Storage Temperature | –20°C to +70°C |
| Humidity Range | 10–95% RH (non-condensing) |
| Data Logging Interval | 1 s to 1 h |
| Total Memory Capacity | >500,000 data points |
| Power Supply | Internal rechargeable Li-ion battery (≥12 h field operation) + external DC input |
| Connectivity | Wi-Fi 802.11 b/g/n, iOS/Android mobile app support |
| Physical Dimensions | 181 mm (H) × 143 mm (W) × 84 mm (D) |
| Weight | 1.2 kg |
| Filter Medium | 37 mm glass fiber filter (for gravimetric validation) |
| Flow Control | Active volumetric flow control with linear flow path design |
| Inlet Configuration | Helical inlet for representative sampling without cyclone |
| Zero Calibration | Integrated HEPA-filtered zero air source |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | pDR/ADR-1500 |
| Measurement Principle | Nephelometric Light Scattering (880 nm LED) |
| Measured Parameter | PM₂.₅ (also configurable for PM₁, PM₄, PM₁₀ via interchangeable cyclones) |
| Flow Control | True Volumetric Flow Control with Digital Pressure Feedback |
| Humidity Compensation | Integrated Heated RH Sensor & Algorithmic Correction |
| Compliance | NIOSH Methods 0500 & 0600, ACGIH-Traceable Cyclones |
| Data Storage | >500,000 records |
| Display | Dual-line LCD (16×2 characters) |
| Dimensions (pDR-1500) | 181 × 143 × 84 mm |
| Dimensions (ADR-1500) | 533 × 431 × 215 mm |
| Weight (ADR-1500) | 12.9 kg |
| IP Rating | IP65 (ADR-1500) |
| Power Options | AC, DC, or Internal Rechargeable Battery |
| Communication Interfaces | USB, RS-232, 0–2 V / 4–20 mA Analog Outputs, Optional Wireless Module |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | TEOM 1405-F |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM) |
| Regulatory Designation | U.S. EPA Equivalent Method for PM2.5 (EQPM-0609-181) |
| Particle Size Fractions | PM2.5, PM10, PM1, TSP |
| Data Interfaces | Ethernet, USB, RS232, RS485, FTP Server |
| User Interface | Touchscreen LCD |
| Flow Control | Activol™ Dynamic Mass Flow Control |
| Integrated System | Filter Dynamic Measurement System (FDMS), Sensor Module, and Control Unit in Single Enclosure |
| Environmental Compensation | Heated Sample Inlet with Relative Humidity and Temperature Regulation |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | 5028i |
| Measurement Principle | Beta-ray Attenuation |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Measurement Range | 0–10 mg/m³ (0–10,000 µg/m³) |
| Sampling Flow Rate | 1 m³/h (16.67 L/min) |
| Detection Limit | <1 µg/m³ (24-hr, 2σ) |
| Data Output Interval | 1 s |
| Flow Stability | ±2% accuracy, <5% deviation |
| Regulatory Certification | US EPA EQPM for PM₁₀ (EQPM1102-150) and PM₂.₅ (EQPM0609-183) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TEOM 1405 |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM™) |
| Measured Parameter | PM₂.₅ |
| Regulatory Designation | U.S. EPA Equivalent Method for PM₁₀ (EQPM-1090-079) |
| Operating Temperature Range (Sample Gas) | −40 °C to +60 °C |
| Enclosure Operating Temperature | 2 °C to 40 °C |
| Full-Scale Range | 0–1,000,000 µg/m³ |
| Resolution | 0.1 µg/m³ |
| Accuracy (Mass Measurement) | ±0.75% |
| Precision | ±2.0 µg/m³ (1-hr avg), ±1.0 µg/m³ (24-hr avg) |
| Data Averaging Intervals | 10 s to 3600 s (default: 10 min) |
| Long-term | 30 min, 1 h, 8 h, 24 h |
| Sampling Flow Rate | 3 L/min (main), 13.67 L/min (bypass) |
| Data Output Frequency | Every 2 seconds |
| Analog Outputs | 8 configurable (0–1 V or 0–5 V DC) |
| Digital I/O | 2 relay alarms, 4 analog inputs (0–5 V DC, user-scaled) |
| Communication Interfaces | Ethernet, USB, RS-232, RS-485, FTP server |
| Internal Data Storage | 500,000 records |
| Filter Medium | Pallflex TX40, 13 mm effective diameter |
| Power Requirements | Instrument: 100–240 VAC, 440 VA, 47–63 Hz |
| Vacuum Pump | 120 VAC/60 Hz (4.25 A) or 240 VAC/50 Hz (2.25 A) |
| Dimensions (W×D×H) | 425 mm × 475 mm × 738 mm |
| Weight | 18 kg |
| Safety Certifications | CE (EN 61326, EN 61010-1), UL 61010-1:2004, CSA C22.2 No. 61010-1:2004, FCC Part 15 Subpart B Class B |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ADR-1500 |
| Pricing | Upon Request |
| Measurement Principle | Optical Light Scattering (Nephelometry) |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Enclosure Rating | IP65 |
| Power Options | AC, External DC, Internal Rechargeable Battery |
| Communication Interfaces | USB, RS-232, 0–5 V / 4–20 mA Analog Output, Optional Wireless Module |
| Environmental Compensation | Integrated Temperature, Relative Humidity, and Barometric Pressure Sensors with Active Heating |
| Flow Control | True Volumetric Flow Control via Digital Feedback Loop Using Calibrated Critical Orifice and Differential Pressure Sensor |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Thermo Scientific ADR-1500 |
| Measurement Principle | Optical Light Scattering (Nephelometry) |
| Measured Parameters | PM₁₀, PM₂.₅, PM₄, PM₁ |
| Measurement Range | 0.001–400 mg/m³ (Auto-ranging) |
| Detection Limit | 0.1 µg/m³ |
| Sampling Flow Rate | 1.0–3.5 L/min |
| Flow Stability | ±2% of reading or ±0.005 mg/m³ (whichever is greater), 1-s averaging |
| Accuracy | ±5% of reading (traceable to SAE test standards) |
| Precision | ±2% (1 s), ±0.5% (10 s), ±0.2% (60 s) |
| Scatter Coefficient Range | 1.1×10⁻⁶ to 0.6 m⁻¹ (@ λ = 880 nm) |
| Aerodynamic Particle Size Cut Points | 1.0–10 µm (with optional cyclone cutters: GK2.05 for PM₄–PM₁₀ |
| Operating Environment | IP65-rated weatherproof enclosure |
| Power Options | AC, external DC, or internal rechargeable battery (up to 100 h continuous operation) |
| Data Connectivity | Wireless/3G, USB, RS-232, analog output |
| Onboard Display | Dual-line LCD showing real-time concentration, start time, date, average concentration, and runtime |
| Temperature & Humidity Compensation | Integrated heated sensor assembly with RH/T correction |
| True Volumetric Flow Control | Enabled via digital feedback from barometric pressure, temperature, and calibrated orifice ΔP sensors |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TEOM 1405-D |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM™) |
| Measured Parameters | PM₁₀, PM₂.₅, and PM<sub>coarse</sub> (PM₁₀ − PM₂.₅) |
| Data Averaging Intervals | 10 s to 24 h |
| Mass Concentration Range | 0–1,000,000 µg/m³ |
| Resolution | 0.1 µg/m³ |
| Accuracy | ±2.0 µg/m³ (1-hr avg), ±1.0 µg/m³ (24-hr avg) |
| Mass Measurement Uncertainty | ±0.75% |
| Sampling Flow Rates | Fine channel: 3.0 L/min |
| Coarse channel | 1.67 L/min |
| Bypass | 12.0 L/min |
| Operating Ambient Temperature | −40 °C to +60 °C (sensor/control unit maintained at 2–40 °C) |
| Communication Interfaces | Ethernet, USB, RS-232, RS-485, FTP server |
| Analog I/O | 8 configurable 0–1 V or 0–5 V outputs |
| Power Requirements | Main unit: 100–240 VAC, 440 VA, 47–63 Hz |
| Vacuum pump | 120 VAC/60 Hz (4.25 A) or 240 VAC/50 Hz (2.25 A) |
| Dimensions (W×D×H) | 42.5 in × 47.5 in × 73.8 in (1080 mm × 1207.5 mm × 1875 mm) |
| Weight | 18 kg |
| Compliance | CE (EN 61326, EN 61010-1), UL 61010-1:2004, CSA C22.2 No. 61010-1:2004, FCC Part 15 Subpart B Class B |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | Model 5014i Beta |
| Measurement Principle | Beta-ray attenuation |
| Measured Parameters | PM₁₀ / PM₂.₅ |
| Radioisotope Source | Carbon-14 (¹⁴C) |
| Range Options | 0–1.0 / 2.0 / 3.0 / 5.0 / 10.0 mg/m³ (equivalent to 0–100 / 1,000 / 2,000 / 3,000 / 5,000 / 10,000 µg/m³) |
| LOD | 6 µg/m³ (0.5-hr avg), 4 µg/m³ (1-hr avg), 3 µg/m³ (3-hr avg), 1 µg/m³ (24-hr avg) |
| Resolution | 1 µg/m³ |
| Accuracy | ±5% (mass measurement, NIST-traceable membrane standards) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Thermo Scientific FH62C14 |
| Measurement Principle | Beta Ray Attenuation |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Range | 0–5,000 µg/m³ or 0–10,000 µg/m³ (selectable) |
| LOD | 4 µg/m³ (1-hr avg), 1 µg/m³ (24-hr avg) |
| Flow Rate | 1 m³/h (16.7 L/min) |
| Radioisotope | ¹⁴C sealed source in BaCO₃ matrix |
| Activity | <3.7 MBq (<100 µCi), exempt under U.S. NRC regulations |
| Data Storage | >1 year of half-hourly mass concentration averages |
| Flow Mode Options | Standard temperature & pressure (STP) or actual ambient flow |
| Interference Compensation | Automatic correction for ambient radioactivity |
| Environmental Robustness | Immune to vibration and diurnal temperature fluctuations |
| Communication | Dual RS-232 serial ports for remote control and data export |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model | 5030i (SHARP) |
| Measurement Method | Beta-ray attenuation with simultaneous optical scattering |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Measurement Ranges | 0–100, 0–1000, 0–2000, 0–3000, 0–5000, 0–10000 µg/m³ |
| Sampling Flow Rate | 16.67 L/min (1.0 m³/h) |
| Minimum Detection Limit | 1 µg/m³ (1-hour average) |
| Accuracy | ±2 µg/m³ for concentrations <80 µg/m³ |
| Flow Stability | ±5% (calibrated against NIST-traceable diaphragm standards) |
| Data Output Interval | 1 second |
| Beta Source | ¹⁴C, activity <3.7 MBq (<100 µCi) |
| Optical Source | IR LED, 6 mW, 880 nm |
| Heating System | Dynamic heated inlet (programmable temperature control) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model Series | Thermo Scientific TEOM |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM) |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Measurement Range | 0–1,000,000 µg/m³ |
| Measurement Interval | Real-time mass measurement with 6-minute data updates and 1-hour rolling averages |
| Sample Flow Rate | 3 L/min (1405F) |
| Fine-mode flow | 3 L/min / Coarse-mode flow: 1.67 L/min (1405DF) |
| Detection Limit | 0.1 µg/m³ |
| Flow Stability | ±75% during mass measurement |
| Data Storage Capacity | 5,000,000 records |
| Accuracy | ±2.0 µg/m³ (1-hr average), ±1.0 µg/m³ (24-hr average for 1405F) |
| Resolution | 0.1 µg/m³ |
| Bypass Flow | 12 L/min (1405DF), 13.67 L/min (1405F) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Thermo Scientific GM-5000 |
| Measurement Principle | Optical Scattering (for PM), Electrochemical (for SO₂, NO₂, NO, CO), Photoionization Detection (for TVOC), UV Absorption (for O₃) |
| Measured Parameters | PM₂.₅, PM₁₀, SO₂, NO₂, NO, O₃, CO, TVOC |
| Measurement Range | PM₂.₅ / PM₁₀: 0–1500 µg/m³ |
| SO₂ / NO₂ / NO / O₃ | 0–500 ppb |
| CO | 0–50 ppm |
| TVOC | 0–40 ppm |
| Sampling Interval | 10 s |
| Sample Flow Rate | >1.5 L/min |
| Detection Limits | PM₂.₅ / PM₁₀ <1.0 µg/m³ |
| SO₂ / NO₂ / NO / O₃ | 5 ppb |
| CO | 0.02 ppm |
| TVOC | 5 ppb |
| Flow Stability | ±2.5% of full scale (all sensors) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | pDR-1000AN |
| Measurement Principle | Optical Light Scattering (Forward Scatter at 50–90°) |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Detection Range | 0.001–400 mg/m³ |
| Particle Size Response | 0.1–10 µm |
| Output | Analog Voltage & Digital Serial (RS-232), Optional Alarm Relay |
| Weight | 0.5 kg |
| Dimensions | Palm-sized (approx. 12.7 × 8.9 × 4.4 cm) |
| Power | AC Adapter or Optional Rechargeable Battery |
| Calibration Traceability | NIST-traceable gravimetric calibration using SAE test dust |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model | TEOM 1405-F |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM) with Filter Dynamic Measurement System (FDMS) |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Regulatory Designation | U.S. EPA Equivalent Method for PM₂.₅ (EQPM-0609-181) |
| Operating Temperature Range | -40 °C to +60 °C (sample gas) |
| Flow Rates | Main flow = 3.0 L/min |
| Mass Resolution | 0.1 µg/m³ |
| Accuracy | ±2.0 µg/m³ (1-hr average), ±1.0 µg/m³ (24-hr average) |
| Mass Measurement Uncertainty | ±0.75% (NIST-traceable) |
| Data Output Interval | Configurable from 10 seconds to 24 hours |
| Default | 6-minute update of 1-hr and 24-hr rolling averages |
| Data Storage Capacity | 500,000 records |
| Communication Interfaces | Ethernet, USB, RS-232, RS-485, FTP server |
| Analog I/O | 8 configurable analog outputs (0–1 V or 0–5 V DC), 4 analog inputs (0–5 V DC), 2 relay alarms |
| Power Requirements | 100–240 VAC, 440 VA, 47–63 Hz (main unit) |
| Dimensions (W×D×H) | 42.5 in × 47.5 in × 137.8 in (1080 mm × 1207.5 mm × 3500 mm) |
| Weight | 33 kg |
| Safety Certifications | CE (EN 61326, EN 61010-1), UL 61010-1:2004, CSA C22.2 No. 61010-1:2004, FCC Part 15 Subpart B Class B |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | 5030 (SHARP) |
| Measurement Method | Beta-ray Absorption + Light Scattering |
| Measured Parameters | PM₁₀ / PM₂.₅ |
| Concentration Range | 0–1,000 µg/m³ and 0–10,000 µg/m³ |
| LOD | <0.5 µg/m³ @ 2σ (1-hr resolution) |
| Accuracy | ±5% vs. 24-hr FRM |
| Time Resolution | 1 min (data updated every 4 s) |
| Drift | ≤0.02% per day |
| Flow Rate | 16.67 L/min |
| Radiation Source | ¹⁴C, 3.7 MBq (100 µCi), t₁/₂ = 5700 yr |
| Optical Source | IR LED, 880 nm, 6 mW |
| Operating Temperature | −30 to +60 °C |
| Power | Instrument: 100–240 VAC, 50/60 Hz, ≤330 W |
| Pump | 220–240 VAC, 50/60 Hz, 100 W |
| Dimensions (Instrument) | 483 × 311 × 330 mm (W×H×D) |
| Weight (Instrument) | 22.5 kg |
| Weight (Pump) | 8.1 kg |