Thermo Fisher Scientific Environmental & Process

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelThermo Scientific TVA2020
Detection PrincipleFlame Ionization Detection (FID) and Photoionization Detection (PID)
Instrument TypePortable
Typical ConfigurationTotal VOC Analyzer
Detection RangeFID: 1.0–30,000 ppm methane
PID0.5–2,000 ppm isobutylene
ResolutionPID: 0.5 ppm isobutylene
FID0.5 ppm methane
AccuracyFID: ±10% of reading or ±0.1 ppm (whichever is greater) over 1.0–10,000 ppm
PID±20% of reading or ±0.5 ppm (whichever is greater) over 0.5–500 ppm
Response Time<3.5 s (90% of final value)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginDomestic (China)
Model5900-D
Detection PrincipleGas Chromatography (GC) with Flame Ionization Detection (FID) and Flame Photometric Detection (FPD)
Instrument TypeContinuous Online Analyzer
ConfigurationDual-Detector GC-Based VOC Analyzer
Measurement RangeDirect Sampling: 0–500 / 1,000 / 2,000 / 3,000 ppm (v/v)
Pre-concentrated Sampling0–50 / 100 / 200 / 300 / 500 ppb (v/v)
Detection LimitDirect Sampling (benzene-equivalent): 25 ppb (v/v)
Pre-concentrated Sampling (benzene-equivalent)30 ppt (v/v)
Accuracy≤2% (benzene, NIST-traceable calibration)
Zero Drift≤0.1% FS or ≤0.02 ppb (benzene) per 24 h
Span Drift≤0.5% FS per 24 h
Repeatability≤2% RSD (benzene)
Cycle TimeTypically <40 min (configurable for zero-gap sampling)
Sample Flow Rate5–50 mL/min (adjustable)
Sample Volume200–2,000 mL (default 400 mL, programmable)
Column Oven Temperature Range15–180 °C (stability ±0.1 °C)
Valve TypeHeated Pneumatic Membrane Valve (30–180 °C, temperature-controlled)
Carrier GasHelium, Hydrogen, or Nitrogen (>99.9995% purity, 30–50 mL/min)
Fuel Gas (FID)H₂ ≥99.999% (30–50 mL/min)
Make-up/Support Air (FID/FPD)Clean, oil-free air (300–500 mL/min)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginTaiwan
Manufacturer TypeOEM Manufacturer
Country of OriginChina (Domestically Assembled)
ModelEV-1000B
Detection PrincipleGas Chromatography–Flame Ionization Detection (GC-FID)
Instrument TypeOnline Continuous Analyzer
ConfigurationMulti-range Composite VOC Analyzer
Measurement Ranges0–50 ppm / 0–500 ppm / 0–5000 ppm / 0–5% / 0–100% (auto-ranging)
ResolutionAs specified in technical manual
Accuracy±1% F.S. or ±0.1 ppm (whichever is tighter)
Response TimeApplication-specific (45 s to 60 min per cycle)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginShanghai, China
Manufacturer TypeManufacturer
Product CategoryDomestic
Model5800-GO
Price RangeUSD $42,000–$70,000 (FOB)
Detection PrincipleGas Chromatography with Flame Ionization Detection (GC-FID)
Instrument TypePortable
ConfigurationMulti-component VOC Analyzer
Measurement Ranges0–50, 500, 5,000, 50,000 ppm
Resolution (as propane)30 ppb
Response Time≤2 min (methane/non-methane hydrocarbons)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginImported
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeOnline Analyzer
ConfigurationMulti-component VOC Analyzer
Detection Range0–50 ppm / 500 ppm / 5,000 ppm / 50,000 ppm / 500,000 ppm (as methane)
Resolution50 ppb
Accuracy±1% of full scale or 0.1 ppm (whichever is greater)
Response Time<1 minute for NMHC analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelTVA Series
Instrument TypePortable Real-Time Gas Analyzer
Typical ConfigurationDual FID & PID Detector
Detection Range (FID)1–50,000 ppm (methane equivalent)
Detection Range (PID)0.5–2,000 ppm (isobutylene equivalent)
Resolution<100 ppb (PID), <300 ppb (FID)
Accuracy±25% of reading or ±2.5 ppm (whichever is greater), per EPA Method 21 calibration protocols
Response Time (T90)≤3.5 s (both detectors)
Operating Temperature0–40 °C
Weight~5 kg
CertificationsFM Class I, Division 1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic
ModelThermo Scientific 5900 VOCs
Detection PrincipleGas Chromatography with Flame Ionization Detection (GC-FID)
Instrument TypeOnline Continuous Analyzer
Detection RangeNMHC 0–5 ppm
Accuracy≤ ±10%
Response Time≤ 15 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Instrument TypeOnline Gas Analyzer
Detection PrincipleFlame Ionization Detection (FID)
ConfigurationMulti-range VOC Analyzer
Measurement Range1, 10, 100, 1000, 5000, 10000 ppmC
Resolution0.05 ppm carbon
Accuracy±2% of reading or ±0.1 ppm (whichever is greater)
Response Time15 s (to 90% of full scale, 1 s averaging time)
Noise<0.025 ppmC (10 s averaging)
MDL0.05 ppm carbon
Zero Drift (24 h)<0.50 ppmC
Sample Flow Rate0.75–1.5 LPM
Fuel Gas25 mL/min high-purity H₂ or 110 mL/min H₂/He mixture
Temperature Control ZonesFour independent zones
Diagnostic CapabilityReal-time operational status monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginIsrael
ManufacturerOPGAL (Thermo Fisher subsidiary)
TypePortable OGI Camera
Detection PrincipleInfrared Absorption Imaging (Mid-Wave IR, MWIR)
Detection Range>400 VOCs including methane, ethylene, propane, butane, pentane, hexane, heptane, octane, benzene, toluene, xylene, styrene, ethylbenzene, formaldehyde, acetaldehyde, propionaldehyde, butadiene, butene, isobutylene, isoprene, methanol, ethanol, isopropanol, methyl ethyl ketone, acetone, ethyl acetate, methyl acetate, ethylene oxide, propylene oxide, acetic acid, and other hydrocarbons & oxygenates
Display Resolution640 × 480
Thermal Sensitivity (NETD)<12 mK @ 25 °C (for methane)
Temperature Measurement Accuracy±1 °C (0–100 °C)
Response TimeReal-time / ≤0.1 s
CertificationsATEX Zone 2
Data StorageIntegrated 64 GB SSD
ConnectivityBuilt-in Wi-Fi for live streaming and remote file transfer
LDAR IntegrationOnboard LDAR workflow engine with component tagging, geotagging, and Method 21 data fusion (PID/FID)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelThermo Scientific 55i
Detection PrincipleGas Chromatography (GC) with Flame Ionization Detection (FID)
Instrument TypeOnline Continuous Emission Monitor
ConfigurationDual-Channel GC-FID for Simultaneous CH₄ and NMHC Quantification
Measurement Ranges0–5/50/500 ppm
Resolution0.050 ppm CH₄
Accuracy±2% of reading or ±50 ppb (whichever is greater)
Response Time (t₉₀)70 s
Zero Noise0.025 ppm RMS (300-s averaging)
MDL0.050 ppm CH₄
Span Drift (24 h)<2% of full scale
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelEV-1000 VOCs CEMS
Detection PrincipleGas Chromatography with Flame Ionization Detection (GC-FID)
Instrument TypeOnline Analytical System
Typical ConfigurationMulti-component VOC Analyzer
Detection RangeVolatile Organic Compounds (VOCs), configurable up to 50 ppm, 500 ppm, 5000 ppm, 5% or 50% as methane
Resolution0.05 ppm
Accuracy±1 % of full scale or ±0.1 ppm (whichever is tighter)
Response Time≤60 seconds (average analysis cycle time)
Repeatability±1 % f.s. or ±0.1 ppm
Zero Drift±1 % f.s. or ±0.1 ppm
Span Drift±2 % f.s. or ±0.1 ppm
Sample Flow Rate600 mL/min (analysis stream)
Sample Replacement Rate3–10 L/min (max)
Calibration IntervalUser-configurable (monthly to annual)
Operating Temperature0–45 °C
Ambient Storage Temperature–20–60 °C
Relative Humidity0–85 % RH (non-condensing)
Power SupplyAC 220 V, 50 Hz, 1.5 kW
Dimensions650 mm (W) × 580 mm (D) × 1250 mm (H)
Weight160 kg
Carrier GasOil/water-free air or N₂, 60 mL/min at 2 kg/cm², THC < 0.1 ppm
FID Fuel GasH₂, 30 mL/min at 2 kg/cm², purity >99.999%, THC < 0.1 ppm
FID Make-up GasOil/water-free air, 300 mL/min at 2 kg/cm², THC < 0.1 ppm
Zero GasOil/water-free air or N₂, 2 kg/cm², THC < 0.1 ppm
Span GasHydrocarbon standard in balance gas (air or N₂), 1 kg/cm² inlet pressure
Purge GasOil/water-free air, 10 L/min at 2 kg/cm², THC < 1 ppm
Standard OutputModbus TCP
Optional Outputs4–20 mA, RS232, RS485
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported Instrument
ModelSentinel Pro
Detection PrincipleGas Chromatography-Mass Spectrometry (GC-MS) Coupled Online Sampling
Instrument CategoryOnline Real-Time Analyzer
Typical ConfigurationMulti-Channel VOC Monitoring System
Detection Range0.01–1 ppm (v/v)
ResolutionDual-Slit Selector — 60 (1 mm slit), 20 (4 mm slit)
Accuracy<0.1% relative precision
Response Time≤15 min for up to 100 sampling points
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginTaiwan
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelTVC-5800
Detection PrincipleGas Chromatography with Flame Ionization Detection (GC-FID)
Instrument TypeOnline Analyzer
Typical ConfigurationMulti-Component Speciated VOC Analyzer
Measurement Range0–50 ppm / 500 ppm / 5,000 ppm / 5% / 50% as CH₄
Resolution0.05 ppm
Accuracy±1% F.S. or ±0.1 ppm (whichever is tighter)
Response Time60 s (average)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelThermo Fisher 8000 Series TOC Analyzer
Detection PrincipleHigh-Resolution Gas Chromatography Coupled with Flame Ionization Detector (FID) or Pulsed Discharge Helium Ionization Detector (PDHID)
Analyte RangeCH₄, NMHC, Benzene, Toluene, Xylenes (o/m/p), Ethylbenzene, Trimethylbenzenes, Styrene, Ethyl Acetate, Butyl Acetate, Tetrahydrofuran (THF), Isopropanol (IPA), 1-Propanol, Acetone, Hexane, 2-Butanone, Propylene Glycol Monomethyl Ether (PGME), Propylene Glycol Monomethyl Ether Acetate (PGMEA), Cyclopentane, Cyclohexanol, Methylene Chloride, Chloroform, 1,2-Dichloroethane, 1,2-Dichloropropane, and other volatile organic compounds (VOCs)
Measurement Cycle0–60 min (user-configurable per method)
Limit of Detection (LOD)As low as sub-ppt (≤0.1 pg C) for selected analytes with PDHID
Zero Noise≤0.04 ppb (as carbon equivalent)
Repeatability (RSD)≤5% at 10× LOD
Computing PlatformEmbedded industrial PC — Intel dual-core processor, 4 GB RAM, ≥64 GB SSD (Windows IoT Enterprise)
Display12-inch full-color industrial capacitive touchscreen
Control SoftwareOnboard system control suite enabling automated sampling, chromatographic analysis, periodic calibration verification, system suitability testing, column conditioning, and unattended 7×24 operation
Data Export FormatsMS Excel (.xlsx), CSV, TXT
Real-time Status MonitoringDynamic graphical interface showing valve positions, oven temperature, detector status, pressure/flow profiles, and alarm history
DiagnosticsComprehensive self-diagnostic routines with event-logged fault codes and predictive maintenance alerts
Chromatographic Data ProcessingBatch processing support
Mechanical Format19-inch rack-mountable chassis
Dimensions (L×W×H)667 mm × 482.5 mm × 355 mm
Rack Units8U
Weight32 kg
Power Supply220 VAC ±10%, 50–60 Hz, max. 500 W
Operating Environment0 °C to 40 °C, 5–85% RH non-condensing
Communication InterfacesDual Ethernet (10/100/1000BASE-T), RS-232, RS-485, 3× USB 2.0, VGA output
Communication ProtocolsModbus TCP (standard), Modbus RTU over RS-485 (standard), optional analog outputs (0–1 V, 4–20 mA)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Origin CategoryImported
ModelTVC-55
Detection PrincipleGas Chromatography with Flame Ionization Detection (GC-FID)
Instrument TypeOnline Analyzer
ConfigurationIntegrated NMHC/CH₄ Dual-Channel Analyzer
Measurement Range0–5/50/500 ppm
Resolution0.025 ppm RMS (300-s averaging)
Accuracy±2.0% of reading or ±50 ppb (whichever is greater)
Response Time~70 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypePortable Gas Analyzer
ModelTVA2020
Detection PrincipleDual FID & PID
Key ConfigurationDual-detector VOC/Inorganic Compound Analyzer
Weight (Dual Detector)4.26 kg
Operating Temperature−10 °C to +45 °C
Battery Runtime≥10 h at 0 °C
H₂ Cylinder Runtime>10 h from 15.3 MPa
Sample Flow Rate~1 L/min
FID LOD0.5 ppm (methane)
PID LOD0.5 ppm (isobutylene)
FID Accuracy±10% of reading or ±0.1 ppm (whichever is greater), 1.0–10,000 ppm
PID Accuracy±20% of reading or ±0.5 ppm (whichever is greater), 0.5–500 ppm
FID Repeatability≤2% at 500 ppm methane
PID Repeatability≤1% at 100 ppm isobutylene
FID Linear Range1.0–30,000 ppm methane
PID Linear Range0.5–2,000 ppm isobutylene
FID/PID T₉₀ Response Time<3.5 s
Data Logging Interval1/s to 1/999 min (user-selectable)
VOC/FE mode2–30 s
Relative Humidity Range15–95% RH
Detector LifetimeFID >5,000 h
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginShanghai, China
Manufacturer TypeManufacturer
Product OriginDomestic (China)
Model6000 VOC
Detection PrincipleFlame Ionization Detection (FID)
Instrument TypeOnline Analyzer
Typical ConfigurationMulti-component VOC CEMS
Measurement Range0–5000 ppm (as methane or NMHC)
Accuracy±1% F.S. or ±0.1 ppm
Response Time≤60 s (for NMHC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
Model5800 VOCs CEMS
Detection PrincipleGas Chromatography–Flame Ionization Detection (GC-FID)
Instrument TypeOnline Continuous Analyzer
Typical ConfigurationMulti-component VOC Analyzer
Target CompoundsUp to 90 Volatile Organic Compounds
Resolution0.05 ppm
Accuracy±1% of full scale or ±0.1 ppm (whichever is greater)
Response Time1 minute (for methane/non-methane hydrocarbons)
Show next