Thermo Fisher Scientific Environmental & Process

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product CategoryImported Instrument
ModelThermo Scientific MPC 20
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelThermo Scientific TVA2020
Detection PrincipleFlame Ionization Detection (FID) and Photoionization Detection (PID)
Instrument TypePortable
Typical ConfigurationTotal VOC Analyzer
Detection RangeFID: 1.0–30,000 ppm methane
PID0.5–2,000 ppm isobutylene
ResolutionPID: 0.5 ppm isobutylene
FID0.5 ppm methane
AccuracyFID: ±10% of reading or ±0.1 ppm (whichever is greater) over 1.0–10,000 ppm
PID±20% of reading or ±0.5 ppm (whichever is greater) over 0.5–500 ppm
Response Time<3.5 s (90% of final value)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelThermo Scientific 3510VA
Instrument TypeOnline Water Quality Analyzer
AnalyteBromate
Detection PrincipleChronopotentiometric Anodic Stripping Voltammetry (ASV)
Electrode SystemMercury-free, non-plated solid working electrode
Sample ThroughputUp to 6 analyses per hour
Detection LimitSub-µg/L range (typical for bromate in drinking water matrices)
ComplianceDesigned for EPA Method 300.1 and ISO 10304-3 compatibility
Software InterfaceEmbedded web-based UI with bilingual (English/Chinese) support
Power Requirement100–240 VAC, 50/60 Hz
Enclosure RatingIP54
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
Modelalpha-pH2000D
PricingUpon Request
pH Range−2.00 to 16.00 pH
pH Resolution/Accuracy0.01 pH / ±0.01 pH
Supported Buffer StandardspH 1.01, 4.01, 6.86, 7.00, 9.00, 9.18, 10.01
ORP Range0–100% or −2000 to +2000 mV
ORP Resolution/Accuracy0.1% of full scale or 1 mV / ±2 mV
Temperature Range0–100 °C
Temperature Resolution/Accuracy0.1 °C / ±0.5 °C
ATC Sensor300 Ω NTC thermistor
Control ModesOn/Off, Proportional (P), Proportional-Integral-Derivative (PID)
Power Supply80–250 VAC, 48–62 Hz or DC
Enclosure Size1/2 DIN (144 mm × 144 mm)
Ingress ProtectionNEMA 4X
MountingPanel-mount (with optional wall-mount bracket kit)
Analog OutputsTwo isolated 0/4–20 mA outputs (configurable for pH/ORP and temperature)
Relay FunctionsDual control relays with adjustable hysteresis (0–2000 s delay), HOLD mode, cleaning cycle relay, password-protected configuration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
Model410i
Instrument TypeOnline Analyzer
Target AnalyteCO₂ (single-component gas)
Measurement Range (Standard)0–200 ppm
Resolution0.2 ppm
Repeatability±1.0% of reading
Zero Drift (24 h)±1.0 ppm
Span Drift<0.5% of reading per 24 hours
Linearity Error±1.5% of full scale
Response Time (t₉₀)90 seconds (typical average: 30 seconds)
Zero Noise (300 s avg)0.1 ppm RMS
Detection Limit (Standard Range)1 ppm
Warm-up Time<1 hour to operational stability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
ManufacturerThermo Fisher Scientific
TypeImported
Model48i
ConfigurationOnline Gas Analyzer
Target AnalyteCarbon Monoxide (CO), Single-Component
Measurement Range0–1 to 0–10,000 ppm (also available in mg/m³ equivalents)
Response Time (T90)60 s (with 30-s averaging)
Zero Drift (24 h)< 0.1 ppm
Span Drift (24 h)±1% of full scale
Zero Noise0.02 ppm RMS (30-s average)
Limit of Detection0.04 ppm
Linearity Error< ±1% of reading across full range
Data StorageFlash memory with expanded capacity
ConnectivityEthernet-enabled for remote access and control
DisplayHigh-resolution backlit LCD with multi-tier menu interface
Soft-key CustomizationUser-definable function keys for rapid navigation
ComplianceDesigned to meet EPA Performance Specification PS-1 (for ambient CO monitoring), ISO 9001-certified manufacturing, supports GLP/GMP data integrity requirements (audit trail, user authentication, electronic signature readiness per 21 CFR Part 11)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported Reference/Equivalent Method PM Sampler
ModelsPartisol 2000i (single-channel), Partisol 2000i-D (dual-channel)
Flow ControlMass Flow Controller (MFC)
Fine Particle Flow Rate15 L/min (2000i-D), Coarse Particle Flow Rate: 1.67 L/min (2000i-D)
Total Flow Range5–17 L/min (2000i)
Data Storage86 days @ 5-min intervals, 32 filter records
Operating Temperature−40 °C to +50 °C
Power1.1 A @ 240 VAC
Dimensions (H×W×D)1620 mm × 1175 mm × 927.5 mm (base unit)
Weight37.2 kg (2000i), 38.6 kg (2000i-D)
ComplianceU.S. EPA RFPS-0498-117 (PM₂.₅), RFPS-1298-126 (PM₁₀), RFPS-0509-175 (Coarse PM)
Filter FormatDual 47 mm filter holders (2000i-D), single 47 mm holder (2000i)
Cut PointsPM₂.₅ (cyclone or impactor), PM₁₀ (inlet), Coarse PM (PM₁₀–PM₂.₅ via virtual impactor in 2000i-D)
InterfaceRS-232, USB, Ethernet
SoftwareiPort™ Communications Suite, Activol™ Flow Management System
Safety CertificationCE EN 61326
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
TypeImported Instrument
Model5030i
Measurement PrincipleBeta-ray Absorption + Light Scattering (Nephelometry)
Measured ParametersPM₁₀ and PM₂.₅
Detection Limit<0.5 µg/m³ (1-hr, 2σ), <0.2 µg/m³ (24-hr, 2σ)
Resolution0.1 µg/m³
Accuracy±5% (mass-based, traceable to NIST)
Range0–10,000 µg/m³ (7 full-scale options)
Flow Rate16.67 L/min (1 m³/h), ±2% accuracy
Operating TemperatureSample gas: −30 to +50 °C
Analyzer enclosure+4 to +50 °C
Power100–240 VAC, 50/60 Hz, max 880 W
Dimensions425 mm (W) × 584 mm (D) × 219 mm (H)
Weight19 kg
ComplianceUS EPA Federal Equivalent Method (FEM) for PM₂.₅ and PM₁₀, CE, UL 61010-1, CSA C22.2 No. 61010-1, FCC Class B
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported
ModelHg CEMS
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginDomestic (China)
Model5900-D
Detection PrincipleGas Chromatography (GC) with Flame Ionization Detection (FID) and Flame Photometric Detection (FPD)
Instrument TypeContinuous Online Analyzer
ConfigurationDual-Detector GC-Based VOC Analyzer
Measurement RangeDirect Sampling: 0–500 / 1,000 / 2,000 / 3,000 ppm (v/v)
Pre-concentrated Sampling0–50 / 100 / 200 / 300 / 500 ppb (v/v)
Detection LimitDirect Sampling (benzene-equivalent): 25 ppb (v/v)
Pre-concentrated Sampling (benzene-equivalent)30 ppt (v/v)
Accuracy≤2% (benzene, NIST-traceable calibration)
Zero Drift≤0.1% FS or ≤0.02 ppb (benzene) per 24 h
Span Drift≤0.5% FS per 24 h
Repeatability≤2% RSD (benzene)
Cycle TimeTypically <40 min (configurable for zero-gap sampling)
Sample Flow Rate5–50 mL/min (adjustable)
Sample Volume200–2,000 mL (default 400 mL, programmable)
Column Oven Temperature Range15–180 °C (stability ±0.1 °C)
Valve TypeHeated Pneumatic Membrane Valve (30–180 °C, temperature-controlled)
Carrier GasHelium, Hydrogen, or Nitrogen (>99.9995% purity, 30–50 mL/min)
Fuel Gas (FID)H₂ ≥99.999% (30–50 mL/min)
Make-up/Support Air (FID/FPD)Clean, oil-free air (300–500 mL/min)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Import StatusImported
ModelDataStick Digital Sensor
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Scientific
ModelSCR-CEMS
OriginUSA
ManufacturerThermo Fisher Scientific
Instrument TypeFlue Gas Continuous Emission Monitoring System (CEMS)
Measurement ParametersNH₃, NO, NO₂, NOₓ, O₂
Dilution RatioFixed 100:1 (adjustable via calibrated sonic orifice)
Dilution Air Supply Requirement0.6 MPa, ≥20 L/min
Sample Flow Rate50–300 mL/min (typ. 50 mL/min)
NH₃ Conversion FurnaceIntegrated within probe head
Probe MaterialHastelloy C-276 / Inconel 625 (corrosion-resistant high-temp alloy)
ComplianceEPA Performance Specification 15 (PS-15), EN 15267-3, ISO 14956, US EPA Method 7E, ASTM D6522
SoftwareThermo Scientific™ CEMS Pro v5.x with 21 CFR Part 11-compliant audit trail and GLP/GMP data integrity features
Data Output4–20 mA analog, Modbus TCP/IP, OPC UA, FTP/SCP
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported Industrial-Grade Digital Water Quality Sensor System
ModelDataStick
Controller CompatibilityAV38 Universal Digital Controller (optional)
Max Sensor Nodes per Network247
Communication ProtocolsUSB, RS-232, RS-485, Modbus RTU, Profibus DP, DeviceNet, Ethernet
CalibrationFactory-calibrated
SoftwareAquaComm™ Configuration & Diagnostics Suite
ComplianceDesigned for industrial process monitoring in accordance with ISO 5667 (water sampling), ASTM D1129 (standard terminology relating to water), and compatible with GLP/GMP data integrity requirements (audit trail, user access control, electronic signature support in AquaComm v3.2+)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeOnline Turbidimeter
ModelAquaClear
Measurement Range0–200 NTU
Resolution±2% of reading (<40 NTU), ±5% of reading (>40 NTU)
Accuracy0.001 NTU
Operating Ambient Temperature−20 to +60 °C
Sample Temperature Range−5 to +50 °C
Flow Rate250–500 mL/min
Response Time90 s to 90% of final value
Light SourceTungsten lamp (≥3-year lifetime)
Flow Cell Volume135 mL
Optical Cell MaterialQuartz and anodized aluminum
ComplianceEPA Method 180.1
Temperature Units°C, °F
Output InterfacePlug-and-play communication adapter
Detection PrincipleNephelometric measurement at 90° (ISO 7027-compliant geometry)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product CategoryImported Instrument
ModelThermo Scientific AquaPro
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported
ModelAquaPro Five-Parameter System
Instrument TypeOnline Monitor
Temperature Range–5 to 95 °C
pH Range0.00–14.00 pH
Dissolved Oxygen Range0.00–20.00 ppm (0–50 °C)
Conductivity Range0–2000 µS/cm
Turbidity Range0–4000 NTU (–5 to 50 °C)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelAquaTurb / AquaSol
Instrument TypeOnline Water Quality Analyzer
Measured ParametersTurbidity, Suspended Solids (SS) Concentration
Optical MethodISO 7027-compliant Nephelometric & Backscatter Detection
Light SourceInfrared LED (850 nm)
Detection Angles90° and 180°
OutputDigital (RS-485, Modbus RTU), Optional 4–20 mA Analog
Temperature CompensationIntegrated Pt1000 sensor
Enclosure RatingIP68
Cleaning OptionOptional Automatic Wiper or Air-Pulse Self-Cleaning Module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
Model5020i
Measurement PrinciplePulsed Ultraviolet Fluorescence (PUVF)
Measured ParameterAmbient Air Sulfate Aerosol Mass Concentration (as SO₄²⁻)
Range0–5, 10, 25, 50, or 100 μg/m³ (user-selectable)
Zero Noise0.20 μg/m³ (15-min average)
Limit of Detection (LOD)0.5 μg/m³ (15-min average)
Span Drift (24 h)±1% of full scale
Response Time (t₉₀)90 seconds
Sample Flow Rate0.4–0.5 L/min
Operating Temperature20–30 °C
Denuder Lifetime30 days (replaceable)
Converter Lifetime>6 months (replaceable)
Dimensions (Analyzer/Converter)426 mm (W) × 219 mm (H) × 584 mm (D)
Weight (Analyzer)~20 kg (detector module)
(Converter)~17 kg (sample conditioning module)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
Model2000i-D / 2000i
Typical ConfigurationEPA Reference/Equivalent Method PM₂.₅ and Coarse PM Sampler
Flow ControlMass Flow Controller (MFC)
Fine Particle Flow Rate15 L/min
Coarse Particle Flow Rate1.67 L/min
Filter FormatDual 47 mm membrane holders
Data Logging Interval5 min
Internal Memory Capacity86 days @ 5-min intervals + 32 filter records
Communication InterfacesRS-232, USB, Enhanced Ethernet (iPort™)
Operating Temperature Range−40 °C to +50 °C
ComplianceU.S. EPA Reference Method for PM₂.₅ (40 CFR Part 53), Equivalent Method for PM₁₀ and Coarse PM (PM₁₀–PM₂.₅), ASTM D6216, ISO 7708
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelTEOM 1405-DF
Measurement PrincipleTapered Element Oscillating Microbalance (TEOM)
Measured ParametersPM₁₀, PM₂.₅, and PMₜₕₒᵣₛₑ (coarse particulate matter)
ComplianceU.S. EPA Equivalent Method EQPM-0609-182
Operating Temperature Range−40 °C to +60 °C (sample gas)
Flow RatesFine channel: 3.0 L/min
Coarse channel1.67 L/min
Bypass12.0 L/min
Mass Resolution0.1 µg/m³
Accuracy±2.0 µg/m³ (1-hr avg), ±1.0 µg/m³ (24-hr avg)
Data Output IntervalConfigurable from 10 sec to 24 hr
Internal Memory500,000 records
Analog Outputs8 user-defined (0–1 V or 0–5 V DC)
Digital InterfacesEthernet, USB, RS-232, RS-485, FTP server
PowerMain unit: 100–240 VAC, 440 VA, 47–63 Hz
Vacuum pump120 VAC/60 Hz (4.25 A) or 240 VAC/50 Hz (2.25 A)
Dimensions (W×D×H)42.5 in × 47.5 in × 137.8 in
Weight38 kg
Safety CertificationsCE (EN 61326, EN 61010-1), UL 61010-1:2004, CSA C22.2 No. 61010-1:2004, FCC Part 15 Subpart B Class B
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported
ModelThermo Scientific 2109XP
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product CategoryImported
Model46i Series
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginTaiwan
Manufacturer TypeOEM Manufacturer
Country of OriginChina (Domestically Assembled)
ModelEV-1000B
Detection PrincipleGas Chromatography–Flame Ionization Detection (GC-FID)
Instrument TypeOnline Continuous Analyzer
ConfigurationMulti-range Composite VOC Analyzer
Measurement Ranges0–50 ppm / 0–500 ppm / 0–5000 ppm / 0–5% / 0–100% (auto-ranging)
ResolutionAs specified in technical manual
Accuracy±1% F.S. or ±0.1 ppm (whichever is tighter)
Response TimeApplication-specific (45 s to 60 min per cycle)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported Industrial-Grade Water Quality Sensor Interface Platform
ModelAquaSensors DataStick
Communication ProtocolsRS-232 (ASCII), Modbus RTU, Modbus RS-232, USB, DeviceNet, Ethernet, CANopen
Power Input10–36 V DC
Embedded Calibration MemoryYes
Integrated Temperature SensorYes
ComplianceCE, RoHS, IP68-rated housing (sensor head)
Software CompatibilityThermo Fisher AquaLink Suite (v4.2+), third-party SCADA and PLC systems
Show next