Add to compare
BrandThermo Fisher Scientific
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported Instrument
ModelRDO Pro
PriceUpon Request
Measurement PrincipleFluorescence Lifetime Quenching
Range0–20 ppm / 0–200% saturation
Resolution0.01 ppm (<10 ppm), 0.1 ppm (≥10 ppm)
Accuracy±0.1 ppm (<8 ppm), ±0.2 ppm (8–20 ppm)
Response Timet₉₀ = 30 s, t₉₅ = 37 s
Unitsppm, % saturation, °C, °F
CalibrationSingle-point air-saturation calibration
CompensationAutomatic temperature, barometric pressure, and salinity compensation
Operating Temperature0–50 °C
Max Pressure Rating300 PSIG (20.7 bar) at 50 °C
Flow IndependenceYes
Housing MaterialsDelrin®, Polystyrene
Probe Dimensions203 mm length × 47 mm diameter
Threaded Mount1.25" NPT
Warranty2 years
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
TypeImported
ModelOzone DataStick
Instrument CategoryOnline Analyzer
Measurement PrinciplePolarographic Electrochemical Probe (Clark-type)
Range0–10 ppm
Accuracy±2% of reading
Resolution0.01 ppm
Response Timet₉₀ ≤ 90 s
CalibrationSingle-point air calibration
CompensationAutomatic temperature, atmospheric pressure, and salinity compensation
Operating Temperature–5 to 50 °C
Max Pressure65 PSIG (4.5 bar) at 50 °C
Max Flow Rate10 ft/s
Housing MaterialPEEK
Electrode SystemTriple-electrode (Au cathode, Ag anode, Ag reference electrode)
Oxygen-permeable MembranePFA-coated Teflon
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported
ModelThermo Scientific AquaPro RDO
Instrument CategoryOnline Dissolved Oxygen Analyzer
Measurement PrincipleFluorescence Quenching
Range0–20 ppm / 0–200% saturation
Accuracy±0.1 ppm (≤8 ppm), ±0.2 ppm (8–20 ppm)
Repeatability±5%
Detection Limit0.01 ppm or 0.1% saturation
Maintenance IntervalFluorescence Cap Replacement Every 2 Years
CertificationCE Marked
Regulatory ComplianceDesigned for compliance with ISO 5814:2012 (Water quality — Determination of dissolved oxygen — Electrochemical probe method), ASTM D888-22 (Standard Test Methods for Dissolved Oxygen in Water), and supports GLP/GMP data integrity requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported Instrument
ModelAquaSensors SST
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported Instrument
ModelDO DataStick
PricingAvailable Upon Request