BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
Model410i
Instrument TypeOnline Analyzer
Target AnalyteCO₂ (single-component gas)
Measurement Range (Standard)0–200 ppm
Resolution0.2 ppm
Repeatability±1.0% of reading
Zero Drift (24 h)±1.0 ppm
Span Drift<0.5% of reading per 24 hours
Linearity Error±1.5% of full scale
Response Time (t₉₀)90 seconds (typical average: 30 seconds)
Zero Noise (300 s avg)0.1 ppm RMS
Detection Limit (Standard Range)1 ppm
Warm-up Time<1 hour to operational stability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
ManufacturerThermo Fisher Scientific
TypeImported
Model48i
ConfigurationOnline Gas Analyzer
Target AnalyteCarbon Monoxide (CO), Single-Component
Measurement Range0–1 to 0–10,000 ppm (also available in mg/m³ equivalents)
Response Time (T90)60 s (with 30-s averaging)
Zero Drift (24 h)< 0.1 ppm
Span Drift (24 h)±1% of full scale
Zero Noise0.02 ppm RMS (30-s average)
Limit of Detection0.04 ppm
Linearity Error< ±1% of reading across full range
Data StorageFlash memory with expanded capacity
ConnectivityEthernet-enabled for remote access and control
DisplayHigh-resolution backlit LCD with multi-tier menu interface
Soft-key CustomizationUser-definable function keys for rapid navigation
ComplianceDesigned to meet EPA Performance Specification PS-1 (for ambient CO monitoring), ISO 9001-certified manufacturing, supports GLP/GMP data integrity requirements (audit trail, user authentication, electronic signature readiness per 21 CFR Part 11)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Scientific
OriginUSA
ManufacturerThermo Fisher Scientific
TypeOnline Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) with Fixed Bandpass Interference Filter and Quantum Detector
Model410i
Configuration Options410i-D (Standard Range), 410i-E (High Range)
Measurement Range (D)0–10,000 ppm
Measurement Range (E)0–25% vol
Zero Noise (D)0.1 ppm RMS (300 s avg)
LOD (D)0.2 ppm
Zero Drift (7 days, D)<0.20 ppm
Span Drift (7 days, D)<1% of reading
Zero Noise (E)10 ppm RMS (60 s avg)
LOD (E)20 ppm
Zero Drift (24 h, E)<40 ppm
Span Drift (7 days, E)<2% of reading
Operating Temperature Range–20 to +50 °C
Data Output OptionsDirect Extraction or Dilution Mode Reporting
ComplianceDesigned for EPA Method 3A, ASTM D6522, ISO 12039, and EN 15267-3 environments
Software Interfacei-Series Menu-Driven Firmware with Audit Trail Support (21 CFR Part 11 ready)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelMIRAN SapphIRe
Instrument TypePortable
Detection TargetMulti-component Gases
Wavelength Range7.7–14.1 µm (tunable filter) + seven fixed-bandpass filters at 1.8, 3.3, 3.6, 4.0, 4.2, 4.5, and 4.7 µm
Sample Cell Path Length0.5 m
Sample Cell Volume2.23 L
Flow Rate15 L/min
Analysis Time20 s (startup) to 3 min (full spectral acquisition)
Response Time≤18 s to 90% of final reading
Display8-line × 40-character LCD
PowerInternal rechargeable NiCd battery (7.2 V, 5.7 Ah)
Dimensions553 mm (W) × 365 mm (H) × 193 mm (D)
Weight~10 kg
Preloaded Calibration CurvesUp to 120 gases (configurable per model variant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
Model Variants48i, 48i-HL, 48i-TLE
Instrument TypeOnline Continuous Emission Monitor
Measurement PrincipleGas Filter Correlation Infrared (GFC-IR) Absorption
Detection TargetSingle-component CO gas
Range Options0–1 to 0–10,000 ppm (48i)
Repeatability±0.1 ppm
Resolution0.1 ppm
Response Time (T90)≤60 s
Zero Drift (24 h)<0.1 ppm (48i/48i-TLE), <4 ppm (48i-HL)
Span Drift (24 h)±1% FS (48i/48i-TLE), ±2% FS (48i-HL)
Linearity Error±1% FS (<1000 ppm), ±2.5% FS (>1000 ppm)
Zero Noise0.02 ppm RMS (30-s avg, 48i/48i-TLE), 2.0 ppm RMS (10-s avg, 48i-HL)
MDL0.04 ppm (48i/48i-TLE), 4.0 ppm (48i-HL)