| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Thermo Scientific TVA2020 |
| Detection Principle | Flame Ionization Detection (FID) and Photoionization Detection (PID) |
| Instrument Type | Portable |
| Typical Configuration | Total VOC Analyzer |
| Detection Range | FID: 1.0–30,000 ppm methane |
| PID | 0.5–2,000 ppm isobutylene |
| Resolution | PID: 0.5 ppm isobutylene |
| FID | 0.5 ppm methane |
| Accuracy | FID: ±10% of reading or ±0.1 ppm (whichever is greater) over 1.0–10,000 ppm |
| PID | ±20% of reading or ±0.5 ppm (whichever is greater) over 0.5–500 ppm |
| Response Time | <3.5 s (90% of final value) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 410i |
| Instrument Type | Online Analyzer |
| Target Analyte | CO₂ (single-component gas) |
| Measurement Range (Standard) | 0–200 ppm |
| Resolution | 0.2 ppm |
| Repeatability | ±1.0% of reading |
| Zero Drift (24 h) | ±1.0 ppm |
| Span Drift | <0.5% of reading per 24 hours |
| Linearity Error | ±1.5% of full scale |
| Response Time (t₉₀) | 90 seconds (typical average: 30 seconds) |
| Zero Noise (300 s avg) | 0.1 ppm RMS |
| Detection Limit (Standard Range) | 1 ppm |
| Warm-up Time | <1 hour to operational stability |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | 48i |
| Configuration | Online Gas Analyzer |
| Target Analyte | Carbon Monoxide (CO), Single-Component |
| Measurement Range | 0–1 to 0–10,000 ppm (also available in mg/m³ equivalents) |
| Response Time (T90) | 60 s (with 30-s averaging) |
| Zero Drift (24 h) | < 0.1 ppm |
| Span Drift (24 h) | ±1% of full scale |
| Zero Noise | 0.02 ppm RMS (30-s average) |
| Limit of Detection | 0.04 ppm |
| Linearity Error | < ±1% of reading across full range |
| Data Storage | Flash memory with expanded capacity |
| Connectivity | Ethernet-enabled for remote access and control |
| Display | High-resolution backlit LCD with multi-tier menu interface |
| Soft-key Customization | User-definable function keys for rapid navigation |
| Compliance | Designed to meet EPA Performance Specification PS-1 (for ambient CO monitoring), ISO 9001-certified manufacturing, supports GLP/GMP data integrity requirements (audit trail, user authentication, electronic signature readiness per 21 CFR Part 11) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Reference/Equivalent Method PM Sampler |
| Models | Partisol 2000i (single-channel), Partisol 2000i-D (dual-channel) |
| Flow Control | Mass Flow Controller (MFC) |
| Fine Particle Flow Rate | 15 L/min (2000i-D), Coarse Particle Flow Rate: 1.67 L/min (2000i-D) |
| Total Flow Range | 5–17 L/min (2000i) |
| Data Storage | 86 days @ 5-min intervals, 32 filter records |
| Operating Temperature | −40 °C to +50 °C |
| Power | 1.1 A @ 240 VAC |
| Dimensions (H×W×D) | 1620 mm × 1175 mm × 927.5 mm (base unit) |
| Weight | 37.2 kg (2000i), 38.6 kg (2000i-D) |
| Compliance | U.S. EPA RFPS-0498-117 (PM₂.₅), RFPS-1298-126 (PM₁₀), RFPS-0509-175 (Coarse PM) |
| Filter Format | Dual 47 mm filter holders (2000i-D), single 47 mm holder (2000i) |
| Cut Points | PM₂.₅ (cyclone or impactor), PM₁₀ (inlet), Coarse PM (PM₁₀–PM₂.₅ via virtual impactor in 2000i-D) |
| Interface | RS-232, USB, Ethernet |
| Software | iPort™ Communications Suite, Activol™ Flow Management System |
| Safety Certification | CE EN 61326 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | 5030i |
| Measurement Principle | Beta-ray Absorption + Light Scattering (Nephelometry) |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Detection Limit | <0.5 µg/m³ (1-hr, 2σ), <0.2 µg/m³ (24-hr, 2σ) |
| Resolution | 0.1 µg/m³ |
| Accuracy | ±5% (mass-based, traceable to NIST) |
| Range | 0–10,000 µg/m³ (7 full-scale options) |
| Flow Rate | 16.67 L/min (1 m³/h), ±2% accuracy |
| Operating Temperature | Sample gas: −30 to +50 °C |
| Analyzer enclosure | +4 to +50 °C |
| Power | 100–240 VAC, 50/60 Hz, max 880 W |
| Dimensions | 425 mm (W) × 584 mm (D) × 219 mm (H) |
| Weight | 19 kg |
| Compliance | US EPA Federal Equivalent Method (FEM) for PM₂.₅ and PM₁₀, CE, UL 61010-1, CSA C22.2 No. 61010-1, FCC Class B |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Hg CEMS |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | 5900-D |
| Detection Principle | Gas Chromatography (GC) with Flame Ionization Detection (FID) and Flame Photometric Detection (FPD) |
| Instrument Type | Continuous Online Analyzer |
| Configuration | Dual-Detector GC-Based VOC Analyzer |
| Measurement Range | Direct Sampling: 0–500 / 1,000 / 2,000 / 3,000 ppm (v/v) |
| Pre-concentrated Sampling | 0–50 / 100 / 200 / 300 / 500 ppb (v/v) |
| Detection Limit | Direct Sampling (benzene-equivalent): 25 ppb (v/v) |
| Pre-concentrated Sampling (benzene-equivalent) | 30 ppt (v/v) |
| Accuracy | ≤2% (benzene, NIST-traceable calibration) |
| Zero Drift | ≤0.1% FS or ≤0.02 ppb (benzene) per 24 h |
| Span Drift | ≤0.5% FS per 24 h |
| Repeatability | ≤2% RSD (benzene) |
| Cycle Time | Typically <40 min (configurable for zero-gap sampling) |
| Sample Flow Rate | 5–50 mL/min (adjustable) |
| Sample Volume | 200–2,000 mL (default 400 mL, programmable) |
| Column Oven Temperature Range | 15–180 °C (stability ±0.1 °C) |
| Valve Type | Heated Pneumatic Membrane Valve (30–180 °C, temperature-controlled) |
| Carrier Gas | Helium, Hydrogen, or Nitrogen (>99.9995% purity, 30–50 mL/min) |
| Fuel Gas (FID) | H₂ ≥99.999% (30–50 mL/min) |
| Make-up/Support Air (FID/FPD) | Clean, oil-free air (300–500 mL/min) |
| Brand | Thermo Scientific |
|---|---|
| Model | SCR-CEMS |
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Flue Gas Continuous Emission Monitoring System (CEMS) |
| Measurement Parameters | NH₃, NO, NO₂, NOₓ, O₂ |
| Dilution Ratio | Fixed 100:1 (adjustable via calibrated sonic orifice) |
| Dilution Air Supply Requirement | 0.6 MPa, ≥20 L/min |
| Sample Flow Rate | 50–300 mL/min (typ. 50 mL/min) |
| NH₃ Conversion Furnace | Integrated within probe head |
| Probe Material | Hastelloy C-276 / Inconel 625 (corrosion-resistant high-temp alloy) |
| Compliance | EPA Performance Specification 15 (PS-15), EN 15267-3, ISO 14956, US EPA Method 7E, ASTM D6522 |
| Software | Thermo Scientific™ CEMS Pro v5.x with 21 CFR Part 11-compliant audit trail and GLP/GMP data integrity features |
| Data Output | 4–20 mA analog, Modbus TCP/IP, OPC UA, FTP/SCP |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 5020i |
| Measurement Principle | Pulsed Ultraviolet Fluorescence (PUVF) |
| Measured Parameter | Ambient Air Sulfate Aerosol Mass Concentration (as SO₄²⁻) |
| Range | 0–5, 10, 25, 50, or 100 μg/m³ (user-selectable) |
| Zero Noise | 0.20 μg/m³ (15-min average) |
| Limit of Detection (LOD) | 0.5 μg/m³ (15-min average) |
| Span Drift (24 h) | ±1% of full scale |
| Response Time (t₉₀) | 90 seconds |
| Sample Flow Rate | 0.4–0.5 L/min |
| Operating Temperature | 20–30 °C |
| Denuder Lifetime | 30 days (replaceable) |
| Converter Lifetime | >6 months (replaceable) |
| Dimensions (Analyzer/Converter) | 426 mm (W) × 219 mm (H) × 584 mm (D) |
| Weight (Analyzer) | ~20 kg (detector module) |
| (Converter) | ~17 kg (sample conditioning module) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 2000i-D / 2000i |
| Typical Configuration | EPA Reference/Equivalent Method PM₂.₅ and Coarse PM Sampler |
| Flow Control | Mass Flow Controller (MFC) |
| Fine Particle Flow Rate | 15 L/min |
| Coarse Particle Flow Rate | 1.67 L/min |
| Filter Format | Dual 47 mm membrane holders |
| Data Logging Interval | 5 min |
| Internal Memory Capacity | 86 days @ 5-min intervals + 32 filter records |
| Communication Interfaces | RS-232, USB, Enhanced Ethernet (iPort™) |
| Operating Temperature Range | −40 °C to +50 °C |
| Compliance | U.S. EPA Reference Method for PM₂.₅ (40 CFR Part 53), Equivalent Method for PM₁₀ and Coarse PM (PM₁₀–PM₂.₅), ASTM D6216, ISO 7708 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TEOM 1405-DF |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM) |
| Measured Parameters | PM₁₀, PM₂.₅, and PMₜₕₒᵣₛₑ (coarse particulate matter) |
| Compliance | U.S. EPA Equivalent Method EQPM-0609-182 |
| Operating Temperature Range | −40 °C to +60 °C (sample gas) |
| Flow Rates | Fine channel: 3.0 L/min |
| Coarse channel | 1.67 L/min |
| Bypass | 12.0 L/min |
| Mass Resolution | 0.1 µg/m³ |
| Accuracy | ±2.0 µg/m³ (1-hr avg), ±1.0 µg/m³ (24-hr avg) |
| Data Output Interval | Configurable from 10 sec to 24 hr |
| Internal Memory | 500,000 records |
| Analog Outputs | 8 user-defined (0–1 V or 0–5 V DC) |
| Digital Interfaces | Ethernet, USB, RS-232, RS-485, FTP server |
| Power | Main unit: 100–240 VAC, 440 VA, 47–63 Hz |
| Vacuum pump | 120 VAC/60 Hz (4.25 A) or 240 VAC/50 Hz (2.25 A) |
| Dimensions (W×D×H) | 42.5 in × 47.5 in × 137.8 in |
| Weight | 38 kg |
| Safety Certifications | CE (EN 61326, EN 61010-1), UL 61010-1:2004, CSA C22.2 No. 61010-1:2004, FCC Part 15 Subpart B Class B |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | 46i Series |
| Price | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China (Domestically Assembled) |
| Model | EV-1000B |
| Detection Principle | Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Instrument Type | Online Continuous Analyzer |
| Configuration | Multi-range Composite VOC Analyzer |
| Measurement Ranges | 0–50 ppm / 0–500 ppm / 0–5000 ppm / 0–5% / 0–100% (auto-ranging) |
| Resolution | As specified in technical manual |
| Accuracy | ±1% F.S. or ±0.1 ppm (whichever is tighter) |
| Response Time | Application-specific (45 s to 60 min per cycle) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Thermo Scientific DM5018 |
| Measurement Principle | Beta-ray Attenuation |
| Measured Parameters | TSP / PM₁₀ / PM₂.₅ |
| Measurement Range | 0–10 mg/m³ |
| Sampling Flow Rate | 16.67 L/min |
| Detection Limit | <4 µg/m³ (1-hr avg), <1 µg/m³ (24-hr avg) |
| Flow Stability | ±2% of reading |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UW-50 |
| Instrument Type | Continuous Emissions Monitoring System (CEMS) |
| Measurement Accuracy | ≤1.5% F.S. |
| Repeatability | 0.5% |
| Response Time | <60 s |
| Stability | ≤±2% F.S./7 days (zero & span drift) |
| Measured Gases | SO₂, NO, CO₂ |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 43i |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific 5012 MAAP |
| Measurement Principle | Multi-angle integrated light absorption photometry |
| Measured Parameter | Black Carbon (BC) mass concentration and aerosol absorption coefficient (Babs) |
| Measurement Range | 0–900 ng/m³ (2-min avg), 0–180 ng/m³ (10-min avg), 0–60 ng/m³ (30-min avg) |
| Detection Limit | <100 ng/m³ BC / <0.66 Mm⁻¹ Babs (2-min), <50 ng/m³ BC / <0.33 Mm⁻¹ Babs (10-min), <20 ng/m³ BC / <0.13 Mm⁻¹ Babs (30-min) |
| Sample Flow Rate | 1 m³/h (16.7 L/min) |
| Environmental Correction | Real-time humidity and pressure compensation |
| Compliance | Designed to support EPA, EEA, and GAW reference-equivalent black carbon monitoring protocols |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MFC-TSP |
| Typical Configuration | Total Suspended Particulates (TSP) Sampling System |
| Flow Rate Range | 1.13 m³/min (40 ACFM) |
| Flow Accuracy | < ±1% deviation over 24 h |
| Pressure Drop Compensation | Aerodynamically optimized critical-flow Venturi restrictor |
| Flow Stability | Independent of filter loading, ambient temperature, and barometric pressure |
| Power Supply | 110 VAC, single-phase, 60 Hz (optional configurations available) |
| Motor | 1.0 HP, 7 A, 840 W |
| Weight | 62 kg (total system) |
| Cabinet | 22 kg |
| Cyclone/Cut-point Assembly | 25 kg |
| Blower & Filter Holder | 12 kg |
| Dimensions (Cabinet) | 129 cm H × 56 cm W × 56 cm D |
| Dimensions (Cyclone) | 81 cm H × 81 cm W × 63.5 cm D |
| Dimensions (Blower + Filter Holder) | 71 cm H × 53 cm W × 48 cm D |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | APIX |
| Detection Targets | Conventional + Specialty Gas Trace Impurities |
| Detection Method | Atmospheric Pressure Ionization Mass Spectrometry (API-MS) |
| Mass Range | 1–300 AMU |
| Ion Source | Atmospheric Pressure Ionization (API) |
| Background Level | <1 ppt |
| Detector | 100 MHz Pulse-Counting Electron Multiplier |
| Noise Floor | 10 counts per 10⁶ pulses |
| LOD | <10 ppt (compound-dependent) |
| Analysis Time per Component | <1 s |
| Typical Cycle Time | <5 s |
| Flow Path Switching Time | <15 min (to sub-ppb stability) |
| Compatible Bulk Gases | UHP H₂, N₂, Ar, He |
| Dimensions (δQ) | 1.9 m (H) × 0.7 m (W) × 0.65 m (D) |
| Dimensions (Quattro) | 1.9 m (H) × 2.1 m (W) × 0.65 m (D) |
| Communication Protocols | OPC UA, Modbus TCP/RTU, PROFIBUS DP, Siemens 3964R, DDE, EtherNet/IP |
| Software Platform | Thermo Scientific GasWorks® v5.x |
| Compliance | Designed for ISO 9001-certified manufacturing |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 51i |
| Pricing | Available upon Request |
| Detection Principle | Flame Ionization Detection (FID) |
| Measurement Range | 0–1 to 0–10,000 ppmC |
| Zero Noise | 0.025 ppmC RMS (10-sec avg) |
| LOD | 0.050 ppmC (10-sec avg) |
| Zero Drift (24 h) | < 0.50 ppmC |
| Span Drift (24 h) | < 2% of full scale or 0.20 ppmC (whichever is greater) |
| T90 Response Time | 15 s (1-sec avg) |
| Accuracy | ±2.0% of reading or ±0.1 ppmC (whichever is greater) |
| Linearity | ±2% of span (10–150% of span) |
| Sample Flow Rate | 0.75–1.50 L/min |
| Combustion Air Flow | 150–300 mL/min |
| Hydrocarbon-Free Air Flow | 10–35 mL/min (H₂) or 50–120 mL/min (H₂/He mixture) |
| Operating Temperature | 15–35 °C |
| Power Supply | 100/115/220–240 VAC ±10%, 50/60 Hz, 420 W |
| Dimensions (W×H×D) | 425 × 219 × 584 mm |
| Weight | 22.7 kg |
| Output Options | Isolated 0–20 mA / 4–20 mA, RS232/RS485, TCP/IP Ethernet, 10 status relays, power-fail indication |
| Input Options | 16 digital inputs (standard), 8 channels 0–10 VDC analog inputs (optional) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Thermo Scientific 5014i |
| Measurement Principle | Beta Ray Attenuation |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Measurement Ranges | 0–100, 0–1,000, 0–2,000, 0–3,000, 0–5,000, 0–10,000 µg/m³ |
| Sampling Flow Rate | 1 m³/h (16.67 L/min) |
| Flow Stability | ±2% of setpoint |
| Minimum Detectable Concentration | 4 µg/m³ (1-hour average, 2σ), 1 µg/m³ (24-hour average, 2σ) |
| Accuracy (mass measurement) | ±5% against NIST-traceable filter standards |
| Precision | ±2 µg/m³ at concentrations <80 µg/m³ |
| Data Output Interval | 1 second |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | PM CEMS |
| Measurement Principle | Dual-Method (Beta Attenuation + Tapered Element Oscillating Microbalance, TEOM™) |
| Measured Parameter | Particulate Matter Mass Concentration (PM₁₀, PM₂.₅, or Total Suspended Particulates) |
| Range | 0–250 mg/m³ |
| Accuracy | ±20% (uncorrected), ±10% (source-corrected) |
| Detection Limit | 0.25 mg/m³ (15-min integration) |
| Response Time (T₉₀) | 15 min |
| Operating Flue Gas Temperature | ≤200 °C |
| Ambient Operating Temperature (Controller) | 4–50 °C |
| Power Supply | 200–240 VAC, 50/60 Hz, 30 A |
| Instrument Air | 80 slpm at 0.55–0.7 MPa (75–100 psi) |
| Probe Dimensions | 1117.85 mm W × 914/1524 mm L (sheath length options) × 474.73 mm H × 307.09 mm D |
| Probe Weight | 59 kg (130 lbs) |
| Controller Dimensions | 482.6 mm W × 218.95 mm H × 655.32 mm D |
| Controller Weight | 25 kg (55 lbs) |
| Analog Outputs | 6 voltage (0–100 mV, 1/5/10 V), 6 current (0–20 mA, 4–20 mA) |
| Digital/Relay Outputs | 1 power-fail alarm, 10 configurable relay outputs |
| Compliance | EPA PS-11, QA Procedure 2, Method 5/17 verified |
| Calibration Traceability | NIST-traceable mass reference |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model | 5012, MAAP |
| Measurement Principle | Multi-angle absorption photometry |
| Measured Parameters | BC (Black Carbon), PM₁₀, PM₂.₅ |
| Detection Limit (2-min avg) | <100 ng/m³ BC, <0.66 M/m Babs |
| Detection Limit (10-min avg) | <50 ng/m³ BC, <0.33 M/m Babs |
| Detection Limit (30-min avg) | <20 ng/m³ BC, <0.13 M/m Babs |
| Flow Rate | 0.5–1.4 m³/h (16.7 L/min nominal) |
| Linearity Error | <1% @ 16.7 L/min |
| Filter Medium | Glass fiber tape (~40 m length) |
| Data Storage | 18,560 concentration values |
| Operating Temperature | −20 to +50 °C |
| Power | Instrument: 100–240 V, 50/60 Hz, 30 W |
| Pump | 220–240 V, 50/60 Hz, 100 W |
| Dimensions (Instrument) | 483 × 311 × 330 mm (W×H×D) |
| Weight (Instrument) | 22.5 kg |
| Pump Dimensions | 210 × 222 × 108 mm |
| Pump Weight | 6.1 kg |
| Analog Output | 0/4–20 mA or 0–10 V |
| Digital Interface | Dual RS-232 serial ports |
| Sampling Efficiency | >98% duty cycle |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Thermo Scientific 1160 |
| Pricing | Upon Request |
| Flow Rate | 1–20 L/min |
| Output Pressure | 10–60 PSI |
| Dew Point | −10 °C (membrane dryer) / −40 °C (heatless desiccant dryer) |
| Purity | SO₂ < 0.1 ppb |