Thermo Fisher Scientific Environmental & Process

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelThermo Scientific TVA2020
Detection PrincipleFlame Ionization Detection (FID) and Photoionization Detection (PID)
Instrument TypePortable
Typical ConfigurationTotal VOC Analyzer
Detection RangeFID: 1.0–30,000 ppm methane
PID0.5–2,000 ppm isobutylene
ResolutionPID: 0.5 ppm isobutylene
FID0.5 ppm methane
AccuracyFID: ±10% of reading or ±0.1 ppm (whichever is greater) over 1.0–10,000 ppm
PID±20% of reading or ±0.5 ppm (whichever is greater) over 0.5–500 ppm
Response Time<3.5 s (90% of final value)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
Model410i
Instrument TypeOnline Analyzer
Target AnalyteCO₂ (single-component gas)
Measurement Range (Standard)0–200 ppm
Resolution0.2 ppm
Repeatability±1.0% of reading
Zero Drift (24 h)±1.0 ppm
Span Drift<0.5% of reading per 24 hours
Linearity Error±1.5% of full scale
Response Time (t₉₀)90 seconds (typical average: 30 seconds)
Zero Noise (300 s avg)0.1 ppm RMS
Detection Limit (Standard Range)1 ppm
Warm-up Time<1 hour to operational stability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
ManufacturerThermo Fisher Scientific
TypeImported
Model48i
ConfigurationOnline Gas Analyzer
Target AnalyteCarbon Monoxide (CO), Single-Component
Measurement Range0–1 to 0–10,000 ppm (also available in mg/m³ equivalents)
Response Time (T90)60 s (with 30-s averaging)
Zero Drift (24 h)< 0.1 ppm
Span Drift (24 h)±1% of full scale
Zero Noise0.02 ppm RMS (30-s average)
Limit of Detection0.04 ppm
Linearity Error< ±1% of reading across full range
Data StorageFlash memory with expanded capacity
ConnectivityEthernet-enabled for remote access and control
DisplayHigh-resolution backlit LCD with multi-tier menu interface
Soft-key CustomizationUser-definable function keys for rapid navigation
ComplianceDesigned to meet EPA Performance Specification PS-1 (for ambient CO monitoring), ISO 9001-certified manufacturing, supports GLP/GMP data integrity requirements (audit trail, user authentication, electronic signature readiness per 21 CFR Part 11)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported Reference/Equivalent Method PM Sampler
ModelsPartisol 2000i (single-channel), Partisol 2000i-D (dual-channel)
Flow ControlMass Flow Controller (MFC)
Fine Particle Flow Rate15 L/min (2000i-D), Coarse Particle Flow Rate: 1.67 L/min (2000i-D)
Total Flow Range5–17 L/min (2000i)
Data Storage86 days @ 5-min intervals, 32 filter records
Operating Temperature−40 °C to +50 °C
Power1.1 A @ 240 VAC
Dimensions (H×W×D)1620 mm × 1175 mm × 927.5 mm (base unit)
Weight37.2 kg (2000i), 38.6 kg (2000i-D)
ComplianceU.S. EPA RFPS-0498-117 (PM₂.₅), RFPS-1298-126 (PM₁₀), RFPS-0509-175 (Coarse PM)
Filter FormatDual 47 mm filter holders (2000i-D), single 47 mm holder (2000i)
Cut PointsPM₂.₅ (cyclone or impactor), PM₁₀ (inlet), Coarse PM (PM₁₀–PM₂.₅ via virtual impactor in 2000i-D)
InterfaceRS-232, USB, Ethernet
SoftwareiPort™ Communications Suite, Activol™ Flow Management System
Safety CertificationCE EN 61326
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
TypeImported Instrument
Model5030i
Measurement PrincipleBeta-ray Absorption + Light Scattering (Nephelometry)
Measured ParametersPM₁₀ and PM₂.₅
Detection Limit<0.5 µg/m³ (1-hr, 2σ), <0.2 µg/m³ (24-hr, 2σ)
Resolution0.1 µg/m³
Accuracy±5% (mass-based, traceable to NIST)
Range0–10,000 µg/m³ (7 full-scale options)
Flow Rate16.67 L/min (1 m³/h), ±2% accuracy
Operating TemperatureSample gas: −30 to +50 °C
Analyzer enclosure+4 to +50 °C
Power100–240 VAC, 50/60 Hz, max 880 W
Dimensions425 mm (W) × 584 mm (D) × 219 mm (H)
Weight19 kg
ComplianceUS EPA Federal Equivalent Method (FEM) for PM₂.₅ and PM₁₀, CE, UL 61010-1, CSA C22.2 No. 61010-1, FCC Class B
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported
ModelHg CEMS
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginDomestic (China)
Model5900-D
Detection PrincipleGas Chromatography (GC) with Flame Ionization Detection (FID) and Flame Photometric Detection (FPD)
Instrument TypeContinuous Online Analyzer
ConfigurationDual-Detector GC-Based VOC Analyzer
Measurement RangeDirect Sampling: 0–500 / 1,000 / 2,000 / 3,000 ppm (v/v)
Pre-concentrated Sampling0–50 / 100 / 200 / 300 / 500 ppb (v/v)
Detection LimitDirect Sampling (benzene-equivalent): 25 ppb (v/v)
Pre-concentrated Sampling (benzene-equivalent)30 ppt (v/v)
Accuracy≤2% (benzene, NIST-traceable calibration)
Zero Drift≤0.1% FS or ≤0.02 ppb (benzene) per 24 h
Span Drift≤0.5% FS per 24 h
Repeatability≤2% RSD (benzene)
Cycle TimeTypically <40 min (configurable for zero-gap sampling)
Sample Flow Rate5–50 mL/min (adjustable)
Sample Volume200–2,000 mL (default 400 mL, programmable)
Column Oven Temperature Range15–180 °C (stability ±0.1 °C)
Valve TypeHeated Pneumatic Membrane Valve (30–180 °C, temperature-controlled)
Carrier GasHelium, Hydrogen, or Nitrogen (>99.9995% purity, 30–50 mL/min)
Fuel Gas (FID)H₂ ≥99.999% (30–50 mL/min)
Make-up/Support Air (FID/FPD)Clean, oil-free air (300–500 mL/min)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Scientific
ModelSCR-CEMS
OriginUSA
ManufacturerThermo Fisher Scientific
Instrument TypeFlue Gas Continuous Emission Monitoring System (CEMS)
Measurement ParametersNH₃, NO, NO₂, NOₓ, O₂
Dilution RatioFixed 100:1 (adjustable via calibrated sonic orifice)
Dilution Air Supply Requirement0.6 MPa, ≥20 L/min
Sample Flow Rate50–300 mL/min (typ. 50 mL/min)
NH₃ Conversion FurnaceIntegrated within probe head
Probe MaterialHastelloy C-276 / Inconel 625 (corrosion-resistant high-temp alloy)
ComplianceEPA Performance Specification 15 (PS-15), EN 15267-3, ISO 14956, US EPA Method 7E, ASTM D6522
SoftwareThermo Scientific™ CEMS Pro v5.x with 21 CFR Part 11-compliant audit trail and GLP/GMP data integrity features
Data Output4–20 mA analog, Modbus TCP/IP, OPC UA, FTP/SCP
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
Model5020i
Measurement PrinciplePulsed Ultraviolet Fluorescence (PUVF)
Measured ParameterAmbient Air Sulfate Aerosol Mass Concentration (as SO₄²⁻)
Range0–5, 10, 25, 50, or 100 μg/m³ (user-selectable)
Zero Noise0.20 μg/m³ (15-min average)
Limit of Detection (LOD)0.5 μg/m³ (15-min average)
Span Drift (24 h)±1% of full scale
Response Time (t₉₀)90 seconds
Sample Flow Rate0.4–0.5 L/min
Operating Temperature20–30 °C
Denuder Lifetime30 days (replaceable)
Converter Lifetime>6 months (replaceable)
Dimensions (Analyzer/Converter)426 mm (W) × 219 mm (H) × 584 mm (D)
Weight (Analyzer)~20 kg (detector module)
(Converter)~17 kg (sample conditioning module)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
Model2000i-D / 2000i
Typical ConfigurationEPA Reference/Equivalent Method PM₂.₅ and Coarse PM Sampler
Flow ControlMass Flow Controller (MFC)
Fine Particle Flow Rate15 L/min
Coarse Particle Flow Rate1.67 L/min
Filter FormatDual 47 mm membrane holders
Data Logging Interval5 min
Internal Memory Capacity86 days @ 5-min intervals + 32 filter records
Communication InterfacesRS-232, USB, Enhanced Ethernet (iPort™)
Operating Temperature Range−40 °C to +50 °C
ComplianceU.S. EPA Reference Method for PM₂.₅ (40 CFR Part 53), Equivalent Method for PM₁₀ and Coarse PM (PM₁₀–PM₂.₅), ASTM D6216, ISO 7708
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelTEOM 1405-DF
Measurement PrincipleTapered Element Oscillating Microbalance (TEOM)
Measured ParametersPM₁₀, PM₂.₅, and PMₜₕₒᵣₛₑ (coarse particulate matter)
ComplianceU.S. EPA Equivalent Method EQPM-0609-182
Operating Temperature Range−40 °C to +60 °C (sample gas)
Flow RatesFine channel: 3.0 L/min
Coarse channel1.67 L/min
Bypass12.0 L/min
Mass Resolution0.1 µg/m³
Accuracy±2.0 µg/m³ (1-hr avg), ±1.0 µg/m³ (24-hr avg)
Data Output IntervalConfigurable from 10 sec to 24 hr
Internal Memory500,000 records
Analog Outputs8 user-defined (0–1 V or 0–5 V DC)
Digital InterfacesEthernet, USB, RS-232, RS-485, FTP server
PowerMain unit: 100–240 VAC, 440 VA, 47–63 Hz
Vacuum pump120 VAC/60 Hz (4.25 A) or 240 VAC/50 Hz (2.25 A)
Dimensions (W×D×H)42.5 in × 47.5 in × 137.8 in
Weight38 kg
Safety CertificationsCE (EN 61326, EN 61010-1), UL 61010-1:2004, CSA C22.2 No. 61010-1:2004, FCC Part 15 Subpart B Class B
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product CategoryImported
Model46i Series
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginTaiwan
Manufacturer TypeOEM Manufacturer
Country of OriginChina (Domestically Assembled)
ModelEV-1000B
Detection PrincipleGas Chromatography–Flame Ionization Detection (GC-FID)
Instrument TypeOnline Continuous Analyzer
ConfigurationMulti-range Composite VOC Analyzer
Measurement Ranges0–50 ppm / 0–500 ppm / 0–5000 ppm / 0–5% / 0–100% (auto-ranging)
ResolutionAs specified in technical manual
Accuracy±1% F.S. or ±0.1 ppm (whichever is tighter)
Response TimeApplication-specific (45 s to 60 min per cycle)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelThermo Scientific DM5018
Measurement PrincipleBeta-ray Attenuation
Measured ParametersTSP / PM₁₀ / PM₂.₅
Measurement Range0–10 mg/m³
Sampling Flow Rate16.67 L/min
Detection Limit<4 µg/m³ (1-hr avg), <1 µg/m³ (24-hr avg)
Flow Stability±2% of reading
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelUW-50
Instrument TypeContinuous Emissions Monitoring System (CEMS)
Measurement Accuracy≤1.5% F.S.
Repeatability0.5%
Response Time<60 s
Stability≤±2% F.S./7 days (zero & span drift)
Measured GasesSO₂, NO, CO₂
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
Model43i
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelThermo Scientific 5012 MAAP
Measurement PrincipleMulti-angle integrated light absorption photometry
Measured ParameterBlack Carbon (BC) mass concentration and aerosol absorption coefficient (Babs)
Measurement Range0–900 ng/m³ (2-min avg), 0–180 ng/m³ (10-min avg), 0–60 ng/m³ (30-min avg)
Detection Limit<100 ng/m³ BC / <0.66 Mm⁻¹ Babs (2-min), <50 ng/m³ BC / <0.33 Mm⁻¹ Babs (10-min), <20 ng/m³ BC / <0.13 Mm⁻¹ Babs (30-min)
Sample Flow Rate1 m³/h (16.7 L/min)
Environmental CorrectionReal-time humidity and pressure compensation
ComplianceDesigned to support EPA, EEA, and GAW reference-equivalent black carbon monitoring protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelMFC-TSP
Typical ConfigurationTotal Suspended Particulates (TSP) Sampling System
Flow Rate Range1.13 m³/min (40 ACFM)
Flow Accuracy< ±1% deviation over 24 h
Pressure Drop CompensationAerodynamically optimized critical-flow Venturi restrictor
Flow StabilityIndependent of filter loading, ambient temperature, and barometric pressure
Power Supply110 VAC, single-phase, 60 Hz (optional configurations available)
Motor1.0 HP, 7 A, 840 W
Weight62 kg (total system)
Cabinet22 kg
Cyclone/Cut-point Assembly25 kg
Blower & Filter Holder12 kg
Dimensions (Cabinet)129 cm H × 56 cm W × 56 cm D
Dimensions (Cyclone)81 cm H × 81 cm W × 63.5 cm D
Dimensions (Blower + Filter Holder)71 cm H × 53 cm W × 48 cm D
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelAPIX
Detection TargetsConventional + Specialty Gas Trace Impurities
Detection MethodAtmospheric Pressure Ionization Mass Spectrometry (API-MS)
Mass Range1–300 AMU
Ion SourceAtmospheric Pressure Ionization (API)
Background Level<1 ppt
Detector100 MHz Pulse-Counting Electron Multiplier
Noise Floor10 counts per 10⁶ pulses
LOD<10 ppt (compound-dependent)
Analysis Time per Component<1 s
Typical Cycle Time<5 s
Flow Path Switching Time<15 min (to sub-ppb stability)
Compatible Bulk GasesUHP H₂, N₂, Ar, He
Dimensions (δQ)1.9 m (H) × 0.7 m (W) × 0.65 m (D)
Dimensions (Quattro)1.9 m (H) × 2.1 m (W) × 0.65 m (D)
Communication ProtocolsOPC UA, Modbus TCP/RTU, PROFIBUS DP, Siemens 3964R, DDE, EtherNet/IP
Software PlatformThermo Scientific GasWorks® v5.x
ComplianceDesigned for ISO 9001-certified manufacturing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
Model51i
PricingAvailable upon Request
Detection PrincipleFlame Ionization Detection (FID)
Measurement Range0–1 to 0–10,000 ppmC
Zero Noise0.025 ppmC RMS (10-sec avg)
LOD0.050 ppmC (10-sec avg)
Zero Drift (24 h)< 0.50 ppmC
Span Drift (24 h)< 2% of full scale or 0.20 ppmC (whichever is greater)
T90 Response Time15 s (1-sec avg)
Accuracy±2.0% of reading or ±0.1 ppmC (whichever is greater)
Linearity±2% of span (10–150% of span)
Sample Flow Rate0.75–1.50 L/min
Combustion Air Flow150–300 mL/min
Hydrocarbon-Free Air Flow10–35 mL/min (H₂) or 50–120 mL/min (H₂/He mixture)
Operating Temperature15–35 °C
Power Supply100/115/220–240 VAC ±10%, 50/60 Hz, 420 W
Dimensions (W×H×D)425 × 219 × 584 mm
Weight22.7 kg
Output OptionsIsolated 0–20 mA / 4–20 mA, RS232/RS485, TCP/IP Ethernet, 10 status relays, power-fail indication
Input Options16 digital inputs (standard), 8 channels 0–10 VDC analog inputs (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported Instrument
ModelThermo Scientific 5014i
Measurement PrincipleBeta Ray Attenuation
Measured ParametersPM₁₀ and PM₂.₅
Measurement Ranges0–100, 0–1,000, 0–2,000, 0–3,000, 0–5,000, 0–10,000 µg/m³
Sampling Flow Rate1 m³/h (16.67 L/min)
Flow Stability±2% of setpoint
Minimum Detectable Concentration4 µg/m³ (1-hour average, 2σ), 1 µg/m³ (24-hour average, 2σ)
Accuracy (mass measurement)±5% against NIST-traceable filter standards
Precision±2 µg/m³ at concentrations <80 µg/m³
Data Output Interval1 second
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported
ModelPM CEMS
Measurement PrincipleDual-Method (Beta Attenuation + Tapered Element Oscillating Microbalance, TEOM™)
Measured ParameterParticulate Matter Mass Concentration (PM₁₀, PM₂.₅, or Total Suspended Particulates)
Range0–250 mg/m³
Accuracy±20% (uncorrected), ±10% (source-corrected)
Detection Limit0.25 mg/m³ (15-min integration)
Response Time (T₉₀)15 min
Operating Flue Gas Temperature≤200 °C
Ambient Operating Temperature (Controller)4–50 °C
Power Supply200–240 VAC, 50/60 Hz, 30 A
Instrument Air80 slpm at 0.55–0.7 MPa (75–100 psi)
Probe Dimensions1117.85 mm W × 914/1524 mm L (sheath length options) × 474.73 mm H × 307.09 mm D
Probe Weight59 kg (130 lbs)
Controller Dimensions482.6 mm W × 218.95 mm H × 655.32 mm D
Controller Weight25 kg (55 lbs)
Analog Outputs6 voltage (0–100 mV, 1/5/10 V), 6 current (0–20 mA, 4–20 mA)
Digital/Relay Outputs1 power-fail alarm, 10 configurable relay outputs
ComplianceEPA PS-11, QA Procedure 2, Method 5/17 verified
Calibration TraceabilityNIST-traceable mass reference
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Scientific
OriginUSA
ManufacturerThermo Fisher Scientific
Model5012, MAAP
Measurement PrincipleMulti-angle absorption photometry
Measured ParametersBC (Black Carbon), PM₁₀, PM₂.₅
Detection Limit (2-min avg)<100 ng/m³ BC, <0.66 M/m Babs
Detection Limit (10-min avg)<50 ng/m³ BC, <0.33 M/m Babs
Detection Limit (30-min avg)<20 ng/m³ BC, <0.13 M/m Babs
Flow Rate0.5–1.4 m³/h (16.7 L/min nominal)
Linearity Error<1% @ 16.7 L/min
Filter MediumGlass fiber tape (~40 m length)
Data Storage18,560 concentration values
Operating Temperature−20 to +50 °C
PowerInstrument: 100–240 V, 50/60 Hz, 30 W
Pump220–240 V, 50/60 Hz, 100 W
Dimensions (Instrument)483 × 311 × 330 mm (W×H×D)
Weight (Instrument)22.5 kg
Pump Dimensions210 × 222 × 108 mm
Pump Weight6.1 kg
Analog Output0/4–20 mA or 0–10 V
Digital InterfaceDual RS-232 serial ports
Sampling Efficiency>98% duty cycle
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelThermo Scientific 1160
PricingUpon Request
Flow Rate1–20 L/min
Output Pressure10–60 PSI
Dew Point−10 °C (membrane dryer) / −40 °C (heatless desiccant dryer)
PuritySO₂ < 0.1 ppb
Show next
InstrumentHive
Logo