Thermo Fisher Scientific Environmental & Process

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
Model43i
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
Model51i
PricingAvailable upon Request
Detection PrincipleFlame Ionization Detection (FID)
Measurement Range0–1 to 0–10,000 ppmC
Zero Noise0.025 ppmC RMS (10-sec avg)
LOD0.050 ppmC (10-sec avg)
Zero Drift (24 h)< 0.50 ppmC
Span Drift (24 h)< 2% of full scale or 0.20 ppmC (whichever is greater)
T90 Response Time15 s (1-sec avg)
Accuracy±2.0% of reading or ±0.1 ppmC (whichever is greater)
Linearity±2% of span (10–150% of span)
Sample Flow Rate0.75–1.50 L/min
Combustion Air Flow150–300 mL/min
Hydrocarbon-Free Air Flow10–35 mL/min (H₂) or 50–120 mL/min (H₂/He mixture)
Operating Temperature15–35 °C
Power Supply100/115/220–240 VAC ±10%, 50/60 Hz, 420 W
Dimensions (W×H×D)425 × 219 × 584 mm
Weight22.7 kg
Output OptionsIsolated 0–20 mA / 4–20 mA, RS232/RS485, TCP/IP Ethernet, 10 status relays, power-fail indication
Input Options16 digital inputs (standard), 8 channels 0–10 VDC analog inputs (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported
Models146i, 49i-PS
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported
ModelGM-5000
Instrument TypeOnline Fixed-Station Monitor
Measured GasesNO₂, SO₂, O₃, CO
Response Time (T90)120 s (all sensors)
Measurement Accuracy±10 ppb (gaseous pollutants)
Measurement RangesNO₂: 0–20 ppm
SO₂0–50 ppm
O₃0–20 ppm
CO0–500 ppm
PM₂.₅0–1500 µg/m³
PM₁₀0–1500 µg/m³
Detection Limits (2σ)NO₂: 30 ppb
SO₂40 ppb
O₃30 ppb
CO25 ppb
PM₂.₅ & PM₁₀<1.0 µg/m³
Linearity±5% of full scale
Zero Drift±1% of full scale
Repeatability±2.5% of full scale
Resolution10 ppb (gases), 0.1 µg/m³ (PM)
Sample Flow Rate>1.5 L/min
Data Logging Interval1 min to 1 h
Onboard Storage>500,000 records (~1 year)
Operating Temperature–10 °C to +45 °C
Operating Humidity15–90% RH (non-condensing)
Power Supply100–240 VAC, 50–60 Hz
Dimensions406 mm (H) × 305 mm (W) × 152 mm (D)
Weight5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelThermo Scientific 146i
Instrument TypeOnline Calibration System
Calibrant GasesSO₂, NO₂, H₂S, NH₃, O₃, NO
Response Time<60 s
Flow Accuracy±2% of reading or ±1% of full scale (whichever is lower, at 20–100% FS)
Flow Linearity±0.5% of full scale
Flow Repeatability±2% of reading or ±1% of full scale (whichever is lower, at 20–100% FS)
Zero Air Flow Options5, 10 (standard), or 20 SLPM
Span Gas Flow Options50, 100 (standard), or 200 SCCM
Permeation Oven Temperature Control30, 35, or 45 °C ±0.1 °C
Ozone Generator Output1 ppm @ 6 SLPM (meets or exceeds U.S. EPA stability and reproducibility requirements)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginShanghai, China
ManufacturerThermo Fisher Scientific
Product TypePortable
ModelThermo Scientific 146i-GO
Gas SpeciesSO₂, NO, NO₂, CO, CH₄, NMHC (Non-Methane Hydrocarbons), or other user-defined gases
Response Time<60 s at low flow
Accuracy±0.5% of reading (10–100% of full scale)
Dilution Ratio Range1:1 to 1:2000
Operating Pressure CapabilityUp to 50 psi (for CEMS in-situ calibration)
Warm-up Time≤2 minutes
Power OptionsAC, DC, and rechargeable Li-ion battery (≥10 h runtime)
ConnectivityWi-Fi, Bluetooth 3.0/4.0
Flow OptionsS (10 SLPM / 100 SCCM), M (5 SLPM / 50 SCCM)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported
Models43i, 43i-HL, 43i-TLE
Instrument TypeOnline Continuous Emission Monitor
Target GasSO₂
Response Time (Lag Time)<20 s
Measurement Precision1 ppb (for 43i)
Measurement Ranges43i: 0–0.05 / 0.1 / 0.2 / 0.5 / 1 / 2 / 5 / 10 ppm
43i-HL0–10 / 20 / 50 / 100 / 200 / 500 / 1000 ppm
43i-TLE0–10 / 20 / 50 / 100 / 200 / 500 / 1000 ppb
Zero Noise0.5 ppb RMS (60 s avg, 43i) / 0.25 ppm RMS (300 s avg, 43i-HL) / 0.025 ppb RMS (300 s avg, 43i-TLE)
Detection Limit<0.5 ppb (43i) / 0.5 ppm (43i-HL) / 0.05 ppb (43i-TLE)
Zero Drift (24 h)<1.0 ppb (43i) / <1 ppm (43i-HL) / <0.2 ppb (43i-TLE)
Span Drift (24 h)±0.5% FS (43i) / ±1% FS (43i-HL & 43i-TLE)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
Model55i
PriceUpon Request
Measurement PrincipleBack-Flush Gas Chromatography with Flame Ionization Detection (GC-FID)
Detection TargetCH₄ and Total Non-Methane Hydrocarbons (TNMHC)
Analysis Cycle70 seconds
Detection Limit0.050 ppm (as propane, 300-s average)
Zero Noise0.025 ppm RMS
Precision±2.0% of reading or ±50 ppb (whichever is greater)
Linearity±2% of span (10–100% full scale)
Operating Temperature15–35 °C
Power Requirement100–240 V AC, 50/60 Hz, 420 W
Dimensions42.5 × 21.9 × 58.4 cm (W×H×D)
Weight27.2 kg
Sample Flow Rate≥0.5 L/min
Carrier GasN₂ (25–50 mL/min)
Zero Air275–350 mL/min (hydrocarbon-free)
Fuel GasH₂ (25–50 mL/min) or H₂/He mix (100–150 mL/min)
Output Options0–20/4–20 mA (isolated), RS232/RS485, TCP/IP, 10 relay status outputs, power failure alarm
Input Options16-bit digital input (standard), 8–10 V analog input (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
Model450i
Instrument TypeOnline Gas Analyzer
Target AnalyteHydrogen Sulfide (H₂S)
Response Time (T₉₀)80 s
Measurement Accuracy±1% of reading or ±1 ppb (whichever is greater)
Measurement Ranges0–0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10 ppm
Extended Ranges0–0.5, 1, 2, 5, 10, 20, 50, 100 ppm
Mass Concentration Ranges0–0.2, 0.5, 1, 2, 5, 10, 25 mg/m³ and 0–2, 5, 10, 20, 50, 100, 200, 250 mg/m³
Zero Noise1.0 ppb RMS (60-s averaging)
Limit of Detection (LOD)2.0 ppb (60-s averaging)
Zero Drift (24 h)<1 ppb
Span Drift (24 h)±1% of full scale
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported
Model450i
Detection PrinciplePulsed UV Fluorescence (H₂S converted to SO₂)
Measurement Range0–0.05 / 0.1 / 0.2 / 0.5 / 1 / 2 / 5 / 10 ppm
Zero Noise1.0 ppb RMS (60-sec avg)
LOD2.0 ppb (60-sec avg)
Zero Drift (24 h)<1 ppb
Span Drift (30 days)±1% FS
Optical FilterReflective Bandpass
Reaction ChamberTemperature-Stabilized
Light SourceLong-Life Pulsed UV Lamp
Data StorageInternal Flash Memory
ConnectivityEthernet (Remote Access, Firmware Update, Data Export)
DisplayHigh-Resolution LCD with 5-line auxiliary info
Show next