| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AquaChlor |
| Pricing | Upon Request |
| Measurement Principle | Amperometric Electrode (Gold Cathode / Silver Anode with Teflon Membrane) |
| Range | 0–5 ppm and 0–20 ppm |
| Resolution | 0.005 ppm |
| Accuracy | ±2% of reading or ±10 ppb, whichever is greater |
| Response Time (t₉₀) | 90 seconds |
| Units | ppm (Cl₂), °C / °F |
| Calibration | Single-point air calibration |
| Compensation | Automatic temperature compensation |
| Operating Temperature | 0–45 °C |
| Max Pressure | 15 PSIG (1.03 bar) at 40 °C |
| Flow Rate | 200–250 mL/min |
| Housing Material | Noryl |
| Electrode Materials | Gold cathode, silver anode |
| Selective Membrane | PTFE (Teflon®) |
| Communication Protocols | Modbus RTU, DeviceNet, USB, RS-232, CANopen |
| Data Interface | AV38 Local Display Unit or DataStick Network-Ready Module |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Thermo Scientific™ TSTIO1000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Electrochemical Sensing (pH & residual chlorine) + 90° Nephelometric Light Scattering (turbidity) |
| Measured Parameters | pH, Residual Chlorine, Turbidity, Temperature |
| Measurement Range | Residual Chlorine: 0.01–20 ppm |
| Accuracy | ±0.01 ppm or ±2% of Full Scale |
| Repeatability | ±2% |
| Resolution | 0.01 ppm |
| Detection Limit | 0.01 ppm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Chlorine XP |
| Instrument Type | Online Analyzer |
| Measurement Principle | DPD Colorimetric Spectrophotometry |
| Measured Parameters | Free Chlorine, Total Chlorine, Combined Chlorine |
| Range | 0.01–10 ppm |
| Accuracy | ±3% of reading |
| Repeatability | ±5% |
| Resolution | 0.01 ppm |
| Detection Limit | 0.01 ppm |
| Reagent Consumption | 0.03 mL per analysis |
| Calibration | Automatic blank calibration prior to each measurement |
| Light Source Management | Auto-adjusted LED intensity for extended lifetime |
| Cell Cleaning | Integrated automatic cuvette cleaning cycle |
| Enclosure Rating | IP65 (NEMA 4) |
| Communication Interface | RS-485 |
| Certifications | EPA Compliant, CSA Certified, ISO 9001 Certified |
| Reagent Shelf Life | 24 months (unopened), 60 days (in instrument) |
| Operating Temperature Range | Compatible with sample temperatures as low as 4°C |