Thermo Fisher Scientific Environmental & Process

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelOrion 8010cX
Instrument TypeOnline Analyzer
Measurement PrincipleSalicylate Spectrophotometry
Measurement Ranges0.02–2 mg/L
Accuracy±3% of reading + 0.04 mg/L (0.02–2 mg/L)
Detection Limit0.02 mg/L
Analysis Time≤30 min
Environmental Operating Temperature5–40 °C
Relative Humidity≤95% RH (non-condensing)
Sample Flow Rate50–1000 mL/min
Sample Pressure1–5 bar
Sample Temperature5–50 °C
Sample RequirementsTDS < 170 mg/L, TSS < 30 mg/L, pH 4–9, Color < 180 Pt-Co units
Enclosure RatingIP65
Dimensions (W×H×D)450 × 737 × 322 mm
Weight40 kg
Power Supply100–240 VAC, 100 W, 50/60 Hz
Analog OutputsTwo 4–20 mA (max. 900 Ω load)
Digital InterfaceRS485
Relay OutputsTwo dry contacts (2 A @ 250 VAC)
Regulatory CompliancecTUVus, CB, CE-LVD, RCM (safety)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelThermo Scientific Orion 2210AM
Instrument TypeOnline Analyzer
Measurement PrincipleColorimetric Method (Indophenol Blue Reaction)
Measurement Ranges0.01–2 mg/L, 0.05–10 mg/L, 0.5–50 mg/L, 5–500 mg/L (as N)
Accuracy±5% or ±0.01 mg/L (whichever is greater) within 0.01–50 mg/L
Detection Limit0.01 mg/L (as N)
Analysis Time≤30 minutes per cycle
Sample ThroughputContinuous online operation (no batch processing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
Model2240
Instrument TypeOnline Analyzer
Measurement PrincipleAmmonia Gas-Sensing Electrode Method
Range0–50.0 mg/L (as N)
Accuracy±5% of reading or ±0.10 mg/L, whichever is greater
Detection Limit0.001 mg/L
Analysis Time<10 min
Calibration Time<10 min
Resolution0.001 mg/L
Repeatability≤5% RSD
Calibration ModeAutomatic Two-Point Calibration
Sample Volume per Analysis~70 mL
Reagent Consumption per Analysis~0.5 mL
Output Signals4–20 mA, RS-232, RS-485
Enclosure Mounting OptionsWall-Mounted or Freestanding
Dimensions (W×H×D)510 × 775 × 330 mm
Weight~25 kg (without reagents), ~40 kg (fully configured)