| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Orion 8030cX |
| Instrument Type | Online Analyzer |
| Measurement Principle | Heteropoly Molybdenum Blue Colorimetry |
| Detection Range | 0–5000 µg/L SiO₂ |
| LOD | <0.5 µg/L (typical, phosphate-compensated) |
| Enclosure Rating | IP65 |
| Reagent Replacement Interval | ≤100 days |
| User Interface | Capacitive Touchscreen Display |
| Platform Compatibility | Orion 8000 Series Multi-Parameter Platform |
| Compliance | Designed for GLP/GMP-aligned operation |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 2295 |
| Instrument Type | Online Analyzer |
| Measurement Range | 0.2–50 ppm PO₄³⁻ (auto-ranging) |
| Reagent Consumption | 0.2 mL per reagent per analysis cycle |
| Sample Temperature Control | Integrated heater maintains sample at 25 °C ± 1 °C |
| Light Source | Solid-state LED (no filters, no optical fibers, maintenance-free) |
| Pumping System | High-reliability peristaltic pump with specialized tubing (replacement interval: 6 months) |
| Display | Backlit LCD with real-time status, measurement, and diagnostic information |
| Data Storage | 31-day internal log of calibration events, analysis results, timestamps, and system diagnostics |
| Enclosure Rating | NEMA 4 (dust-tight, splash-resistant) |
| Power Input | 100–240 VAC, 50–60 Hz |
| Auto-Restart Function | Configurable 30-minute timeout after STOP command |
| Sampling Mode | Optional grab-sample analysis capability |
| Mounting | Panel-mount or wall-mount compatible |
| Compliance | Designed for continuous operation in regulated industrial environments (supports GLP/GMP-aligned data integrity practices) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific 2118XP |
| Instrument Category | Online Analyzer |
| Detection Range | 0–200 ppb |
| Sensor Principle | Iodide-Selective Electrode (ISE) with Onboard Reagent Dosing |
| Display | Backlit LCD |
| Calibration Interface | Guided On-Screen Calibration Workflow |
| Expandability | Optional dual-channel configuration (pH or conductivity), optional digital communication module (Modbus RTU/ASCII, 4–20 mA output) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 2230XP |
| Instrument Type | Online Analyzer |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Enclosure Rating | NEMA 4 |
| Reagent Consumption | 0.2 mL per reagent per analysis |
| Measurement Range | 0–5000 ppb SiO₂ (with enhanced accuracy in 0–500 ppb sub-range) |
| Temperature Control | Heats sample to 25 °C for low-temperature inlet streams |
| Light Source | 810 nm LED (filter-free, fiber-optic-free, maintenance-free) |
| Pump Maintenance Interval | Every 6 months |
| Data Storage | 31 days of calibration and analytical records |
| Display | Backlit LCD with multi-parameter status visualization |
| Auto-Restart Function | Configurable 30-minute timeout after STOP command |
| Sample Interface | Integrated on-line flow cell + optional grab-sample port |
| Installation | Panel-mount or wall-mount compatible |