- All
- Favorite
- Popular
- Most rated
| Brand | HORIBA |
|---|---|
| Origin | Canada |
| Model | Duetta |
| Wavelength Range (Excitation/Absorption) | 250–1000 nm |
| Wavelength Range (Emission) | 250–1100 nm |
| Slit Width (Spectral Bandpass) | 1–20 nm |
| Optical Resolution | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Fluorescence Sensitivity (Water Raman SNR) | ≥6000:1 (350 nm excitation, 5 nm bandwidth) |
| Absorbance Accuracy | ≤±0.02 A |
| Absorbance Range | 0–2 A |
| Spectral Acquisition Rate | ≥510,000 nm/min |
| A-TEEM Mode Acquisition Time | ≤30 s |
| EEM 3D Scan Time | ≤1 s (configurable) |
| Light Source | 75 W Xenon Arc Lamp |
| Detector (Fluorescence) | CCD Array |
| Detector (Absorption) | Silicon Photodiode |
| Brand | Orient KOJI |
|---|---|
| Origin | Tianjin, China |
| Model | TAP-02 |
| Instrument Type | Steady-State and Time-Resolved Fluorescence Spectrometer |
| Temperature Range | Ambient to 300°C (573 K) |
| Temperature Control Accuracy | ±0.1°C |
| Temperature Stability | ±0.2°C (40–300°C) |
| Programmable Segments | 8-step ramp/soak |
| Heating Rate | >20°C/min |
| Cooling Design | Active rapid cooling |
| Operating Environment | Ambient pressure with controllable gas flow (N₂, O₂, Ar, etc.) |
| Power Supply | AC 220 V, 5 A, 500 W |
| Compatibility | Modular integration with Hitachi F-4500/F-7000/F-4600/F-2700 |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | FluoroLog-QM |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Dispersion Elements | Dual-grating monochromator with motorized filter wheels |
| Spectral Slit Width (Spectral Bandpass) | 0.01 nm |
| Optical Resolution | 0.1 nm |
| Sensitivity (Water Raman SNR) | 35,000:1 |
| Wavelength Accuracy | ±0.3 nm |
| Excitation Sources | Continuous Xenon lamp, Pulsed Xenon lamp, CW and Pulsed Lasers (210–2200 nm coverage via modular coupling) |
| Brand | Orient KOJI |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QY-2000 |
| Price Range | USD 28,000–42,000 |
| Dispersion Unit | Grating + Bandpass Filters |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Slit/Spectral Bandwidth | CCD Detector (Fixed Optical Resolution) |
| Resolution | 1.2 nm |
| Sensitivity | >500:1 (S/N) |
| Wavelength Accuracy | ±0.2 nm |
| Excitation Sources | Tunable Xenon Lamp + Selectable LEDs (254 nm, 395 nm, 450 nm, 460 nm) |
| Detection Range | 250–850 nm |
| Integrating Sphere | PTFE-coated interior, <1% port loss, sample port diameter <8 mm |
| Dynamic Range | 7000:1 |
| PLQY Reproducibility | ±1% (mean deviation) |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Model | DeltaFlex |
| Dispersion Element | Grating |
| Instrument Type | Transient Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 1–64 nm |
| Resolution | 1 nm |
| Sensitivity | >3000:1 |
| Wavelength Accuracy | ±0.05 nm |
| Excitation Source | Pulsed Laser Diode / LED System |
| Lifetime Range | <5 ps – 1 s |
| Minimum Acquisition Interval | 1 ms |
| Dead Time | 10 ns |
| Standard Detector | Picosecond PPD Module |
| Optional NIR Detection | up to ~1700 nm |
| Spectral Coverage | 200–1600 nm (with aberration-corrected gratings) |
| Sample Volume | as low as 1 µL |
| Software | Lifetime analysis suite with ≥5-exponential fitting, FRET, anisotropy, and decay-associated spectra (DAS) modules |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Model | DeltaPro |
| Dispersion Element | Grating and Interference Filters |
| Slit Width (Spectral Bandpass) | 1.0 nm to 32 nm |
| Optical Resolution | 1.0 nm |
| Sensitivity | >3000:1 |
| Wavelength Accuracy | ±0.5 nm |
| Detector Range (Standard) | 185–650 nm (upgradable to 850 nm or 900 nm) |
| Minimum Measurable Lifetime | 25 ps (with DeltaDiode/NanoLED) |
| Lifetime Range | 25 ps to 1 s (software-selectable source-dependent) |
| Excitation Sources | DeltaDiode (UV–NIR, 10 kHz–100 MHz rep. rate), NanoLED (UV–VIS, 10 kHz–1 MHz), SpectraLED (VIS–NIR, 0.1 Hz–10 kHz) |
| System Response FWHM | <200 ps (PPD/TBX + laser diode) |
| Dead Time | 10 ns |
| Time Range | 10 ns to 11 s (DeltaPro-DD configuration) |
| Interface | USB 2.0 (no PCI card required) |
| Operating System | Windows XP/7 (32-/64-bit English) |
| Dimensions (L×W×H) | 1875 mm × 1125 mm × 625 mm (excl. PC) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Instrument Type | Imported |
| Model | AquaLog |
| Wavelength Range (Excitation) | 200–800 nm |
| Wavelength Range (Emission) | 250–800 nm |
| Wavelength Range (Absorption) | 230–800 nm |
| Excitation Monochromator | Dual-grating with automatic order-sorting filter wheel |
| Emission Monochromator | CCD-based spectrometer with 405 g/mm grating (blazed at 250 nm) |
| Spectral Bandwidth (Slit) | 5 nm |
| Spectral Resolution | 0.41 nm/pixel (configurable to 0.82, 1.64, 3.28 nm/pixel) |
| Wavelength Accuracy | ±1 nm |
| Signal-to-Noise Ratio | >20,000:1 (RMS, 350 nm excitation, water Raman peak) |
| Full EEM Acquisition Time | 30 s |
| Full Emission Spectrum Readout Time | 5 ms |
| Detector | TE-cooled back-illuminated CCD |
| Built-in Corrections | Dark current, excitation source drift, excitation/emission spectral response, inner-filter effect, 1st/2nd-order Rayleigh scatter zeroing, Raman peak subtraction |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Model | DeltaHUB |
| Core Technology | Time-Correlated Single-Photon Counting (TCSPC) |
| Lifetime Range | 25 ps – 11 s (source-dependent) |
| Excitation Sources | 100 MHz Deltadiode ps-Laser, NanoLED, or SpectraLED |
| Detector | Picosecond Photon-Counting Detector |
| Integrated Platform | TCSPC-HUB Workstation |
| Optional Accessories | Monochromator for Time-Resolved Emission Spectra (TRES), Liquid Nitrogen Cryostat, 400 MPa High-Pressure Liquid Cell |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | FluoroMax+ |
| Dispersion Element | Holographic Grating |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 0.05–30 nm |
| Spectral Resolution | ≤0.2 nm |
| Sensitivity (S/N Ratio) | >16,000:1 (water Raman, 5 nm bandwidth, 1 s integration, no order-sorting filters) |
| Wavelength Accuracy | ±0.5 nm |
| Excitation Sources | 150 W Ozone-Free Xenon Lamp, Flash Xenon Lamp, Pulsed Laser Options |
| Brand | Orient KOJI |
|---|---|
| Origin | Tianjin, China |
| Model | Micro-tau |
| Spectral Dispersion | Grating and Filter-Based |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 5–20 nm |
| Optical Resolution | 1 nm |
| Sensitivity | 5000:1 (Signal-to-Noise Ratio) |
| Wavelength Accuracy | ±5 nm |
| Excitation Source | Pulsed Laser Diode or DPSS Lasers |
| Fluorescence Lifetime Range | 50 ps – 100 s (Full Temporal Domain) |
| Spatial Resolution | <1 µm |
| Field of View (Imaging Camera) | <0.5 mm |
| Spectral Range (Microspectroscopy) | 360–1100 nm |
| Lifetime Detection Range | 400–1050 nm (Optional Extended IR-II Band) |
| Timing Resolution | ≤1 ps |
| Jitter | <10 ps |
| Counting Rate | >65 MHz per channel |
| Simultaneous Channels | ≥8 |
| Optional Modules | Cryogenic Stage (Liquid Nitrogen), Motorized XYZ Stage (FLIM-Ready), Picosecond Detectors (Wavelength- & Temperature-Tunable), Multi-Laser Combiner (266–1030 nm, up to 4 inputs), Raman Dual-Channel Add-on, Fiber-Coupled Excitation Path |
Show next