| Brand | ISS |
|---|---|
| Origin | USA |
| Model | Q2 |
| Instrument Type | Point-Scanning Confocal Microscope |
| Resolution | 1×1 to 4096×4096 pixels |
| Excitation Sources | 266 nm, 355 nm, 405 nm lasers, white-light supercontinuum laser, two-photon laser |
| Detectors | High-speed hybrid detectors, extended-Infrared avalanche photodiodes (eIR-APDs), cryogenically cooled sCMOS spectrometers |
| Scanning Modules | 2D galvanometric mirrors, piezo Z-stage, closed-loop motorized XY stage |
| Scanning Mode | Galvo-based XY scanning + piezo-driven Z-axis scanning |
| Optical Zoom | 0.25×–2.5× |
| Microscope Host | Upright or inverted configuration |
| Illumination | Tungsten-halogen lamp or white LED |
| Software Suite | Dedicated FLIM acquisition software with Phasor Plot analysis module |
| Vibration Isolation Platform | 1200 mm × 1500 mm optical table |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DeltaRAM™ X |
| Light Source Type | High-Intensity Xenon Arc Lamp |
| Illumination Mode | Internal (Epi/Illuminator-Coupled) |
| Excitation Wavelength Range | 250–650 nm |
| Wavelength Switching Speed | < 2 ms |
| Beam Uniformity | < 5% |
| Stray-Light Rejection | 10⁻⁴ |
| Wavelength Accuracy | ±1 nm |
| Optical Output | 15 mW (in 10 nm bandwidth) |
| Bandwidth Adjustment | 0–24 nm (manually adjustable slit) |
| Coupling | 2 m Liquid Light Guide included |
| Brand | Orient KOJI |
|---|---|
| Origin | Tianjin, China |
| Model | SMP-1218C |
| Surface Material | High-permeability Stainless Steel |
| Top Plate Thickness | 6 mm |
| Surface Roughness | ≤0.8 µm |
| Flatness | ≤0.05 mm/m² |
| Mounting Hole Pattern | M6 Threaded Holes (Standard Pitch: 25 mm |
| Optional | 50 mm or 100 mm) |
| Hole Type | Countersunk Through-Holes |
| Core Structure | Carbon Steel Honeycomb Sandwich |
| Base Frame | Medium-Carbon Steel with Vibration-Damping Design |
| Vertical Natural Frequency | 2.5–8 Hz |
| Peak-to-Peak Vibration Amplitude | 1–3 µm |
| Surface Finish | Matte Black Electrostatic Powder Coating |
| Customization | Available for hole spacing, large through-holes, color, and dimensional specifications |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Jobin Yvon IBH (acquired by HORIBA) |
| Model | NanoLED |
| Core Technology | Semiconductor-based pulsed diode laser |
| Wavelength Range | 250–830 nm (UV to NIR) |
| Pulse Width | <100 ps (typ. for 405 nm variant) |
| Repetition Rate | 10 kHz – 1 MHz (software-selectable in multiple discrete steps) |
| Pulse Energy | 10 pJ/pulse (at 405 nm, typical) |
| Control Interface | Single unified controller compatible with all NanoLED variants |
| Compliance | CE-marked |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Model | C12741-03 |
| Effective Pixels | 640 × 512 |
| Pixel Size | 20 µm |
| Spectral Range | 950–1700 nm |
| Cooling | Thermoelectric (−10 °C) |
| Bit Depth | 14-bit digital output |
| Frame Rate | 60 fps |
| Interface | USB 3.0 and EIA-170 (analog) simultaneously |
| Bad Pixel Rate | < 0.37% |
| Image Correction | Flat-field, background subtraction, exposure time correction |
| Brand | Orient KOJI |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EzTime-PL |
| Price Range | USD 1,400 – 7,200 (est.) |
| Component Type | Optical Instrument Module |
| Excitation Wavelength Range | 375–2200 nm |
| Pulse Width Tuning | 25 ns – 500 ms (continuous) |
| Repetition Rate | 0.01 Hz – 1 kHz |
| Lifetime Detection Range | 1 µs – 10 s |
| Output Stability (CW) | < 2% RMS |
| Electrical Rise/Fall Time | < 1 ns (50 Ω load) |
| Max. Optical Power | 5 W (configurable) |
| Synchronization Interface | TTL-compatible trigger output & input |
| Compatible Systems | HORIBA FluoroLog/FLS, Edinburgh Instruments FLS series, Becker & Hickl TCSPC MCS/Phosphorescence modes |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Auto SE |
| Spectral Range | 450–1000 nm |
| Incident Angle | 70° fixed |
| Detector | CCD array |
| Spot Size Options | 8 discrete sizes (automatically selectable) |
| Sample Stage | Motorized XYZ stage (200 mm × 200 mm travel, Z > 35 mm) |
| Optical Architecture | Liquid crystal phase modulation (no moving parts in measurement path) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | DD-## |
| Pricing | Available Upon Request |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Model | C11440-22CU |
| Image Resolution | 2048 (H) × 2048 (V) |
| Pixel Size | 6.5 µm × 6.5 µm |
| Sensor Architecture | 2×2 and 4×4 binning support |
| Onboard Memory | 512 MB |
| Readout Speed | 100 fps at full resolution via Camera Link |
| Dynamic Range | 37,000:1 (typ.) |
| Quantum Efficiency | 82% peak (at 600 nm) |
| Read Noise | 1.6 e⁻ RMS (standard scan, 100 fps), 1.4 e⁻ RMS (slow scan, 30 fps) |
| Full Well Capacity | 30,000 e⁻ (typ.) |
| Cooling | Peltier-cooled to −30 °C (with water at 15 °C) |
| Dark Current | 0.006 e⁻/pixel/s (−30 °C, typ.) |
| Exposure Range | 1 ms – 10 s (internal trigger, full frame) |
| Interface | Camera Link (base configuration) and USB 3.0 |
| ADC | True 16-bit (dual 11-bit seamless stitching) |
| Mount | C-mount |
| Brand | ISS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Alba-STED |
| Price | USD 680,000 (FOB New York) |
| Brand | Ushio |
|---|---|
| Origin | Japan |
| Model | U-150W |
| Light Source Type | Xenon Lamp |
| Illumination Mode | Internal Illumination |
| OEM Compatibility | Horiba JY FluoroMax-4 |
| Brand | Ushio |
|---|---|
| Origin | Japan |
| Lamp Type | Xenon Arc Lamp |
| Power Rating | 150 W |
| Compatible Models | Hitachi F-4500, F-2700, F-4600, F-7000 |
| OEM Part Number | 650-1500 |
| Illumination Configuration | Internal (In-Sample Chamber) Mounting |
| Import Category | Imported Instrument Component |
| Distributor Type | Authorized General Distributor |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Lamp Type | Xenon Arc Lamp |
| Power Rating | 150 W |
| Lifetime | ≥1,000 hours |
| Compatible Models | F-4500, F-2700, F-4600, F-7000 |
| Mounting Configuration | Internal Illumination (In-Spectrometer Housing) |
| Part Number | 250-1600 |
| Import Status | Genuine Imported Component |
| Brand | Orient KOJI |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | AO8310 |
| Component Category | Optical Element |
| Dimensions | 50 × 50 mm |
| Included Filters | 7 pieces with center wavelengths at 290–380 nm (broadband), 300 nm, 320 nm, 360 nm, 400 nm, 450 nm, and 510 nm |
| Brand | ISS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | FLIM/FFS Upgrade Kits |
| Instrument Type | Point-Scanning Confocal Microscope |
| Time Resolution | 1 ps |
| Acquisition Range | 100 ps – 100 ms |
| Detection Channels | 8 |
| Channel Bandwidth | 65 MHz/channel |
| Detector Configuration | NDD-based Two-Photon Detection |
| Supported Platforms | Leica TCS SP8, Nikon A1/C2, Olympus FV1000/FV1200/FV3000/FVMPE-RS, Zeiss LSM 710/LSM 780 |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Smart SE |
| Spectral Range | 450–1000 nm |
| Detector | CCD |
| Spot Visualization | Patented real-time surface imaging |
| Spot Selection | Motorized multi-size micro-spot (e.g., 30 µm, 100 µm, 300 µm) |
| Sample Stage | Motorized XYZ stage (200 mm × 200 mm travel, Z-axis range >35 mm) |
| Modulation | Liquid Crystal Variable Retarder (LCVR), no moving parts in optical path |
| Measurement Mode | Variable-angle spectroscopic ellipsometry |
| Output | Full-spectrum Ψ(λ) and Δ(λ) in <1 s per angle |
| Configuration | Supports both offline lab-based and inline process-integrated deployment |
| Brand | Orient KOJI |
|---|---|
| Origin | Tianjin, China |
| Model | SC-FLIM |
| Output Range | <400 nm – 2200 nm (UV-enhanced) |
| Pulse Energy | >1 µJ per pulse |
| Core Technology | Semiconductor Pumped Femtosecond Fiber Laser + Photonic Crystal Fiber Broadening |
| Brand | Orient KOJI |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OKI-uFRLs |
| Price Range | USD 210,000 – 280,000 (FOB Tianjin) |
| Spatial Resolution | < 1 µm |
| Spectral Resolution | ≤ 1 cm⁻¹ |
| Spectral & Lifetime Wavelength Range | 250 – 1650 nm |
| Fluorescence Lifetime Range | 100 ps – 10 ms |
| Maximum Coupled Raman Excitation Lasers | 4 wavelengths |
| Maximum FLIM Excitation Lasers | 4 wavelengths |
| Shortest Excitation Wavelength | 266 nm |
| Detector Types | High-Sensitivity PMT + Cooled CCD |
| Scanning Axes | XYZ motorized stage |
| Optical Zoom | 0.3× – 1.5× |
| Microscope Configuration | Upright or Inverted |
| Illumination Source | Tungsten-Halogen Lamp |
| Image Workstation | Integrated Windows-based platform with real-time acquisition & analysis suite |
| Vibration Isolation Table | 1500 × 1800 mm dedicated optical-grade active/passive hybrid isolation platform |
| Temperature Range (with optional cryo/hot stages) | 4 K – 550 K |
| Pressure Range (with optional DAC modules) | Up to 100 GPa (DAC) / up to 100 MPa (hydrostatic cell) |
| Brand | ISS |
|---|---|
| Origin | USA |
| Model | SMT-3D Nanoimaging |
| Category | Upgraded Add-on for Olympus FV1000/FV1200 Laser Scanning Confocal Microscopes |
| Detection Principle | Modulation Tracking via Feedback-Controlled Circular Beam Oscillation |
| Lateral Resolution | 20–40 nm (±2 nm) |
| Axial Precision | 2 nm |
| XY Tracking | Galvo Mirror System |
| Z Tracking | Piezo-Driven Stage |
| Data Acquisition Rate | 32–256 kHz |
| Orbit Frequency | 2 kHz |
| Detector | Internal PMT of FV1000/FV1200 + ISS Photon Counting Unit |
| Software | SimFCS (Globals Unlimited) |
| Compliance | Designed for GLP/GMP-aligned workflows |
Show next