- All
- Favorite
- Popular
- Most rated
| Brand | HORIBA |
|---|---|
| Origin | Canada |
| Model | Duetta |
| Wavelength Range (Excitation/Absorption) | 250–1000 nm |
| Wavelength Range (Emission) | 250–1100 nm |
| Slit Width (Spectral Bandpass) | 1–20 nm |
| Optical Resolution | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Fluorescence Sensitivity (Water Raman SNR) | ≥6000:1 (350 nm excitation, 5 nm bandwidth) |
| Absorbance Accuracy | ≤±0.02 A |
| Absorbance Range | 0–2 A |
| Spectral Acquisition Rate | ≥510,000 nm/min |
| A-TEEM Mode Acquisition Time | ≤30 s |
| EEM 3D Scan Time | ≤1 s (configurable) |
| Light Source | 75 W Xenon Arc Lamp |
| Detector (Fluorescence) | CCD Array |
| Detector (Absorption) | Silicon Photodiode |
| Brand | Orient KOJI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Luma 40 |
| Price Range | USD 6,800 – 13,600 |
| Temperature Range | −40 °C to +105 °C |
| Temperature Accuracy | ±0.2 °C (0 °C to +80 °C) |
| Temperature Precision | ±0.01 °C |
| Temperature Reproducibility | < ±0.05 °C |
| Optical Port Dimensions | 12 mm (H) × 10 mm (W) |
| Compatible Probes | Horiba Series 400 & Series 500 |
| Standard Cuvette O.D. | 12.5 mm × 12.5 mm |
| Cuvette Z-Height Options | 8.5 mm or 15 mm (specify at order) |
| Dry Gas Purge | Yes |
| Stirring | Variable-speed magnetic stirring |
| Brand | ISS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Hpcell-00 |
| Price Range | USD 2,800 – 7,000 |
| Maximum Pressure | 400 MPa (4 kbar / 43,500 psi) |
| Optical Windows | Three 10 mm diameter fused silica windows, 90° angular distribution |
| Optional Window Material | Sapphire |
| Configurable Window Count | 3 or 4 |
| Compatible With | Fluorescence spectroscopy, time-resolved fluorescence, UV-Vis absorption spectroscopy |
| Integration Method | Direct mounting on optical tables or fiber-coupled interface with commercial spectrometers |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | MicOS |
| Pricing | Available Upon Request |
| Spectrometer Models | iHR320 / iHR550 |
| Spectral Range | 190–1600 nm (with multi-detector configuration) |
| Spectral Resolution | ≤0.1 nm (with 1200 g/mm grating & open-electrode CCD) |
| Detector Options | CCD (1024 × 256), InGaAs (512 × 256), Single-Channel PMT |
| Excitation Wavelengths | 325 nm, 405 nm, 488 nm, 532 nm, 633 nm, 785 nm |
| Objective Lenses | 10×, 50×, 100× (standard) |
| Microscope Configurations | Vertical (objective-down) or lateral (side-objective) |
| Sample Stage | Manual or motorized XYZ stage (optional mapping capability) |
| Integrated Imaging | Built-in digital camera for real-time sample visualization |
| Control Software | LabSpec 8 (FDA 21 CFR Part 11 compliant audit trail, GLP/GMP-ready) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | MESA-50 |
| Form Factor | Benchtop/Portable |
| Elemental Range | Al (13) to U (92) |
| Detection Limit | ppm-level |
| Energy Resolution | 131 eV (at Mn Kα) |
| Repeatability | <1% RSD |
| Dimensions | 294 × 208 × 205 mm |
| Weight | 12 kg |
| Battery Life | Up to 6 hours |
| Sample Imaging | Coaxial CCD camera |
| Detector | Silicon Drift Detector (SDD) |
| Signal Processing | HORIBA Digital Pulse Processor (DPP) |
| Vacuum/Nitrogen Requirement | None (ambient air operation, including Cl analysis) |
| Brand | Orient KOJI |
|---|---|
| Origin | Tianjin, China |
| Model | TAP-02 |
| Instrument Type | Steady-State and Time-Resolved Fluorescence Spectrometer |
| Temperature Range | Ambient to 300°C (573 K) |
| Temperature Control Accuracy | ±0.1°C |
| Temperature Stability | ±0.2°C (40–300°C) |
| Programmable Segments | 8-step ramp/soak |
| Heating Rate | >20°C/min |
| Cooling Design | Active rapid cooling |
| Operating Environment | Ambient pressure with controllable gas flow (N₂, O₂, Ar, etc.) |
| Power Supply | AC 220 V, 5 A, 500 W |
| Compatibility | Modular integration with Hitachi F-4500/F-7000/F-4600/F-2700 |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | LabRAM XploRA PLUS XS |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–9000 cm⁻¹ |
| Spectral Resolution | <1 cm⁻¹ |
| Spatial Resolution | Lateral 0.4 µm, Axial 1.5 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.03 cm⁻¹ |
| Maximum Acquisition Speed | 1600 spectra/s |
| Pixel Dwell Time | <1 ms/pixel |
| Automated Laser Selection | Up to 3 Integrated Lasers (532 nm, 638 nm, 785 nm) |
| Grating Options | 4 Motorized Gratings |
| Detection | EMCCD and XS Fast-Imaging Detector |
| Brand | Orient KOJI |
|---|---|
| Origin | Tianjin, China |
| Model | EzTime-EL |
| Time Resolution Range | 100 ps – 10 s |
| Spectral Range | 350 nm – 1050 nm (configuration-dependent) |
| Electrical Pulse Width | <1.5 ns |
| Driving Voltage Range | 5–24 V (0.1 V step) |
| External Bias Delay | 0–1000 µs adjustable |
| Detector Options | CCD area detector, single-photon counting module (SPCM), time-resolved multichannel acquisition module |
| Optional Accessories | Integrating sphere, device fixture, pulsed laser source (for TR-PL) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | FluoroLog-QM |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Dispersion Elements | Dual-grating monochromator with motorized filter wheels |
| Spectral Slit Width (Spectral Bandpass) | 0.01 nm |
| Optical Resolution | 0.1 nm |
| Sensitivity (Water Raman SNR) | 35,000:1 |
| Wavelength Accuracy | ±0.3 nm |
| Excitation Sources | Continuous Xenon lamp, Pulsed Xenon lamp, CW and Pulsed Lasers (210–2200 nm coverage via modular coupling) |
| Brand | Orient KOJI |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QY-2000 |
| Price Range | USD 28,000–42,000 |
| Dispersion Unit | Grating + Bandpass Filters |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Slit/Spectral Bandwidth | CCD Detector (Fixed Optical Resolution) |
| Resolution | 1.2 nm |
| Sensitivity | >500:1 (S/N) |
| Wavelength Accuracy | ±0.2 nm |
| Excitation Sources | Tunable Xenon Lamp + Selectable LEDs (254 nm, 395 nm, 450 nm, 460 nm) |
| Detection Range | 250–850 nm |
| Integrating Sphere | PTFE-coated interior, <1% port loss, sample port diameter <8 mm |
| Dynamic Range | 7000:1 |
| PLQY Reproducibility | ±1% (mean deviation) |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Model | DeltaFlex |
| Dispersion Element | Grating |
| Instrument Type | Transient Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 1–64 nm |
| Resolution | 1 nm |
| Sensitivity | >3000:1 |
| Wavelength Accuracy | ±0.05 nm |
| Excitation Source | Pulsed Laser Diode / LED System |
| Lifetime Range | <5 ps – 1 s |
| Minimum Acquisition Interval | 1 ms |
| Dead Time | 10 ns |
| Standard Detector | Picosecond PPD Module |
| Optional NIR Detection | up to ~1700 nm |
| Spectral Coverage | 200–1600 nm (with aberration-corrected gratings) |
| Sample Volume | as low as 1 µL |
| Software | Lifetime analysis suite with ≥5-exponential fitting, FRET, anisotropy, and decay-associated spectra (DAS) modules |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | HCLUE |
| Pricing | Available Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | LabRAM XploRA INV |
| Instrument Type | Inverted Confocal Raman Microscope |
| Laser Options | 532 nm, 638 nm, 785 nm (multi-laser auto-switching) |
| Grating Options | 4 gratings auto-switched (600, 1200, 1800, 2400 gr/mm) |
| Spectral Range | 250–10,000 cm⁻¹ (configurable per laser/grating combination) |
| Spatial Resolution | Sub-micron (diffraction-limited, dependent on objective and wavelength) |
| Automation | Auto-focus, auto-exposure, auto-calibration, self-diagnostic |
| Software Compliance | FDA 21 CFR Part 11-ready audit trail, GLP/GMP-supportive workflow logging |
| Optional Modules | DuoScan™ high-speed Raman imaging, SWIFT™ fast spectral acquisition, epifluorescence integration, polarization control, precision XYZ stage, environmental stages (cryo/heated/biological incubation), AFM-Raman coupling interface |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | LabRAM HR Evolution |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | 0.6 cm⁻¹ |
| Spatial Resolution | 400 nm |
| Low-Wavenumber Limit | 10 cm⁻¹ |
| Spectral Reproducibility | ±0.2 cm⁻¹ |
| Focal Length | 800 mm |
| Excitation Wavelength Range | 200–2100 nm |
| Detector | Research-Grade Air-Cooled Large-Format CCD |
| Optical Design | Achromatic Flat-Field Spectrograph |
| Brand | ID Quantique |
|---|---|
| Origin | Switzerland |
| Model | ID Qube NIR (Gated) |
| Detection Wavelength Range | 900–1700 nm |
| Gating Frequency | Up to 100 MHz |
| Dark Count Rate | <800 cps (at 10% detection efficiency) |
| Timing Resolution (Jitter) | 150 ps |
| Quantum Efficiency | up to 25% at 1550 nm |
| Cooling | Thermoelectric (TEC) |
| Coupling Options | Free-space, SMF-28, or multimode fiber |
| Operating Mode | Gated and free-running |
| Active Area | Standard InGaAs/InP APD |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | T64000 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Resolution (Additive Mode) | 0.15 cm⁻¹ |
| Low-Wavenumber Limit (Subtractive Mode) | 5 cm⁻¹ |
| Focal Length (Single Stage) | 640 mm |
| Total Focal Length (Triple Additive) | 3 × 640 mm |
| Excitation Range | UV–VIS–NIR |
| Detector | Research-Grade Air-Cooled Large-Format CCD |
| Optical Output | Flat-Field Spectral Dispersion |
| Laser Power Control | Multi-Step Attenuation Wheel |
| Configuration Options | Confocal Microscopy & Macro Sample Chamber |
| Polarization Compatibility | Full-Line (Excitation, Raman, White Light) |
| Optional Detectors | Secondary Output Port for PL or NIR Raman |
| Brand | Orient KOJI |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LN2030 |
| Capacity | 150 mL |
| Compatible Instruments | HORIBA FluoroMax, HORIBA Jobin Yvon, EDI, HITACHI F-7000/F-4600 series fluorescence spectrometers |
| Included Components | Vacuum-insulated dewar vessel, standard NMR tube (5 mm OD), adjustable dewar support stand (customizable), light-blocking cylindrical sleeve |
| Pricing | USD 4,200 (FOB Tianjin) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | iHR320 / iHR550 |
| Focal Length | 320 mm (iHR320), 550 mm (iHR550) |
| f-number | f/4.1 (iHR320), f/6.4 (iHR550) |
| Spectral Resolution | 0.06 nm (iHR320), 0.025 nm (iHR550) |
| Linear Dispersion | 2.31 nm/mm (iHR320), 1.34 nm/mm (iHR550) |
| Grating Size | 68 mm × 68 mm (iHR320), 76 mm × 76 mm (iHR550) |
| Stray Light | 1.5×10⁻⁴ (iHR320), 1.0×10⁻⁵ (iHR550) |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Model | DeltaPro |
| Dispersion Element | Grating and Interference Filters |
| Slit Width (Spectral Bandpass) | 1.0 nm to 32 nm |
| Optical Resolution | 1.0 nm |
| Sensitivity | >3000:1 |
| Wavelength Accuracy | ±0.5 nm |
| Detector Range (Standard) | 185–650 nm (upgradable to 850 nm or 900 nm) |
| Minimum Measurable Lifetime | 25 ps (with DeltaDiode/NanoLED) |
| Lifetime Range | 25 ps to 1 s (software-selectable source-dependent) |
| Excitation Sources | DeltaDiode (UV–NIR, 10 kHz–100 MHz rep. rate), NanoLED (UV–VIS, 10 kHz–1 MHz), SpectraLED (VIS–NIR, 0.1 Hz–10 kHz) |
| System Response FWHM | <200 ps (PPD/TBX + laser diode) |
| Dead Time | 10 ns |
| Time Range | 10 ns to 11 s (DeltaPro-DD configuration) |
| Interface | USB 2.0 (no PCI card required) |
| Operating System | Windows XP/7 (32-/64-bit English) |
| Dimensions (L×W×H) | 1875 mm × 1125 mm × 625 mm (excl. PC) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Instrument Type | Imported |
| Model | AquaLog |
| Wavelength Range (Excitation) | 200–800 nm |
| Wavelength Range (Emission) | 250–800 nm |
| Wavelength Range (Absorption) | 230–800 nm |
| Excitation Monochromator | Dual-grating with automatic order-sorting filter wheel |
| Emission Monochromator | CCD-based spectrometer with 405 g/mm grating (blazed at 250 nm) |
| Spectral Bandwidth (Slit) | 5 nm |
| Spectral Resolution | 0.41 nm/pixel (configurable to 0.82, 1.64, 3.28 nm/pixel) |
| Wavelength Accuracy | ±1 nm |
| Signal-to-Noise Ratio | >20,000:1 (RMS, 350 nm excitation, water Raman peak) |
| Full EEM Acquisition Time | 30 s |
| Full Emission Spectrum Readout Time | 5 ms |
| Detector | TE-cooled back-illuminated CCD |
| Built-in Corrections | Dark current, excitation source drift, excitation/emission spectral response, inner-filter effect, 1st/2nd-order Rayleigh scatter zeroing, Raman peak subtraction |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | PP-TOFMS |
| Acquisition Rate | 1 spectrum per 30 µs |
| Mass Resolution | 5,000 at m/z 208 (high-resolution mode) |
| Dynamic Range | 10⁷ |
| Mass Accuracy | ±40 ppm |
| Sensitivity | 10³ cps/ppm |
| Depth Resolution | down to 1 nm |
| Ion Modes | Positive and Negative |
| Flexible Ion Gating | up to 4 ions |
| Sample Loading | Horizontal, tool-free |
| Mass Coverage | H to U, including isotopes and molecular species |
| RF Pulsed Glow Discharge Mode | Patented |
| Quantitative Capability | Matrix-effect-minimized semi-quantitative depth profiling without calibration standards |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | HE |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Excitation Wavelength Options | 532 nm / 633 nm / 785 nm |
| Spectral Range | 200–3200 cm⁻¹ |
| Detector | 1024 × 256 CCD array, MPP mode |
| Cooling | Peltier-cooled to −70 °C (air-cooled, no water required) |
| Read Noise | < 8 e⁻/pixel |
| Dark Current | < 0.01 e⁻/pixel/s |
| Laser Power Range | 80–300+ mW |
| Power Supply | 220 V, 15 A |
| Software | LabSpec 6 (Windows-compatible) |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Model | DeltaHUB |
| Core Technology | Time-Correlated Single-Photon Counting (TCSPC) |
| Lifetime Range | 25 ps – 11 s (source-dependent) |
| Excitation Sources | 100 MHz Deltadiode ps-Laser, NanoLED, or SpectraLED |
| Detector | Picosecond Photon-Counting Detector |
| Integrated Platform | TCSPC-HUB Workstation |
| Optional Accessories | Monochromator for Time-Resolved Emission Spectra (TRES), Liquid Nitrogen Cryostat, 400 MPa High-Pressure Liquid Cell |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | FluoroMax+ |
| Dispersion Element | Holographic Grating |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 0.05–30 nm |
| Spectral Resolution | ≤0.2 nm |
| Sensitivity (S/N Ratio) | >16,000:1 (water Raman, 5 nm bandwidth, 1 s integration, no order-sorting filters) |
| Wavelength Accuracy | ±0.5 nm |
| Excitation Sources | 150 W Ozone-Free Xenon Lamp, Flash Xenon Lamp, Pulsed Laser Options |
Show next