| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Orion 3150 |
| Measurement Parameters | Total Phosphorus (TP) and Total Nitrogen (TN) |
| Instrument Type | Online Analyzer |
| Measurement Principle | Spectrophotometry (UV-Vis) |
| Measurement Ranges | 0–2 mg/L, 0–10 mg/L, 0–50 mg/L (auto-ranging) |
| Accuracy | ±5% of reading |
| Detection Limit | 0.005 mg/L |
| Resolution | 0.01 mg/L |
| [Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 320D-01 |
| Price | Upon Request |
| DO Range | 0.00–90.0 mg/L |
| DO Resolution | 0.1 / 0.01 mg/L |
| DO Saturation Range | 0.0–600% |
| DO Saturation Resolution | 1 / 0.1% |
| DO Accuracy | ±0.5% ±1 digit |
| Salinity Compensation | 0–45 ppt |
| Barometric Pressure Range | 450–850 mmHg |
| Calibration Modes | Water-saturated air, air-saturated water, Winkler titration zero-point |
| Electrode Type | Polarographic membrane electrode |
| Temperature Range | −5 to 105°C |
| Temp Resolution | 0.1°C (−5 to 99.9°C), 1.0°C (>99.9°C) |
| Temp Accuracy | ±0.1°C |
| Temp Compensation | Automatic/manual |
| Display | Backlit LCD |
| Sensor Interfaces | DO-miniDIN, Temp-miniDIN, Stirrer-phone jack (benchtop only) |
| Communication | Bidirectional RS232, optional USB cable |
| GLP Features | 200 data points, last 10 calibrations stored, 10 user methods, self-test diagnostics, password protection, network-enabled firmware/method updates |
| Power | 4×AA batteries |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45°C, 5–85% RH |
| IP Rating | Benchtop—IP54 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 410D-01 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 410P-01 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 420D-01 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | 420P-01 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 510M-01 (Benchtop), 520M-01 (Portable) |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | Orion 7070iX TRO |
| Price | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Model | Orion 8010cX |
| Instrument Type | Online Analyzer |
| Measurement Principle | Salicylate Spectrophotometry |
| Measurement Ranges | (0.02–2) mg/L |
| Accuracy | ±3% of reading ±0.04 mg/L (0.02–2 mg/L) |
| Detection Limit | 0.02 mg/L |
| Analysis Time | ≤30 min |
| Resolution | 0.001 mg/L (<100 mg/L) |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Sample Flow Rate | 50–1000 mL/min |
| Sample Pressure | 1–5 bar |
| Sample Temperature | 5–50 °C |
| Sample pH | 4–9 |
| Max. Turbidity (NTU) | <30 |
| Max. Color (Pt-Co) | <180 |
| Enclosure Rating | IP65 |
| Dimensions (W×H×D) | 450 × 737 × 322 mm |
| Weight | 40 kg |
| Power Supply | 100–240 VAC, 100 W, 50/60 Hz |
| Analog Outputs | Two 4–20 mA (max. 900 Ω load) |
| Digital Interface | RS485 |
| Relay Outputs | Two dry contacts (2 A @ 250 VAC) |
| Regulatory Compliance | cTUVus, CB, CE-LVD, RCM, FCC, CE-EMC, CE-RoHS, REACH, China RoHS |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Orion 8010cX |
| Instrument Type | Online Analyzer |
| Measurement Principle | Salicylate Spectrophotometry |
| Measurement Ranges | 0.02–2 mg/L |
| Accuracy | ±3% of reading + 0.04 mg/L (0.02–2 mg/L) |
| Detection Limit | 0.02 mg/L |
| Analysis Time | ≤30 min |
| Environmental Operating Temperature | 5–40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Sample Flow Rate | 50–1000 mL/min |
| Sample Pressure | 1–5 bar |
| Sample Temperature | 5–50 °C |
| Sample Requirements | TDS < 170 mg/L, TSS < 30 mg/L, pH 4–9, Color < 180 Pt-Co units |
| Enclosure Rating | IP65 |
| Dimensions (W×H×D) | 450 × 737 × 322 mm |
| Weight | 40 kg |
| Power Supply | 100–240 VAC, 100 W, 50/60 Hz |
| Analog Outputs | Two 4–20 mA (max. 900 Ω load) |
| Digital Interface | RS485 |
| Relay Outputs | Two dry contacts (2 A @ 250 VAC) |
| Regulatory Compliance | cTUVus, CB, CE-LVD, RCM (safety) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Orion 8030cX |
| Instrument Type | Online Analyzer |
| Measurement Principle | Heteropoly Molybdenum Blue Colorimetry |
| Detection Range | 0–5000 µg/L SiO₂ |
| LOD | <0.5 µg/L (typical, phosphate-compensated) |
| Enclosure Rating | IP65 |
| Reagent Replacement Interval | ≤100 days |
| User Interface | Capacitive Touchscreen Display |
| Platform Compatibility | Orion 8000 Series Multi-Parameter Platform |
| Compliance | Designed for GLP/GMP-aligned operation |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | ISE Series |
| Instrument Category | Multi-Ion Analyzers |
| Compliance | ASTM D1129, ISO 10523, USP <798>, EPA Method 300.0, EN ISO 10304-1 |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A113, A123 |
| Pricing | Available Upon Request |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A323 |
| Instrument Type | Portable |
| Measurement Principle | Polarographic & Optical (RDO) Fluorescence |
| DO Concentration Range | 0–90 mg/L (Polarographic), 0–50 mg/L (RDO) |
| DO Saturation Range | 0–600% (Polarographic), 0–500% (RDO) |
| Accuracy | ±0.001 pH / ±0.1 mV / ±0.2 mg/L (Polarographic, 0–20 mg/L) / ±0.1 mg/L (RDO, 0–8 mg/L) |
| Resolution | 0.001 pH / 0.1 mV / 0.01 mg/L (DO) |
| Temperature Range | 0–50 °C |
| Atmospheric Pressure Compensation | 450.0–850.0 mmHg |
| Salinity Compensation | 0–45 ppt |
| Data Storage | 5000 entries with timestamp, sample ID, user ID, calibration data |
| Compliance | GLP-compliant data logging, FDA 21 CFR Part 11-ready software support |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A329 |
| Instrument Type | Portable Multiparameter Water Quality Analyzer |
| Compliance | GLP-Compliant Data Logging (5000 Entries) |
| Protection Rating | IP67 |
| Power | 4×AA Batteries or AC Adapter |
| Connectivity | USB & RS232 |
| Software Support | Orion™ Comli Software (FDA 21 CFR Part 11 Ready) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Line | Orion Star LogR Series |
| Model | LogR pH/ISE |
| Measurement Principle | Potentiometric (Glass Electrode + ISE) with LogR™ Membrane Resistance-Based Temperature Sensing |
| Compliance | ASTM D1293, ISO 10523, USP <791>, EPA Method 150.1, GLP-Ready |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Star RDO |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Thermo Scientific TSSEPC510 |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | Thermo Scientific Water Quality Analyzer |
| Instrument Type | Laboratory Water Quality Analyzer |
| Price Range | USD 70,000 – 98,000 (based on configuration and regional import duties) |
| Key Compliance | ASTM D1293, ISO 7888, ISO 5667-3, USP <643>, EPA Methods 4500-OC, 4500-BOD, 4500-P, 4500-Cl⁻ |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Thermo Scientific™ TSTIO1000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Electrochemical Sensing (pH & residual chlorine), 90° Nephelometric Light Scattering (turbidity) |
| Measured Parameters | pH, Residual Chlorine, Turbidity, Temperature |
| Range | 0.01–20 ppm (residual chlorine) |
| Accuracy | ±0.01 ppm or ±2% of full scale (residual chlorine) |
| Repeatability | ≤2% RSD |
| Resolution | 0.01 ppm (residual chlorine) |
| Detection Limit | 0.01 ppm (residual chlorine) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Thermo Scientific™ TSTIO1000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Electrochemical Sensing (pH & residual chlorine) + 90° Nephelometric Light Scattering (turbidity) |
| Measured Parameters | pH, Residual Chlorine, Turbidity, Temperature |
| Measurement Range | Residual Chlorine: 0.01–20 ppm |
| Accuracy | ±0.01 ppm or ±2% of Full Scale |
| Repeatability | ±2% |
| Resolution | 0.01 ppm |
| Detection Limit | 0.01 ppm |
| Brand | TIANER |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TE-1050 |
| Instrument Type | Portable |
| Measurement Principle | Ultraviolet Fluorescence Spectrophotometry |
| Measurement Range | 40 ppb – 100 ppm |
| Detection Limit | 5 ppb |
| Accuracy | < ±5% |
| Resolution | 0.001 ppm |
| Measurement Cycle | 5 seconds per analysis |
| Brand | TIANER |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TE-2000 |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Flow-through Microbial Electrode Method |
| Measurement Range | 2–4000 mg/L |
| Detection Limit | 2 mg/L |
| Accuracy | ≤5% |
| Single-sample Measurement Time | 8 min |
| Repeatability | 3% |
| Sample Volume | 50 mL |
| Operating Ambient Temperature | 5–40 °C |
| Data Storage Capacity | 1,000,000 records |
| Display | 8-inch Color TFT Touchscreen |
| Communication Interfaces | USB, RS-232 |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 530 × 360 × 200 mm |
| Microbial Membrane Shelf Life | ≥30 days post-activation (1-year unopened warranty) |
| Oxygen Supply | Liquid-permeation-resistant automatic oxygenation design |
| Brand | Tianer |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TE-5002 |
| Measurement Parameters | Total Phosphorus (TP) and Total Nitrogen (TN) |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Spectrophotometry (for TP/TN digestion–colorimetric method) |
| Measurement Range | 0–100 mg/L for both TP and TN |
| Accuracy | ≤ ±5% |
| Detection Limit | 0.01 mg/L |
| Resolution | 0.001 mg/L |
| Repeatability | ≤ ±2% |
| Optical Stability | ≤ ±0.005 Abs/20 min |
| Optical System | Fiber-optic Photometric Detection |
| Light Source | Imported Cold Light LED (Lifespan > 100,000 h) |
| Display | 8-inch HD Capacitive Touchscreen |
| Interface Language | Default Chinese |
| Detection Modes | Rotating Cuvette (360°), 10 mm & 30 mm Cuvette, Digital Electrode Ports (2 independent) |
| Readout Modes | Concentration (mg/L), Absorbance (Abs), Transmittance (%) |
| Calibration | Single-point and Multi-point Calibration |
| Pre-stored Curves | 180 Method-Specific Calibration Curves (incl. EPA, ISO, and HJ standards) |
| Data Storage | Up to 1,000,000 Records with Timestamp, Sample ID, Operator ID, and Method Tag |
| Data Export | USB Port + Built-in Thermal Printer |
| Housing Material | Flame-Retardant ABS with Corrosion-Resistant Surface Finish |
| Dimensions (W×D×H) | 392 × 315 × 170 mm |
| Weight | 4.4 kg |
| Brand | TIANER |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | TE-5105G |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Colorimetric Method (Nessler Reagent Spectrophotometry) |
| Measurement Range | 0.01–150 mg/L (multi-range segmented calibration) |
| Accuracy | ≤ ±5% |
| Detection Limit | 0.01 mg/L |
| Measurement Time | 15–20 min per batch |
| Throughput | 5 simultaneous sample positions |
| Optical System | Fiber-optic spectrophotometric system |
| Light Source | Imported 12 V / 20 V halogen lamp (rated lifetime ≥ 100,000 h) |
| Wavelength | 420 nm |
| Reference Channel | Fixed automatic reference channel |
| Repeatability | ≤ ±2% |
| Inter-channel Variation | ≤ ±2% |
| Display | 7-inch color TFT capacitive touchscreen |
| Sample Introduction | Automated multi-channel sampling module |
| Sample Formats | Pre-filled colorimetric tubes (liquid reagents) and cuvettes (powder reagents) |
| Data Storage | Up to 1,000,000 measurement records with timestamp, sample ID, and operator log |
| Preloaded Calibration Curves | 180 factory-validated curves (user-modifiable, extensible, and recalibratable) |
| Auto-calibration | Built-in self-calibration routine using reference standards |
| Data Output | Integrated thermal printer |
| Connectivity | USB 2.0 port + RS-232 serial interface |
| Compliance | Fully aligned with HJ 535–2009 “Water Quality — Determination of Ammonia Nitrogen — Nessler Reagent Spectrophotometric Method” |
| Brand | TIANER |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Measurement Principle | Rapid Digestion Spectrophotometry (Lab-Grade) |
| Wavelength Range | 340–900 nm |
| COD Range | 2–20,000 mg/L |
| Accuracy | ≤ ±5% |
| Repeatability | ≤ ±2% |
| LOD | 0.01 mg/L |
| Digestion Time | 30 min |
| Batch Capacity | 8 samples |
| Display | 7-inch color capacitive touchscreen |
| Data Storage | 1,000,000 measurement records |
| Preloaded Calibration Curves | 1,000 |
| Optical System | Fiber-optic detection with imported cold-light source (≥100,000 h lifetime) |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 4 nm |
| Resolution | 0.001 AU |
| Dual-Zone Digestion Block | 8-position, independently controlled (0–200 °C) |
| Power | Integrated 40,000 mAh Li-ion battery |
| Connectivity | USB, RS232, optional Bluetooth |
| Compliance | ISO 9001 & ISO 14001 certified |
| Software | Proprietary water quality analysis platform (registered copyright) |
| Brand | Tianhe (Shandong Tianhe Instrument Co., Ltd.) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TH-SS15S |
| Detection Principle | Chlorophyll-a Fluorescence Method |
| Measurement Range | 0–400 µg/L |
| Resolution | 0.01 µg/L |
| Accuracy (Linearity) | R² > 0.999 |
| Temperature Compensation | Automatic |
| Self-Cleaning Function | Integrated Brush-Based Cleaner with Configurable Interval & Cycles |
| Power Consumption | 0.7 W (Operating), 0.4 W (Standby) |
| Supply Voltage | DC 12–24 V |
| Output Interface | RS-485 (Modbus RTU Protocol) |
| Storage Temperature | –5 to 65 °C |
| Operating Environment | 0 to 50 °C, < 0.2 MPa |
| Installation | Submersible, 3/4″ NPT Thread |
| Cable Length | 5 m |
| Protection Rating | IP68 |
| Housing Material | 316L Stainless Steel |
| Calibration Method | Two-Point (Zero & Span) via PC Software or Modbus Commands |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-W800 |
| Instrument Type | Portable Automatic Water Sampler |
| Sampling Method | Exceedance-Based Retention Sampling |
| Single Sample Volume | 10–1000 mL |
| Sampling Volume Accuracy | ±5% |
| Bottle Capacity | 1–24 Vials |
| Communication Interface | RS-232 |
| Remote Control | GPRS-enabled with Centralized Monitoring Platform |
| Power Failure Recovery | Yes (non-volatile parameter retention) |
| Data Notification | SMS alert capability |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | TH-ZX100 |
| Price Range | USD 7,000–14,000 (FOB) |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Range | 0–10 mg/L as O₂ |
| Repeatability | ±3% FS |
| Accuracy | ±5% FS |
| LOD | 0.5 mg/L |
| Resolution | 0.01 mg/L |
| Analysis Time per Sample | 30 min |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | TH-ZX200 |
| Price Range | USD 14,000–21,000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Ion-Selective Electrode (ISE) Method |
| Measurement Range | 0–50 mg/L and 0–300 mg/L (dual-range auto-switching) |
| Accuracy | ±10% of reading |
| Detection Limit | 0.05 mg/L |
| Cycle Time | 10 minutes per measurement |
| Sample Throughput | 10 samples per batch |