Water Quality Analysis
Filter
Showing 3001–3030 of 3684 results
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Scientific 3510VA |
| Instrument Type | Online Water Quality Analyzer |
| Analyte | Bromate |
| Detection Principle | Chronopotentiometric Anodic Stripping |
| Electrode Material | Mercury-Free Solid-State Working Electrode |
| Sample Throughput | Up to 6 analyses/hour |
| Detection Limit | Sub-µg/L range (typical for bromate in drinking water) |
| Compliance | Designed for EPA Method 300.1 / ISO 10304-4 / ASTM D808–22 context |
| Software | Embedded Windows CE with GLP-compliant data logging |
| Power | 100–240 VAC, 50/60 Hz |
| Environmental Rating | IP54 enclosure |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific 3510VA |
| Instrument Type | Online Water Quality Analyzer |
| Analyte | Bromate |
| Detection Principle | Chronopotentiometric Anodic Stripping Voltammetry (ASV) |
| Electrode System | Mercury-free, non-plated solid working electrode |
| Sample Throughput | Up to 6 analyses per hour |
| Detection Limit | Sub-µg/L range (typical for bromate in drinking water matrices) |
| Compliance | Designed for EPA Method 300.1 and ISO 10304-3 compatibility |
| Software Interface | Embedded web-based UI with bilingual (English/Chinese) support |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | IP54 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Thermo Scientific 6800 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific 6800 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific Alpha |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Thermo Scientific AM16 |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | Thermo Scientific AnalogPlus |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | APDPHYL500 |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific APDSOIL |
| Instrument Category | Online Analyzer |
| Measurement Principle | Ultraviolet Fluorescence (UVF) |
| Measurement Ranges | 0.1–10 ppm, 0.2–100 ppm, 1–1000 ppm |
| Detection Limits | 0.1 ppm, 0.2 ppm, 1 ppm |
| Accuracy | ≤3% |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Thermo Scientific AQ4700 |
| Instrument Type | Online |
| Biological Indicator | Bioluminescent Bacteria |
| Detection Time | 5 min |
| Compliance | ISO 11348 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific AQ4700 |
| Instrument Category | Online |
| Biological Indicator | Bioluminescent Bacteria |
| Detection Time | 5 min |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Thermo Scientific AquaClear |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Parameter | Turbidity |
| Compliance | Meets and exceeds USEPA Method 180.1 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Model | 3110TP |
| Application | Online Water Quality Monitoring |
| Measured Parameter | Total Phosphorus (TP) |
| Measurement Range | 0–1 / 0–2 / 0–10 / 0–50 mg/L |
| Accuracy | <5% for standard solutions |
| Detection Limit | 0.01 mg/L |
| Resolution | < ±5% of Full Scale |
| Instrument Type | Online Automated Analyzer |
| Compliance Context | Designed for continuous operation in compliance with ISO 15681-1 (Water quality — Determination of phosphorus — Part 1: Spectrophotometric determination after digestion) and supports GLP/GMP data integrity requirements via audit-trail-capable software |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | 3110TP |
| Measurement Parameter | Total Phosphorus (TP) |
| Instrument Type | Online Analyzer |
| Measurement Principle | Acid Digestion + Molybdenum Blue Colorimetry |
| Measurement Ranges | 0–1 / 0–2 / 0–10 / 0–50 mg/L as P |
| Accuracy | <5% for standard solutions |
| Detection Limit | 0.01 mg/L |
| Resolution | < ±5% of Full Scale (F.S.) |
| Repeatability | <5% of reading |
| Data Storage Capacity | 20,000 records with auto-rollover |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Enclosure Rating | IP66 / NEMA 4X |
| Dimensions (W×H×D) | 510 × 775 × 330 mm |
| Weight | 40 kg (instrument only) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | AquaEZ 3130 COD |
| Instrument Type | Online Analyzer |
| Wavelength | 450 nm |
| Measurement Range | 10–4000 mg/L |
| Accuracy | ±10% of reading (for samples >100 mg/L) |
| Repeatability | <5% of reading |
| Limit of Detection | 15 mg/L |
| Analysis Time | 45 minutes per cycle |
| Batch Capacity | 30 samples per 30-minute interval |
| Zero Drift | ≤5 mg/L |
| Protection Rating | IP65 / NEMA 4 |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (W×H×D) | 510 × 775 × 330 mm |
| Weight | 40 kg (excluding reagents) |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Output Interfaces | Dual 4–20 mA analog outputs, RS232 standard, RS485 optional |
| Digital I/O | 2 digital inputs, 8 digital outputs |
| Calibration Modes | Automatic scheduled, manual, and external-triggered |
| Data Storage | Up to 2 years of time-stamped measurement history with event tagging (M = maintenance, D = fault, C = calibration) |
| Display | Color LCD screen showing real-time results, calibration curves, and historical trends |
| Digestion Conditions | 165 °C, duration adjustable from 10–30 minutes |
| Measurement Modes | Continuous, periodic, timed, or external signal-triggered |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific AquaOZ |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Application | Real-time Dissolved Ozone Monitoring in Process Water Streams |
| Electrode Technology | Clark-type Amperometric Three-Electrode Sensor System |
| Controller Platform | AquaPro Multi-Channel Process Controller (up to 4 channels) |
| Data Logging Capacity | 1,000 data points with USB export |
| Firmware Update | USB-port field-upgradable |
| Language Support | 6 languages including English, Chinese, Spanish, French, German, and Portuguese |
| Membrane Assembly | Pre-filled, disposable membrane cap with electrolyte |
| Temperature Compensation | High-accuracy integrated Pt1000 RTD sensor |
| Housing Material Options | PVC, PVDF, 316L SS, and Hastelloy C-276 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | AquaPro Five-Parameter System |
| Instrument Type | Online Monitor |
| Temperature Range | –5 to 95 °C |
| pH Range | 0.00–14.00 pH |
| Dissolved Oxygen Range | 0.00–20.00 ppm (0–50 °C) |
| Conductivity Range | 0–2000 µS/cm |
| Turbidity Range | 0–4000 NTU (–5 to 50 °C) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific AquaPro RDO |
| Instrument Category | Online Dissolved Oxygen Analyzer |
| Measurement Principle | Fluorescence Quenching |
| Range | 0–20 ppm / 0–200% saturation |
| Accuracy | ±0.1 ppm (≤8 ppm), ±0.2 ppm (8–20 ppm) |
| Repeatability | ±5% |
| Detection Limit | 0.01 ppm or 0.1% saturation |
| Maintenance Interval | Fluorescence Cap Replacement Every 2 Years |
| Certification | CE Marked |
| Regulatory Compliance | Designed for compliance with ISO 5814:2012 (Water quality — Determination of dissolved oxygen — Electrochemical probe method), ASTM D888-22 (Standard Test Methods for Dissolved Oxygen in Water), and supports GLP/GMP data integrity requirements |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | AquaPro |
| Instrument Category | Online Water Quality Analyzer |
| Measurement Flexibility | Configurable Input Channels for Any Parameter |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Thermo Scientific AquaPro |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | DataStick Digital Sensor |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific AquaSensors |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | AquaTurb / AquaSol |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Turbidity, Suspended Solids (SS) Concentration |
| Optical Method | ISO 7027-compliant Nephelometric & Backscatter Detection |
| Light Source | Infrared LED (850 nm) |
| Detection Angles | 90° and 180° |
| Output | Digital (RS-485, Modbus RTU), Optional 4–20 mA Analog |
| Temperature Compensation | Integrated Pt1000 sensor |
| Enclosure Rating | IP68 |
| Cleaning Option | Optional Automatic Wiper or Air-Pulse Self-Cleaning Module |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Thermo Scientific MPC 20 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fluoride ISE (CS00F02) |
| Instrument Type | Fluoride Ion Selective Electrode |
| Measurement Range | 0.02 ppm to saturation |
| Compliance | ASTM D1129, ISO 10523, USP <771>, EPA Method 300.0 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Thermo Scientific Orion 2210AM |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric Method (Indophenol Blue) |
| Measurement Ranges | 0.01–2 mg/L, 0.05–10 mg/L, 0.5–50 mg/L, 5–500 mg/L (as N) |
| Accuracy | ±5% or ±0.01 mg/L (whichever is greater) within 0.01–50 mg/L |
| Detection Limit | 0.01 mg/L (as N) |
| Analysis Time | ≤30 minutes per cycle |
| Temperature Control | Integrated thermostatically controlled cuvette with magnetic stirring |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific Orion 2210AM |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric Method (Indophenol Blue Reaction) |
| Measurement Ranges | 0.01–2 mg/L, 0.05–10 mg/L, 0.5–50 mg/L, 5–500 mg/L (as N) |
| Accuracy | ±5% or ±0.01 mg/L (whichever is greater) within 0.01–50 mg/L |
| Detection Limit | 0.01 mg/L (as N) |
| Analysis Time | ≤30 minutes per cycle |
| Sample Throughput | Continuous online operation (no batch processing) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 310D-01 |
| Price | Upon Request |
| DO Range | 0.00–90.0 mg/L |
| DO Resolution | 0.1 / 0.01 mg/L |
| DO Saturation Range | 0.0–600% |
| Saturation Resolution | 1 / 0.1% |
| DO Accuracy | ±0.5% ±1 digit |
| Salinity Compensation Range | 0–45 ppt |
| Atmospheric Pressure Range | 450–850 mmHg |
| Calibration Modes | Water-saturated air, air-saturated water, Winkler titration zero-point |
| Electrode Type | Polarographic membrane sensor |
| Temperature Range | −5 to 105°C |
| Temp Resolution | 0.1°C (−5 to 99.9°C), 1.0°C (>99.9°C) |
| Temp Accuracy | ±0.1°C |
| Temp Compensation | Automatic/manual |
| Display | Backlit LCD |
| Sensor Interfaces | DO-miniDIN, Temp-miniDIN, Stirrer-phone jack (benchtop only) |
| Communication | Bidirectional RS232, optional USB cable |
| GLP Features | Data logging (200 entries), calibration history (last 10), method storage (10), self-test diagnostics, password protection, network-enabled firmware/software updates |
| Power | 4×AA batteries + universal AC adapter (benchtop) |
| Safety Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45°C, 5–85% RH |
| Enclosure Rating | IP54 (benchtop) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 310D-24 |
| Pricing | Upon Request |
| Conductivity Range | 0.000–3000 mS/cm |
| Conductivity Resolution | Up to 0.001 µS/cm (4 significant digits) |
| Conductivity Accuracy | ±0.5% of reading or ±0.01 µS/cm (whichever is greater) |
| Resistivity Range | 0.0001–100 MΩ·cm |
| Salinity Range | 0.01–80.0 ppt NaCl |
| TDS Range | 0–19,999 mg/L |
| Cell Constant Range | 0.001–199.9 cm⁻¹ |
| Reference Temperatures | 15°C, 20°C, or 25°C |
| Electrode Compatibility | Two-electrode, four-electrode, and planar conductivity cells |
| Calibration Points | 1–5 point |
| Temperature Range | −5°C to 105°C |
| Temperature Resolution | 0.1°C (−5°C to 99.9°C), 1.0°C (>99.9°C) |
| Temperature Accuracy | ±0.1°C |
| Temperature Compensation | Automatic or manual |
| Display | Backlit LCD |
| Sensor Interfaces | Conductivity – miniDIN |
| Communication | Bidirectional RS232, optional USB cable |
| Data Storage | 200 GLP-compliant measurements |
| Calibration History | Last 10 calibrations |
| Method Storage | 10 user-defined methods |
| Self-Diagnostic Function | Yes |
| Password Protection | Yes |
| Firmware/Method Update | Network-enabled |
| Power Supply | 4 × AA batteries or universal AC adapter (benchtop) |
| Safety Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45°C, 5–85% RH |
| Ingress Protection | IP54 (benchtop) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Orion 3150 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Spectrophotometry (UV-Vis) |
| Measuring Parameters | Total Phosphorus (TP) and Total Nitrogen (TN) |
| Range | 0–2 / 0–10 / 0–50 mg/L (user-selectable ranges per parameter) |
| Accuracy | ±5% of reading |
| Detection Limit | 0.005 mg/L |
| Resolution | 0.01 mg/L |
| Light Source (TN module) | Xenon flash lamp (rated for >10⁸ flashes) |
| Sample Handling | Integrated digestion-colorimetric cell with automated reagent dosing and thermal digestion |