Water Quality Analysis
Filter
Showing 2971–3000 of 3684 results
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Country of Origin | Imported |
| Model | VERSA STAR |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurable Parameters | pH, ISE (Ion Selective Electrode), Conductivity, Dissolved Oxygen (DO), Temperature |
| Compliance | GLP-Compliant Data Storage (2000 Records) |
| Connectivity | Dual USB + RS232 |
| Protection Rating | IP54 |
| Operating Modules | Up to 4 Simultaneous Modules |
| Stirrer Support | 2 Orion Star Stirrers (Hot-Swappable) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | RDO Pro |
| Price | Upon Request |
| Measurement Principle | Fluorescence Lifetime Quenching |
| Range | 0–20 ppm / 0–200% saturation |
| Resolution | 0.01 ppm (<10 ppm), 0.1 ppm (≥10 ppm) |
| Accuracy | ±0.1 ppm (<8 ppm), ±0.2 ppm (8–20 ppm) |
| Response Time | t₉₀ = 30 s, t₉₅ = 37 s |
| Units | ppm, % saturation, °C, °F |
| Calibration | Single-point air-saturation calibration |
| Compensation | Automatic temperature, barometric pressure, and salinity compensation |
| Operating Temperature | 0–50 °C |
| Max Pressure Rating | 300 PSIG (20.7 bar) at 50 °C |
| Flow Independence | Yes |
| Housing Materials | Delrin®, Polystyrene |
| Probe Dimensions | 203 mm length × 47 mm diameter |
| Threaded Mount | 1.25" NPT |
| Warranty | 2 years |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Thermo Scientific 1816DO |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Thermo Scientific 2103PH |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Industrial Online Conductivity Analyzer |
| Model | Thermo Scientific 2104CD |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Industrial Online Analyzer |
| Model | Thermo Scientific 2105AB |
| Output | 0–20 mA or 4–20 mA analog signal |
| Conductivity Range | 0–2,000,000 µS/cm |
| Concentration Range | 0–10% w/w (acid/base) |
| Temperature Compensation | High-accuracy automatic compensation |
| Fouling Resistance | Engineered for long-term stability in fouling-prone water streams |
| Calibration | User-definable multi-point calibration curves |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Thermo Scientific 2109XP |
| Detection Limit | 10 ppb F⁻ |
| Measurement Principle | Potentiometric using Solid-State Fluoride Ion-Selective Electrode (ISE) |
| Display | Backlit LCD |
| Calibration Method | Dual-Standard Known Addition (DKA) |
| Optional Channels | pH or Conductivity |
| Communication | Digital Modbus RS-485 / 4–20 mA analog output |
| Maintenance | No reagent pumps or moving parts |
| Compliance | Designed for continuous compliance monitoring per EPA Method 300.0 and ISO 10304-1 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific 2109XP |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific 2111AO |
| Instrument Category | Sodium Ion Analyzer |
| Installation Type | Online |
| Measurement Range | 1.0 ppb – 200 ppm Na⁺ |
| Response Time | ≤2 min to 95% of final value |
| Accuracy | ±5% of reading or ±2 ppb (whichever is greater) |
| Operating Temperature | 5–45 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific 2111EL |
| Instrument Category | Sodium Ion Analyzer |
| Installation Type | Online |
| Measurement Range | 0.001 ppb – 10 ppm |
| Response Time | ≤2 min to 95% of final value |
| Accuracy | ±5% of reading or ±0.1 ppb (whichever is greater) |
| Operating Temperature | 5–45 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific 2111ND |
| Instrument Category | Sodium Ion Analyzer |
| Installation Type | Online |
| Measurement Range | 0.10 ppb – 10 ppm |
| Response Time | ≤2 minutes to 95% of final value |
| Accuracy | ±5% of reading or ±0.1 ppb (whichever is greater) |
| Operating Temperature | 5–45 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Thermo Scientific 2116RDO |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 2117HL |
| Measurement Range | 75–1000 ppm Cl⁻ |
| Principle | Potentiometric measurement using solid-state chloride-selective electrode |
| Reagent-Free Operation | Yes |
| Display | Backlit LCD with graphical interface |
| Calibration Method | DKA (Dual-Point Known Addition) |
| Response Time (t₉₀) | < 2 minutes |
| Maintenance Requirements | No pumps, no reagents, no moving parts |
| Compliance | Designed for continuous industrial process monitoring in accordance with ASTM D4192, ISO 9297, and EPA Method 325B (adapted for on-line chloride detection) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Thermo Scientific 2117HL |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 2117LL |
| Detection Limit | 1.5 ppb Cl⁻ |
| Measurement Principle | Potentiometric Chloride-Selective Electrode (CSE) |
| Calibration | Dynamic 1–3-point calibration with integrated pH adjustment |
| Compliance | Designed for continuous online monitoring in high-purity water systems |
| Application Environment | Semiconductor-grade UPW, boiler feedwater, RO permeate, condensate, seawater-cooled condenser leak detection |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Thermo Scientific 2117LL |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Thermo Scientific 2117XP |
| Detection Limit | 0.1 ppm Cl⁻ |
| Measurement Principle | Potentiometric with Chloride-Selective Electrode (CSE) |
| Display | Backlit LCD |
| Calibration Method | DKA (Two-Point Known Addition) |
| Optional Channels | pH or Conductivity |
| Communication | Digital Module Support (RS-485/Modbus RTU) |
| Compliance | Designed for continuous online water quality monitoring in industrial process and utility applications |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Thermo Scientific 2117XP |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Thermo Scientific 2118XP |
| Type | Online Analyzer |
| Detection Range | 0–200 ppb |
| Sensor Principle | Iodide-Selective Electrode (ISE) |
| Display | Backlit LCD |
| Compliance | Designed for ASTM D4356, ISO 10523, and USP <645> water quality monitoring environments |
| Communication Options | Optional digital communication module (Modbus RTU/ASCII, 4–20 mA analog output) |
| Expandability | Optional second channel for pH or conductivity measurement |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific 2118XP |
| Instrument Category | Online Analyzer |
| Detection Range | 0–200 ppb |
| Sensor Principle | Iodide-Selective Electrode (ISE) with Onboard Reagent Dosing |
| Display | Backlit LCD |
| Calibration Interface | Guided On-Screen Calibration Workflow |
| Expandability | Optional dual-channel configuration (pH or conductivity), optional digital communication module (Modbus RTU/ASCII, 4–20 mA output) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Thermo Scientific 2120XP |
| Detection Limit | 25 ppb Ca²⁺ |
| Measurement Principle | Calcium-Selective Electrode (CSE) with pH-Buffered Sample Conditioning |
| Display | Backlit LCD |
| Calibration Method | Dual-Standard Known Addition (DKA) |
| Optional Channels | pH or Conductivity (second channel) |
| Communication | Digital I/O and Modbus RTU/ASCII support |
| Maintenance Design | No moving parts, no reagent pumps, no consumable dosing systems |
| Compliance | Designed for continuous operation in industrial water treatment environments per ASTM D1066 and ISO 5667-3 guidelines |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Thermo Scientific 2120XP |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 2240 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Gas-Sensing Electrode (Ammonia-Selective Electrode) |
| Measurement Range | 0–50.0 mg/L as NH₃–N |
| Accuracy | ±5% of reading or ±0.10 mg/L (whichever is greater) |
| Detection Limit | 0.001 mg/L |
| Analysis Time | <10 minutes per sample |
| Batch Throughput | <10 minutes per measurement |
| Display Interface | Bilingual (English & Chinese) |
| Communication Interfaces | Standard RS-232 and 0–20 mA analog output |
| Self-Diagnostics | Integrated system health monitoring |
| Flow Path | Patented corrosion-resistant fluidic architecture |
| Maintenance Automation | Programmable auto-cleaning and auto-calibration cycles |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 2240 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Ammonia Gas-Sensing Electrode Method |
| Range | 0–50.0 mg/L (as N) |
| Accuracy | ±5% of reading or ±0.10 mg/L, whichever is greater |
| Detection Limit | 0.001 mg/L |
| Analysis Time | <10 min |
| Calibration Time | <10 min |
| Resolution | 0.001 mg/L |
| Repeatability | ≤5% RSD |
| Calibration Mode | Automatic Two-Point Calibration |
| Sample Volume per Analysis | ~70 mL |
| Reagent Consumption per Analysis | ~0.5 mL |
| Output Signals | 4–20 mA, RS-232, RS-485 |
| Enclosure Mounting Options | Wall-Mounted or Freestanding |
| Dimensions (W×H×D) | 510 × 775 × 330 mm |
| Weight | ~25 kg (without reagents), ~40 kg (fully configured) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Thermo Scientific 3100 VA |
| Instrument Type | Online Water Quality Analyzer |
| Electrode Material | Mercury-Free Working Electrode |
| Measurement Principle | Chronopotentiometric Anodic Stripping Voltammetry (ASV) |
| Compliance | Designed for EPA Method 300.1 / ISO 10566 / ASTM D7282-18 compatibility |
| Software | Embedded OS with bilingual (English/Chinese) interface |
| Maintenance | Low-consumption flow-injection system with self-diagnostic and auto-recovery functions |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Thermo Scientific 3100 VA |
| Instrument Type | Online Water Quality Analyzer |
| Analyte | Bromate (BrO₃⁻) |
| Detection Principle | Chronopotentiometric Anodic Stripping Voltammetry (ASV) |
| Electrode Material | Mercury-Free Solid-State Working Electrode |
| Sample Throughput | Up to 6 analyses per hour |
| Detection Limit | Sub-µg/L range (typical for bromate in drinking water) |
| Compliance | Designed for compliance with US EPA Method 300.1, ISO 10304-2, and WHO Guideline Values for Bromate |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Thermo Scientific 3131 |
| Pricing | Available Upon Request |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Range | 0–20 / 0–100 / 0–200 mg/L KMnO₄ (customizable extended ranges available) |
| Repeatability | ≤ ±3% RSD |
| Accuracy | ±3% of reading |
| Limit of Detection (LOD) | ≤ 0.2 mg/L |
| Resolution | 0.001 mg/L |
| Analysis Time per Sample | < 60 minutes |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | Thermo Scientific 3131 |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Range | 0–20 / 0–100 / 0–200 mg/L (customizable extended ranges available) |
| Repeatability | ≤ ±3% |
| Accuracy | ±3% |
| Limit of Detection (LOD) | ≤ 0.2 mg/L |
| Resolution | 0.001 mg/L |
| Analysis Time per Sample | < 60 minutes |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Scientific 3300 |
| Instrument Type | Online Analyzer |
| Detection Principle | Photometric Method (Colorimetric) |
| Target Metals | Dual-Parameter / Multi-Parameter (e.g., Cd, Cr, Cu, Ni, Pb, Zn, As, Hg) |
| Accuracy/Precision | ±10% of Full Scale |
| Resolution | 0.001 mg/L (ppb-level configurable per analyte) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific 3300 |
| Instrument Category | Online Analyzer |
| Detection Principle | Photometric Method (Colorimetric) |
| Target Metals | Dual- or Multi-Parameter (e.g., Cu, Zn, Ni, Cr, Pb, Cd, As, Mn) |
| Accuracy/Precision | ±10% of Full Scale |
| Resolution | 0.001 mg/L (ppb-level configurable per analyte) |