| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Online TOC Analyzer |
| Price Range | USD 42,000 – 70,000 |
| Instrument Type | Online TOC Monitoring System |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Methods | UV/Persulfate, High-Temperature Combustion (680–900 °C), Ozone-Promoted Oxidation, Ultra-Pure UV Oxidation |
| Measurement Range | 0–50,000 ppm C |
| Accuracy | ±1% of reading |
| Resolution | 0.05 ppm C |
| Detection Limit | 0.05 ppm C |
| Repeatability | ±1% RSD |
| Sample Throughput | As low as 3 minutes per analysis (configuration-dependent) |
| Dimensions (H×W×D) | 575 × 556 × 612 mm |
| Weight | 60 kg |
| Power Supply | 220 VAC, 10 A |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | HACH Company |
| Model | Orbisphere 3650 / 3655 |
| Instrument Type | Portable |
| Measurement Principle | Polarographic Electrochemical Probe |
| Measurement Range | 0–20 ppm / 0–40 ppm / 0–8 ppm (configurable via membrane selection) |
| Accuracy | ±1% of reading |
| Detection Limit | <1 ppb |
| Temperature Range | –5 °C to 100 °C |
| Power Supply | Two AA NiCd or alkaline batteries (2.4–3 V DC) |
| Battery Life | Up to 40 hours continuous operation |
| Response Time | ≤3 minutes (from air saturation to 2 ppb) |
| Enclosure Rating | IP67 / NEMA 4 |
| Data Storage | Internal logging with RS232 digital interface |
| Maintenance Interval | Typically every 6 months |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Model | 3650EX |
| Power Supply | 2 × AA NiCd or alkaline batteries (2.4–3 V DC) |
| Battery Life | Up to 40 hours continuous operation |
| Measurement Principle | Electrochemical amperometric sensing with proprietary membrane-based sensor |
| Enclosure Rating | IP67 / NEMA 4X |
| Certification | ATEX II 1G Ex ia IIC T4 Ga |
| Temperature Range | –5 °C to +100 °C |
| Output Interface | RS-232 serial digital interface |
| Zero Drift | < 0.5 % FS per 24 h |
| Housing Material | Fully stainless steel (316L) |
| Data Logging | Internal non-volatile memory with PC download capability |
| Brand | HACH |
|---|---|
| Model | Orbisphere 3658 |
| Type | Online Dissolved Oxygen (DO) and Multi-Gas Analyzer for Water and Wastewater Applications |
| Origin | Switzerland (HACH, a Danaher company) |
| Manufacturer | HACH LANGE GmbH |
| Compliance | CE, RoHS, ATEX optional |
| Output Signals | 4–20 mA, Modbus RTU/ASCII, Ethernet/IP, PROFIBUS DP |
| Power Supply | 24 VDC or 100–240 VAC |
| Enclosure Rating | IP66/NEMA 4X |
| Brand | HACH |
|---|---|
| Model | Orbisphere 3660EX |
| Certification | ATEX II 1G Ex ia IIC T4 Ga |
| Enclosure Rating | IP67 / NEMA 4X |
| Construction | Full 316L stainless steel housing |
| Sensor Technology | Patented electrochemical (Clark-type or galvanic) cell |
| Power Supply | 2×AA NiCd or alkaline batteries (2.4–3 V DC) |
| Battery Life | Up to 40 hours continuous operation |
| Signal Drift | <0.5% FS/month |
| Temperature Range (Operation) | 0–45 °C |
| Temperature Range (Measurement) | –5–100 °C |
| Output Options | 4–20 mA, RS232, RS485 |
| Maximum Remote Display Distance | 1000 m (with 3662 display unit) |
| Sample Compatibility | Aqueous solutions, process streams, hazardous gas atmospheres (O₂, H₂, O₃) |
| Data Logging | Internal non-volatile memory with PC download capability |
| Brand | HACH |
|---|---|
| Model | Orbisphere 410/510 |
| Measurement Range | ppb to ppm |
| Resolution | 0.1 ppb |
| Accuracy | ±1 ppb |
| Response Time (t₉₀) | 7.2 s |
| Data Storage Capacity | 10,000 measurement records + 1,000 operator actions |
| Analog Outputs | 0/4–20 mA (standard), three 0–5 V (hardware-selectable) |
| Digital Interfaces | RS-485, PROFIBUS DP, USB, Ethernet |
| Sample Modes | Continuous and discrete sampling |
| Electrode Compatibility | Dual-channel for dissolved oxygen (O₂) and ozone (O₃) sensing |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 51X |
| Instrument Type | Online |
| Measurement Principle | Electrochemical (Clark-type and galvanic sensor compatible) |
| Measurement Range | 0.01 ppb to 20 ppm O₂ (configurable via sensor selection) |
| Accuracy | ±0.1 ppb or ±1% of reading, whichever is greater |
| Response Time (t₉₀) | ≤7.2 s |
| Data Storage Capacity | Up to 1,000 measurement records + 1,000 operator action logs |
| Analog Outputs | Three 4–20 mA (isolated, HART-compatible) + three 0–5 V (hardware-selectable) |
| Digital Communication | RS-485, PROFIBUS DP, USB, Ethernet |
| Sensor Compatibility | O₂, O₃, H₂ (via interchangeable electrochemical sensors) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer | Hach Company |
| Model | Orbisphere 6110 |
| Oxygen Range | 1–20 ppm |
| CO₂ Range | 0.75–5 %v/v or 1.5–10 g/kg |
| Repeatability (r₉₅ at 20±5°C) | TPO⁺: ±5 µg/L or ±10% (whichever is greater) |
| CO₂ | ±0.05 %v/v or ±0.10 g/kg or ±2% (whichever is greater) |
| Analysis Time | ~4 minutes |
| Sample Throughput | 12 samples/hour |
| Purge Gas | CO₂ ≥99.9% purity, 4–7 bar (58–102 psia) |
| Operating Temperature Range (Package) | −2–30°C |
| Operating Pressure Range (Package) | 1.4–6.8 bar |
| Ambient Temperature | 0–40°C |
| Package Height | 90–340 mm |
| Minimum Package Volume | 150 mL |
| Power Supply | 100/240 VAC ±10%, 50/60 Hz |
| Max Power Consumption | 250 VA |
| Enclosure Rating | IP20 |
| Compliance | Low Voltage Directive 2006/95/EC |
| EN 61326 | 2006 |
| Display | TFT VGA (640×480) color touchscreen |
| OS | Windows CE 4.2 |
| Interfaces | 1× USB Device, 2× USB Host, 1× Ethernet |
| Dimensions | 537×540×942 mm |
| Weight | 55 kg |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | ORBISPHERE G1100 |
| Measurement Principle | Fluorescence Quenching (Lifetime-Based) |
| Range | 0–20,000 ppb |
| Repeatability | ±1 ppb + 2% (0–600 ppb), ±2 ppb + 2.5% (0–600 ppb) |
| LOD | ±2 ppb |
| Response Time (t₉₀) | 30 s |
| Resolution | 1 ppb |
| Calibration | Fully Automated, User-Programmable Single-Point Zero Calibration with Certified N₂ (99.999%, Grade 5.0) |
| Validation | Automated Single-Point Zero Verification |
| Sample Temp. | 5–45 °C |
| Sensor Temp. Rating | −5–100 °C |
| Pressure Range | 1–4 bar abs |
| Flow Rate | 50–500 mL/min |
| Enclosure | Wall/Pipe-Mounted Stainless Steel or Panel-Mounted Aluminum, IP65 |
| Analog Outputs | 3 Smart 0/4–20 mA (500 Ω), Configurable for Linear/Tri-Linear Output or Diagnostic/Alarm Signals |
| Relays | 3 Measurement Alarms (2 A / 30 VAC or 0.5 A / 50 VDC), 1 System Alarm Relay |
| Communication | RS485, Optional Profibus DP or Ethernet, USB Client/Host |
| Data Storage | Rolling or One-Time Storage for up to 1,000 Measurements and 1,000 Operator Actions |
| Display | Monochrome STN LCD (320 × 240 px) with LED Backlight |
| Compliance | EN 61326 (EMC), EN 61010-1 (Safety), Directive 73/23/EEC |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Orbisphere GA2X00 |
| Measurement Principle | Electrochemical (Galvanic Cell) |
| Detection Limit | 0.1 ppb |
| Accuracy | ±1% of reading |
| Replaceable Membrane Cartridge | Yes, pre-assembled with membrane and electrolyte |
| Maintenance Time | <5 minutes |
| ATEX Certification | Yes (for GA2800 variant) |
| Application Fields | Beverage processing, boiler water monitoring, cooling water systems, industrial process water, ultrapure water (UPW) |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | HACH Company |
| Model | ORBISPHERE K1100 |
| Calibration Interval | Annual |
| Response Time | <2 seconds |
| Detection Limit | 0.6 ppb |
| Accuracy | ±0.8 ppb |
| Measurement Principle | Dynamic Luminescence Quenching (Cold Light Method) |
| Compatibility | ORBISPHERE 410 Controller, 28 mm insertion fittings, flow-through cells |
| Output Options | 3 configurable relays, 3 smart analog outputs |
| Diagnostic Capability | Real-time sensor health monitoring, predictive maintenance alerts |
| Brand | HACH |
|---|---|
| Model | OWF-100 |
| Measurement Principle | UV Fluorescence |
| Range | 0–2.0 mg/L and 0–10 mg/L (selectable) |
| Repeatability | ±7% FS |
| Stability | ±5% FS/day (in deionized water) |
| Response Time | T90 = 3 min |
| Sample Temperature | 0–30 °C |
| Sample Pressure | 0.02–0.3 MPa |
| Sample Flow Rate | 2–7 L/min |
| Ambient Operating Temperature | 0–45 °C |
| Analog Output | 4–20 mA, max. load 600 Ω |
| Power Supply | 220 VAC ±10%, 50/60 Hz |
| Power Consumption | ~50 VA |
| Dimensions (W×H×D) | 300 × 1500 × 500 mm |
| Weight | 40 kg |
| Installation | Indoor only |
| Optical Design | Windowless full-flow measurement cell |
| Maintenance | No moving parts, reagent-free operation |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | HACH Company |
| Model Numbers | LXV541.99.1001H, LXV541.99.2001H |
| Instrument Type | Online Analyzer |
| Measurement Principle | Ultraviolet Fluorescence (UVF) |
| Measurement Range | 0–900 µg/L as PAH-PHE (Phenanthrene Equivalent) |
| Limit of Detection (LOD) | 3 µg/L PAH |
| Accuracy | ±5% or ±5 µg/L (whichever is greater) under constant temperature and flow conditions |
| Excitation Wavelength | 370 nm |
| Measurement Interval | Every 20 seconds |
| Material | Titanium Alloy Housing |
| Turbidity Compensation | Yes |
| Controller Integration | Compatible with HACH sc Series Controllers |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | PCII |
| Weight | 230 g |
| Optical Range | 0–2.5 ABS |
| Operating Temperature | 10–50 °C |
| Relative Humidity | 0–90 % RH |
| Power | AAA alkaline batteries |
| IP Rating | Submersible up to 0.9 m for 30 min |
| Data Storage | 10 recent measurements |
| Display | Backlit LCD with battery indicator |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | PCII |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurable Parameters | Multiple (Single-Parameter Operation Mode) |
| Wavelength | Model-Dependent |
| Photometric Range | 0–2.5 ABS |
| Power Supply | AAA Alkaline Batteries (4×) |
| Weight | 230 g |
| Operating Environment | 10–50 °C, 0–90% RH (non-condensing) |
| IP Rating | IP67 (submersible up to 0.9 m for 30 min) |
| Data Storage | 10 recent measurements with timestamp |
| Display | Backlit LCD with battery level indicator |
| Calibration | Factory-calibrated against standardized methods (e.g., APHA, ASTM, ISO) |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Phosphax sc LR Low-Range Orthophosphate Online Analyzer |
| Instrument Type | Online Analyzer |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Phosphax sc |
| Instrument Type | Online Analyzer |
| Measurement Principle | Photometric Colorimetry (Vanadomolybdate Yellow Method) |
| Range | 0.05–15.0 mg/L PO₄–P (Range 1) |
| Detection Limit | 0.05 mg/L PO₄–P (Range 1) |
| Installation | In-situ or flow-through configuration |
| Controller Interface | Digital, plug-and-play sc-series controller |
| Optional Pre-treatment | Filterprobe sc |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Phosphax sc |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric (Ascorbic Acid Reduction Method) |
| Detection Limit | <0.01 mg/L PO₄–P |
| Range | 0–2.0 mg/L and 0–10.0 mg/L (selectable) |
| Response Time | <15 minutes (typical cycle time) |
| Output | 4–20 mA, Modbus RTU, Ethernet/IP |
| Sample Inlet | 6–10 bar pressure rating |
| Cleaning | Automatic air-pulse and brush-based cleaning system |
| Controller | Integrated digital sc controller (plug-and-play) |
| Optional Pre-treatment | Filterprobe sc suspended solids removal module |
| Compliance | Designed for continuous operation in wastewater treatment environments per ISO 5667-3, ASTM D515-88, and EN ISO 15681-1 |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Phosphax Sigma |
| Measurement Parameter | Total Phosphorus |
| Instrument Type | Online Analyzer |
| Measurement Principle | Spectrophotometric Method (Molybdenum Blue) |
| Measurement Range | Total Phosphorus: 0.01–5.0 mg/L as P |
| Accuracy | ±2% of reading |
| Detection Limit | 0.01 mg/L as P |
| Resolution | 0.01 mg/L as P |
| Orthophosphate Range | 0.01–5.0 mg/L as P |
| Cycle Time | ~10 minutes per analysis |
| Calibration | Automatic |
| Sample Flow Rate | 100 mL/h |
| Reagent Replacement Interval | Every 3 months |
| Output Signals | Two isolated 4–20 mA analog outputs (max. load 500 Ω) |
| Communication Protocols | Modbus RTU, Profibus DP |
| Operating Temperature | 5–40 °C |
| Power Supply | 220 VAC, 50 Hz |
| Compliance | DIN 38405-Part D11 (German Standard for Phosphorus Determination) |
| Brand | HACH |
|---|---|
| Origin | USA |
| Model | PCII Portable Colorimeter |
| Measurement Range | Free/Total Chlorine: 0.01–2 mg/L (LR) and 0.1–8 mg/L (HR) |
| Chlorine Dioxide | 0.05–5 mg/L |
| Detection Limit | 0.01 mg/L Cl₂ (LR mode) |
| Optical System | LED-based fixed-wavelength photometry (525 nm for chlorine, 430 nm for ClO₂) |
| Display | Backlit LCD, 2-line alphanumeric |
| Data Storage | Up to 50 measurement records with timestamp |
| Enclosure Rating | IP67 |
| Power | Two AAA batteries (approx. 2,000 measurements per set) |
| Compliance | Meets EPA Method 334.0 (chlorine), ASTM D1253, and ISO 7393-2 requirements for field chlorine analysis |
| Brand | HACH |
|---|---|
| Model | Pocket Pro / Pocket Pro+ |
| Measurement Parameters | pH, ORP, Conductivity, TDS, Salinity, Temperature |
| Power Source | AAA batteries (replaceable) |
| Display | Backlit LCD (Pocket Pro+), Non-backlit LCD (Pocket Pro) |
| Compliance | Designed for field-deployable, GLP-supportive routine water quality verification |
| Sensor Architecture | Replaceable, integrated electrochemical sensor cartridges |
| Calibration | On-device 1–3 point calibration with auto-diagnostic feedback |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Polymentron 8350SC |
| Pricing | Available Upon Request |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Polymentron 8362SC |
| Pricing | Upon Request |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Polymentron 8398SC |
| Pricing | Available Upon Request |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Models | 8310, 8311, 8312 |
| Pricing | Available Upon Request |
| Key | Brand: HACH |
|---|---|
| Model | 9123 |
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Pricing | Available upon Request |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer | HACH Company |
| Import Status | Imported |
| Model | 9125 |
| Pricing | Upon Request |
| Conductivity Ranges | 0.01–200 µS/cm (with 8310 electrode, k=0.01 cm⁻¹), 0.1–2 mS/cm (with 8311 electrode, k=0.1 cm⁻¹), 1–20 mS/cm (with 8312 electrode, k=1 cm⁻¹) |
| Accuracy | ±1% of reading (conductivity/resistivity), ±0.4 °C (temperature) |
| Temperature Range Display | −20 to 200 °C |
| Temperature Compensation | Automatic nonlinear compensation optimized for ultrapure water |
| Sensor Compatibility | Two-electrode contact-type (8310/8311/8312) and inductive (toroidal) probes |
| Diagnostic Capability | Built-in self-check for two-electrode sensors |
| Output Options | 4–20 mA analog output (isolated), RS-485, Profibus DP, Modbus RTU (JBUS), optional 4 relay outputs |
| Enclosure Rating | IP66/NEMA 4X |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 9184 HOCl |
| Pricing | Upon Request |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer | HACH Company |
| Product Type | Imported Instrument |
| Model | 9184 TFC/PH |
| Pricing | Upon Request |