Water Quality Analysis
Filter
Showing 1081–1110 of 3714 results
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | EZ3503, EZ3504, EZ3505 |
| Instrument Type | Online Chloride Analyzer |
| Measurement Range | EZ3503: 1–10 mg/L Cl⁻ |
| EZ3504 | 10–100 mg/L Cl⁻ |
| EZ3505 | 100–1,000 mg/L Cl⁻ |
| Detection Limit | ≤1 mg/L Cl⁻ |
| Response Time | 8 minutes |
| Accuracy | ≤2% F.S. (with certified standard solutions) |
| Operating Temperature | 10–30 °C |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | EZ4000/5000 Series Hardness and Alkalinity Analyzers |
| Measurement Methods | EDTA potentiometric titration (EZ5000) and colorimetric titration using Ca/Mg indicator at 610 nm or Calcon at 620 nm (EZ4000 hardness) |
| Measured Parameters | Total Hardness, Calcium Hardness, Total Alkalinity, Free Alkalinity |
| Range (EZ4000 Hardness) | 100–1000 mg/L as CaCO₃ (EZ4041/EZ4044) |
| Range (EZ4000 Alkalinity) | 100–5000 mg/L as CaCO₃ |
| Range (EZ5000) | Total Hardness: 25–1000 mg/L |
| Total Alkalinity | 40–1000 mg/L (EZ5011) |
| Total/Calcium Hardness & Total/Free Alkalinity | 25–1000 mg/L / 100–5000 mg/L (other models) |
| Detection Limit (EZ4043) | ≤ 0.05 mg/L as CaCO₃ (LED immersion probe) |
| other models | ≤ 10 mg/L |
| Cycle Time | EZ4000: 10–15 min |
| EZ5000 | 20–30 min (up to 40 min with total + calcium hardness) |
| Operating Temperature | 5–35 °C ±5 °C (avoid direct sunlight and rain) |
| Relative Humidity | 5–95 % RH (non-condensing) |
| Sample Temperature | 10–30 °C |
| Storage Temperature (instrument) | −20 to +55 °C |
| (electrodes) | −15 to +55 °C |
| Power Supply | 110–240 VAC, 4 A, 50/60 Hz |
| Max. Power Consumption | 150 VA |
| Outputs | 4–20 mA (standard 1 channel, up to 8 optional), max. 500 Ω load |
| Pneumatic Supply | Dry, oil-free air per ISA-S7.0.01-1996 |
| Sample Flow Rate | 100–300 mL/min |
| Sample Requirements | Particulates ≤ 100 µm, < 0.1 g/L suspended solids |
| Certifications | CE, UL |
| Enclosure Rating | Analyzer cabinet IP55 |
| Dimensions (H×W×D) | 690 × 465 × 330 mm |
| Shipping Weight | 25 kg |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | EZ6000 Trace Metals Analyzer |
| Instrument Type | Online Analyzer |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Target Analytes | Arsenic (As³⁺/Total As), and configurable for additional heavy metals (e.g., Cd, Pb, Cu, Zn) |
| Analysis Cycle Time | ≤ 40 minutes (including digestion, if integrated) |
| Accuracy/Precision | ±5% of full scale |
| Resolution | ≤ 1 µg/L |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | EZ7300 Online ATP Analyzer |
| Measurement Principle | Bioluminescence Assay (Luciferin–Luciferase Reaction) |
| Compliance | ASTM D4012-81 |
| Channel Capacity | 8-Channel Simultaneous Flow Analysis |
| Sample Matrix | Process Water, Potable Water, Cooling Water, Power Plant Feedwater |
| Reagent Replacement | Tool-Free Cartridge-Based System |
| Automation Level | Fully Automated, Unattended Operation |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Filtrax |
| Sample Flow Rate | ~900 mL/h |
| Power Supply | 230 VAC ±10%, 50–60 Hz |
| Sample Temperature Range | 5–40 °C |
| Ambient Operating Temperature | −20 to +40 °C |
| Enclosure Rating | IP55 (Outdoor Installation) |
| Control Unit Dimensions | 430 × 530 × 220 mm |
| Filter Housing Dimensions | 92 × 500 × 340 mm |
| Weight | 41 kg |
| Heated Sample Intake Tubing Length | 5 m (standard) |
| Optional Sample Transport Tubing | 2 m (unheated), 10/20/30 m (heated) |
| Filtration Cut-off | 0.15 µm (ultrafiltration membrane) |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer | HACH Company (a Danaher subsidiary) |
| Product Type | Imported Industrial Online Analyzer |
| Model | FP360 sc |
| Pricing | Available upon Request |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer | HACH Company |
| Product Type | Imported |
| Model | GLI 3400 |
| Pricing | Available Upon Request |
| Electrode Constant Options | 0.05, 0.5, 1.0, 5.0, 10.0 |
| Conductivity Range | 0–200,000 µS/cm (dependent on electrode constant) |
| Resistivity Range | 0.001–20 MΩ·cm |
| Operating Temperature | –20 to 200 °C |
| Max Flow Rate | 3 m/s |
| Pressure Rating | 100 psig at 200 °C |
| Accuracy | ±0.01% of reading |
| Probe Weight | 0.45 kg |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | GLI 3700E |
| Price | Upon Request |
| Measurement Principle | Inductive (Toroidal) Conductivity Sensing |
| Range | 0–2,000,000 µS/cm |
| Wetted Materials | Polypropylene, PEEK, PFA Teflon®, or PVDF |
| Sample Temperature Range | −10 to 200 °C |
| Max Flow Rate | 3 m/s |
| Pressure Rating | Up to 200 psig at 150 °C |
| Accuracy | ±0.01% of reading across full range |
| Weight | 0.45 kg |
| Cable | Standard 20-ft integrated cable |
| Temperature Compensation | Automatic |
| Brand | HACH/GLI |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 5500 |
| Pricing | Available Upon Request |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer | HACH Company |
| Product Line | GLI |
| Controller Models | C53, C33, PRO-C3 |
| Measurement Parameters | Conductivity (0.0–2,000,000 µS/cm), Resistivity (0–19.99 MΩ·cm), TDS (0–9,999 ppm) |
| Temperature Range | −20.0 to +200.0 °C |
| Accuracy | Up to ±0.05% of full scale (PRO-C3), ±0.2% per 24 h (C53/C33) |
| Repeatability | Up to ±0.05% FS (PRO-C3), ±0.1% FS (C53/C33) |
| Sensor Inputs | 2 (C53, C33), 1 (PRO-C3) |
| Outputs | Dual 4–20 mA (C53, C33), Single 4–20 mA (PRO-C3) |
| Relays | 4 (C53), 2 (C33), N/A (PRO-C3) |
| Enclosure Rating | NEMA 4X / IP65 (all models) |
| Hazardous Area Certification | Class I, Division II, Groups A, B, C, D, T5 (PRO-C3 only) |
| Calibration Method | Dry-Cal™ (electrode constant & temperature coefficient pre-labeled on probe) |
| Compliance | CE, RoHS, FCC, UL 61010-1, ATEX/IECEx optional for PRO-C3 |
| Software Interface | Local menu-driven operation with password protection, diagnostic logging, and audit-ready configuration history |
| Brand | HACH |
|---|---|
| Model | GLI E53 / E33 / PRO-E3 |
| Measurement Principle | Inductive (Toroidal) Conductivity |
| Conductivity Range | 0.0–2,000,000 µS/cm |
| TDS Range | 0–9,999 ppm |
| Concentration Range | 0.0–200% w/w |
| Temperature Range | −20.0 to +200.0 °C |
| Accuracy (Conductivity) | ±0.2% FS (E53/E33), ±0.05% FS (PRO-E3) |
| Repeatability | ±0.1% FS (E53/E33), ±0.05% FS (PRO-E3) |
| Output | Dual 4–20 mA (E53/E33), Single 4–20 mA (PRO-E3) |
| Enclosure Rating | NEMA 4X / IP65 (E53/E33), NEMA 4X + Class I, Div 2, Groups A/B/C/D, T5 (PRO-E3) |
| Power Supply | 190–260 VAC (E53/E33), 16–30 VDC (PRO-E3) |
| Installation | Panel-mount, wall-mount, or pipe-mount |
| Compliance | CE, UL 61010-1, ATEX/IECEx (PRO-E3), FDA 21 CFR Part 11-ready software support |
| Brand | Hach |
|---|---|
| Model | GLI Series (D53/D33/PRO-D3) |
| Measurement Principle | Clark-type Polarographic Electrochemistry |
| DO Range | 0–99.99 ppm / mg/L |
| Saturation Range | 0–999.9 % |
| Temperature Range | 0.0–100.0 °C |
| Stability | ±0.05% of full scale |
| Repeatability | ±0.05% of full scale |
| Power Supply | 190–260 VAC (D53/D33), 16–30 VDC (PRO-D3) |
| Enclosure Rating | NEMA 4X (IP65) |
| Explosion Protection | PRO-D3 certified for Class I, Division II, Groups A, B, C, D, T5 |
| Calibration Methods | Air-saturation and sample comparison |
| Output Options | Up to two 4–20 mA analog outputs |
| Communication | RS-232 or HART® (D53/D33) |
| Display | Backlit LCD (D53/D33), LCD (PRO-D3) |
| Relay Outputs | 4 (D53), 2 (D33), None (PRO-D3) |
| Probe Support | Dual probe (D53/D33), Single probe (PRO-D3) |
| CE Certified | Yes |
| Temperature Compensation | Automatic |
| Diagnostic Functions | Built-in self-diagnostics |
| Mounting | Panel, wall, or pipe mount |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | UNIQ Fermentation DO Electrode |
| Pricing | Upon Request |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | GUARDIAN BLUE |
| Alarm Triggers | Signal threshold, High/Low parameter, Parameter freeze, Sensor offline |
| Power Supply | 115 VAC, 100 W |
| Operating Temperature | 5–40 °C |
| Storage Temperature | −20–65 °C |
| Humidity | ≤90% RH at 40 °C |
| Enclosure Rating | IP62 (industrial-grade, splash-resistant) |
| Communication | RS-485 MODBUS |
| Dimensions | 46 × 51 × 39 cm |
| Weight | 29 kg |
| Enclosure Material | 316 stainless steel |
| Mounting | Wall-mounted or pedestal-mounted |
| Display | 15-inch touchscreen |
| Certifications | EPA Environmental Technology Verification (ETV), UL 1010, U.S. Department of Homeland Security Safety Act Certified (Patent No. US 6,999,898), ASTM D5176-compliant data handling, FDA 21 CFR Part 11-ready audit trail support |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Raw Water Monitoring System |
| Pricing | Available Upon Request |
| Measurement Parameters | Dissolved Oxygen (LDO): 0–20.0 mg/L |
| Turbidity (SOLITAX sc) | 0–100 NTU |
| pH | 0–14 |
| Conductivity | 0–1000 mS/cm |
| Temperature | Standard ambient-to-water range |
| Ammonia-N (AMTAX sc) | 0.05–20.0 mg/L |
| Permanganate Index (CODMn) | 0–20 mg/L or 0–2000 mg/L |
| Chlorophyll-a | 0–500 µg/L |
| Phycocyanin (Blue-Green Algae) | 100–2,000,000 cells/mL |
| Total Phosphorus | 0.01–5.0 mg/L |
| Total Nitrogen | 0–2 mg/L or 0–200 mg/L |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | HC-7 |
| Pricing | Upon Request |
| Enclosure Material Options | PP, PVC, PVDF, PFA |
| Pressure Rating | Up to 0.15 MPa (pressurized models) |
| Max Flow Rate | ≤2 m/s |
| Reference Electrolyte Volume | ~500 mL (at 1.0 m sleeve length) |
| IP Rating | Rainproof (JIS C 0920 compliant) |
| Operating Temperature Range | Varies by electrode/sleeve combination (–5°C to 120°C) |
| Electrode Types | KCl-refillable pH and ORP electrodes (e.g., models 5600–5615, 2600–2615) |
| Junction Materials | FPM (Viton®), perfluoroelastomer |
| Sleeve Length Options | 0.5–4.0 m (in 0.5 m increments) |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Model | HC3800 sc pH Electrode |
| Pricing | Available upon Request |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Model | UNIQ Fermentation pH Electrode HC9420 |
| Pricing | Available Upon Request |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Model | HD3600 sc Conductivity Analyzer |
| Pricing | Available upon Request |
| Brand | Hach |
|---|---|
| Model | HIAC 8011 |
| Measurement Principle | Light Obscuration (LO) and Dual-Mode Sensing |
| Particle Size Range | 0.5–400 µm |
| Viscosity Range | 0–80 cP |
| Compliance Standards | ISO 4406, NAS 1638, ISO 11171, ASTM F312, USP <788> (contextual applicability) |
| Sample Volume Accuracy | Engineered via pressurized flow control in ABS-2 Automated Sampler |
| Repeatability | <5% RSD |
| Sampling Time | <60 seconds per run |
| Calibration Standards Supported | ISO 11171, ACFTD, MTD, PSL |
| Simultaneous Channel Counting | Up to 8 user-defined size thresholds |
| Operating Mode | Standalone (integrated touchscreen interface), no external PC required |
| Regulatory Readiness | Audit trail-capable data logging |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer | Hach Company |
| Instrument Type | Portable |
| Detection Principle | Colorimetric Spectrophotometry |
| Measurable Metals | As, Cr(Total), Cr(VI), Cu, Ni, Zn, Cd, Pb |
| Measurement Range (Typical) | As 0–4000 ppb |
| Reagent Catalog Numbers | 2822800, 2242500, 1271099, 2105869, 2651600, 2429300, TNT852, TNT850 |
| Kit Configurations | HM01 (DR2800 + battery + MP6P probe), HM02 (DR2800 + battery + H170NP pH/ORP probe + PHW77-SS stainless steel probe), HM03 (no DR2800, includes MP6P), HM04 (no DR2800, includes H170NP + PHW77-SS) |
| Compliance | Designed for field use in accordance with EPA Method 200.7, ISO 11969, and ASTM D3559/D5191 for metals analysis in water |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Online Analyzer |
| Detection Principle | Photometric Colorimetry |
| Measurable Metals | Cr(VI), Total Cr, Total Cu, Total Ni, Total Mn (Multi-Parameter Configurable) |
| Analysis Time | 25 min (Cr(VI)) |
| Accuracy/Precision | ±3% F.S. |
| Resolution | 0.001 mg/L |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | HQ1130 |
| Instrument Type | Portable |
| Measurement Principle | Polarographic Electrochemical Probe |
| Range | 0.1–20.0 mg/L (ppm), 1–200% Saturation |
| Accuracy | ±0.1 mg/L |
| Ingress Protection | IP67 |
| Data Storage | Up to 10,000 Records |
| Compliance | GLP-Compliant Logging, ASTM D888, ISO 5814, USP <643>, EPA Method 4500-O G |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | HQ30d with LDO Sensor |
| Measurement Range | 0–20 mg/L (ppm) and 0–200% saturation |
| Resolution | 0.01 mg/L |
| Sensor Type | Optical (Luminescence-based) |
| Cable Options | 1 m, 3 m, 5 m, 10 m, 15 m, 30 m (standard & rugged variants) |
| Compliance | Designed for ASTM D888, ISO 5814, and EPA Method 4500-O G |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer | Hach Company |
| Product Type | Imported Instrument |
| Model | HQd Series |
| Pricing | Available Upon Request |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HQd Series |
| Instrument Type | Laboratory & Field-Deployable Water Quality Analyzer |
| Measurable Parameters | pH, ORP, Conductivity, Dissolved Oxygen (LDO), BOD/CBOD (via LBOD electrode), Sodium, Ammonium, Ammonia, Fluoride, Nitrate, Chloride |
| Electrode Types | IntelliCAL™ Standard, Rugged, and Ultra Configurations |
| Compliance | ASTM D888, EPA Method 4500-O, EPA Method 415.3, ISO 5814, USP <643>, GLP/GMP Data Integrity Support (21 CFR Part 11–ready audit trail, user ID, sample ID, electrode serial logging) |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | HQd Series Benchtop |
| Instrument Type | Laboratory Water Quality Analyzer |
| Pricing | Available Upon Request |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | HT200S High-Temperature Digestion System |
| Pricing | Upon Request |