Water Quality Analysis
Filter
Showing 1231–1260 of 3714 results
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | ULTRATURB plus sc |
| Measurement Range | 0–1000 FNU (NTU) |
| Light Source | 860 nm Infrared LED |
| Detection Principle | ISO 7027 Compliant Ratio Method (90° + 180° Dual-Detector Scattering) |
| Self-Cleaning Option | Magnetic Coupling Brush System |
| Calibration Support | Dry-Check Validation Module |
| Compliance | ISO 7027, EN 27027, US EPA Method 180.1 (for turbidity), GLP/GMP-ready data logging capability |
| Brand | Hach |
|---|---|
| Model | UVAS eco sc |
| Measurement Principle | UV Absorption (Dual-Beam) |
| Compliance Standard | DIN 38404-3 (C3) |
| Parameter | SAC254 |
| Resolution | 0.5 m⁻¹ (or mg/L, ppm) |
| Accuracy | ±5% of reading or ±10 m⁻¹ |
| Optical Path Length | 1 mm |
| Range | 5–1500 m⁻¹ |
| Compensation Wavelength | 550 nm |
| Measurement Interval | ≥5 minutes |
| Cable Length | 10–100 m |
| Max Operating Pressure | 0.5 bar |
| Sample Temperature Range | +2 to +40 °C |
| Sample pH Range | 4.5–9.0 |
| Dimensions | ~75 × 323 mm |
| Weight | ~3.3 kg |
| Maintenance Interval | Every 6 months |
| User Maintenance Time | ~1 hour/month |
| Control Interface | Compatible with sc100 controller (PID, time-based, 2-point control) |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | HACH Company |
| Model | UVAS eco sc |
| Measurement Principle | Dual-beam UV absorption at 254 nm |
| Output Parameter | SAC254 (Specific UV Absorbance at 254 nm) |
| Optical Path Length | 1 mm |
| Range | 5–1500 m⁻¹ |
| Resolution | 0.5 m⁻¹ |
| Accuracy | ±5% of reading or ±10 m⁻¹, whichever is greater |
| Compensation Wavelength | 550 nm |
| Minimum Measurement Interval | 5 minutes |
| Cable Length | Standard 10 m (extendable to 100 m) |
| Analog Outputs | Two isolated 4–20 mA outputs |
| Probe Pressure Limit | 0.5 bar (via sc100 controller) |
| Sample Temperature Range | 2–40 °C |
| Sample pH Range | 4.5–9.0 |
| Dimensions (Probe) | ~75 × 323 mm |
| Weight (Probe) | ~3.3 kg |
| Maintenance Interval | Every 6 months |
| Routine User Maintenance | ~1 hour per month |
| Housing Material | Stainless steel (316L) |
| Cleaning Mechanism | Integrated automatic wiper blade |
| Reagent-Free Operation | Yes |
| Compliance | Designed for ISO 7027-compliant turbidity compensation |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer | Hach Company |
| Model | UVAS sc |
| Measurement Principle | UV Absorption at 254 nm (SAC₂₅₄) |
| Optical Path Length Options | 1 mm, 2 mm, 5 mm, 50 mm |
| Measuring Range (SAC₂₅₄) | 0.01–60 m⁻¹, 0.1–600 m⁻¹, 0–1500 m⁻¹, 2–3000 m⁻¹ |
| Derived Parameter Ranges | COD (0–20,000 mg/L), BOD (0–20,000 mg/L), TOC (0–10,000 mg/L) |
| Accuracy | ±3% of reading + 0.5 mg/L |
| Response Time | >1 min (adjustable) |
| Auto-Cleaning | Mechanical wiper (frequency programmable) |
| Output | Dual 4–20 mA (500 Ω load) |
| Communication | Modbus RTU or Profibus DP (optional) |
| Operating Temperature | 2–40 °C |
| Submersion Pressure Rating | 0.5 bar (max depth 2 m) |
| Power Supply | 230 VAC ±10%, 50 Hz, 15 VA or 24 VDC/AC ±25%, 800 mA |
| Sensor Dimensions | Ø70 × 333 mm |
| Sensor Weight | ~3.6 kg |
| Compliance | Designed for continuous operation in compliance with ISO 7027 (turbidity compensation), ASTM D5540 (UV absorbance correlation to organic carbon), and supports GLP/GMP data integrity requirements via sc200 controller audit trail |
| Brand | HACH |
|---|---|
| Model | UVASsc |
| Measurement Principle | UV Absorption at 254 nm |
| Optical Path Length Options | 1 mm, 2 mm, 5 mm, 50 mm |
| Measuring Range Options | 0.01–60 m⁻¹, 0.1–600 m⁻¹, 0–1500 m⁻¹, 2–3000 m⁻¹ |
| Measurement Cycle | 1 minute |
| Response Time | >1 min (adjustable) |
| Turbidity Compensation | Dual-beam optical system |
| Analog Outputs | Two isolated 0/4–20 mA outputs (max. load 500 Ω) |
| Communication Protocols | MODBUS RTU or PROFIBUS DP (configurable) |
| Enclosure Rating | IP65 |
| Operating Temperature | +2 °C to +40 °C |
| Probe Pressure Rating | Max. 0.5 bar (suitable for submersion up to 2 m depth) |
| Power Supply | 230 VAC ±10%, 50 Hz, 15 VA OR 24 VDC/AC ±25%, 800 mA |
| Probe Dimensions | Ø70 × 333 mm |
| Probe Weight | ~3.6 kg |
| Installation Options | Immersion or flow-through cell |
| Self-cleaning Mechanism | Mechanical wiper integrated |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | WDMP sc |
| Price | Upon Request |
| TOC Range | 0–25 mg/L (Enhanced) |
| pH Range | 0–14 |
| Conductivity Range | 0–2000 µS/cm |
| Turbidity Range | 0.01–100 NTU |
| Free/Total Chlorine Range | 0–5 mg/L |
| Pressure Range | 0–150 PSI |
| Temperature Range (Ambient) | −20–200 °C |
| Controller | sc1000 |
| Sensor Interface | Digital, RS485 |
| Max Sensor-to-Controller Distance | 1000 m |
| Enclosure Rating | NEMA 4X (Optional) |
| Mounting | Wall or Pole Mount |
| Sample Inlet | 1/2" OD tubing or 3/8" NPT |
| Sample Outlet | 3/4" NPT or flexible hose |
| Sampler Interface | 1/4" NPT |
| Weight | 29.5 kg |
| Dimensions | 56 cm × 131 cm |
| Sample Temp. | 5–40 °C |
| Sample Pressure | 20–125 psi (pressure regulator optional, P/N 6846600 for >125 psi) |
| Sample Flow Rate | 400–600 mL/min |
| Power | 115/230 VAC, 50 Hz |
| Max Power Consumption | 90 VA (CL17 module), ≤30 VA (other modules) |
| Display | sc1000 controller with integrated LCD |
| Communication Protocol | MODBUS over RS485 |
| Event Trigger Capability | Yes (supports external analyzers, auto-samplers, TOC, ORP) |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | XAT-200 |
| Measurement Principle | TPTZ-based spectrophotometry at 595 nm |
| Measurement Range | 0–0.5 mg/L Fe |
| Accuracy | ±5% FS |
| Repeatability | ±5% FS |
| Cycle Time | 60–999 min (user-configurable) |
| Sample Temp | 10–40 °C |
| Sample pH | 5–9 |
| Suspended Solids (SS) | <20 mg/L |
| Particle Size | <20 µm |
| Dilution/Wash Water Pressure | 0.05–0.15 MPa |
| Wash Water Flow | 0.2–1 L/min |
| Wash Water Temp | 15–35 °C |
| Wash Water Conductivity | <0.1 mS/m |
| Carrier Gas Pressure | 0.4–0.7 MPa |
| Gas Consumption | 10 NL/min |
| Analog Output | DC 4–20 mA (1 channel, 600 Ω load) |
| Digital I/O | Relay outputs for alarm, fault, and power-loss signals (DC 24 V / 1 A or AC 125 V / 0.3 A) |
| Data Storage | Internal CF card with auto-backup |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Power Consumption | ~800 VA |
| Weight | ~120 kg |
| Operating Environment | 10–40 °C, ≤80% RH (non-condensing), indoor installation only |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Online Analyzer |
| Detection Principle | Monochromatic Wavelength-Dispersive X-Ray Fluorescence (MWDXRF) |
| Target Elements | Pb, As |
| Measurement Time | Automatically selected between 10–50 minutes (10 min for high concentration |
| Detection Limits | Pb: 0.005 mg/L |
| As | 0.001 mg/L |
| Analytical Range | Pb: 0.15–10 mg/L |
| As | 0.1–5 mg/L |
| Sample Flow Rate | 50–80 mL/min |
| Sample Pressure | 5–50 psi |
| Power Supply | 230 VAC ±10%, 50–60 Hz |
| Power Consumption | 400 VA |
| X-ray Tube | 50 kV / 1 mA, air-cooled, 50 W |
| Repeatability | Pb: 1.5% at 1 ppm |
| As | 1.8% at 0.5 ppm |
| Enclosure Rating | IP53 |
| Communication | RS-485 (Modbus RTU) |
| Operating Temperature | 10–40 °C |
| Relative Humidity | 30–85 % RH |
| Dimensions (H×W×D) | 1040 × 600 × 437.16 mm |
| Relay Outputs | 2 channels, 220 V, 3 A |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory DO Analyzer |
| Model | Z LLIG S-14 |
| Measurement Principle | Polarographic (Clark-type with mechanical self-cleaning) |
| Range | 0–15 mg/L (Fe anode) / 0–25 mg/L (Zn anode) |
| Resolution | 0.05 mg/L |
| Standard Deviation | < 0.1 mg/L |
| Operating Temperature | 0–45 °C |
| Ambient Temperature | −20–40 °C |
| Max Pressure | 3 bar |
| pH Range | 6–9 |
| Minimum Conductivity | 200 µS/cm |
| Sensor Lifetime | 15–20 years |
| Electrode Lifetime | 3–5 years |
| Abrasive Wheel Replacement Interval | 8–18 months |
| Power Supply | 24 VDC ±15%, 200 mA |
| Output Signal | Digital (RS-485 or HART-compatible, depending on transmitter configuration) |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HGCF-100 for Ammonia Nitrogen |
| Price Range | USD 28,000 – 35,000 |
| Instrument Type | Laboratory Benchtop |
| Measurement Principle | Air-Segmented Continuous Flow Analysis (CFA) with Distillation and Colorimetric Detection |
| Measurement Range | 0.01–5 mg/L NH₃–N |
| Accuracy | ±1% of reading |
| Detection Limit | ≤0.005 mg/L NH₃–N |
| Sample Throughput | 30 samples/hour |
| Batch Capacity | Unlimited (software-controlled queue) |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HGCF-100 |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | Total Cyanide, Free Cyanide, Volatile Phenols, Anionic Surfactants (LAS), Ammonia-Nitrogen (NH₃-N), Orthophosphate, Total Phosphorus, Total Nitrogen, Sulfides, Hexavalent Chromium (Cr⁶⁺), Nitrate, Nitrite, Permanganate Index (CODₘₙ), Urea |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | HGCF-100 Cyanide |
| Price Range | USD 21,000 – 42,000 (FOB Beijing) |
| Instrument Type | Benchtop Laboratory Analyzer |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGCF-100 (Volatile Phenol Configuration) |
| Instrument Type | Benchtop Laboratory Continuous Flow Analyzer |
| Compliance | GB, HJ, EPA, ISO Standard Methods |
| Sample Throughput | Batch-mode Automated Analysis |
| Detection Principle | Air-Segmented Continuous Flow with On-line Distillation and Spectrophotometric Detection |
| Optical Detection | Full-spectrum CCD or Dual-beam Silicon Photodiode Detector |
| Reaction Coil | 2 mm ID Quartz Mixing Coil |
| On-line Pretreatment | Integrated Steam Distillation, Heating, Mixing, Dilution, and Auto-Cleaning |
| Automation Level | Fully Automated Including Auto-Sampling, Reagent Dispensing, Reaction Control, Data Acquisition, and System Flush |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGCF-200 / HGCF-210 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Parameters | Total Cyanide, Free Cyanide, Volatile Phenol, Anionic Detergents, Ammonia Nitrogen (NH₃-N), Orthophosphate, Total Phosphorus, Total Nitrogen, Sulfide, Hexavalent Chromium (Cr⁶⁺), Nitrate, Nitrite, Permanganate Index (CODₘₙ), Urea |
| Compliance Standards | HJ 665–2013, HJ 670–2013, HJ 667–2013, CJT 141–2018, SL/T 788–2019, NY/T 1121.7–2014, NY/T 1228–2015, ISO 14403:2012, ISO 14402:1999, ISO 23913:2016, ISO 15681-2:2003 |
| Optical Detection | Dual-beam silicon photodetector or full-spectrum CCD detector |
| Flow Cell Pathlength Options | 10 mm to 200 mm |
| Reaction Coil | 2 mm i.d. quartz mixing coil |
| Sample Introduction | Automated sampler with carbon fiber or borosilicate glass probe, auto-cleaning and wash solution auto-replacement |
| Online Pretreatment | Integrated heating, digestion, distillation, dialysis, extraction, degassing, dilution, and mixing modules |
| Light Source | Low-power LED with short stabilization time and >10,000 h lifetime |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGCF-200 Ammonia Nitrogen |
| Measurement Principle | Colorimetric Flow Analysis (Salicylate Method) |
| Measurement Range | 0.01–5 mg/L NH₃–N |
| Detection Limit | ≤0.005 mg/L NH₃–N |
| Accuracy | ±1% of reading |
| Sample Throughput | 30 samples/hour |
| Batch Capacity | Unlimited |
| Optical Cell Material | Fused quartz |
| Light Source | Low-power LED |
| Detector | Full-spectrum CCD with built-in monochromator |
| Online Dilution Ratio | 1–5000× |
| Reaction Tubing ID | ≥2 mm |
| Compliance | HJ 665-2013, HJ 670-2013, HJ 667-2013, ISO 14403:2012, ISO 14402:1999, ISO 23913:2016, ISO 15681-2:2003 |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Instrument Type | Laboratory Benchtop CFA |
| Application | Total and Free Cyanide Determination in Water and Environmental Matrices |
| Compliance | ASTM D7511, ISO 14403:2012, HJ 484–2009, EPA Method 335.4 |
| Detection Principle | Segmented Flow Analysis (SFA) with Air Segmentation, On-line Distillation & UV Digestion |
| Optical System | LED-based Photometer with Quartz Flow Cell and Full-spectrum CCD Detector |
| Sample Throughput | Up to 60 samples/hour |
| Detection Limit | ≤0.2 µg/L CN⁻ (as applicable per ISO 14403) |
| Linear Dynamic Range | 0–1000 µg/L (adjustable via on-line dilution 1:1 to 1:5000) |
| Reagent Management | Integrated Smart Reagent Rack with Level Sensing & Leak Detection |
| Automation | Fully Automated Sample Introduction, Pre-treatment, Reaction, Separation, Detection & Data Reporting |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGCF-200 Volatile Phenol |
| Instrument Type | Laboratory-Based Volatile Phenol Analyzer |
| Compliance | ASTM D3164, ISO 14402:1999, ISO 23913:2016, ISO 15681-2:2003, HJ 665–670/667–2013, CJT 141–2018, SL/T 788–2019, NY/T 1121.7–2014, NY/T 1228–2015 |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MJ33 |
| Pricing | Upon Request |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Model | BHP9510 |
| Type | Portable ATP Analyzer |
| Detection Principle | Firefly Luciferase–Based Bioluminescence Assay |
| Biological Agent | *Photobacterium phosphoreum* or *Aliivibrio fischeri* (freeze-dried luminescent bacteria, optionally firefly luciferase reagent system) |
| Spectral Detection Range | 320–1000 nm |
| Background Count Rate | 0 cps |
| Measurement Range | 0–65535 RLU (Relative Light Units) |
| Detection Time | 5–300 s (user-adjustable) |
| Sensitivity | ≤1 × 10⁻¹⁵ mol ATP |
| Data Storage | ≥1000 test records + 100 configurable upper/lower alarm thresholds |
| Display & Output | RLU only (no concentration conversion built-in |
| Power Supply | Two AA alkaline or rechargeable batteries |
| Battery Life | ≥8 h continuous operation |
| Weight | 258 g (including batteries) |
| Dimensions | 202 × 78 × 30 mm |
| Interface | USB 2.0 (for data export and firmware update) |
| Operating Environment | 5–40 °C, 10–90% RH (non-condensing) |
| Sample Interface | Integrated sterile swab with pre-moistened buffer (single-use, CE-marked for hygiene applications) |
| Compliance | Designed to support ISO 22000, HACCP, and FDA Food Code Chapter 4 verification protocols |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Model | BHP9511 |
| Detection Principle | Bioluminescent Bacteria Assay |
| Sample Capacity | 18 positions |
| Detector | Photomultiplier Tube (PMT) |
| Spectral Response Range | 300–650 nm |
| Operating Temperature | 5–40 °C |
| Display | Integrated LCD Touchscreen |
| Data Output | Built-in thermal printer, USB data export, PC connectivity |
| Onboard Data Storage | Yes |
| Software Interface | Windows-compatible analysis software with statistical tools |
| Compliance Context | Designed for GLP-compliant workflows |
| Brand | Hamamatsu Photonics / BHP |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | BHP9514 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Biological Indicator | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) bioluminescent bacteria |
| Sample Capacity | 18 positions |
| Minimum Assay Time | 5 min |
| Detector | Photomultiplier Tube (PMT) |
| Spectral Response Range | 300–650 nm |
| Display | Integrated LCD touchscreen interface |
| Data Output | Built-in thermal printer |
| Connectivity | USB and RS-232 for PC integration |
| Environmental Operating Range | 5–40 °C, 10–90% RH (non-condensing) |
| Compliance | Designed to support ISO 11348-3 and ASTM D5660-22 protocols |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Model | BHP9515 |
| Type | Portable Toxicity Analyzer |
| Biological Indicator | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) bioluminescent bacteria |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 10–90% RH (at 25 °C) |
| Minimum Assay Time | 5 min |
| Continuous Operation | ≥8 h on battery |
| Data Storage Capacity | 1,000 measurements per mode (ISO / Basic / RLU) |
| Detection Wavelength Range | 320–1000 nm |
| Luminescence Measurement Range | 0–65,535 RLU (Relative Light Units) |
| Instrument Weight | 258 g (including batteries) |
| Dimensions | 202 × 78 × 30 mm |
| Power Supply | 3 V DC (AA alkaline battery pack) |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Model | BHP9515 |
| Type | Portable bioluminescence-based toxicity analyzer |
| Biological indicator | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) |
| Detection principle | Inhibition of bacterial bioluminescence |
| Fastest assay time | 5 min |
| Continuous operation | ≥8 h on battery |
| Data storage | 1000 measurements per mode (3 modes total) |
| Spectral response range | 320–1000 nm |
| Measurement range | 0–65535 RLU (Relative Light Units) |
| Instrument weight | ~258 g (including batteries) |
| Dimensions | 202 × 78 × 30 mm |
| Power supply | 3 V DC (AA alkaline batteries) |
| Operating temperature | 5–40 °C |
| Operating humidity | 10–90% RH (at 25 °C) |
| Compliance | Designed for field-deployable GLP-aligned environmental screening |
| Software interface | USB data export, optional PC software for trend analysis and report generation |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | HBD-SC30 |
| Price | Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | H-PTN |
| Price | Upon Request |
| Handle | Stainless steel telescopic, max length 2.5 m |
| Ring diameter | 30 cm, stainless steel |
| Net body | Nylon, 60 cm length |
| Bottom tube | Aluminum alloy with brass valve |
| Mesh aperture options | 0.064 mm, 0.112 mm, 1 mm |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI83099 |
| Instrument Type | Portable Photometer |
| Measurement Principle | Colorimetric Absorption (Dichromatic LED-Based Optical System) |
| Wavelengths | 420 nm, 525 nm, 575 nm, 610 nm |
| COD Range Options | 0–150 mg/L (LR), 0–1500 mg/L (MR), 0–15000 mg/L (HR) |
| COD Accuracy | ±10% of reading |
| Repeatability | ±5% |
| LOD (COD-LR) | 0.1 mg/L |
| Measurement Time | 20 min per sample (digestion not included) |
| Batch Capacity | 15 or 30 samples simultaneously (with optional digestion block) |
| Compliance | EPA Method 410.4, ISO 15705 |
| Data Storage | 200 measurement records with timestamp, sample ID, and operator ID |
| Power | Rechargeable 9V battery or AC adapter (230 VAC / 12 VDC) |
| Dimensions | 235 × 200 × 110 mm |
| Weight | 640 g |
| Certifications | CE, RoHS |
| Environmental Rating | IP67-rated housing (dust-tight, immersion-resistant up to 1 m for 30 min) |
| GLP Features | Real-time clock, audit trail, auto-zero calibration, background-lit LCD |
| Brand | Hanna |
|---|---|
| Origin | Italy |
| Model | HI9147 |
| Instrument Type | Portable |
| Measurement Principle | Galvanic Cell Electrochemical Probe |
| DO Range | 0.0 to 50.0 mg/L (ppm) |
| Saturation | 0 to 600% |
| Accuracy | ±1% of reading |
| Resolution | 0.1 mg/L (DO), 1% (saturation) |
| Temperature Range | 0.0 to 50.0 °C |
| Temp. Accuracy | ±0.2 °C |
| Altitude Compensation | 0 to 4000 m |
| Salinity Compensation | 0 to 51 g/L |
| Electrode | HI76409 galvanic DO probe with integrated temperature sensor, 4/10/15 m cable options |
| Power | 3 × 1.5 V AAA batteries |
| IP Rating | IP67 |
| Dimensions | 185 × 72 × 36 mm |
| Weight | 450 g |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HI9143 |
| Pricing | Available Upon Request |
