Wavelength Dispersive X-Ray Fluorescence Spectrometer
Filter
Showing 31–60 of 65 results
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Supermini200 |
| Instrument Type | Scanning WDXRF |
| X-ray Tube Power | 200 W |
| Elemental Range | O (8) to U (92) |
| Cooling | Air-cooled (no liquid nitrogen or external water cooling required) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Supermini200 S |
| Instrument Type | Benchtop WDXRF Spectrometer |
| Excitation | Monochromatic Pd-target X-ray Tube (50 kV, 4 mA, 200 W) |
| Analyte Elements | Total S (ASTM D7039), Total Cl (ASTM D5059), Total Si (SH/T 0993), Total Pb (ASTM D5059) |
| Detection Limits | S: 0.1 ppm, Cl: 0.1 ppm, Si: 0.5 ppm, Pb: 0.2 ppm |
| Quantification Range | 0–99.99 wt% |
| Detector Linear Range | kcps |
| Beryllium Window Thickness | µm |
| Sample Forms | Liquids (gasoline, diesel, naphtha, jet fuel, crude oil, residuum, aqueous samples), Solids (catalysts, polypropylene), Powders |
| Compliance Standards | ASTM D7039, ASTM D5059, SH/T 0842, SH/T 0977, SH/T 0993 |
| Automation | Integrated 12-position autosampler |
| Optical System | Multi-crystal automatic switching optics with monochromatic excitation |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Supermini200 |
| Instrument Type | Benchtop WDXRF Spectrometer |
| Excitation Source | Pd-anode X-ray tube (50 kV / 4 mA, 200 W) |
| Analyzed Elements | Total S, Total Cl, Total Si, Total Pb |
| Detection Limits | S: 0.15 ppm, Cl: 0.1 ppm, Si: 0.5 ppm, Pb: 0.2 ppm |
| Quantification Range | 0–99.99% |
| Optical Configuration | Single-wavelength excitation with automated multi-crystal changer (RX4, RX9, and others) |
| Sample Handling | 12-position automatic sample changer |
| Compliance Standards | GB/T 111140 (S), SH/T 6083 (Cl & Si), ASTM D5059 (Pb) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Instrument Type | Benchtop |
| X-ray Tube Power | 200 W |
| Elemental Range | Na (11) to U (92) |
| Detector | Flow Proportional Counter (F-PC) and Scintillation Counter |
| Sample Handling | 12-position Automatic Sampler |
| Operating Atmosphere | Air, He, or Vacuum |
| Dimensions | 580(W) × 670(H) × 680(D) mm |
| Power Supply | 200–240 V, 10 A |
| Grounding Resistance | <30 Ω |
| Ambient Temperature | 10–40 °C |
| Relative Humidity | <80% RH |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Instrument Type | Benchtop |
| X-ray Tube Power | 200 W |
| Target Material | Pd |
| Detector Types | Flow-proportional Counter (F-PC) and Scintillation Counter (SC) |
| Analytical Elements | Na (11) to U (92) |
| Configuration | Multi-channel WDXRF |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | WDA-3650 |
| Instrument Type | Floor-standing |
| X-ray Tube Power | 4 kW |
| Elemental Range | Be (4) to U (92) |
| Detector Configuration | High-sensitivity AD-Boron channel for boron analysis |
| Instrument Architecture | Hybrid scanning + fixed-channel (multi-channel) WD-XRF |
| Sample Compatibility | Up to 200 mm wafers and magnetic/optical disks |
| Automation | Fully automated daily calibration (AutoCal), C-to-C robotic handler compatible (optional), SECS/GEM interface support |
| Vacuum & Thermal Stability | Integrated vacuum stabilization and active cooling systems |
| Footprint | 1.12 m (W) × 1.45 m (H) × 0.89 m (D) |
| Mass | 600 kg |
| Power Supply | 3-phase 200 VAC 50/60 Hz, 30 A or single-phase 220–230 VAC 50/60 Hz, 40 A |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XGT-5700 |
| Price Range | USD 42,000–70,000 (FOB) |
| Instrument Type | Scanning Micro-XRF |
| Analytical Element Range | Na (Z=11) to U (Z=92) |
| Primary Beam Diameter Options | 3 mm (standard), 100 µm, 10 µm |
| Primary Beam Filtration | Auto-switching for 3 mm beam (4 filters) |
| Secondary Beam Filtration | Motorized ON/OFF filter for enhanced sensitivity in regulated heavy metal analysis (e.g., Pb, Cd, Hg, Cr, Br) |
| Detector | Liquid-nitrogen-cooled, high-purity Si(Li) detector (3 L Dewar capacity) |
| Maximum Sample Dimensions | 350 × 400 × 40 mm |
| Stage Scan Range | Standard 100 × 100 mm |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | ZSX Primus 400 |
| Instrument Type | Floor-standing |
| X-ray Tube Power | 4 kW |
| Elemental Range | Be (4) to U (92) |
| Maximum Sample Diameter | 400 mm |
| Maximum Sample Thickness | 50 mm |
| Maximum Sample Mass | 30 kg |
| Measurement Spot Size | 0.5–30 mm (5-step motorized selection) |
| Compliance | SEMI, CE |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | ZSX Primus II |
| Excitation Source | End-window Rh-target X-ray tube (3 kW or 4 kW) |
| High-voltage Generator | High-frequency inverter type |
| Max. Output | 60 kV / 150 mA (4 kW) |
| Stability | ±0.005% (against ±10% AC line fluctuation) |
| Cooling | Integrated water-cooling system |
| Sample Changer Capacity | Up to 48 positions |
| Sample Dimensions | Ø51 mm × 40 mm (H) |
| Analyzed Area | Up to Ø35 mm |
| Sample Rotation | 30 rpm |
| Primary Beam Filters | Al, Ti, Cu, Zr (4-position auto-switch) |
| Collimators | 6 automatic apertures (Ø35, 30, 20, 10, 1, 0.5 mm) |
| Divergence Slits | 3 types (standard, high-resolution, ultra-light-element option) |
| Receiving Slits | SC and F-PC compatible |
| Goniometer | Independent θ–2θ drive |
| Angular Range | SC: 5°–118°, F-PC: 13°–148° |
| Max. Scan Speed | 1400°/min (2θ) |
| Continuous Scan Rate | 0.1–240°/min |
| Crystal Changer | 10-position auto-exchange |
| Standard Crystals | LiF(200), Ge, PET, RX25 |
| Optional Crystals | LiF(220), RX4, RX9, RX35–RX80, RX61F, TAP |
| Vacuum System | Dual-chamber rapid evacuation (dual-pump configuration) |
| Detectors | SC scintillation counter (1000 kcps linearity) for heavy elements |
| Pulse Height Analyzer (PHA) | Auto-adjustment (PAS, Rigaku patent) |
| F-PC Anode Wire Cleaning | Automatic thermal cleaning (ACC, Rigaku patent) |
| Optional Accessories | He purge module (with baffle), temperature-controlled sample stage (36.5 °C), CCD-based micro-imaging (100 µm resolution, 0.5 mm micro-area analysis & mapping), r-θ sample stage (Rigaku patent) |
| Software | NEW SQX (qualitative ID, background subtraction, smoothing, peak deconvolution, calibration curve method per JIS, matrix correction, standardless quantification, EZ-scan templates, auto-aperture selection, precision testing, email reporting, multi-standard management) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ZSX Primus IIInext |
| Instrument Type | Floor-standing |
| Instrument Kind | Scanning-type |
| X-ray Tube Power | 4 kW |
| Elemental Range | Be (4) to U (92) |
| Scan Speed | 2400°/min |
| Detector Linear Count Rate | SC: 1800 kcps |
| FPC | 3000 kcps |
| Beryllium Window Thickness | 30 µm |
| Goniometer Angular Reproducibility | ±0.0001° |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ZSX Primus IV |
| Price Range | USD 210,000 – 280,000 (FOB Yokohama) |
| Instrument Type | Scanning WDXRF |
| X-ray Tube Power | 4 kW |
| Elemental Coverage | Beryllium (Be, Z=4) to Curium (Cm, Z=96) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | ZSX Primus IV |
| Instrument Type | Floor-standing |
| X-ray Tube Power | 4 kW |
| Elemental Range | Be to U |
| Scan Speed | 2400°/min |
| Detector Linear Range | SC 1800 kcps, FPC 3000 kcps |
| Beryllium Window Thickness | 30 µm |
| Goniometer Angular Reproducibility | ±0.0001° |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | ZSX Primus IVi |
| Instrument Type | Floor-standing |
| X-ray Tube Power | 4 kW |
| Elemental Range | Be (4) to U (92) |
| Scan Speed | 2400°/min |
| Detector Linear Count Rate | SC: 1800 kcps |
| FPC | 3000 kcps |
| Beryllium Window Thickness | 30 µm |
| Goniometer Angular Reproducibility | ±0.0001° |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | ZSX Primus |
| Instrument Type | Floor-standing |
| X-ray Tube Power | 4 kW |
| Elemental Range | Be–U |
| Scan Speed | 2400°/min |
| Beryllium Window Thickness | 30 µm |
| Goniometer Angular Reproducibility | ±0.0001° |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LAB CENTER XRF-1800 |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MXF-2400 |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic |
| Model | MXF-N3 Plus |
| Price Range | USD 210,000 – 280,000 |
| Instrument Type | Simultaneous Multi-Channel |
| X-ray Tube Power | 3 kW |
| Elemental Range | Na (11) to U (92) |
| Brand | Sigray |
|---|---|
| Origin | Shanghai, China |
| Model | AttoMap-310 |
| Spatial Resolution (with high-res optics) | 3–5 µm |
| Detection Sensitivity | sub-ppm (relative), femtogram-level (absolute) |
| Incident Angle Range | 3° to 90° (0.01° step) |
| X-ray Source | Patented microfocus source with up to 5 selectable anode targets (e.g., Si, Cr, Cu, Rh, Mo, W, Au, Ti, Ag) |
| Max Power / Voltage | 50 W / 20–45 kVp |
| X-ray Optics | Dual-parabolic grazing-incidence mirrors, ~80% transmission efficiency, 1:1 default magnification |
| Detector | Silicon Drift Detector (SDD), energy resolution <129 eV (Mn-Kα) |
| Vacuum Chamber | <10⁻⁴ Torr |
| Sample Stage Travel | 100 × 100 mm |
| Light Element Detection Limit | Down to boron (B), quantitative for C, N, O at <1% wt. |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | WDX200 |
| Pricing | Available Upon Request |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | WDX400 |
| Pricing | Upon Request |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | WDX4000 |
| Price Range | USD 210,000 – 280,000 |
| Instrument Type | Sequential Scanning |
| X-ray Tube Power | 4 kW |
| Elemental Coverage | Standard: C–U (Z = 6–92) |
| Enhanced | Be–U (Z = 4–92) |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTRO SCOUT |
| Type | Portable, Hybrid (Scanning + Multi-Channel) ED-XRF Spectrometer |
| Detector | Silicon Drift Detector (SDD) |
| X-ray Tube | Rh anode, max. 50 kV |
| Elemental Range | Na (11) to U (92) |
| Spot Size | 1 mm diameter |
| Dimensions (transport) | 270 × 306 × 306 mm |
| Dimensions (operational) | 350 × 306 × 306 mm |
| Weight | 12.0 kg (without battery), 12.75 kg (with battery) |
| Power Supply | 10–30 V DC (integrated Li-ion battery) |
| AC adapter | 90–264 V AC, 50–60 Hz |
| Interface | Integrated touchscreen PC, Bluetooth, Wi-Fi, LAN, USB |
| Software | SPECTRO XRF Analyzer Pro with iCAL (intelligent Calibration) |
| Compliance | Designed for field-deployable GLP-aligned workflows |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | XEPOS |
| Instrument Type | Floor-standing |
| X-ray Tube Power | 50 W |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Detection Limit Improvement | Up to 3× lower vs. prior-generation ED-XRF |
| Analytical Range | Sub-ppm to 100% w/w |
| Repeatability | < 0.1% RSD (at mid-range concentrations) |
| Energy Resolution | < 130 eV (Mn Kα) |
| Excitation Mode | Polarized, Single-Wavelength (Monochromatic) Secondary Target Excitation |
| Software Platform | TurboQuant II |
| Compliance Framework | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Yes |
| Origin Category | Imported |
| Model | ARL Perform’X |
| Instrument Type | Floor-standing |
| Instrument Class | Scanning-type |
| X-ray Tube Power Options | 1500 W / 2500 W / 4200 W |
| Elemental Range | Be to U (Atomic Number 4 to 92) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Niton XLt 797RWY |
| Instrument Type | Portable |
| X-ray Tube Power | 400 W |
| Detectable Elements | Boron (B, Z=5) to Uranium (U, Z=92) |
| Detector Linearity Range | kCPS |
| Beryllium Window Thickness | µm |
| Detector | Peltier-cooled Si-PIN |
| Energy Resolution | <250 eV (FWHM at Mn Kα, 2σ confidence) |
| Weight | 1.4 kg |
| Dimensions | 248 × 273 × 95 mm |
| Battery Life | 6–12 h |
| Operating Voltage | 40 kV / 50 µA max |
| Filter System | Dual-filter configuration (Filter 2 optimized for Cl and Cr in halogen-free screening) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ARL 9900 |
| Instrument Type | Floor-standing |
| X-ray Tube Power Options | 1.2 kW, 2.5 kW, 3.6 kW, 4.2 kW |
| Elemental Range | Be to U (with appropriate analyzing crystals) |
| Sample Introduction | 8-position, 12-position or 98-position autosampler |
| Weight | ~750 kg |
| Max. Power Consumption | 4.8 kVA |
| Configuration | Scanning-type WDXRF spectrometer with optional simultaneous XRD channel |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | ARL Optim’X |
| Instrument Type | Floor-standing |
| X-ray Tube Power | 50 W / 200 W (equivalent via UCCO™ technology) |
| Elemental Range | F to U (73 elements) |
| Analysis Mode | Simultaneous (fixed-channel) and Sequential (scanning) |
| Cooling | Air-cooled, no external water circulation required |
| Sample Handling | Standard 1-position manual loader |
| Software | Thermo Scientific OXSAS with OptiQuant™ quantitative package |
| Compliance | Designed to meet ASTM E1361, ISO 2936, ISO 8258, and GLP/GMP data integrity requirements (21 CFR Part 11-ready audit trail) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ARL PERFORM'X Sequential |
| Price Range | USD 135,000–205,000 (FOB) |
| Instrument Type | Sequential WDXRF |
| X-ray Tube Power | 1.5 kW (ARL PERFORM'X 1500W), 2.5 kW (ARL PERFORM'X 2500W), 4.2 kW (ARL PERFORM'X 4200W) |
| Elemental Range | F (Z=9) to U (Z=92), plus C (Z=6) |
| Detection Limit | Sub-ppm for most elements in optimized matrices |
| Angular Positioning Accuracy | ≤0.0005° (Moiré fringe encoder-based goniometer) |
| Sample Form | Solids (pressed pellets, fused beads), Liquids (sealed cells), Powders, Coatings |
| Automation | Integrated XYZ sample changer with up to 120-position capacity |
| Brand | XOS |
|---|---|
| Model | Clora 2XP |
| Instrument Type | Benchtop |
| Excitation Principle | Monochromatic WDXRF (Single-Wavelength XRF) |
| Target Element | Chlorine (Cl) |
| X-ray Tube Power | 75 W |
| Detection Limit | 0.07 ppm (at 600 s) |
| Quantification Range | 0.07 ppm – 2 wt% |
| Sample Volume | ≤10 mL |
| Sample Membrane | Ethylene Tetrafluoroethylene (ETFE) film |
| Measurement Time | Adjustable from 30 to 900 seconds |
| Calibration | Multi-curve storage with automatic high-sulfur/low-chlorine correction |
| Motion-Free Optics | Dual hyperbolic bent-crystal optics (monochromator + analyzer) |
| Compliance | ASTM D7536-16, ASTM D4929-19 (Method C), SH/T 0977-2019 |
| Brand | XOS |
|---|---|
| Model | Clora |
| Instrument Type | Benchtop WDXRF Analyzer |
| Excitation | Monochromatic X-ray Beam |
| Target Element | Chlorine (Cl) |
| X-ray Tube Power | 75 W |
| Detection Limit (LOD) | 0.13 ppm |
| Measuring Range | 0.13 ppm – 3000 ppm (standard), up to 4 wt% (optional) |
| Sample Volume | ≤10 mL |
| Measurement Time | 30–900 s (user-configurable) |
| Sample Form | Liquid hydrocarbons, aqueous solutions, solid powders (with AccuCell cup) |
| Compliance | ASTM D7536-16, ASTM D4929-19 (Method C), SH/T 0977-2019 |
| Optical System | Dual Hyperbolic Bent-Crystal Monochromators |
| Detector | High-resolution proportional counter or scintillation detector (configuration-dependent) |
| Calibration | Multi-curve storage, manual high-sulfur/low-chlorine correction |
| Optional Accessories | AccuFlow™ suspension compensation module, AccuCell™ sample cups, automated sample changer |