- All
- Favorite
- Popular
- Most rated
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WMD950 |
| Type | Benchtop Tissue Homogenizer |
| Output Power | 950 W |
| Display | TFT High-Brightness LCD |
| Control | Rotary Knob + Touch Interface |
| Speed Range | 1,000–17,000 rpm (10-step adjustment) |
| Timer | 1 s–60 min |
| Operating Modes | Continuous, Pulse, Momentary, Programmable |
| Safety Interlock | Lid-actuated motor cutoff |
| Noise Level | 76 dB(A) at 17,000 rpm |
| Operating Temperature | 10–40 °C |
| Voltage | 230 V AC, 50 Hz |
| Dimensions | Ø194 × 516 mm |
| Weight | 4.4 kg |
| Compliance | EN 60335-1:1988, EN 60335-2-64:1993, EN 55014:1993, EN 61000-3-2:1995, EN 61000-3-3:1995 |
| Protection Class | IP20 (Class I) |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | D-130C |
| Instrument Type | Handheld Homogenizer |
| Instrument Category | Adjustable High-Speed Disperser |
| Sample Volume Range | 0.2–50 mL (with Shaft 5E) / 3–250 mL (with Shaft 12E), aqueous medium |
| Output Power | 100 W |
| No-Load Speed Range | 0–25,000 rpm |
| Motor Type | Brushless DC Motor |
| Contact Material | 316L Stainless Steel |
| IP Rating | IP30 |
| Shaft Coupling | Quick-Release Mechanism |
| Safety Control | Dual-Button Activation |
| Cable Length | 2 m Spiral Extension Cord |
| Dimensions (Base) | 160 × 185 × 162 mm |
| Dimensions (Handheld Unit) | 44 × 58 × 226 mm |
| Order Code | W3050130 |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | D-600 |
| Instrument Type | Rotor-Stator Probe Homogenizer |
| Dimensions (W×D×H) | 95 × 163 × 236 mm (host unit only) |
| Processing Volume | 0.05–2,000 mL |
| No-Load Speed Range | 500–30,000 rpm |
| Power Rating | 500 W |
| Noise Level | 66 dB(A) at 25,000 rpm |
| Rotor Diameter Options | Ø3–Ø25 mm |
| Protection Class | IP20 |
| Operating Voltage | 220 V / 50 Hz |
| Ambient Temperature | 0–40 °C |
| Relative Humidity | ≤80 % RH |
| Construction Material | 316L stainless steel with electrophoretic coating |
| Bearing Material | PTFE (Teflon)-lined precision bearings |
| Sterilization Compatibility | Autoclavable (121 °C, 20 min, steam) |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | D-500D |
| Instrument Type | Probe-type Rotor-Stator Homogenizer |
| Dimensions (W×D×H) | 157 × 76 × 236 mm (host unit only) |
| Weight | 2.0 kg (host unit only) |
| Processing Volume | 0.05–2000 mL |
| Speed Range | 500–30,000 rpm (digital display & precise setting) |
| Power Output | 500 W |
| Noise Level | 66 dB(A) at 25,000 rpm |
| Rotor Diameter | 3–25 mm |
| IP Rating | IP20 |
| Operating Voltage | 220 V / 50 Hz |
| Ambient Temperature | 0–40 °C |
| Relative Humidity | ≤80 % RH |
| Construction Material | 316L stainless steel housing with electrogalvanized finish |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | HG400 Pro |
| Instrument Type | Stomacher-type |
| Dimensions (W×D×H) | 450×210×240 mm |
| Sample Volume Range | 50–400 mL |
| Beating Speed | 60–600 rpm |
| Adjustable Beating Distance | 0.5–16.5 mm |
| Timer Range | 1 s – 59 min 59 s |
| Motor Type | Brushless DC Motor |
| Viewing Window | Tempered Glass |
| Housing Material | Stainless Steel with Antimicrobial Coating |
| Compliance | ISO 13485, EN 61000-6-3, FDA 21 CFR Part 11 (Software Mode Optional) |
| Brand | WIGGENS |
|---|---|
| Origin | Switzerland |
| Model | WMA800 |
| Instrument Type | Bead Mill Homogenizer |
| Processing Volume | 2000–4000 mL |
| Motor Power | 800 W |
| Speed Range | 1000–17,000 rpm |
| Voltage | 230 V / 50 Hz or 100–120 V / 60 Hz |
| Noise Level | ≤79 dB(A) at 17,000 rpm |
| Operating Environment | 0–40 °C, ≤95% RH |
| Safety Compliance | EN 60335-1, EN 60335-2-64, EN 55014, EN 55104, EN 61000-3-2, EN 61000-3-3 |
| Protection Class | IPX0 (Class I) |
| Dimensions (H × Ø) | 245 mm × 190 mm |
| Weight | 5.3 kg |
| Order Code | W3053111 |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WMA 550 |
| Type | Probe-type homogenizer |
| Motor Power | 550 W |
| Speed Range | 600–14,000 rpm |
| Voltage | 230 V / 50 Hz or 100–120 V / 60 Hz |
| Dimensions (W×D×H) | 245 × 245 × 190 mm |
| Weight | 4.4 kg |
| Noise Level | ≤72 dB(A) at 14,000 rpm |
| Operating Environment | 0–40 °C, ≤95% RH |
| Safety Class | IP20, Protection Class I per EN 60335-1 |
| Compliance | EN 60335-1:1988, EN 60335-2-64:1993, EN 55014:1993, EN 55104:1995, EN 61000-3-2:1995, EN 61000-3-3:1995 |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | D-500 Pro |
| Output Power | 500 W |
| Sample Volume Range | 10–40,000 mL |
| Speed Range | 500–30,000 rpm |
| Rotor Diameter | Ø4–Ø23 mm |
| Max. Viscosity | 10,000 cP |
| Tip Speed | ≤34.9 m/s |
| Noise Level | 66 dB (2,500 rpm), 72 dB (30,000 rpm) |
| Motor Type | Brushless DC |
| Voltage | 220 V / 50 Hz |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤80 % RH |
| IP Rating | IP20 |
| Dimensions (W×D×H) | 76×157×236 mm |
| Net Weight | 1.8 kg |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | D-500Pro |
| Instrument Type | Probe-type Rotor-Stator Homogenizer |
| Dimensions (W×D×H) | 157 × 76 × 234 mm |
| Processing Volume | 0.1–250 mL |
| Speed Range | 500–30,000 rpm |
| Maximum Viscosity Handling | 10,000 cP |
| Tip Speed | ≤34.9 m/s |
| Motor | Brushless DC, 500 W |
| Noise Level | 66 dB (at 2,500 rpm), 72 dB (at 30,000 rpm) |
| Power Supply | 220 V / 50 Hz |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤80 % RH |
| IP Rating | IP20 |
| Weight | 1.8 kg (host only) |
| Rotor Diameter Options | Ø4–Ø23 mm |
| Safety Features | Overload protection, soft-start, safety switch |
| Wetted Materials | ASTM F899-grade 316L stainless steel |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | HG400VW |
| Instrument Type | Stomacher-style (Paddle-beating) |
| Sample Volume Range | 50–400 mL |
| Dimensions (W×D×H) | 450 × 210 × 240 mm |
| Beat Frequency | 20–600 cycles/min (equivalent to 10–300 rpm) |
| Timer Range | 1 s – 9 min 59 s |
| Viewing Window | Tempered Glass |
| Housing Material | Stainless Steel with Antimicrobial Coating |
| Motor Type | Brushless DC Motor |
| Power Supply | 110–220 V, 50–60 Hz |
| Compliance | ISO 11290-1, ISO 6887-1, ASTM D6978, USP <61>, EN ISO 13845 |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | D-500 |
| Instrument Type | Probe-type Rotor-Stator Homogenizer |
| Dimensions (W×D×H) | 70×70×255 mm (host unit only) |
| Weight | 1.3 kg (host unit only) |
| Processing Volume | 10–40,000 mL |
| Speed Range | 10,000–30,000 rpm |
| No-Load Speed | 10,000–30,000 rpm |
| Rotor Diameter | 4–23 mm |
| Maximum Viscosity | 10,000 cP |
| Tip Speed | 34.9 m/s |
| Power | 500 W |
| Voltage | 220 V / 50 Hz |
| Noise Level | 66 dB (at 2,500 rpm), 72 dB (at 30,000 rpm) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤80 % RH |
| IP Rating | IP20 |
| Material of Rotor/Stator | ASTM F138-certified 316L stainless steel |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | D-600 Pro |
| Instrument Type | Probe-type Rotor-Stator Homogenizer |
| Dimensions (W×D×H) | 95 × 163 × 236 mm (host unit only) |
| Processing Volume | 0.05–2,000 mL |
| Motor Power | 500 W |
| Speed Range | 500–30,000 rpm (no-load) |
| Speed Display & Control | TFT digital display with rotary encoder |
| Rotor Diameter Options | Ø3–Ø25 mm |
| Noise Level | 66 dB(A) at 25,000 rpm |
| Housing Material | Reinforced polymer with acoustic damping |
| Protection Rating | IP20 |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤80 % RH (non-condensing) |
| Voltage | 220 V / 50 Hz |
| Rotor-Stator Material | ASTM F138-certified 316L stainless steel with electropolished finish |
| Bearing Material | PTFE-composite, autoclavable (121 °C, 20 min, 1 bar steam) |
| Sterilization Compatibility | Fully compatible with ISO 17664-compliant cleaning and steam sterilization protocols |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WMD950 |
| Instrument Type | Probe-type rotating blade homogenizer |
| Display | TFT high-brightness LCD |
| Control | Rotary knob + touch interface |
| Speed Range | 1,000–17,000 rpm (10-step adjustment) |
| Timer | 1 s–60 min |
| Operating Modes | Continuous, Pulse, Momentary, Programmable |
| Safety Interlock | Lid-closed activation & automatic shutdown upon lid removal |
| Noise Level | 76 dB(A) at 17,000 rpm |
| Operating Temperature | 10–40 °C |
| Input Voltage | 230 V AC, 50 Hz |
| Power Rating | 950 W |
| Dimensions (Ø × H) | 194 × 516 mm |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | D-130C |
| Instrument Type | Rotor-Stator Probe Homogenizer |
| Dimensions (W×D×H) | 44 × 58 × 226 mm (handheld unit) |
| Processing Volume Range | 0.2–50 mL (for low-volume probes) / 3–250 mL (for high-volume probes, H₂O-equivalent) |
| No-Load Speed Range | 0–25,000 rpm |
| Motor Power | 100 W |
| Contact Material | ASTM F899 Grade 316L Stainless Steel |
| Ingress Protection Rating | IP30 |
| Shaft Options | Shaft 5E (0.2–50 mL, tip speed 4.7 m/s), Shaft 12E (3–250 mL, tip speed 14.1 m/s) |
| Sterilization Compatibility | Autoclavable (121°C, 20 min), dry heat, and chemical sterilants |
| Control | Analog rotary speed dial with mechanical scale |
| Safety | Dual-switch activation, overload protection, soft-start circuitry |
| Cable | 2 m helical coiled cable for ergonomic handheld operation |
Show next