- All
- Favorite
- Popular
- Most rated
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | RE10 |
| Capacity | 5 L |
| Rotation Speed | 5–300 rpm |
| Temperature Range | RT +5 to 180°C (oil bath), RT +5 to 85°C (water bath) |
| Temperature Control Accuracy | ±0.2°C |
| Condenser Surface Area | 1500 cm² |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Construction Material | SCHOTT DURAN 3.3 borosilicate glass |
| Heating Element | CrNi 4876 stainless steel immersion heater |
| Output Conductivity | ~1 µS/cm at 25 °C |
| Feed Water | Tap water |
| Cooling Water Inlet Temperature | >60 °C |
| Power Supply Options | 230 V / 14 A (4 L/h) |
| Base Dimensions | 300 × 300 mm |
| Safety Features | Automatic water level control, dry-run protection |
| Operating Cost | Negligible (no consumables or regeneration required) |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | DPM24E24 |
| Heating Method | Dry-block heating |
| Oscillation Speed Range | 150–800 rpm (1 rpm resolution, 10 rpm increment) |
| Pulse Frequency | 1–100 pulses/min |
| Duty Cycle | 1–99% |
| Timer Range | 1 sec–24 hr |
| Platform Temperature | Up to 80 °C |
| Base Block Temperature | Up to 105 °C |
| Orbital Displacement | 0.070° |
| Dimensions (W×D×H) | 48.9 × 58.4 × 50.8 cm |
| Platform Size | 25.4 × 30.5 cm |
| Weight | 36.3 kg |
| Compliance | Designed for EPA-compliant sample preparation workflows |
| Interface | USB port, optional PC software control |
| Safety | Over-temperature protection, integrated exhaust fan for solvent recovery cabinets |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WB-503C |
| Temperature Range | 35–65 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Rotational Speed Options | 1700 / 2500 / 5000 rpm |
| Heating Modes | Infrared Only / Infrared + Conductive / Conductive Only |
| Vacuum Source | PTFE-Coated Corrosion-Resistant Diaphragm Pump |
| Ultimate Vacuum | 100 mbar |
| Chamber Capacity | 0.5 mL × 50 |
| Timer Range | 0–99 h 59 min |
| Power Supply | 220 V, 50/60 Hz, 200 W |
| Dimensions (W×D×H) | 213 × 255 × 255 mm |
| Certifications | CE, RoHS 5 |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WB-503G |
| Heating Method | Dry-block heating |
| Temperature Range | Ambient +5 °C to 120 °C |
| Temperature Stability | ±0.1 °C |
| Sample Capacity | 20 positions |
| Tube Diameters Supported | 11 mm, 13 mm, 16 mm |
| Heating Power | 125 W |
| Dimensions (W×D×H) | 310 × 250 × 435 mm |
| Weight | 6 kg |
| Power Supply | 110/220 V, 50/60 Hz |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Type | Sub-boiling Distiller |
| Construction | Fully 304 Stainless Steel (chamber, immersion heater, condenser, outlet) |
| Output Rate | 3.5 L/hr or 7 L/hr |
| Conductivity | ≤2.5 µS/cm at 20°C |
| Resistivity | ≥0.4 MΩ·cm at 20°C |
| Safety Features | Low-level cutoff, pressure-relief valve, auto-shutdown on cooling water failure |
| Compliance | EN 61010-1:2002, EN 50082-1:1992, EN 50081-2:1994, Directive 2006/95/EC (LVD), 2004/108/EC (EMC), 2006/42/EC (Machinery) |
| Power Supply | 220 V / 50 Hz |
| Input Power | 3000 W (DA001) or 6000 W (DA002) |
| Dimensions (W×D×H) | 250×220×440 mm (DA001), 260×260×630 mm (DA002) |
| Weight | 12 kg (DA001), 14 kg (DA002) |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WB-504C |
| Temperature Range | 35–65°C |
| Temperature Control Accuracy | ±0.1°C |
| Maximum Rotational Speed | ≤1500 rpm |
| Vacuum Level | ≥2 mbar |
| Integrated Cold Trap | −20°C, 2 L capacity |
| Chamber Dimensions (W×D×H) | 600 × 630 × 1085 mm |
| Weight | 138 kg |
| Power Supply | 220 V, 50/60 Hz |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | FlexiVap |
| Heating Method | Dry-block heating |
| Temperature Range | Up to 100 °C |
| Temperature Stability | ±0.5 °C |
| Sample Positions | 24 or 48 |
| Heating Power | 150 W |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WB-502C |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | 40–80 °C (ambient) |
| Temperature Accuracy | ±0.1 °C |
| Sample Capacity | 1.5 mL × 132, 15 mL × 12, 50 mL × 8, 96-well plates × 2 |
| Maximum Rotational Speed | ≤1500 rpm |
| Vacuum System | PTFE-coated diaphragm pump (WIGGENS C410), ultimate vacuum ≥13 mbar |
| Cooling Trap | Integrated −20 °C cold trap (2 L capacity) |
| Heating Method | IR-heated glass lid + optional conductive heating |
| Control | PID temperature control, touch-key LED panel |
| Timer Range | 0–99 h 59 min |
| Dimensions (W×D×H) | 670 × 685 × 480 mm |
| Power Supply | 220 V, 50/60 Hz, 1200 W |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Heating Method | Dry-block heating |
| Temperature Range | Ambient to 100 °C |
| Temperature Uniformity | ±0.5 °C |
| Sample Tube Diameter Compatibility | 12 mm to 62 mm |
| Gas Flow Rate | 1–100 mL/min |
| Throughput Options | 2, 8, 12, 24, 28, 48, or 96 positions |
| Heating Power | 500 W |