- All
- Favorite
- Popular
- Most rated
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WCI-40G |
| Temperature Uniformity | ±0.3 °C (at 37 °C and RT 20 °C) |
| Chamber Volume | 40 L |
| External Dimensions | 420 × 460 × 570 mm |
| Internal Dimensions | 320 × 350 × 375 mm |
| Weight | 42 kg |
| Heating Power | 320 W |
| CO₂ Inlet Pressure Range | 0.3–0.5 bar |
| Standard Shelving | 2 shelves (up to 4 optional) |
| Temperature Display Accuracy | ±0.1 °C (at 37 °C) |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WCI-40Cu |
| Chamber Volume | 40 L |
| Temperature Range | Ambient +5°C to 60°C |
| Temperature Uniformity | ±0.3°C (at 37°C and 20°C ambient) |
| Temperature Display Resolution | 0.1°C |
| Temperature Display Accuracy | ±0.1°C (at 37°C) |
| CO₂ Range | 0–20% |
| CO₂ Accuracy | ±0.1% (at 5% CO₂, 37°C) |
| CO₂ Resolution | 0.1% |
| CO₂ Sensor Type | Dual-Beam Infrared |
| Heating Power | 320 W |
| Jacket Type | Air-Jacketed (Six-Side Gradient Heating) |
| Chamber Material | Electrolytic Copper with Oxidized Copper Surface |
| Standard Shelving | 2 shelves (up to 4 optional) |
| Control System | Microprocessor-Based PID Control |
| Gas Inlet Pressure | 0.3–0.5 bar |
| Display | LED |
| Sterilization Option | Dry-Heat Sterilizable Version Available |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WCI-260Z |
| Instrument Type | Air-jacketed CO₂ Incubator |
| Temperature Range | Ambient +5°C to 60°C |
| Temperature Uniformity | ±0.4°C (at 37°C / ambient 20°C) |
| Chamber Volume | 260 L |
| External Dimensions | 630 × 680 × 1125 mm |
| Heating Power | 610 W |
| CO₂ Range | 0–20% |
| CO₂ Accuracy | ±0.1% (at 5% CO₂, 37°C) |
| CO₂ Sensor | Dual-beam infrared |
| Temperature Display Resolution | 0.1°C |
| CO₂ Display Resolution | 0.1% |
| Control System | Microprocessor-based PID |
| Chamber Material | AISI 304 stainless steel |
| Standard Shelves | 3 (max. 8) |
| Internal Dimensions | 530 × 590 × 900 mm |
| Net Weight | 115 kg |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WCI-180R |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| Temperature Control Range & Accuracy | Ambient +5°C to 60°C (±0.1°C at 37°C) |
| Capacity | 180 L |
| Humidity | ≥70% RH (at 37°C) |
| CO₂ Control Accuracy | ±0.1% (setpoint 5% at 37°C) |
| CO₂ Sensor | Dual-Beam Infrared |
| Rotation Speed Range | 2–30 rpm (±1 rpm, 0.1 rpm resolution) |
| Heating System | Six-Side Direct Air-Jacket Heating with Triple Independent Temperature Sensors |
| Humidification | Bottom-Mounted Heated Water Pan with Forced-Air Circulation |
| Door | Heated Anti-Condensation Glass |
| Control System | Microprocessor-Based PID with LED Display |
| Compliance | Designed for GLP-compliant cell culture workflows |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CRC |
| Temperature Control Range & Accuracy | Ambient temperature |
| CO₂ Concentration Control Range & Accuracy | Ambient range % |
| Humidity Control Range & Accuracy | Ambient humidity %RH |
| Capacity | 100–8000 mL |
| Dimensions | 496 × 415 × 120 mm |
| Sterilization | Not suitable for full-unit autoclaving |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WCI-650 |
| Type | Air-jacketed CO₂ Incubator |
| Temperature Range | +5°C above ambient to 60°C |
| Temperature Uniformity | ±0.5°C (at 37°C / 20°C ambient) |
| Chamber Volume | 650 L |
| External Dimensions | 820 × 780 × 1740 mm |
| CO₂ Range | 0–20% |
| CO₂ Accuracy | ±0.3% (at 5% setpoint, 37°C) |
| CO₂ Sensor | Dual-beam infrared |
| Temperature Display Resolution | 0.1°C |
| CO₂ Display Resolution | 0.1% |
| Heating Power | 1100 W |
| Chamber Material | AISI 304 Stainless Steel |
| Standard Shelves | 3 (max. 15) |
| Internal Dimensions | 700 × 650 × 1430 mm |
| Weight | 230 kg |
| Inlet Pressure | 0.7–1.0 bar |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WCI-180Cu |
| Capacity | 180 L |
| Temperature Range | Ambient +5°C to 60°C |
| Temp. Uniformity | ±0.3°C (at 37°C / 20°C ambient) |
| Temp. Display Accuracy | ±0.1°C (at 37°C) |
| Temp. Resolution | 0.1°C |
| Control Algorithm | Digital PID |
| CO₂ Range | 0–20% |
| CO₂ Accuracy | ±0.1% (at 5% setpoint, 37°C) |
| CO₂ Resolution | 0.1% |
| CO₂ Sensor | Dual-beam infrared |
| Inlet Pressure Range | 0.3–0.5 bar |
| Heating Power | 320 W |
| Chamber Material | Electrolytic copper (oxidized surface) |
| Jacket Type | Air-jacketed (6-sided gradient heating) |
| Standard Shelving | 3 shelves (up to 8 optional) |
| Sterilization Mode | Dry-heat compatible (180°C) |
| Display | LED with independent dual-channel keypad |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WCI-180S |
| Temperature Control Range & Accuracy | +5–60 °C (±0.1 °C at 37 °C) |
| CO₂ Concentration Control Range & Accuracy | 0–20% (±0.1% at 5% setpoint, 37 °C) |
| Chamber Volume | 180 L |
| Humidity | ≥70% RH (at 37 °C, via water pan humidification) |
| Shaking Speed | 30–300 rpm (±1 rpm, 1 rpm step) |
| Display | LED touchscreen interface |
| Heating System | Six-sided air-jacketed heating with three independently calibrated Pt100 sensors |
| CO₂ Sensor | Dual-beam infrared (NDIR), temperature- and humidity-compensated |
| Chamber Material | AISI 304 stainless steel |
| Safety Features | Overtemperature cutoff, door-heating anti-condensation, PID-controlled microprocessor system |
| Compliance | Designed for GLP-compliant cell culture workflows |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WCI-260 |
| Instrument Type | Gas-Jacketed CO₂ Incubator |
| Temperature Range | Ambient +5°C to 60°C |
| Temperature Uniformity | ±0.4°C (at 37°C / ambient 20°C) |
| Chamber Volume | 260 L |
| External Dimensions | 630 × 680 × 1125 mm |
| Heating Power | 610 W |
| CO₂ Range | 0–20% |
| CO₂ Accuracy | ±0.1% (at 5% / 37°C) |
| CO₂ Resolution | 0.1% |
| CO₂ Sensor | Dual-Beam Infrared |
| Temperature Display Resolution | 0.1°C |
| Temperature Display Accuracy | ±0.1°C (at 37°C) |
| Control Method | Digital PID |
| Chamber Material | AISI 304 Stainless Steel |
| Standard Shelves | 3 (max 8) |
| Internal Dimensions (W×D×H) | 530 × 590 × 900 mm |
| Net Weight | 115 kg |
| Supply Pressure | 0.6–0.7 bar |
| Humidification | Passive Water Pan with Bottom Heater & Forced-Air Circulation |
| Door | Double-Layer Glass with Anti-Condensation Design |
| Filtration | Integrated HEPA Filter (≥99.99% @ 0.3 µm) |
| Optional Functions | Automatic Sterilization Cycle, O₂ Control Module, UV Germicidal Lamp, Refrigeration Unit |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WCI-850C |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Dual-Beam Infrared (IR) Sensor |
| Temperature Range | Ambient +5°C to 60°C |
| Temperature Uniformity | ±0.1°C (at 37°C) |
| CO₂ Concentration Range | 0–20% |
| CO₂ Control Accuracy | ±0.1% (at 5% setpoint, 37°C) |
| Chamber Volume | 850 L |
| External Dimensions (W×D×H) | 820 × 930 × 1840 mm |
| Internal Dimensions (W×D×H) | 700 × 800 × 1530 mm |
| Heating Power | 1400 W |
| Shelf Capacity | 5 stainless steel perforated shelves, 50 kg load per shelf |
| Sterilization | Dry-heat up to 120°C |
| Control System | Digital PID with LED touchscreen interface |
| Chamber Material | AISI 304 stainless steel |
| Door Configuration | Five independent tempered glass observation doors with integrated heating |
| Gas Inlet Pressure | 0.7–1.0 bar |
| Weight | 260 kg |
| Max. Cell Factory Load | 23 × 10-layer Nunc™ cell factories |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WCI-180H |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Dual-Wavelength Infrared (NDIR) Sensor |
| Temperature Control Range & Resolution | +5°C to 60°C, 0.1°C |
| Temperature Uniformity | ±0.3°C (@37°C and RT 20°C) |
| CO₂ Concentration Range & Accuracy | 0–20% vol, ±0.1% (@5%, 37°C) |
| Chamber Capacity | 180 L |
| Internal Dimensions (W×D×H) | 529 × 500 × 700 mm |
| Heating Power | 1400 W (Operating), 1500 W (Sterilization) |
| Power Supply | 220 V, 50/60 Hz |
| Weight | 144 kg |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WCI-15R |
| Capacity | 15.2 L |
| Temperature Range | 15–45 °C (at ambient 25 °C) |
| Temperature Uniformity | ±0.25 °C |
| CO₂ Control Range | 0–20 % |
| CO₂ Sensor | Dual-beam infrared |
| CO₂ Accuracy | ±0.1 % (at 5 %) |
| Gas Inlet Pressure | 0.7 bar (max. 1 bar) |
| Internal Dimensions (W×D×H) | 224 × 200 × 340 mm |
| External Dimensions (W×D×H) | 292 × 333 × 433 mm |
| Net Weight | 6.8 kg |
| Power Supply | 220 V, 50/60 Hz |
| Cooling/Heating | Peltier-based |
| Display | LED |
| Standard Accessories | 2 stainless steel shelves, stainless steel water pan, automotive DC power adapter |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WCI-1200 |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| Temperature Range | RT + 7°C to +60°C (at 25°C ambient) |
| Temperature Uniformity | ±0.5°C at 37°C (25°C ambient) |
| Humidity Control | Natural evaporation via heated water pan with forced-air distribution |
| Chamber Volume | 1204 L |
| External Dimensions (W×D×H) | 990 × 855 × 2123 mm |
| Internal Dimensions (W×D×H) | 868 × 720 × 1927 mm |
| Chamber Material | AISI 304 Stainless Steel |
| CO₂ Sensing | Dual-Beam Infrared Sensor (0–20% range, ±0.1% accuracy at 5% CO₂, 37°C) |
| Power Supply | 220 V, 50/60 Hz |
| Heating Power | 1600 W |
| Weight | 323 kg |
| Safety Features | Independent overtemperature cut-off, door-heating anti-condensation system, audible alarm for CO₂ deviation and temperature excursion |
| Compliance | Designed to support GLP-compliant cell culture workflows |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WCI-260H |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Dual-Wavelength Infrared (NDIR) Sensor |
| Temperature Range & Accuracy | Ambient +5°C to 60°C, ±0.1°C display resolution |
| Temperature Uniformity | ±0.3°C (@37°C and RT 20°C) |
| CO₂ Concentration Range & Accuracy | 0–20%, ±0.1% (at 5% setpoint, 37°C) |
| Chamber Capacity | 260 L |
| Internal Dimensions (W×D×H) | 640 × 500 × 800 mm |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WCI-40P |
| Temperature Control Range & Accuracy | +20 to +60 °C, ±0.1 °C display accuracy (at 37 °C), 0.1 °C resolution |
| Temperature Uniformity | ±0.3 °C (at 37 °C and ambient 20 °C) |
| CO₂ Concentration Range & Accuracy | 0–20%, ±0.1% (at 5% setpoint, 37 °C), 0.1% resolution |
| Chamber Volume | 40 L |
| External Dimensions (W×D×H) | 420 × 460 × 570 mm |
| Chamber Material | AISI 304 stainless steel |
| Heating Method | Air-jacketed (6-sided gradient heating) |
| Cooling Method | Peltier-based thermoelectric cooling |
| CO₂ Sensor Type | Dual-beam infrared (NDIR) |
| Control System | Microprocessor-based PID control with independent dual-channel keypad interface |
| Inlet Gas Pressure Range | 0.3–0.5 bar |
| Heating Power | 320 W |
| Standard Shelving | 2 shelves (up to 4 optional) |
| Net Weight | 42 kg |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WCI-120 |
| Temperature Range | RT +5 to 60 °C |
| Temperature Uniformity | ±0.3 °C (at 37 °C and 20 °C) |
| Chamber Volume | 120 L |
| External Dimensions | 580 × 560 × 765 mm |
| Heating Power | 320 W |
| CO₂ Range | 0–20% |
| CO₂ Accuracy | ±0.1% (at 5% CO₂, 37 °C) |
| CO₂ Sensor | Dual-beam infrared |
| Temperature Display Resolution | 0.1 °C |
| CO₂ Resolution | 0.1% |
| Chamber Material | SUS304 stainless steel |
| Control System | Microprocessor-based PID with independent dual-channel keypad |
| Air Jacket Type | Gas-jacketed with six-sided gradient heating |
| HEPA Filtration | Standard (optional high-temp HEPA) |
| Safety Features | Overtemperature cutoff, door-heating anti-condensation, audible alarm for CO₂/temperature deviation |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WCI-850 |
| Instrument Type | Air-jacketed CO₂ Incubator |
| Temperature Range | RT + 5°C to 60°C |
| Temperature Uniformity | ±0.5°C (at 37°C / ambient 20°C) |
| Chamber Volume | 850 L |
| External Dimensions | 820 × 930 × 1840 mm |
| Heating Power | 1400 W |
| CO₂ Range | 0–20% |
| CO₂ Accuracy | ±0.3% (at 5% CO₂, 37°C) |
| CO₂ Resolution | 0.1% |
| CO₂ Sensor | Dual-beam infrared |
| Temperature Display Resolution | 0.1°C |
| Temperature Display Accuracy | ±0.1°C (at 37°C) |
| Control System | Microprocessor-based PID |
| Chamber Material | AISI 304 stainless steel |
| Standard Shelving | 3 shelves (up to 15 optional) |
| Internal Dimensions | 700 × 800 × 1530 mm |
| Net Weight | 260 kg |
| Gas Inlet Pressure | 0.7–1.0 bar |
| Humidification | Heated water pan with forced-air distribution |
| Door | Heated anti-condensation glass door |
| Filtration | Integrated HEPA filter (≥99.99% @ 0.3 µm) |
| Optional Functions | O₂ control, UV sterilization, automatic decontamination cycle, refrigeration module |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Instrument Type | Air-jacketed CO₂ Incubator |
| Model | WCI-180 |
| Temperature Range | Ambient +5°C to 60°C |
| Temperature Uniformity | ±0.3°C (at 37°C / ambient 20°C) |
| Humidity Range | 20–80% RH |
| Chamber Volume | 180 L |
| External Dimensions | 560 × 620 × 945 mm |
| CO₂ Measurement Accuracy | ±0.1% (at 5% CO₂, 37°C) |
| CO₂ Sensor | Dual-beam infrared |
| Heating System | Six-sided air-jacketed heating with independent temperature sensors per zone |
| Chamber Material | AISI 304 stainless steel |
| Control System | Microprocessor-based PID control with LED display and dual-channel keypad |
| Sterilization Option | Dry-heat up to 125°C (optional) |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WCI-850CH |
| Temperature Range | Ambient +5 to 60 °C |
| Temp. Uniformity | ±1 °C at 37 °C |
| Humidity Range | 20–95% RH |
| CO₂ Range | 0–20% |
| CO₂ Accuracy | ±0.3% at 5% (37 °C) |
| Shaking Speed | 30–250 rpm |
| Speed Accuracy | ±1 rpm |
| Amplitude | 25 mm |
| Chamber Volume | 850 L |
| Chamber Dimensions (W×D×H) | 700 × 800 × 1530 mm |
| Shelf Dimensions | 520 × 520 mm |
| Power Supply | 220 V, 50/60 Hz |
| Weight | 393 kg |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WCI-40 |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| Temperature Range | Ambient +5 °C to 60 °C |
| Temperature Uniformity | ±0.3 °C (at 37 °C and 20 °C ambient) |
| Chamber Capacity | 40 L |
| External Dimensions | 420 × 460 × 570 mm |
| Internal Dimensions | 320 × 350 × 375 mm |
| Heating Power | 320 W |
| CO₂ Range | 0–20% |
| CO₂ Accuracy | ±0.1% (at 5% setpoint, 37 °C) |
| CO₂ Resolution | 0.1% |
| CO₂ Sensor | Dual-beam Infrared |
| Temperature Display Resolution | 0.1 °C |
| Temperature Display Accuracy | ±0.1 °C (at 37 °C) |
| Control System | Microprocessor-based PID |
| Chamber Material | AISI 304 Stainless Steel |
| Standard Shelving | 2 shelves (up to 4 optional) |
| Weight | 38 kg |
| Gas Inlet Pressure | 0.3–0.5 bar |
| Humidification | Heated Water Pan + Forced Convection |
| Door | Heated Anti-Condensation Glass |
| Filtration | Integrated HEPA Filter (≥99.97% @ 0.3 µm) |
| Optional Functions | UV Sterilization, O₂ Control, Automatic Decontamination Cycle, Refrigeration Module |
Show next