| Brand | Asylum Research |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Rodent Metabolic Monitoring System |
| Model | Mice Metabolic Cage |
| Dimensions (L×W×H) | 210 × 210 × 400 mm |
| Material | Polycarbonate (PC), autoclavable at 120°C |
| Urine Collection Capacity | 15 mL |
| Water Bottle Capacity | 880 mL |
| Grid Aperture | Ø1 mm |
| Compliance | ISO 9001-certified manufacturing process |
| Sterilization | Compatible with steam autoclaving (120°C, 20 min) |
| Brand | Bruker |
|---|---|
| Origin | France |
| Model | minispec LF50 / LF90 |
| Application | In vivo quantitative analysis of fat mass, lean body mass, and free fluid in live mice and rats |
| Measurement Principle | Pulsed low-field TD-NMR (1H) at 0.047 T (2 MHz) |
| Sample Orientation | Vertical or horizontal magnet configuration |
| Analysis Time | ≤ 120 s per animal |
| Animal Safety | Non-invasive, no ionizing radiation, no anesthesia required |
| Regulatory Context | Compliant with GLP-aligned data integrity requirements |
| Brand | Bruker |
|---|---|
| Origin | France |
| Model | minispec LF50/mq7.5 |
| Measurement Principle | Time-Domain Nuclear Magnetic Resonance (TD-NMR) |
| Operating Frequency | 7.5 MHz |
| Maximum Sample Mass | 85 g (mice) |
| Sample Tube Inner Diameter | 49 mm |
| System Footprint | ~70 cm × 110 cm |
| Regulatory Compliance | CE Marked, ISO 9001:2000 Certified |
| Software Platform | Microsoft Windows with Microsoft Access Database |
| Data Acquisition Interface | Graphical User Interface (GUI) optimized for lab operation |
| Calibration | User-performed with reference standards or biological samples |
| Animal State During Measurement | Conscious, non-anesthetized, unrestrained |
| Measurement Duration | Typically < 3 minutes per animal |
| Environmental Suitability | Designed for rodent housing facility integration (dust-resistant enclosure, shielded magnet housing) |
| Brand | Bruker |
|---|---|
| Origin | France |
| Model | minispec LF90II |
| Instrument Type | In Vivo Rodent (Mouse/Rat) Body Composition Analyzer |
| Operating Frequency | 6.2 MHz |
| Measurement Time | < 120 s per animal |
| Sample Handling | Non-invasive, anesthesia-free, restraint-only in dedicated cylindrical holder |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | Columbus Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | CLAMS |
| Pricing | Upon Request |
| Brand | DGM |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DGM |
| Pricing | Upon Request |
| Brand | DS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DXL-10 |
| Instrument Type | Research-grade rat metabolic housing system |
| Sample Capacity | 10 independent cages |
| Temperature Range | Ambient (room temperature operation) |
| Functional Configuration | Urine-feces separation |
| Material | AISI 304 stainless steel |
| Overall Dimensions | 1350 × 350 × 1500 mm |
| Individual Cage Dimensions | 250 × 200 × 200 mm |
| Cage Layout | 2 rows × 5 columns = 10 positions |
| Standard Accessories per Cage | 1 stainless steel drinking bottle, 1 feed hopper, 1 cage body, 1 collection tray |
| Additional Components | 1 modular stainless steel support frame with 4 locking casters |
| Brand | DS |
|---|---|
| Origin | Beijing, China |
| Model | DXL-X |
| Animal Type | Laboratory mouse (Mus musculus) |
| Capacity | 1–5 mice per cage |
| Temperature Range | Ambient (optional 4 °C refrigerated urine/feces collection module available) |
| Material | Polycarbonate (PC) or Polyphenylsulfone (PSU) |
| Cage Dimensions | Ø170 mm × 220 mm (cage body) |
| Overall | 210 mm × 210 mm × 400 mm |
| Urine Collection Vessel | 15 mL |
| Water Bottle Capacity | 880 mL |
| Filtration Mesh Aperture | 0.1 mm |
| Urine/Fecal Separation | Dual-compartment gravity-driven separation system |
| Compliance | Designed for GLP-aligned preclinical metabolic studies |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HT-Respiro 24/96/240 Series |
| Pricing | Available Upon Request |
| Oxygen Measurement Range | 0–50% O₂ or 0–22.5 mg/L |
| Detection Limit | 0.15% O₂ (15 ppb DO) |
| Accuracy | ±1% at 20.9% O₂ |
| Resolution | ±0.4% at 20.9% O₂ or ±5 µmol at 283.1 µmol |
| Response Time | <30 s |
| Drift | <1% air saturation per week (10-min sampling interval) |
| Channel Capacity | Up to 240 parallel channels (10 × 24-channel readers) |
| Sensor Technology | Fluorescence-based optical oxygen sensing (REDFLASH for 96-well format) |
| Sample Chamber Material | Borosilicate glass (24-well) or sterile polystyrene (96-well) |
| Chamber Volume | 80–1700 µL (24-well) |
| Dimensions (per 24-channel reader) | 163 × 89 × 22 mm |
| Weight (per reader) | 380 g |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | Insect High-Throughput |
| Detection Technology | Fluorescence-based Optical Oxygen Sensing |
| Channel Capacity | 96 simultaneous channels |
| Measurement Principle | Non-invasive, real-time O₂ consumption via phase-modulation fluorometry |
| Sample Types | Drosophila melanogaster, insect eggs/pupae, nematodes, soil microarthropods, and other small invertebrates |
| Operating Environment | Compatible with incubators (0–50 °C) and orbital shakers |
| Oxygen Measurement Range | 0–100% O₂ (gas phase) or 0–20 mg/L (aqueous phase) |
| Accuracy | ±0.1% O₂ @ 1% O₂ or ±0.05 mg/L @ 0.44 mg/L |
| Resolution | 0.01% O₂ or 0.005 mg/L |
| Response Time (t₉₀) | <30 s |
| Sampling Frequency | Up to 20 Hz per active channel |
| Integrated Sensors | Temperature (0–50 °C, ±0.5 °C, 0.012 °C resolution), Pressure (300–1100 mbar, ±6 mbar, 0.11 mbar resolution) |
| Power Supply | 5 V DC via USB |
| Dimensions (O₂ Host Unit) | 162 × 102 × 32 mm |
| Weight | 670 g |
| Chamber Material | Sterilizable transparent polystyrene |
| Software Compliance | Audit-trail enabled, timestamped raw data export (CSV, HDF5), supports GLP-aligned experimental metadata tagging |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | EcoTech Multi-Channel |
| Pricing | Upon Request |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Assembly | China |
| Model | SSI-ET Modular |
| Instrument Type | Research-grade rodent (mouse/rat) metabolic phenotyping system |
| Channel Configurations | 4-, 8-, 16-, or scalable multi-channel (up to 24+) |
| Gas Analytes | CO₂ (0–5% / 0–15%, dual-range NDIR), O₂ (0–100%, paramagnetic), H₂O (RH 0.2–100%, dew point −40 to +40°C) |
| Flow Control | Precision mass flow controllers (5–2000 mL/min), thermal-mass flow meters (±2% accuracy) |
| Data Acquisition | 12-channel DAQ (8 × 16-bit analog, 4 × dedicated thermistor inputs, 100 Hz sampling) |
| Software | EcoMetab v5.x with real-time RQ, VO₂, VCO₂, EE calculation |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments |
| Optional Modules | Implantable telemetry (E-mitter compatible), infrared thermography integration, activity monitoring (beam-break/PIR), environmental control (T/RH/O₂/CO₂ regulation), cage-integrated load cells & fat temperature sensors |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Model | Zebrafish High-Throughput |
| Detection Technology | Fluorescent Fiber-Optic Oxygen Sensing |
| Channel Capacity | 96 simultaneous channels |
| Oxygen Measurement Accuracy | ±0.1% O₂ @ 1% O₂ or ±0.05 mg/L @ 0.44 mg/L |
| Oxygen Resolution | 0.01% O₂ @ 1% O₂ or 0.005 mg/L @ 0.44 mg/L |
| Response Time | <30 s |
| Temperature Sensor Range | 0–50°C, Resolution: 0.012°C, Accuracy: ±0.5°C |
| Pressure Sensor Range | 300–1100 mbar, Resolution: 0.11 mbar, Accuracy: ±6 mbar |
| Max Sampling Frequency | 10–20 Hz per active channel |
| Power Supply | 5 VDC via USB |
| Dimensions (O₂ Host) | 162 × 102 × 32 mm |
| Weight (O₂ Host) | 670 g |
| Chamber Material | Sterilizable transparent polystyrene |
| In Situ Compatibility | Yes — designed for incubators and orbital shakers |
| Non-Invasive & Non-Destructive Operation | Yes |
| Brand | FMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Human Energy Metabolism Laboratory System |
| Price Range | USD 28,000 – 70,000 |
| Brand | FMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FMS |
| Pricing | Upon Request |
| Brand | FMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FMS Portable |
| Pricing | Available Upon Request |
| Dimensions | 35 × 30 × 15 cm |
| Weight | 4 kg |
| Power Supply | 12–15 VDC (AC adapter included) |
| Data Storage | Internal 32 GB SD card (user-replaceable) |
| Operating Temperature | 3–50 °C (non-condensing) |
| Gas Flow Range | 10–1500 mL/min |
| O₂ Sensor | Fuel cell, ~2-year service life, field-replaceable |
| CO₂ Sensor | Nondispersive dual-wavelength infrared (NDIR) |
| H₂O Sensor | Thin-film capacitive |
| O₂ Range | 0–100% |
| CO₂ Range | 0–5% |
| H₂O Range | 0–100% RH (no condensation) |
| Atmospheric Pressure Range | 30–110 kPa |
| Temperature Range | 0–100 °C |
| O₂ Accuracy | ±0.1% of reading (2–100%) |
| CO₂ Accuracy | ±1% of reading (0–5%) |
| H₂O Accuracy | ±1% RH (0–95%), ±2% RH (95–100%) |
| O₂ Resolution | 0.001% |
| CO₂ Resolution | 0.0001–0.01% |
| H₂O Resolution | 0.001% RH |
| O₂ Drift | <0.02% per hour (isothermal) |
| CO₂ Drift | <0.001% per hour (isothermal) |
| H₂O Drift | <0.01% RH per hour (isothermal) |
| Analog Inputs | 8-channel bipolar voltage |
| Temperature Inputs | 4-channel |
| Analog Outputs | O₂, CO₂, +2 user-defined |
| Digital Control Outputs | 8 × TTL logic |
| Digital Interface | USB-to-RS-232, SableBus high-speed interface |
| Sampling Interval | 0.1 s to 1 h (user-configurable) |
| Flow Control Accuracy | ±2% of reading |
| Flow Resolution | 0.1 mL/min (0–99.9), 1 mL/min (>100) |
| Environmental Compensation | Automatic temperature & barometric pressure compensation |
| Display | High-resolution capacitive touchscreen (real-time multi-parameter visualization) |
| Brand | Histrong |
|---|---|
| Model | HC-800 |
| Measurement Range | 0–190 mg/L and 0–12,000 mg/L |
| Sample Types | Urine, Serum, Saliva, Aqueous Solutions |
| Resolution | 0.01 mg/L |
| Analysis Time | <3 min per sample |
| Display | Dual-output (LCD + Thermal Printer) |
| Communication Interfaces | RS232, USB 2.0 |
| Power Supply | AC 220 V ±10%, 50 Hz, <60 W |
| Dimensions | 38.5 × 23.5 × 34.5 cm |
| Operating Environment | 10–35 °C, RH <85%, Low Magnetic Interference |
| Compliance | Designed for GLP-compliant laboratory workflows |
| Software Option | Optional LIMS-integrated data management module |
| Origin | USA |
|---|---|
| Category | Imported Instrument |
| Distribution Model | Authorized Distributor |
| Compliance | ASTM E2583, ISO 8573-1 (gas purity), ISO 9001-certified manufacturing processes |
| Software Validation | FDA 21 CFR Part 11–compliant audit trail and electronic signature support |
| Gas Analysis Accuracy | O₂ ±0.1% (2–100% range), CO₂ ±1% of reading, CH₄ ±1% of reading (optional), H₂O ±1% RH |
| Flow Control Range | 10–1650 L/min (multi-stage PID-regulated) |
| Data Acquisition | 12-channel synchronized sampling at 100 Hz, 16-bit ADC resolution |
| Thermal Imaging | 640 × 512 IR resolution, NETD ≤30 mK, calibrated to NIST-traceable blackbody standards |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | IR VIVO NIR-II Multispectral In Vivo Imaging System |
| Price Range | USD 13,500 – 27,000 |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Rat Metabolic Cage |
| Model | DXL-D |
| Dimensions (L×W×H) | 300 × 300 × 650 mm |
| Material | Medical-Grade Stainless Steel (AISI 304) |
| Water Bottle Capacity | 250 mL |
| Urine Collection | Funnel-Integrated Urine Ring with Dedicated Drain Tube |
| Feces Collection | Separated Conical Waste Chamber |
| Feed Delivery | Slide-In Drawer with Adjustable Hopper |
| Compliance | Designed to meet ISO 17025-aligned laboratory animal housing guidelines and AAALAC-recommended separation principles |
| Brand | Jiayuan |
|---|---|
| Origin | Beijing, China |
| Model | DXL-D |
| Construction Material | Polycarbonate (PC) |
| Dimensions (W×D×H) | 30 × 30 × 65 cm |
| Cage Capacity | Single adult rat (200–500 g) |
| Urine Collection | Funnel-cone separation system with anti-evaporation collection bottles |
| Feces Collection | Dedicated conical separator and dedicated fecal tube |
| Feed System | Dual-tier feed tray with drawer-style loading |
| Water Delivery | Calibrated drip tube with evaporation-resistant design |
| Cleanability | Fully disassemblable into 15 modular components |
| Optional Accessory | Refrigerated urine collection module (−4 °C to +8 °C) |
| Brand | Jiayuan |
|---|---|
| Model | DXL-XZL |
| Origin | Anhui, China |
| Construction | Stainless steel & PC housing with integrated thermoelectric cooling module |
| Cooling Range | 4–10 °C (adjustable) |
| Urine Collection Capacity | 15 mL per animal |
| Dimensions (Unit) | 210 × 210 × 400 mm |
| Power Supply | 24 V DC, ≤35 W |
| Compliance | CE-marked for laboratory use, compatible with GLP-compliant metabolic studies |
| Brand | Loligo Systems |
|---|---|
| Origin | Denmark |
| Model | Fish and Aquatic Invertebrate Respirometry System |
| Oxygen Measurement Principle | Intermittent-Flow Respirometry with Fluorescence-Based Optical DO Sensing |
| Channel Configurations | 1-, 4-, or 8-channel modular setups |
| Oxygen Sensor Range | 0–100% O₂ (0–45 ppm) |
| Detection Limit | 15 ppb |
| Temperature Compensation | Real-time Pt1000 (−50 to +180 °C, ±0.15 °C) |
| Salinity & Atmospheric Pressure Compensation | Yes |
| Data Output | Excel (.xlsx) and raw ASCII (.txt) |
| Software | AutoResp v5.x with SMR, Pcrit, and MO₂ rate calculation |
| Respiratory Chamber Materials | Acrylic or borosilicate glass |
| Chamber Diameter Options | 9–45 mm (small invertebrates) or 62–240 mm (teleosts, elasmobranchs, embryos) |
| Flow Control | Dual-submersible-pump architecture (circulation + exchange) |
| Communication | Bluetooth 4.0 LE for pump control and sensor signal acquisition |
| Environmental Modules | Optional temperature, dissolved oxygen, CO₂/pH regulation units |
| Brand | Loligo Systems |
|---|---|
| Origin | Denmark |
| Model | Loligo Zebrafish Respirometry System |
| Oxygen Measurement Principle | Fluorescence-based Optical Fiber Sensing |
| Oxygen Range | 0–100% (0–45 ppm) |
| Detection Limit | 15 ppb |
| Temp. Compensation | Real-time Pt1000 (−50 °C to +180 °C, ±0.15 °C) |
| Salinity & Pressure Compensation | Yes |
| Measurement Modes | Intermittent-flow respirometry |
| Channel Configurations | 4-, 8-, and up to 240-channel scalable systems |
| Respiration Chambers | Borosilicate static chambers (ID: 9–45 mm), Mini swim tunnels (170 mL, flow: 0.7–50 cm/s), 24-well high-throughput plates (well volumes: 80–1700 µL) |
| Software | AutoResp v5.x with SMR/Pcrit calculation, Excel/TXT export, GLP-compliant audit trail |
| Compliance | ASTM E1527-23 (respirometric bioassay), ISO 8692 (freshwater algal growth inhibition – adapted for fish respirometry), USP <1058> (analytical instrument qualification), FDA 21 CFR Part 11 (electronic records/signatures – optional configuration) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Magnet Type | Permanent Magnet |
| Field Strength | 1.0 T |
| Minimum Slice Thickness | 0.8 mm |
| Animal Weight Capacity | 1–45 g |
| Sample Diameter Limit | < 40 mm |
| Minimum Sample Volume | ≥ 100 µL |
| Scan Orientation | Arbitrary Angle & Arbitrary Plane |
| Compliance | Designed for Preclinical GLP-Compatible Workflow |
| Optional Modules | Gas Anesthesia System, ROI Analysis Software Suite |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42+ |
| Instrument Type | Preclinical MRI System for Rodent Research (Mouse/Rat) |
| Resonance Frequency | ~42 MHz |
| Static Magnetic Field Strength | 1.0 ± 0.05 T |
| Bore Diameter | 60 mm (Dedicated Animal RF Coil) |
| Magnet Type | Permanent Magnet |
| Application Scope | In vivo cell tracking, contrast agent evaluation, tumor modeling, metabolic phenotyping, longitudinal studies in mice and rats |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | QMR Series |
| Instrument Type | Research-Grade Small Animal (Mouse/Rat) Analyzer |
| Core Magnet | Permanent Magnet |
| Measurement Principle | Quantitative Low-Field NMR Relaxometry |
| Software | NIUMAG Proprietary Mouse Body Composition Analysis Suite |
| Compliance | Designed for GLP-aligned preclinical metabolic studies |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Magnet Type | Permanent Magnet |
| Application | In Vivo Rodent Metabolism Quantification (Mice, Rats, Rabbits) |
| Measurement Time | 1–3 min per scan |
| Sample State | Conscious, Non-Invasive, No Anesthesia or Sacrifice Required |
| Core Output Parameters | Fat Mass, Lean Body Mass, Total Body Water (TBW) |
| Compliance Context | Designed for GLP-aligned preclinical research workflows |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Research-Grade Small Animal (Mouse/Rat) Body Composition Analyzer |
| Sample Capacity | Live Mice and Rats |
| Primary Measurement | Fat Mass, Lean Body Mass, Free Water Content |
| Magnet Type | Permanent Magnet |
| Test Duration | ≤ 60 s per animal |
| Sample Preparation | None (Non-invasive, Non-anesthetized, Non-terminal) |
| Compliance Context | Designed for GLP-aligned preclinical metabolic phenotyping workflows |