Animal Metabolism Detection System
Filter
Showing 31–60 of 63 results
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Magnet Type | Permanent Magnet |
| Sample Type | Live Rodents (Mice, Rats, Rabbits) |
| Measurement Time | < 60 s per sample |
| Measured Parameters | Fat Mass, Lean Mass, Free Water Content |
| Software | Integrated QMR Analysis Suite with GLP-Compliant Audit Trail |
| Regulatory Compliance | Designed to support ISO/IEC 17025-aligned workflows and FDA 21 CFR Part 11–ready data integrity architecture |
| Application Scope | Preclinical metabolic phenotyping, longitudinal obesity/diabetes studies, pharmacological intervention monitoring |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | QMR06-060H-PRO |
| Instrument Type | Research-Grade Small Animal (Mouse/Rat) Analyzer |
| Sample Capacity | Single mouse (up to 50 g) or rat (up to 300 g) |
| Core Functions | In vivo quantification of fat mass, lean body mass, and total body water |
| Magnet System | Permanent magnet (low-field, ~0.06 T) |
| Measurement Time | ≤ 60 s per scan |
| Sample Preparation | Non-invasive, no anesthesia, no euthanasia required |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QMR06-090H |
| Instrument Type | In Vivo Small Animal (Rat/Mouse) Body Composition Analyzer |
| Sample Capacity | ≤800 g |
| Core Functions | Fat Mass, Lean Body Mass, Total Body Water Quantification |
| Construction | Benchtop Permanent-Magnet NMR System |
| Magnet Type | Permanent Magnet |
| Measurement Time | <60 s per scan |
| Sample Requirement | Conscious, Unanesthetized, Non-invasive |
| Regulatory Compliance | Designed for GLP-aligned preclinical research environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QMR06-090H |
| Instrument Type | Research-Grade Small Animal (Mouse/Rat) Body Composition Analyzer |
| Sample Capacity | 60 mm Bore — 10–100 g |
| Core Functions | In vivo quantification of total fat mass, lean tissue mass, and free water content |
| Magnet System | Permanent Magnet (Low-Field, ~0.3–0.5 T typical for QMR platforms) |
| Measurement Time | ≤ 60 s per subject |
| Sample Preparation | None — conscious or lightly restrained live animals only |
| Regulatory Context | Designed for GLP-compliant preclinical research environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Magnet Type | Permanent Magnet |
| Sample Types | Live rats, mice, rabbits |
| Measurement Time | ≤ 60 s per scan |
| Measured Parameters | Fat mass, lean tissue mass, free water content |
| Software | Integrated proprietary NMR quantification platform with GLP-compliant audit trail |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments |
| Hardware Architecture | Benchtop low-field NMR system (0.06–0.09 T) |
| Sample Handling | Non-invasive, non-destructive, no anesthesia or euthanasia required |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QMR06-090H |
| Instrument Type | Research-Grade Small Rodent Analyzer (Mouse/Rat) |
| Magnet Type | Permanent Magnet |
| Measurement Time | < 60 s per animal |
| Sample Requirement | Live, conscious, unrestrained |
| Measured Parameters | Fat Mass, Lean Body Mass, Free Water Content |
| Species Compatibility | Mus musculus, Rattus norvegicus, Oryctolagus cuniculus |
| Regulatory Context | Designed for GLP-compliant preclinical research environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | QMR06-090H-PRO |
| Instrument Type | Research-Grade Small Rodent Analyzer |
| Sample Capacity | 800 g |
| Magnet Type | Permanent Magnet |
| Measurement Principle | Low-Field Nuclear Magnetic Resonance (LF-NMR) |
| Species Compatibility | Live Rats, Mice, and Rabbits |
| Measurement Time | ≤ 60 s per sample |
| Measured Parameters | Fat Mass, Lean Body Mass, Free Water Content |
| Sample Preparation | Non-invasive, No Anesthesia or Euthanasia Required |
| Software | Integrated LF-NMR Acquisition & Quantification Suite with GLP-Compliant Audit Trail |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QMR1 |
| Instrument Type | Research-Grade Small Animal (Mouse) Body Composition Analyzer |
| Measurement Principle | Low-Field Nuclear Magnetic Resonance (LF-NMR) Relaxometry |
| Sample State | Conscious, Non-Invasive, Anesthesia-Free |
| Typical Scan Time | 60–180 s per mouse |
| Output Parameters | Fat Mass (g), Lean Mass (g), Total Water Mass (g), %Fat, %Lean, %Water |
| Magnet System | Permanent Magnet (0.3–0.5 T typical range) |
| RF Probe | Dedicated Quadrature Mouse-Sized RF Coil |
| Software | NIUMAG Small Animal Body Composition Analysis Suite (v4.x+) |
| Regulatory Compliance | Designed for GLP-aligned workflows |
| Brand | Panlab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Oxylet |
| Price Range | USD 25,000 – 65,000 |
| Brand | Parvo Medics |
|---|---|
| Origin | USA |
| Model | True One2400 |
| O₂ Analysis Range | 0–100% or 0–25% |
| O₂ Accuracy | ±0.02% |
| O₂ Response Time | 200 ms (21% → 16% in 4 L mixing chamber) |
| CO₂ Analysis Method | NDIR (Non-Dispersive Infrared) |
| CO₂ Range | 0–15% |
| CO₂ Accuracy | ±0.03% (for 0–10% CO₂) |
| CO₂ Response Time | 100 ms |
| Flow Measurement Accuracy | ±0.5% |
| Flow Range | 0–800 L/min |
| Calibration | Dual-stage (3 L syringe, 16% O₂ / 4% CO₂ gas mixture) |
| Operating Temperature | 14–30 °C |
| Relative Humidity | 20–80% RH |
| Warm-up Time | 30 min |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Software Platform | Windows XP–compatible proprietary metabolic analysis suite |
| Data Export | Native Excel (.xls) output |
| Brand | PyroScience |
|---|---|
| Origin | Germany |
| Model | RF-O2 Animal |
| Instrument Type | Research-Grade Animal Metabolism Analyzer (Rodent & Aquatic Models) |
| Measurement Principle | Phase-Fluorescence Lifetime Detection (REDFLASH Technology) |
| Oxygen Range Options | Full-Scale (0–100% O₂ / 0–44 mg/L DO) or Trace-Level (0–21% O₂ / 0–9 mg/L DO) |
| Channel Configurations | 1-, 2-, or 4-Channel Simultaneous Acquisition |
| Temperature Compensation | Real-Time Integrated Pt100 + Internal Thermistor |
| Environmental Sensors | Built-in Barometer (300–1100 mbar, ±3 mbar acc.) & Hygrometer (0–100% RH, ±0.2% RH acc.) |
| Interface | USB 2.0 (Bus-Powered, 5 VDC @ 20 mA) |
| Sampling Rate | Up to 20 Hz per channel |
| Dimensions | 78 × 120 × 24 mm |
| Weight | 290 g |
| Operating Temp | 0–50 °C, Non-Condensing |
| Software Suite | Pyro Workbench (Device Control, Calibration, Visualization) + Pyro Data Inspector (Respirometry Analysis, Drift Correction, MO₂ Calculation) |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FMS Portable |
| Pricing | Available Upon Request |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FMS- |
| Price Range | USD 7,200 – 14,300 |
| Dimensions | 35 × 30 × 15 cm |
| Weight | 4.0 kg |
| Power Supply | 12–15 VDC (AC adapter included) |
| Data Storage | Removable SD card (up to 32 GB) |
| Sampling Interval | 0.1 s – 1 h (user-configurable) |
| Gas Flow Control | 10–1500 mL/min (microelectronic thermal feedback loop, ±2% accuracy) |
| O₂ Sensor | Fuel cell, 0–100%, resolution 0.001%, drift <0.02%/h |
| CO₂ Sensor | NDIR dual-wavelength, 0–5%, resolution 0.0001–0.01%, drift <0.001%/h |
| H₂O Sensor | Platinum-electrode capacitive, 0–100% RH (non-condensing), resolution 0.001% RH, drift <0.01% RH/h |
| Temperature Compensation | Automatic (0–100 °C, ±0.2 °C accuracy) |
| Pressure Compensation | Automatic (30–110 kPa) |
| Analog Inputs | 8-channel bipolar voltage, 4-channel temperature |
| Digital I/O | 8 TTL control outputs, RS-232/USB + SableBus high-speed interface |
| Brand | Sable |
|---|---|
| Origin | USA |
| Model | FOXBOX |
| Gas Analyzers | Fuel Cell O₂ Sensor & NDIR CO₂ Sensor |
| O₂ Range | 0–100% |
| CO₂ Range | 0–5% |
| O₂ Accuracy | ±0.1% |
| CO₂ Accuracy | ±1% |
| O₂ Drift | <0.02%/hr (stable temp) |
| CO₂ Drift | <0.001%/hr (stable temp) |
| O₂ Resolution | 0.001% |
| CO₂ Resolution | 0.0001–0.01% (concentration-dependent) |
| Flow Control | Microprocessor-Regulated Thermal Feedback Loop |
| Flow Range (Internal Pump) | 10–1700 mL/min |
| Flow Accuracy | ±2% |
| Flow Resolution | 0.1 mL/min (0–99.9 mL/min), 1 mL/min (>100 mL/min) |
| Data Storage | 8,190 points |
| Logging Interval | 0.1 s to 1 hr (user-selectable) |
| Interface | RS-232, 2× BNC analog inputs, 3× BNC analog outputs |
| Display | 4-line LCD (real-time O₂, CO₂, flow) |
| Power | 12–15 VDC, 50–500 mA |
| Dimensions | 31 × 18 × 31 cm |
| Weight | 5 kg |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Scientific Instrument |
| Model | SSI Drosophila |
| Instrument Type | Research-Grade Small Animal (Drosophila & Micro-Invertebrate) Respirometry System |
| Key Measurement Parameters | Real-time CO₂ production (VCO₂), O₂ consumption (VO₂), respiratory quotient (RQ), water vapor pressure (H₂O), activity (via IR beam interruption), optional temperature & feeding behavior |
| Channel Configurations | 8-channel standard (7 sample + 1 baseline), expandable to 16-, 24-, or custom N-channel modular configurations |
| Analytical Principle | Open-flow indirect calorimetry with dual-wavelength NDIR CO₂ detection, paramagnetic or fuel-cell O₂ sensing, differential gas analysis architecture for single-fly resolution |
| Compliance Framework | Designed for GLP-compliant metabolic phenotyping |
| Software Platform | ExpeData™ (Windows-based, real-time acquisition, automated RQ/EE calculation, event-triggered sampling, batch analysis, export to CSV/MAT/Excel) |
| Optional Modules | AD-2 Infrared Activity Monitor, FLIC Feeding Behavior Module, MAVEn™ High-Density Integration Chassis, RH-300 Water Vapor Analyzer, SS4 Secondary Sampling Unit, MFC-2 Mass Flow Controller |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | SSI Modular |
| Instrument Type | Research-grade Rodent Metabolic Phenotyping System |
| Sample Capacity | Configurable Multi-channel (Standard 8-channel: 7 animal + 1 baseline) |
| Core Analytes | O₂, CO₂, H₂O vapor |
| Measurement Principle | Open-circuit respirometry with dual-wavelength NDIR CO₂ detection, paramagnetic O₂ sensing, and chilled-mirror dew-point H₂O analysis |
| Compliance Framework | Designed for GLP-compliant metabolic phenotyping |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SSI |
| Price Range | USD 7,200 – 14,300 |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SSI-System |
| Price Range | USD 7,200 – 14,300 (FOB USA) |
| Brand | Sable Systems International |
|---|---|
| Origin | USA |
| Model | IRIS-13C/18O |
| Measurement Principle | Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) |
| δ¹³C Range | −100‰ to +4000‰ |
| δ¹⁸O Range | −50‰ to +500‰ |
| CO₂ Range | 380–25,000 ppm |
| H₂O Range | 4,000–60,000 ppm |
| Precision (1σ, 1 Hz) | δ¹³C = 0.6‰, δ¹⁸O = 4.0‰, CO₂ = 0.05 ppm, H₂O = 50 ppm |
| Response Time | < 1.5 s (10–90%) |
| Sampling Frequency | 1 Hz |
| Operating Temperature | 5–45 °C |
| Power | 115/230 V AC, 50/60 Hz, 66 W |
| Dimensions (H×W×D) | 18 × 47 × 36 cm |
| Weight | 17 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Promethion Core |
| Price | Available Upon Request |
| Brand | Sable |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SSI-High-Throughput |
| Pricing | Upon Request |
| Brand | Sable |
|---|---|
| Origin | USA |
| Model | MAVEn™ High-Throughput 16-Channel |
| Flow Rate Range | 5–200 mL/min (mass flow controlled, ±2% accuracy) |
| Measurement Interval per Fly | 15 s (programmable from 15 s to 3 h) |
| O₂ Analyzer | Dual-channel fuel-cell sensor, 0–100% range, ±0.1% accuracy (2–100% O₂), 0.0001% resolution, <0.01%/h drift |
| CO₂ Analyzer | 0–3000 ppm, <1% accuracy, 0.01 ppm resolution |
| H₂O Analyzer | 0–60 mmol/mol, ±1% accuracy |
| Pressure Sensor | 1 Pa resolution, ±0.05% FS accuracy |
| Temperature Sensor | 0–50 °C, ±0.25 °C accuracy, 0.01 °C resolution |
| Illuminance Control | 0.1–5000 lux |
| Analog Inputs | 6 channels, 16-bit, −5 to +5 V |
| Data Output | CSV via SD card (up to 32 GB), RS-232, 0–5 V BNC analog outputs |
| Dimensions (O₂ Unit) | 43.2 × 35.6 × 20.3 cm |
| Weight (O₂ Unit) | 6.4 kg |
| Operating Temp | 5–45 °C, non-condensing |
| Brand | Tlyon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MMS |
| Instrument Type | Research-grade Small Animal (Mouse/Rat) Respirometry System |
| Sample Volume Capacity | 1 mL |
| Temperature Operating Range | 5–40 °C |
| Measured Parameters | O₂ concentration, CO₂ concentration, water vapor pressure, barometric pressure, relative humidity |
| Flow Rate Range | 1–1000 mL/min (adjustable) |
| Temperature Accuracy | ±0.1 °C |
| Relative Humidity Accuracy | ±1 %RH |
| Barometric Pressure Accuracy | ±0.075 % of full scale |
| Battery | Rechargeable 24 V / 10 Ah Li-ion, ≥8 h field operation |
| Data Storage | Onboard SD card + USB export |
| Compliance | Designed for GLP-compliant respirometry workflows |
| supports ASTM E2913-22 (Standard Guide for Respirometric Measurements in Small Animal Studies) and ISO 8573-1 (Compressed Air Purity — Part 1 | Contaminants and Classifications) for gas stream integrity |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | Metabolic PhenoCages |
| Application | Automated Metabolic Phenotyping in Mice and Rats |
| Urine/Feces Separation | Dual-compartment funnel with cryo-compatible collection vessels |
| Quantification Method | High-precision load cells (±0.01 g resolution) under chilled collection containers |
| Integration | Fully compatible with PhenoMaster® and LabMaster® modular monitoring platforms |
| Optional Modules | CaloCage™ for indirect calorimetry, food/water intake sensors, XYZ photobeam activity frame |
| Cage Design | Modular, autoclavable components with rapid disassembly for decontamination |
| Sample Preservation | On-board cryogenic separation — urine and feces collected into individually chilled, sealed compartments |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | PhenoMaster |
| Application | Modular, automated, long-term metabolic and behavioral phenotyping of rodents (mice and rats) |
| Cage Capacity | Up to 64 animals |
| Measurement Principle | Indirect calorimetry (O₂ consumption, CO₂ production, RER, energy expenditure) integrated with multi-sensor behavioral monitoring |
| Compliance | Designed for GLP-compliant studies |
| Software Platform | PhenoMaster Suite (v5.x or later), including experimental protocol scheduling, real-time visualization, raw data export (CSV, HDF5, MATLAB-compatible), and metadata-enriched database archiving |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | PhenoMaster_H |
| Configuration | Modular, Multi-Channel (up to 256 channels) |
| Gas Sensing | Zirconia O₂ sensor & NDIR CO₂ sensor |
| Flow Control | Independent high-flow controller per cage |
| Measurement Modes | Standard sequential mode & Real-time continuous mode (1 Hz per cage) |
| Data Output | Binary raw data with user-defined sampling frequency |
| Cage Airflow | Configurable PULL/PUSH mode with laminar wall-guided circulation |
| Activity Monitoring | XYZ optical 3D frame |
| Urine/Feces Collection | TSE-engineered hydrophobic umbrella-shaped internal lining |
| Compliance | Designed for GLP-compliant phenotyping studies |
| Software | PhenoMaster Control & Analysis Suite (FDA 21 CFR Part 11–ready audit trail, experimental protocol scheduling, time-synchronized multi-parameter export) |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | PhenoMaster_M |
| Application | Long-term, non-invasive metabolic phenotyping of small rodents (mice and rats) |
| Measurement Principle | Indirect calorimetry (O₂ consumption & CO₂ production via zirconia O₂ sensor and NDIR CO₂ sensor) combined with integrated behavioral and physiological monitoring |
| Channel Capacity | Up to 256 independently configurable cages |
| Gas Flow Control | Individual high-flow mass flow controllers per cage (PULL/PUSH selectable) |
| Data Acquisition | Raw binary time-series data (user-configurable sampling interval), full audit trail support |
| Compliance | Designed for GLP-compliant studies |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | PhenoMaster-R/M |
| Cage Capacity | Up to 64 rodents (rats or mice) |
| Measurement Principle | Indirect Calorimetry + Behavioral Sensor Fusion |
| Compliance | Designed for GLP-compliant metabolic phenotyping studies |
| Software Platform | PhenoMaster/LabMaster v5.x (FDA 21 CFR Part 11–ready audit trail, role-based access control, raw data export in CSV, HDF5, and MATLAB-compatible formats) |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | CaloSys |
| Measurement Principle | Open-circuit indirect calorimetry |
| Animal Capacity | Single- or multi-cage configurations (CaloCages) |
| Gas Sampling Interval | ~40 s per cage |
| Supported Modalities | Voluntary wheel running (sealed enclosure, programmable speed profiles) |
| Data Output | VO₂, VCO₂, RER, EE (kcal/h or kJ/h), locomotor activity |
| Software | CaloSys control and analysis suite with real-time visualization, timestamped interval-based file updates, tabular + graphical data export |
| Compliance | Designed for GLP-compliant metabolic phenotyping studies |
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Activity |
| Pricing | Available Upon Request |
