Atmospheric Particulate Matter Monitor
Filter
Showing 31–60 of 91 results
| Brand | METONE |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| Certification | U.S. EPA EQPM-0798-122 |
| Measurement Principle | Beta Ray Attenuation (¹⁴C source) |
| Particle Size Fractions | PM₂.₅, PM₁₀, TSP |
| Measurement Range | 0–50 mg/m³ |
| Sampling Interval | Hourly |
| Data Storage Capacity | 182 days |
| RH Control | Integrated Heater with Precise Relative Humidity Management |
| Calibration | Automated Zero/Drift Checks per Cycle |
| Output Interface | RS-232 |
| Meteorological Integration | Up to 6 Sensors |
| Remote Operation Duration | Up to 60 Days Unattended |
| Compliance | EPA EQPM, UK MCERTS, Korea KEPIC, China CNAS-accredited Ambient Monitoring Applications |
| Brand | Metone |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| EPA EQPM Certification | EQPM-0798-122 |
| Measurement Principle | Beta Ray Attenuation (¹⁴C source) |
| Particle Size Cutoffs | PM₁₀, PM₂.₅, TSP |
| Measurement Range | 0–50 mg/m³ |
| Sampling Frequency | Hourly |
| Filter Tape | Rotating glass fiber tape (30-sample capacity) |
| RH Control | Integrated heater for dew point suppression |
| Data Storage | 182 days (internal) |
| Communication | RS-232 serial interface |
| Meteorological Inputs | Up to 6 sensors |
| Remote Operation | Unattended operation up to 60 days via web-based telemetry |
| Calibration | Automated zero/drift checks per cycle |
| Compliance | U.S. EPA EQPM, UK MCERTS, Korea KEPIC, China CNAS-accredited field deployment records |
| Operating Environment | -30°C to +50°C ambient |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Brand | METONE |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| Measurement Method | Beta Ray Attenuation |
| Measured Parameters | PM10, PM2.5 |
| EPA Certification | EQPM-0798-122 (PM10 FEM), EQPM-0308-170 (PM2.5 Class III FEM) |
| Compliance | CE, NRC, TÜV, CARB, ISO 9001 |
| Range | 0–1000 µg/m³ (configurable up to 10,000 µg/m³) |
| Detection Limit | <1.0 µg/m³ (24-hr), <4.8 µg/m³ (1-hr) |
| Flow Rate | 16.7 L/min (adjustable 0–20 L/min) |
| Filter | Glass fiber tape, 30 mm × 21 m per roll |
| Beta Source | ¹⁴C, 60 µCi ±15 µCi (t₁/₂ = 5730 yr) |
| Data Storage | 182 days of hourly records |
| Operating Temp | –30 °C to +60 °C |
| RH Control | Internal heater, 10–99% RH setpoint |
| Power | 100–230 VAC, 50/60 Hz, <0.4 kW |
| Dimensions | 31 cm (H) × 43 cm (W) × 40 cm (D) |
| Weight | 24.5 kg |
| Brand | METONE |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| Certification | EPA EQPM-0798-122 |
| Measurement Principle | Beta Ray Attenuation (¹⁴C source) |
| Range | 0–50 mg/m³ |
| Sampling Method | Isokinetic Impactor with Rotating Glass Impactor Plate (30-sample capacity) |
| Data Output | Real-time mass concentration (µg/m³ or mg/m³), automatic zero/drift correction, event logging |
| Compliance | US EPA EQPM, UK MCERTS, Korea K-EMAS, China HJ 653-2013 |
| Brand | METONE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E-BAM |
| Pricing | Available Upon Request |
| Brand | Metone |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E-BAM |
| Pricing | Upon Request |
| Brand | Metone |
|---|---|
| Origin | USA |
| Model | E-BAM1020 |
| Measurement Principle | Beta-ray attenuation (β-ray) |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Measurement Range | 0–1.000 mg/m³ |
| Sampling Interval | 1 hour |
| Volumetric Flow Rate | 0–20 L/min |
| Detection Limit | <4.8 µg/m³ |
| Flow Stability | ±5% |
| EPA EQPM Certification | EQPM-0798-122 |
| Compliance | U.S. EPA Reference Method for PM₂.₅ (40 CFR Part 53, Subpart C) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | PM2.5 |
| Price Range | USD 14,000–21,000 |
| Measurement Method | Laser Light Scattering |
| Measured Parameters | PM10, PM2.5 |
| Dust Measurement Range | 0.01–100 mg/m³ |
| Dust Resolution | 0.01 mg/m³ |
| Dust Accuracy | ±10% (vs. calibration aerosol) |
| Dust Repeatability | ≤1% |
| Minimum Sampling Interval | ≤60 s |
| Sound Pressure Level Range | 35–130 dB(A) |
| Frequency Weighting | A-weighting |
| Time Weighting | Fast (F), Slow (S) |
| Microphone Sensitivity | ~15 mV/Pa |
| Frequency Response | 20 Hz–12.5 kHz |
| Operating Temperature | 0–40 °C |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PMT-2500 |
| Pricing | Available Upon Request |
| Detection Principle | Laser Light Scattering (90° scattering geometry) |
| Alarm Indicator | Tri-color LED (Green/Yellow/Red) with stepwise activation based on PM2.5 concentration thresholds |
| Power Supply | 3× AA alkaline batteries (internal) or DC 5 V via included USB cable |
| Display | 4-digit 7-segment LED |
| Accuracy | ±15 µg/m³ (for concentrations <100 µg/m³), ±15% (for ≥100 µg/m³) |
| Response Time | ≤6 seconds (T90) |
| Operating Temperature | −10 °C to +50 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Power Consumption | 0.6 W (active), 0.1 W (standby) |
| Data Logging | User-selectable intervals (1/5/10/30/60 min) |
| Dimensions | 81(W) × 40(H) × 141(D) mm |
| Weight | ≈345 g (including batteries and silicone rubber cover) |
| Accessories | USB cable (15 cm), AA batteries, protective silicone cover |
| Brand | SAIL HERO |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | BAM1020 |
| Measurement Method | Beta Ray Attenuation |
| Measured Parameters | PM10, PM2.5 |
| EPA Certification | EQPM-0798-122 (PM10), EQPM-0308-170 (PM2.5) |
| Calibration Standard | FRM-certified calibration membrane |
| Data Storage Capacity | 182 days |
| Remote Operation Duration | Up to 60 days |
| Humidity Control | Integrated precision heater for RH conditioning |
| Communication Interface | RS-232 serial port |
| Meteorological Sensor Support | Up to 6 channels |
| Automatic Span Check Frequency | Hourly |
| Filter Exchange Interval | Hourly |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | XHPM2000E |
| Measurement Principle | Beta-ray attenuation with dynamic heating system |
| Measured Parameter | PM₂.₅ mass concentration |
| Measurement Range | 0–0.1, 0.2, 1, 2, 5, or 10 mg/m³ (user-selectable full-scale ranges) |
| Measurement Cycle | 30 min to 60 min (configurable) |
| Sampling Flow Rate | 16.7 L/min ±2.5% |
| Limit of Detection (24-hr avg) | 5 µg/m³ |
| Compliance | Certified per Chinese EPA requirements for radioactive source management, HJ 653–2013, HJ 93–2013, and GB/T 34672–2017 |
| Regulatory Approvals | CEPAA Environmental Product Certification, CNEMC Calibration & Performance Verification Report, CIPAC Technical Appraisal Certificate for PM₂.₅ Separation Inlet |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XHPM2000E |
| Measurement Method | Beta-ray Absorption (β-ray) with Dynamic Heating System |
| Measured Parameter | PM₁₀ |
| Measurement Range | 0–0.1, 0.2, 1, 2, 5, or 10 mg/m³ (user-selectable full-scale) |
| Sampling Interval | 30 min to 1 h (configurable) |
| Sample Flow Rate | 16.7 L/min ±2.5% |
| Limit of Detection (24-h avg) | 1 µg/m³ |
| Compliance | EPA EQPM-0805-154 (equivalent), HJ 653–2013, HJ 93–2013, HJ 978–2018 |
| Brand | SAIL HERO |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XHPM2001 |
| Measurement Principle | Beta-ray Absorption (β-ray) |
| Measured Parameters | TSP, PM10, PM2.5, PM1 |
| Sampling Flow Rate | 16.7 L/min |
| Display | 7-inch High-Brightness TFT Touchscreen with Windows-based GUI |
| Calibration Method | Standardized Calibration Foil |
| Compliance | Certified by China Environmental Monitoring Station (CEMS) for PM10 Portability |
| Brand | SKC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DPS |
| Pricing | Upon Request |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | Sioutas Impactor |
| Flow Rate | 9 L/min |
| Cut Points | 2.5 µm, 1.0 µm, 0.5 µm, 0.25 µm |
| Collection Substrate | 25 mm PTFE filters (stages 1–4), optional 37 mm backup filter (<0.25 µm) |
| Pressure Drop | Low at 9 L/min for 24-h sampling |
| Compliance | Designed for OSHA, NIOSH, and ISO 7708-compliant personal aerosol monitoring |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | EAD-100 Series |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Measurement Principle | Optical Light Scattering |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | EPM-2050 |
| Price Range | USD 21,000 – 35,000 (FOB) |
| Measurement Method | Beta-ray Absorption (β-ray) |
| Measured Parameters | PM₂.₅, PM₁₀, TSP |
| Radioisotope Source | Carbon-14 (¹⁴C), Activity ≤ 100 µCi |
| Detection Limit | ≤ 2 µg/m³ (24-hr avg) |
| Concentration Range | 0–1000 µg/m³ or 0–10,000 µg/m³ |
| Resolution | 0.1 µg/m³ |
| Accuracy | ≤ ±5% (24-hr avg) |
| Flow Rate | 16.67 L/min (±2% stability) |
| Measurement Cycle | Adjustable, ≤ 60 min |
| Parallelism | ≤ ±10% |
| Display Interval | Default 1 hr, user-configurable |
| Operating Temp. (Analyzer) | 15–40 °C |
| Operating Humidity | ≤ 90% RH |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (L×W×H) | 417 × 483 × 382 mm |
| Weight | 25 kg (analyzer), 7.5 kg (pump) |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PM Series |
| Pricing | Upon Request |
| Measurement Principle | Extractive Nephelometry (Scattered Light Detection) |
| Measurable Parameters | Mass Concentration of Ambient and Flue Gas Particulate Matter (PM₁₀, PM₂.₅, TSP) |
| Detection Limit | 0.1 µg/m³ (as PM₁₀ equivalent) |
| Sampling Method | Heated Extractive Probe with Return-Line Conditioning |
| Optical Maintenance | Purge-Gas–Assisted Lens Cleaning |
| Calibration | In-Situ Auto-Zero and Span Calibration via Patented Reference Path Technology |
| Compliance | Designed to meet EN 15267-3, EN 14181 (QAL1/QAL2), and EPA Method 9/PS-11 requirements for continuous emission monitoring systems (CEMS) |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PM-200 |
| Pricing | Upon Request |
| Measurement Principle | Beta-Ray Absorption with Complementary Optical Scattering |
| Measured Parameter | Total Suspended Particulate Mass Concentration (PM) |
| Detection Limit | 0.1 mg/m³ (100 µg/m³) |
| Compliance | Designed to meet EU Directive 75/76/EEC requirements and EPA Method 5 for isokinetic sampling |
| Origin | Hubei, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | TH-β25 |
| Pricing | Upon Request |
| Measurement Principle | Beta-ray Absorption (Low-Energy β) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | pDR-1000AN |
| Measurement Principle | Optical Light Scattering (Forward Scatter at 50–90°) |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Detection Range | 0.001–400 mg/m³ |
| Particle Size Response | 0.1–10 µm |
| Output | Analog Voltage & Digital Serial (RS-232), Optional Alarm Relay |
| Weight | 0.5 kg |
| Dimensions | Palm-sized (approx. 12.7 × 8.9 × 4.4 cm) |
| Power | AC Adapter or Optional Rechargeable Battery |
| Calibration Traceability | NIST-traceable gravimetric calibration using SAE test dust |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 5020i |
| Measurement Principle | Pulsed Ultraviolet Fluorescence (PUVF) |
| Measured Parameter | Ambient Air Sulfate Aerosol Mass Concentration (as SO₄²⁻) |
| Range | 0–5, 10, 25, 50, or 100 μg/m³ (user-selectable) |
| Zero Noise | 0.20 μg/m³ (15-min average) |
| Limit of Detection (LOD) | 0.5 μg/m³ (15-min average) |
| Span Drift (24 h) | ±1% of full scale |
| Response Time (t₉₀) | 90 seconds |
| Sample Flow Rate | 0.4–0.5 L/min |
| Operating Temperature | 20–30 °C |
| Denuder Lifetime | 30 days (replaceable) |
| Converter Lifetime | >6 months (replaceable) |
| Dimensions (Analyzer/Converter) | 426 mm (W) × 219 mm (H) × 584 mm (D) |
| Weight (Analyzer) | ~20 kg (detector module) |
| (Converter) | ~17 kg (sample conditioning module) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model | 5030i (SHARP) |
| Measurement Method | Beta-ray attenuation with simultaneous optical scattering |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Measurement Ranges | 0–100, 0–1000, 0–2000, 0–3000, 0–5000, 0–10000 µg/m³ |
| Sampling Flow Rate | 16.67 L/min (1.0 m³/h) |
| Minimum Detection Limit | 1 µg/m³ (1-hour average) |
| Accuracy | ±2 µg/m³ for concentrations <80 µg/m³ |
| Flow Stability | ±5% (calibrated against NIST-traceable diaphragm standards) |
| Data Output Interval | 1 second |
| Beta Source | ¹⁴C, activity <3.7 MBq (<100 µCi) |
| Optical Source | IR LED, 6 mW, 880 nm |
| Heating System | Dynamic heated inlet (programmable temperature control) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TEOM 1405-DF |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM) |
| Measured Parameters | PM₁₀, PM₂.₅, and PMₜₕₒᵣₛₑ (coarse particulate matter) |
| Compliance | U.S. EPA Equivalent Method EQPM-0609-182 |
| Operating Temperature Range | −40 °C to +60 °C (sample gas) |
| Flow Rates | Fine channel: 3.0 L/min |
| Coarse channel | 1.67 L/min |
| Bypass | 12.0 L/min |
| Mass Resolution | 0.1 µg/m³ |
| Accuracy | ±2.0 µg/m³ (1-hr avg), ±1.0 µg/m³ (24-hr avg) |
| Data Output Interval | Configurable from 10 sec to 24 hr |
| Internal Memory | 500,000 records |
| Analog Outputs | 8 user-defined (0–1 V or 0–5 V DC) |
| Digital Interfaces | Ethernet, USB, RS-232, RS-485, FTP server |
| Power | Main unit: 100–240 VAC, 440 VA, 47–63 Hz |
| Vacuum pump | 120 VAC/60 Hz (4.25 A) or 240 VAC/50 Hz (2.25 A) |
| Dimensions (W×D×H) | 42.5 in × 47.5 in × 137.8 in |
| Weight | 38 kg |
| Safety Certifications | CE (EN 61326, EN 61010-1), UL 61010-1:2004, CSA C22.2 No. 61010-1:2004, FCC Part 15 Subpart B Class B |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific 5012 MAAP |
| Measurement Principle | Multi-angle integrated light absorption photometry |
| Measured Parameter | Black Carbon (BC) mass concentration and aerosol absorption coefficient (Babs) |
| Measurement Range | 0–900 ng/m³ (2-min avg), 0–180 ng/m³ (10-min avg), 0–60 ng/m³ (30-min avg) |
| Detection Limit | <100 ng/m³ BC / <0.66 Mm⁻¹ Babs (2-min), <50 ng/m³ BC / <0.33 Mm⁻¹ Babs (10-min), <20 ng/m³ BC / <0.13 Mm⁻¹ Babs (30-min) |
| Sample Flow Rate | 1 m³/h (16.7 L/min) |
| Environmental Correction | Real-time humidity and pressure compensation |
| Compliance | Designed to support EPA, EEA, and GAW reference-equivalent black carbon monitoring protocols |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Thermo Scientific 5014i |
| Measurement Principle | Beta Ray Attenuation |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Measurement Ranges | 0–100, 0–1,000, 0–2,000, 0–3,000, 0–5,000, 0–10,000 µg/m³ |
| Sampling Flow Rate | 1 m³/h (16.67 L/min) |
| Flow Stability | ±2% of setpoint |
| Minimum Detectable Concentration | 4 µg/m³ (1-hour average, 2σ), 1 µg/m³ (24-hour average, 2σ) |
| Accuracy (mass measurement) | ±5% against NIST-traceable filter standards |
| Precision | ±2 µg/m³ at concentrations <80 µg/m³ |
| Data Output Interval | 1 second |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | 5028i |
| Measurement Principle | Beta-ray Attenuation |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Measurement Range | 0–10 mg/m³ (0–10,000 µg/m³) |
| Sampling Flow Rate | 1 m³/h |
| Detection Limit | <1 µg/m³ (24-hour average) |
| Flow Stability | High stability |
| Regulatory Compliance | U.S. EPA EQPM for PM₁₀ (EQPM1102-150) and PM₂.₅ (EQPM0609-183) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | 5028i |
| Measurement Principle | Beta-ray Attenuation |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Measurement Range | 0–10 mg/m³ (0–10,000 µg/m³) |
| Sampling Flow Rate | 1 m³/h (16.67 L/min) |
| Detection Limit | <1 µg/m³ (24-hr, 2σ) |
| Data Output Interval | 1 s |
| Flow Stability | ±2% accuracy, <5% deviation |
| Regulatory Certification | US EPA EQPM for PM₁₀ (EQPM1102-150) and PM₂.₅ (EQPM0609-183) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | Thermo Scientific 5030 |
| Measurement Principle | Simultaneous Optical Scattering (880 nm IR LED) and Beta Attenuation (¹⁴C source, <100 µCi) |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Detection Limit | 0.5 µg/m³ (1-hour resolution) |
| Range | 0–1,000 µg/m³ and 0–10,000 µg/m³ (auto-ranging) |
| Flow Rate | 1 m³/h (16.7 L/min) |
| 24-hr Drift | ±0.002% full scale |
| Accuracy | ±2 µg/m³ for concentrations <80 µg/m³ |
| Light Source | Infrared LED (6 mW, 880 nm) |
| Beta Source | Carbon-14 (<100 µCi) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | 5030 (SHARP) |
| Measurement Method | Beta-ray Absorption + Light Scattering |
| Measured Parameters | PM₁₀ / PM₂.₅ |
| Concentration Range | 0–1,000 µg/m³ and 0–10,000 µg/m³ |
| LOD | <0.5 µg/m³ @ 2σ (1-hr resolution) |
| Accuracy | ±5% vs. 24-hr FRM |
| Time Resolution | 1 min (data updated every 4 s) |
| Drift | ≤0.02% per day |
| Flow Rate | 16.67 L/min |
| Radiation Source | ¹⁴C, 3.7 MBq (100 µCi), t₁/₂ = 5700 yr |
| Optical Source | IR LED, 880 nm, 6 mW |
| Operating Temperature | −30 to +60 °C |
| Power | Instrument: 100–240 VAC, 50/60 Hz, ≤330 W |
| Pump | 220–240 VAC, 50/60 Hz, 100 W |
| Dimensions (Instrument) | 483 × 311 × 330 mm (W×H×D) |
| Weight (Instrument) | 22.5 kg |
| Weight (Pump) | 8.1 kg |