Empowering Scientific Discovery

Beijing Ingerheid Analytical Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandC-Therm
ModelTrident
Measurement PrincipleIntegrated Modified Transient Plane Source (MTPS), Flexible Transient Plane Source (Flex TPS), and Transient Line Source (TLS Needle)
Thermal Conductivity Range0–2000 W/m·K
Accuracy<5%
Repeatability<1%
Operating Temperature Range–50°C to +500°C
Dimensions (L×W×H)40 × 40 × 40 cm
ComplianceASTM D7984, ISO 22007-2.2, ASTM D5334, ASTM D5930, IEEE 442, GB/T 32064
Added to wishlistRemoved from wishlist 0
Add to compare
BrandC-Therm
OriginCanada
ModelTrident TPS
Measurement PrincipleTransient Plane Source (TPS)
Dimensions (L×W×H)40 × 40 × 40 cm
Accuracy< 5%
Thermal Conductivity Range0 – 2000 W/m·K
Thermal Diffusivity Range0 – 1200 mm²/s
Specific Heat Capacity Range0 – 5 MJ/m³·K
Effusivity Range0 – 40,000 W·s⁰·⁵/m²·K
Repeatability< 1%
Test Duration0.8 – 180 s
ComplianceISO 22007-2:2015, GB/T 32064-2015
Added to wishlistRemoved from wishlist 0
Add to compare
OriginCanada
Manufacturer TypeDistributor
Origin CategoryImported
ModelTrident
Price RangeUSD 65,000–105,000
Instrument TypeTransient Plane Source (TPS) / Flexible TPS / Transient Line Source (TLS)
Dimensions (L×W×H)300 × 300 × 212 mm
Accuracy±1%
Thermal Conductivity Range0–500 W/(m·K)
RepeatabilityHigh
Added to wishlistRemoved from wishlist 0
Add to compare
BrandC-Therm
OriginCanada
ModelTrident MTPS
Measurement PrincipleModified Transient Plane Source (MTPS)
Dimensions (L×W×H)40 × 40 × 40 cm
Accuracy< 5%
Thermal Conductivity Range0 – 2000 W/m·K
Repeatability< 1%
Thermal Diffusivity Range0 – 1200 mm²/s
Specific Heat Capacity Range0 – 5 MJ/m³·K
Effusivity Range0 – 40,000 W·s⁰·⁵/m²·K
Test Duration0.8 – 180 s
ComplianceISO 22007-2, ASTM D7984, ASTM D5334, ASTM D5930, GB/T 32064
Added to wishlistRemoved from wishlist 0
Add to compare
BrandC-Therm
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelTrident Film
Instrument TypeTransient Plane Source (TPS) Method
Dimensions (L×W×H)40 × 40 × 40 cm
AccuracyBetter than 5%
Thermal Conductivity Range0 – 2000 W/m·K
RepeatabilityBetter than 1%
ComplianceISO 22007-2, ASTM D7984, GB/T 32064
Added to wishlistRemoved from wishlist 0
Add to compare
BrandC-Therm
OriginCanada
ModelFlex TPS
Measurement PrincipleTransient Plane Source (TPS)
Dimensions (L×W×H)40 × 40 × 40 cm
Accuracy< 5%
Thermal Conductivity Range0 – 2000 W/m·K
Repeatability< 1%
Standards ComplianceASTM D7984, ISO 22007-2.2, GB/T 32064, ASTM D5334, ASTM D5930, IEEE 442
Added to wishlistRemoved from wishlist 0
Add to compare
BrandC-Therm
ModelTCi
Measurement PrincipleTransient Plane Source (TPS) – Multi-Method Platform (MTPS, Flex TPS, Needle TLS)
OriginCanada
Dimensions (L×W×H)40 × 40 × 40 cm
Accuracy< 5%
Repeatability< 1%
Thermal Conductivity Range0–2000 W/m·K
Thermal Diffusivity Range0–1200 mm²/s
Specific Heat Capacity Rangeup to 5 MJ/m³·K
Effusivity Range5–40,000 W·s⁰·⁵/m²·K
Standards ComplianceASTM D7984, ASTM D5334, ASTM D5930, ISO 22007-2.2, GB/T 32064, IEEE 442
Added to wishlistRemoved from wishlist 0
Add to compare
BrandC-Therm
OriginCanada
ModelTrident HotDisk
Measurement PrincipleTransient Plane Source (TPS)
Dimensions (L×W×H)40 × 40 × 40 cm
AccuracyBetter than 5%
Thermal Conductivity Range0 – 2000 W/m·K
RepeatabilityBetter than 1%
Standards ComplianceISO 22007-2, ASTM D7984, ASTM D5334, ASTM D5930, GB/T 32064